Plan Review Details - Permit 03010230
Plan Review Stops For Permit 03010230
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-01-16 Cont ID  
Sent By kstevens Date 2003-01-16 Time 07:41 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-01-09 Cont ID  
Sent By btrobaug Date 2003-01-09 Time 17:43 Rev Time 0.50
Received By btrobaug Date   Time   Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-01-07 Cont ID  
Sent By sgraham Date 2003-01-08 Time 13:16 Rev Time 0.00
Received By btrobaug Date 2003-01-07 Time 12:28 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-01-21 Cont ID  
Sent By kstevens Date 2003-01-21 Time 18:21 Rev Time 0.25
Received By kstevens Date 2003-01-21 Time 18:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-01-16 Cont ID  
Sent By btrobaug Date 2003-01-09 Time 17:43 Rev Time 1.00
Received By kstevens Date 2003-01-15 Time 18:48 Sent To B
Notes
2003-01-16 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001 424.2.7.2 PUMPS AND EQUIP-
 MENT SHALL BE MOUNTED ON A SUBSTANTIAL
 BASE IN A MANNER THAT WILL ELIMINATE
 STRAIN ON PIPING. SLAB SHALL BE A NOMIN-
 AL 4" THICK. (DETAIL)
 2) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 3) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 4) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 4) FBC-2001 424.2.14.4 CONNECTIONS, ALL
 WATER HEATING EQUIPMENT SHALL BE INSTAL-
 LED WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER. (ADD TO NOTES)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2003-01-08 Cont ID  
Sent By btrobaug Date 2003-01-07 Time 12:28 Rev Time 0.00
Received By sgraham Date   Time   Sent To I
Notes
***NONE***