Plan Review Details - Permit 03010203
Plan Review Stops For Permit 03010203
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-03-07 Cont ID  
Sent By jgomez Date 2003-03-07 Time 14:05 Rev Time 0.33
Received By jgomez Date 2003-03-07 Time 14:05 Sent To  
Notes
2003-03-07 00:00:00GARAGE DOORS PRODUCT APPROVALS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-02-25 Cont ID  
Sent By btrobaug Date 2003-02-28 Time 16:06 Rev Time 0.50
Received By jgomez Date 2003-02-25 Time 16:04 Sent To  
Notes
2003-02-25 00:00:00STORM SHUTTERS SUBMITTAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-02-25 Cont ID  
Sent By jgomez Date 2003-02-05 Time 13:44 Rev Time 3.50
Received By jgomez Date 2003-02-05 Time 13:44 Sent To  
Notes
2003-02-05 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS PRIOR TO INSTALLATION.
 2-PROVIDE PRODUCT APPROVAL FOR FIXED
 WINDOWS WITH LARGE SIZES AS SHOWN ON
 PLANS.
 3-GARAGE DOOR: PROVIDE COPIES OF DRAWING
 P-1372 AS SELECTED ON TABLE 1 OF SBCCI
 PRODUCT APPROVAL REPORT. (DRAWING SUB-
 MITTED IF FOR ANOTHER TYPE OF DOOR)

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-01-29 Cont ID  
Sent By dpalmer Date 2003-02-04 Time 13:19 Rev Time 3.50
Received By jgomez Date 2003-01-29 Time 14:12 Sent To  
Notes
2003-01-29 00:00:00BUILDING REVIEW CHECKLIST:
 1-AREA CALCULATIONS ARE WRONG. REVISE AS
 REQUIRED CALCULATIONS ON SHEET A-4.
 2-REVISE DESIGN PARAMETERS CRITERIA ON
 SHEET A1.1. MEAN ROOF HEIGHT IS 22'-0"
 +/- NOT 18"-6". SEE BUILDING HEIGHT ON
 CHAPTER 2 DEFINITIONS OF FBC 2001.
 3-DESIGN PARAMETERS CRITERIA ON SHEET
 A1.1 IS MISSING THE +/- INTERNAL
 PRESSURES AS REQUIRED BY SECTION
 1606.1.7 FBC 2001.
 4-REVISE SPECIFICATIONS FOR CEILING
 INSTALLATION AT FRONT & REAR PORCHES.
 SEE ASTM C-926 AND ASTM C-1063 FOR
 PROPER FASTENING TYPE, SIZE & SPACING.
 (SEC. 2504.2 FBC 2001).
 5-SPECIFY SPACING FOR WWM SUPPORTS IN
 CONCRETE SLAB AS REQUIRED BY SECTION
 1909.3 FBC 2001.
 6-LIBRARY ROOM. PROVIDE EGRESS WINDOWS
 THAT COMPLY WITH SEC. 1005.4.4 FBC/01
 OR CLEARLY SPECIFY UNDER ROOM NAME
 THAT SUCH ROOM IS NOT TO BE USED FOR
 SLEEPING PURPOSES (AS PER BUILDING
 OFFICIAL INTERPRETATION).
 7-GLASS BLOCK IN MASTER BATHROOM TO BE
 SAFETY GLASS IF FACE THICKNESS IS LESS
 THAN 0.25". SEC. 2405.2.2 FBC 2001.
 8-COMPLETE STRUCTURAL BUCK DETAIL FOR
 GARAGE DOOR. SPECIFY SIZE OF WASHER.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 9-REVISE 2X STRUCTURAL BUCK DETAIL FOR
 DOOR TO COMPLY WITH SEC. 1707.4.4.2
 FBC 2001.
 10-STORM SHUTTERS: A)SEE LIMITATIONS ON
 PAGE 8 OF 8 OF PRODUCT APPROVAL REPORT
 TO VERIFY IF STRUCTURE PROVIDES REQ'D
 STRENGTH.
 B)PROVIDE COMPLETE INSTALLATION SCHED.
 USING CITY SAMPLE ATTACHED.
 C)CLEARLY MARK ON DRAWINGS SPECIFIC
 MOUNTING CONDITIONS AND ANCHOR TYPE &
 SPACING TO BE USED ACCORDING TO THE
 MEAN ROOF HEIGHT, DESIGN PRESSURES,
 EDGE DISTANCE, PANEL SPAN, CONNECTION
 TYPE AND STRUCTURE TO BE ATTACHED TO.
  
 11-PROVIDE PRODUCT APPROVAL FOR:
 A)GLASS BLOCK WITH CLEAR DRAWINGS.
 B)WINDOW MULLIONS.
 C)FIXED WINDOW SIZE AS CALLED FOR LIVING
 D)GARAGE DOORS: CLEARLY MARK ON DRAWINGS
 MODEL TO BE USED AND CHECK THE DESIGN
 PRESSURES CALCULATED BY THE ARCHITECT.
  
 12-TYPICAL WALL SECTION ON SHEET AS1:
 REVISE ATTIC INSULATION VALUE. SEE THE
 ENERGY CALCULATIONS.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-01-27 Cont ID  
Sent By hmoser Date 2003-01-21 Time 19:25 Rev Time 0.33
Received By dpalmer Date 2003-01-27 Time 06:15 Sent To B
Notes
2003-01-27 00:00:00************ PROVISO/ NOTE **********
  
 1)NOTE: PLEASE LIST THE REQ`D ARC FAULT
 CIRCUITS ON PANEL SCHEDULE. 210-12
  
 PLEASE REVISE AND SUBMIT FOR REVIEW
 BEFORE ROUGH ELECTRICAL INSPECTION.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-04-28 Cont ID  
Sent By shernand Date 2003-04-28 Time 11:49 Rev Time 0.00
Received By shernand Date 2003-04-28 Time 11:49 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-02-28 Cont ID  
Sent By btrobaug Date 2003-02-28 Time 16:05 Rev Time 0.00
Received By btrobaug Date 2003-02-28 Time 16:05 Sent To B
Notes
2003-02-28 00:00:00TO JULIO./WRT

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-02-18 Cont ID  
Sent By dpalmer Date 2003-02-18 Time 17:01 Rev Time 0.00
Received By dpalmer Date 2003-02-18 Time 17:01 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-04 Cont ID  
Sent By dpalmer Date 2003-02-04 Time 13:19 Rev Time 0.00
Received By dpalmer Date 2003-02-04 Time 13:19 Sent To B
Notes
2003-02-04 00:00:00TO JULIO GOMEZ'S DESK.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-05-01 Cont ID  
Sent By pkrauss Date 2003-05-01 Time 15:03 Rev Time 0.30
Received By pkrauss Date 2003-05-01 Time 14:52 Sent To  
Notes
2003-05-01 00:00:00MECH REV PERMIT 03021621

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-01-21 Cont ID  
Sent By shernand Date 2003-04-28 Time 11:49 Rev Time 0.50
Received By hmoser Date 2003-01-21 Time 19:25 Sent To E
Notes
2003-01-21 00:00:00PASS/PRIVISO
 1) REFER TO SECTION 601.4 BALANCED
 RETURN AIR
 2) REFER TO SECTION 403.3 VANTILATION
 RATE FOR BATHROOM EXHAUST
 3) TYPE OF VENTILATION USED FOR FRESH
 AIR.402NATURAL VENTILATION OR 403
 MECHANICAL VENTILATION.
 4) NEED CALCULATIONS ON TYPE OF
 VENTILATION USED
 5) NEED FAN SHUTDOWN FOR FINAL.
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-01-18 Cont ID  
Sent By sgraham Date 2003-01-15 Time 12:24 Rev Time 0.33
Received By jleech Date 2003-01-18 Time 12:14 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-01-15 Cont ID  
Sent By sgraham Date 2003-01-15 Time 12:23 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***