Plan Review Details - Permit 03010411
Plan Review Stops For Permit 03010411
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-05-08 Cont ID  
Sent By rmcdouga Date 2003-05-08 Time 15:20 Rev Time 3.00
Received By rmcdouga Date 2003-05-08 Time 15:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-04-30 Cont ID  
Sent By pkrauss Date 2003-05-07 Time 14:40 Rev Time 4.00
Received By rmcdouga Date 2003-04-29 Time 13:55 Sent To  
Notes
2003-04-29 00:00:00BUILDING DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) PROVIDE A UNITY OF TITLE AND
 DOCUMENTATION FROM PALM BEACH COUNTY
 THAT THE LOTS HAVE BEEN COMBINED INTO
 ONE LOT WITH ONE PROPERTY CONTROL
 NUMBER.
  
 4) SEPARATE PERMITS AND FEES WILL BE
 REQUIRED FOR THE DRIVEWAY, ROOFING,
 PLUMBING, MECHANICAL AND ELECTRICAL
 PERMITS AS THEY WERE NOT SIGNED ON THE
 PERMIT APPLICATION.
  
 5) SAFETY GLAZING IS REQUIRED IN THE
 BATHROOMS WITHIN 3 FEET HORIZONTALLY OF
 THE TUB/SHOWER PER FBC 2405.2.
  
 6) THE OWNER/AGENT IS REQUIRED TO SIGN
 AND DATE THE ENERGY CALCULATION FORMS.
  
 7) THE ANCHORAGE CALCULATIONS ON S2
 SPECIFY A SIMPSON ETA-12. THIS IS NOT
 LISTED IN THE 2003 CATALOG. SHOULD IT BE
 A META-12?
  
 8) A 1-1/2" RECESS IS REQUIRED AT THE
 EXTERIOR MASONRY WALLS PER CITY OF WPB
 AMENDMENTS 2111.1.9. PLEASE INDICATE ON
 PLANS.
  
 9) MONOLITHIC SLAB IS REQUIRED TO BE A
 MINIMUM OF 4 INCHES ABOVE FINISH GRADE
 AT HABITABLE AREAS PER CITY AMENDMENTS
 1804.1.7. PLEASE INDICATE ON PLANS.
  
 10) FBC 1804.1.4 REQUIRES THE BOTTOM OF
 THE FOOTINGS TO BE A MINIMUM OF 12
 INCHES BELOW GRADE. INDICATE ON PLANS.
  
 11) PROVIDE BUCK DETAILS FOR SIDE SWING
 DOORS AND OVERHEAD GARAGE DOOR.
  
 12) PLEASE SPECIFY THE CONNECTORS THAT
 WILL BE USED TO ANCHOR THE GIRDER
 TRUSSES AT THE MAIN HOUSE AND GARAGE/APT
  
 13) THE FOUNDATION PLAN FOR THE GARAGE/
 APARTMENT DOES NOT INDICATE AN ELEVATION
 CHANGE (STEP DOWN) BETWEEN THE APARTMENT
 AND THE GARAGE. IS THIS CORRECT?
  
 14) INDICATE THE 1-1/2" RECESS AT THE
 EXTERIOR MASONRY WALL, THE MINIMUM 4"
 ABOVE GRADE OF FINISH FLOOR SLAB AT
 HABITABLE AREAS AND THE MINIMUM 12"
 BELOW GRADE TO BOTTOM OF FOOTER ON THE
 PLAN FOR THE GARAGE/APT.
  
 15) INDICATE THE LOCATION OF THE WATER
 HEATER AT THE GARAGE/APT. SPECIFY HOW IT
 WILL BE PROTECTED FROM DAMAGE IF LOCATED
 IN THE GARAGE.
  
 16) THE ROOF PITCH GIVEN ON THE ROOF
 FRAMING PLAN ON AP1 DIFFERS WITH THE
 PITCH LISTED ON THE ELEVATIONS ON AP2.
  
 17) THE AREA CALCULATIONS FOR THE GARAGE
 APARTMENT ON AP1 ARE INCORRECT. THE
 APARTMENT IS 513 SQFT AND THE GARAGE IS
 235 SQFT AND THE TOTAL IS 748 SQFT.
  
 18) THE ONE BATHROOM IN THE GARAGE/APT
 IS LABELED AS BATH 2.
  
 19) SUBMIT A KEY PLAN AND INSTALLATION
 SCHEDULE FOR THE STORM PANELS FOR BOTH
 STRUCTURES.
  
 20) THE PRODUCT APPROVALS THAT WERE
 SUBMITTED DO NOT CORRESPOND TO THE
 EXTERIOR DOORS AND WINDOWS SPECIFIED IN
 THE SCHEDULES IN THE PLANS.
  
 21) THE PLANS SPECIFY HORIZONTAL SLIDING
 WINDOWS AND THE PRODUCT APPROVALS THAT
 WERE SUBMITTED ARE FOR SINGLE HUNG.
  
 22) THE DRAWINGS (# S-2166) SUBMITTED
 WITH THE SINGLE OUTSWING DOOR
 (NOA #02-0712.06) ARE NOT THE CORRECT
 DRAWINGS FOR THIS PRODUCT.
  
 23) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - DOUBLE INSWING DOORS
 - SLIDING GLASS DOORS
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-04-10 Cont ID  
Sent By sgraham Date 2003-03-27 Time 15:47 Rev Time 0.75
Received By btrobaug Date 2003-04-09 Time 16:47 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-05 Cont ID  
Sent By shernand Date 2003-05-05 Time 15:52 Rev Time 0.00
Received By shernand Date 2003-05-05 Time 15:52 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-26 Cont ID  
Sent By sthyng Date 2003-03-26 Time 15:23 Rev Time 0.00
Received By sthyng Date 2003-03-26 Time 15:23 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-05-07 Cont ID  
Sent By pkrauss Date 2003-05-07 Time 14:40 Rev Time 0.40
Received By pkrauss Date 2003-05-07 Time 14:40 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-04-19 Cont ID  
Sent By shernand Date 2003-05-05 Time 15:52 Rev Time 0.50
Received By rregueir Date 2003-04-19 Time 11:41 Sent To  
Notes
2003-04-19 00:00:00DENIED
 GARAGE APARTMENT:
 1) SEER ON ENERGY CALCS DOES NOT MATCH
 EQUIPMENT LISTED ON PLANS
 2) EXHAUST FAN REQUIRED IN BATHROOM PER
 FBC,M TABLE M403
 REVIEWED BY: RONALD J REGUEIRO
 561-805-6734

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-04-14 Cont ID  
Sent By btrobaug Date 2003-04-10 Time 16:43 Rev Time 0.33
Received By jleech Date 2003-04-14 Time 20:20 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2003-03-27 Cont ID  
Sent By sgraham Date 2003-03-27 Time 15:47 Rev Time 0.00
Received By sgraham Date   Time   Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2003-02-05 Cont ID  
Sent By sthyng Date 2003-03-26 Time 15:23 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
2003-01-15 00:00:00DENIED, PLAN NOT MEETING THE LANDSCAPE
 CODE 1000 SQ FT OR 75% OF FRONT MUST BE
 LANDSCAPED
 2. NO SHELLROCK D/W ALLOWED
 3. NO APPROACHES MUST BE 3' FROM
 PROPERTY LINE