| Plan Review Stops For Permit 03010432 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
17 |
Status |
P |
Date |
2003-11-05 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-11-05 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-11-05 |
Time |
17:58 |
Sent To |
|
|
| Notes |
| 2003-11-05 00:00:00 | REVISION 10/23/03 FOR LOADING RAMP | | | DETAIL SHEET A-16 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
16 |
Status |
P |
Date |
2003-11-05 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-11-05 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-11-05 |
Time |
17:27 |
Sent To |
|
|
| Notes |
| 2003-11-05 00:00:00 | REVISION 10/23/03 FOR 40' LONG RETAINING | | | WALL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
15 |
Status |
P |
Date |
2003-08-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-24 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-08-25 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2003-08-25 00:00:00 | REVISION SUBMITTED 8/18/03 FOR TRUCK | | | RAMPS AND OVERHEAD DOORS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
F |
Date |
2003-08-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-18 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-08-06 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2003-08-06 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | REVISION SUBMITTED ON 7/31/03 FOR TRUCK | | | RAMPS AND OVERHEAD DOORS: | | | | | | 1) FBC 1707.4OVERHEAD DOORS ON NORTH | | | AND WEST ELEVATIONS.THE PROPOSED | | | REVISIONS WOULD INCREASE THE OPENING | | | WIDTH TO 12'.THAT SIZE IS OUTSIDE THE | | | SCOPE OF THE SUBMITTED J.B. GARAGE DOOR, | | | INC. STEEL OVERHEAD GARAGE DOOR PRODUCT | | | APPROVAL NOA# 01-0129.16.SUBMIT THREE | | | COPIES OF ALTERNATIVE PRODUCT APPROVAL | | | OR AMEND THE OPENING SIZE ON THE PLANS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
F |
Date |
2003-08-06 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-08-06 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-08-06 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2003-08-06 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | SUBMITTAL ON 7/31/03 FOR ADDITIONAL | | | STEEL SHOP DRAWINGS: | | | | | | 1) STRUCTURAL SHOP DRAWINGS SHALL BE | | | REVIEWED AND STAMPED BY THE ENGINEER OF | | | RECORD BEFORE SUBMITTAL.ALTERNATIVELY, | | | A SIGNED AND SEALED LETTER FROM THE | | | ENGINEER OF RECORD CAN BE SUBMITTED WITH | | | THE DRAWINGS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
P |
Date |
2003-08-06 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-08-06 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-08-06 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2003-08-06 00:00:00 | REVISION SUBMITTED 7/23/03 FOR COLUMN | | | FIRE PROTECTION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2003-08-06 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-08-06 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-08-06 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2003-08-06 00:00:00 | REVISION SUBMITTED 7/23/03 FOR FLASHING | | | DETAIL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2003-08-06 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-08-06 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-08-06 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2003-08-06 00:00:00 | REVISION SUBMITTED 7/23/03 FOR JOIST AND | | | GIRDER DETAILS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-31 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-05-19 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2003-05-19 00:00:00 | 5-12-03 SUBMITTAL FOR WALL LIFT | | | ENGINEERING |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-05-19 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-05-19 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2003-05-19 00:00:00 | 5-12-03 SUBMITTAL FOR ROOFING PRODUCT | | | APPROVAL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2003-04-23 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-12 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-04-23 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2003-04-23 00:00:00 | 4-18-03 SUBMITTAL FOR STOREFRONT FRAMING | | | SYSTEM AND ANCHORAGE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2003-04-22 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-04-22 |
Time |
19:20 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-04-22 |
Time |
19:20 |
Sent To |
|
|
| Notes |
| 2003-04-22 00:00:00 | 4-18-03 SUBMITTAL FOR WALL PANEL REINF. | | | SHOP DRAWINGS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2003-04-22 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-04-22 |
Time |
19:13 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-04-22 |
Time |
19:13 |
Sent To |
|
|
| Notes |
| 2003-04-22 00:00:00 | 4-18-03 SUBMITTAL FOR WALL PANEL SHOP | | | DRAWINGS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-04-22 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-04-22 |
Time |
18:43 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-04-22 |
Time |
18:42 |
Sent To |
|
|
| Notes |
| 2003-04-22 00:00:00 | STRUCTURAL STEEL SHOP DRAWING SUBMITTAL | | | ON 4-18-03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-04-11 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-18 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-04-10 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2003-04-10 00:00:00 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | --PROVISO-- | | | THE SUBMITTED RATIONAL ANALYSIS FOR THE | | | STOREFRONT DOORS REFERS TO MIAMI-DADE | | | PRODUCT APPROVAL NOA# 01-0226.05.THAT | | | PRODUCT APPROVAL (NOT SUBMITTED WITH THE | | | APPLICATION) HAS BEEN DOWNLOADED FROM | | | THE MIAMI-DADE WEBSITE AND ATTACHED TO | | | THE RATIONAL ANALYSIS SHEETS.ANY | | | DEVIATION FROM THE PRODUCT APPROVAL AND | | | RATIONAL ANALYSIS WILL REQUIRE A | | | SEPARATE PERMIT APPLICATION AND FEES. | | | NOTE:UNLIKE THE ONE PREVIOUSLY | | | SUBMITTED, DOOR PRODUCT APPROVAL | | | NOA# 01-0226.05 AND ASSOCIATED RATIONAL | | | ANALYSIS WILL REQUIRE HURRICANE SHUTTERS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-03-24 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-04 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-03-24 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2003-03-24 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 2/11/03: | | | | | | 2) SUBMITTAL OF THE RECEIPT FOR IMPACT | | | FEES IS NOTED BUT THE SUBMITTED PLANS | | | ARE NOT STAMPED BY PAIM BEACH COUNTY | | | BUILDING DEPT TO VERIFY THAT THEY ARE | | | THE PLANS ASSESSED FOR IMPACT.INSERT | | | ONE STAMPED PLAN SHEET INTO EACH SET. | | | | | | 7) FBC* 104.2.1CANTILEVERED CONCRETE | | | EYEBROW DETAIL 5/S4.4.THE SUBMITTED | | | HAND-DRAWN SKETCH DOES NOT SHOW THE | | | DOWEL BAR BEING USED IN ACCORDANCE WITH | | | THE MANUFACTURER'S RECOMMENDATIONS. | | | REVIEW AND AMEND THE DETAIL AS NECESSARY | | | THE DETAILS SHALL BEAR THE NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR | | | SPECIFYING THE DOWEL CONNECTORS.THE | | | DETAILS SHALL THEN BE SIGNED AND DATED | | | BY THE ENGINEER OF RECORD TO CONFIRM | | | THAT THEY HAVE BEEN REVIEWED AND | | | ACCEPTED. | | | | | | 13)FBC 13-101.1.6SHELL BUILDINGS. | | | THE PROJECT INFORMATION HAS NOT BEEN | | | ENTERED ON PAGE 1 OF THE SUBMITTED CODE | | | COMPLIANCE FORM 400B.ALSO, FOR SHELL | | | BUILDINGS, ALL ASSUMPTIONS MADE ABOUT | | | FEATURES NOT INSTALLED UNTIL LATER, AND | | | ARE NOT ON THE BUILDING PLANS, SHALL BE | | | LISTED AND APPENDED TO FORM 400B.THIS | | | WILL BE COMPARED TO THOSE FEATURES | | | PROPOSED FOR INSTALLATION AT A LATER | | | DATE WHEN COMPLETION OF THE BUILDING IS | | | PERMITTED. | | | | | | 15) DOOR AND WINDOW SCHEDULES, SHEETS | | | A-5 AND A-7 SHOW A 9'-0" HIGH STOREFRONT | | | DOOR WHICH EXCEEDS THE MAXIMUM HEIGHT | | | COVERED BY SUBMITTED PRODUCT APPROVAL | | | NOA# 01-0919.02 | | | | | | 16) FBC* 105.3RESIDENT INSPECTOR | | | PROGRAM.SUBMIT A THIRD SET OF THE | | | PLANS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-02-11 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-02-11 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-02-11 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2003-02-11 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT SHALL BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | A COPY OF THE RECEIPT SUBMITTED, TO CITY | | | OF WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) FBC 705.1.1.2NORTH END OF THE WEST | | | ELEVATION.THAT SECTION OF THE WALL | | | WHICH IS WITHIN 15 FEET OF THE PROPERTY | | | LINE SHALL HAVE ALL OPENINGS EQUIPPED | | | WITH APPROVED OPENING PROTECTIVES (SEE | | | FBC 705.1.3) WITH A RATING OF NOT LESS | | | THAN 3/4 HOUR. | | | | | | 4) FBC* 1804.2.2SUBMIT A GEOTECHNICAL | | | REPORT (REF: DRAWING SHEET S5.2, | | | SITE WORK NOTE #2). | | | | | | 5) FBC* 104.2.1.2FOUNDATION SECTION | | | 7/S4.1 (TYP).NO ANCHORAGE | | | REINFORCEMENT IS SHOWN BETWEEN THE TILT- | | | UP WALL PANELS AND THE FOUNDATIONS. | | | SUBMIT AN ENGINEER'S SIGNED AND SEALED | | | LETTER, CONFIRMING THAT NO ANCHORAGE TO | | | THE FOUNDATION IS REQUIRED FOR UPLIFT OR | | | FOR LATERAL LOAD DUE TO THE RETAINED | | | FILL AND THE WAREHOUSE FLOOR SURCHARGE | | | LOADS. | | | | | | 6) NOTE:DETAIL 8/S4.1 HAS BEEN RED- | | | LINED TO REFERENCE 9/S4.1 WHICH DOES NOT | | | APPEAR TO BE CALLED UP ANYWHERE ON THE | | | PLANS. | | | | | | 7) PROVISO: FBC* 104.2.1.2 DETAIL 5/S4.4 | | | INCIDENTAL/MAINTENANCE LOADING ON THE | | | CANTILEVER CONCRETE 'EYEBROW'.SUBMIT | | | SHOP DRAWINGS OF THE MEANS OF ATTACHING | | | THE 'EYEBROW' TO THE TILT-UP WALL PANEL. | | | | | | 8) FBC* F102.2.4FIRE DISTRICT.AMEND | | | THE PLANS TO INCLUDE THE REQUIREMENT FOR | | | THE ROOF COVERING TO BE CLASS A OR B, AS | | | THE BUILDING IS WITHIN THE FIRE DISTRICT | | | | | | 9) SUBMIT A PRODUCT APPROVAL FOR THE | | | PROPOSED ROOFING SYSTEM. | | | | | | 10) SUBMIT A PRODUCT APPROVAL FOR THE | | | PROPOSED HURRICANE MISSILE IMPACT | | | PROTECTION SHUTTERS. | | | | | | 11) METAL AWNINGS.SUBMIT DETAILS, OR | | | A SEPARATE AWNING PERMIT APPLICATION | | | WILL BE REQUIRED. | | | | | | 12) A SEPARATE PERMIT APPLICATION WILL | | | BE REQUIRED FOR THE DUMPSTER ENCLOSURE. | | | | | | 13) NOTE:FBC 13-101.1.6ENERGY CODE | | | COMPLIANCE SHALL BE DEMONSTRATED BY | | | SUBMITTAL OF CODE COMPLIANCE FORM 400B | | | WITH A LIST APPENDED TO DESCRIBE THE | | | ASSUMPTIONS MADE ABOUT BUILDING FEATURES | | | NOT INSTALLED DURING THIS PHASE OF THE | | | PROJECT. | | | | | | 14) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-12-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-12-18 |
Time |
15:22 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-12-18 |
Time |
15:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-03-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-17 |
Time |
06:47 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-03-17 |
Time |
06:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-02-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-07 |
Time |
11:31 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-02-07 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2003-02-07 00:00:00 | ***************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE RISER DIAGRAM, | | | PLEASE SHOW SIZE OF METER AND MAIL DISC | | | FEEDING NEW PANEL 1HP. PLEASE ALSO | | | SEE LOAD SHOWN AT 147A'S WITH #3'S | | | FEEDING A 225A PANEL? PLEASE SIZE | | | CONDUCTORS ACCORDING TO 310-16 AND OCP | | | PER 240. | | | | | | 2)NOTE: PLEASE SHOW AIC RATING OF THAT | | | SAME NEW (HOUSE) DISCONNECT. | | | IF DIFFERENT FROM TYPICALS?? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2003-02-10 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-02-10 |
Time |
09:54 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2003-02-10 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2003-02-10 00:00:00 | PASSED: | | | 1. SEE PERMIT # 03012266 FOR UNDERGROUND | | | UTILITIES AND SITE WORKS. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-03-19 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-03-19 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-03-19 |
Time |
12:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-02-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-02-07 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-02-07 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2003-02-07 00:00:00 | 1) SITE PLAN SHALL SHOW ALL FIRE | | | HYDRANTS LOCATED IN THE VICINTY OF THE | | | BUILDING. | | | | | | 2) NO FIRE SPRINKLER PLANS OR HYDRAULIC | | | CALCULATIONS PROVIDED WITH DRAWINGS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2003-10-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-24 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-24 |
Time |
10:36 |
Sent To |
B |
|
| Notes |
| 2003-10-24 00:00:00 | TO RB DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2003-10-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-24 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-24 |
Time |
10:32 |
Sent To |
B |
|
| Notes |
| 2003-10-24 00:00:00 | TO RB DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2003-08-18 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-18 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-18 |
Time |
14:49 |
Sent To |
B |
|
| Notes |
| 2003-08-18 00:00:00 | TO RB DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2003-07-31 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-31 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-31 |
Time |
14:20 |
Sent To |
B |
|
| Notes |
| 2003-07-31 00:00:00 | TO RB DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-07-31 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-31 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-31 |
Time |
08:52 |
Sent To |
B |
|
| Notes |
| 2003-07-31 00:00:00 | TO RB DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-07-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-23 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-23 |
Time |
11:11 |
Sent To |
B |
|
| Notes |
| 2003-07-23 00:00:00 | TO RB DESK,3 REVISIONS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-05-12 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-12 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-12 |
Time |
13:18 |
Sent To |
B |
|
| Notes |
| 2003-05-12 00:00:00 | RBROWN DESK\\ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-04-18 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-18 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-18 |
Time |
15:56 |
Sent To |
B |
|
| Notes |
| 2003-04-18 00:00:00 | RBROWN DESK.4 RESUBS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-04-04 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-04 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-04 |
Time |
14:59 |
Sent To |
B |
|
| Notes |
| 2003-04-04 00:00:00 | RBROWN DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-02-27 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-01-31 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-27 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2003-02-27 00:00:00 | TO COMM BOARD #62 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-01-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-09 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-01-09 |
Time |
18:56 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-03-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-03-10 |
Time |
09:20 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-03-10 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2003-03-10 00:00:00 | MECHANICAL PERMIT 03022068 | | | SCOPE OF THIS PERMIT IS ELECTRICAL ROOM | | | EXHAUST ONLY.TENANT BUILDOUT WILL | | | BE UNDER SEPARATE PERMIT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-02-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-10 |
Time |
09:58 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2003-02-10 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2003-02-10 00:00:00 | DENIED: | | | REFERENCE PLAN SHEET A-9 & 10 NOTES: | | | PLEASE CLARIFY HOW THE VENTILATION | | | REQUIREMENTS ARE TO BE MET (.05 CFM PER | | | SQ FT) WITHOUT INSTALLING THE CURBS & | | | EXHAUST FANS. | | | | | | PROVISO: | | | EXHAUST FANS FOR THE ELEC/PUMP ROOMS - | | | EXHAUST SHALL NOT BE DIRECTED ONTO | | | WALKWAYS AS PER 2001 FBC(M) 401.5.2. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-03-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-26 |
Time |
07:45 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-03-26 |
Time |
07:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-01-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-30 |
Time |
17:11 |
Rev Time |
1.33 |
| Received By |
kstevens |
Date |
2003-01-30 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2003-01-30 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHTS A-6, A-9, & A-15 DETAIL #3. | | | A-6 SHOWS SCUPPER SIZE TO BE 12"X20", | | | A-9 SHOWS SCUPPER SIZE TO BE 10"X23", | | | A-15 SHOWS SCUPPER SIZE TO BE 12"X20", | | | PLEASE CLAIRFY. | | | 2) PLEASE PROVIDE CALCULATIONS FOR ROOF | | | DRAINS, PRIMARY AND SECONDARY PER SEC | | | 1106, AND 1107. SHOW TOTAL SQ FT INCLUD- | | | ING 1/2 AREA OF ALL VERTICAL WALLS & | | | PARAPET WALLS. | | | 3) SHT PO.1 WATER RISER, AIR CHAMBERS | | | ARE NOT APPROVED AND WATER HAMMER ARRES- | | | TORS REQUIRED BY 604.9 SHALL BE LOCATED | | | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" | | | NOT ABOVE THE CEILING AT THE TOP OF THE | | | DROPS. | | | 4) SHT PO-1 PLUMBING NOTES #13 AIR CHAM- | | | BERS ARE NOT APPROVED. PLEASE DELETE | | | FROM REFERENCE. | | | 5) SHT P2.1 FLOOR DRAIN FROM PUMP ROOM | | | SHALL DRAIN TO SANITARY NOT STORM. | | | 6) SEPARATE IRRIGATION PLANS AND PERMIT | | | REQUIRED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-01-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-09 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|