Plan Review Details - Permit 02120896
Plan Review Stops For Permit 02120896
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-06-12 Cont ID  
Sent By pkrauss Date 2003-05-20 Time 10:46 Rev Time 1.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-03-27 Cont ID  
Sent By pkrauss Date 2003-03-27 Time 11:33 Rev Time 1.50
Received By lsmith Date 2003-03-27 Time 12:43 Sent To  
Notes
2003-03-27 00:00:00******************PROVISO***********
  
 1. RECORDED NOTICE OF COMMENCEMENT MUST
 BE SUBMITTED BEFORE PERMIT IS ISSUED.
 2. PLANS MUST BE TAKEN TO PBC BUILDING
 DEPT & IMPACT FEES PAID FOR ADDITIONAL
 LIVING AREA AND STAMPED.
 3. PRODUCT APPROVALS MUST BE SUBMITTED
 FOR THE FRENCH DOORS AND WINDOWS BEFORE
 INSTALLATION.
 4. CORRECT ENERGY CODE FORM MUST BE
 SUBMITTED SHOWING TOTAL SQ. FOOTAGE FOR
 A/C NOT JUST ADDITION SINCE EXISTING
 UNIT SERVES NEW ADDITION AND EXISTING.
 SPACE. FORM MUST BE SIGNED BY PREPARER.
 5. DESIGN CERTIFICATION MUST MEETWIND
 ZONE OF 140 MPH.
 6. 2 COPIES OF SUBMITTALS MUST BE
 SUBMITTED.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-01-27 Cont ID  
Sent By dpalmer Date 2002-12-30 Time 15:55 Rev Time 1.00
Received By lsmith Date   Time   Sent To  
Notes
2003-01-27 00:00:00*******************FAILED**************
  
 1. PLANS MUST MEET FBC 2001.
 2. DESIGN CERTIFICATION MUST MEET
 140MPH PER FBC2001.
 3. ALL WINDOWS & DOORS MUST HAVE
 SUBMITTAL OF PRODUCT APPROVALS FROM
 SBCCI OR DADE COUNTY OR SITE SPECIFIC
 ENGINEERING SIGNED BY THE DESIGNER OF
 RECORD BOTH FOR THE DESIGN OF THE
 WINDOW AND/OR DOOR AND AT THE ADDRESS
 OF THE PLANS.
 4. PLANS SUBMITTED ARE NOT SIGNED &
 SEALED BY DESIGN PROFESSIONAL.
 5. ALL CHANGES ON PLANS (HANDWRITTEN)
 MUST BE INITIALED BY THE DESIGN
 PROFESSIONAL.
  
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 659-8096 EXT. 8394

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-05-01 Cont ID  
Sent By dpalmer Date 2003-05-01 Time 16:34 Rev Time 0.33
Received By dpalmer Date 2003-05-01 Time 16:34 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-03-25 Cont ID  
Sent By shernand Date 2003-04-30 Time 14:44 Rev Time 0.50
Received By dpalmer Date 2003-03-25 Time 13:38 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-12-30 Cont ID  
Sent By sthyng Date 2003-03-20 Time 11:46 Rev Time 0.50
Received By dpalmer Date 2002-12-30 Time 15:21 Sent To B
Notes
2002-12-30 00:00:00************** UNSAT *****************
  
 1)NOTE: PLEASE NOTE, PER FS/FAC PLANS
 ARE REQ`D TO BE SIGNED, DATED AND SEALED
 BY THE ENGINEER OF RECORD.471.025/
  
 2)NOTE: PLEASE NOTE, MISSING GFI FOR
 BATHROOM, MUST BE 20A AND #12.
 210-52D/210-11-C3 PLEASE LIST ON PANEL
 SCHEDULE.
 3)NOTE: PLEASE NOTE MISSING RECEPT
 210-52
  
 4)NOTE: PLEASE NOTE MISSING SD`S INSIDE
 AND OUTSIDE BEDROOM . NFPA-72 8-4.1.2
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-06-05 Cont ID  
Sent By shernand Date 2003-06-05 Time 13:57 Rev Time 0.00
Received By shernand Date 2003-06-05 Time 13:57 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-05-28 Cont ID  
Sent By shernand Date 2003-05-28 Time 16:59 Rev Time 0.00
Received By shernand Date 2003-05-28 Time 16:59 Sent To P
Notes
2003-05-28 00:00:00KSTEVENS DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-04-30 Cont ID  
Sent By shernand Date 2003-04-30 Time 14:42 Rev Time 0.00
Received By shernand Date 2003-04-30 Time 14:42 Sent To E
Notes
2003-04-30 00:00:00DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-03-20 Cont ID  
Sent By sthyng Date 2003-03-20 Time 11:46 Rev Time 0.00
Received By sthyng Date 2003-03-20 Time 11:46 Sent To E
Notes
2003-03-20 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2002-12-23 Cont ID  
Sent By dpalmer Date 2002-12-23 Time 13:09 Rev Time 0.00
Received By dpalmer Date 2002-12-23 Time 13:09 Sent To P
Notes
2002-12-23 00:00:00BACK FROM ZONING, TO PLUMB INBOX.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-19 Cont ID  
Sent By dpalmer Date 2002-12-19 Time 12:01 Rev Time 0.00
Received By dpalmer Date 2002-12-19 Time 12:01 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-05-20 Cont ID  
Sent By pkrauss Date 2003-05-20 Time 10:45 Rev Time 0.20
Received By pkrauss Date 2003-05-20 Time 10:41 Sent To B
Notes
2003-05-20 00:00:00PLANS APPROVED 3-27-03 - NO CHANGES ON
 THE RESUBMITTAL.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-03-27 Cont ID  
Sent By kstevens Date 2003-05-17 Time 17:43 Rev Time 0.35
Received By pkrauss Date 2003-03-27 Time 11:33 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-12-26 Cont ID  
Sent By pschmitz Date 2002-12-23 Time 14:43 Rev Time 0.20
Received By pkrauss Date 2002-12-26 Time 08:47 Sent To E
Notes
2002-12-26 00:00:00NO MECHANICAL INFORMATION SUBMITTED FOR
 REVIEW.
  
 PROVIDE INFORMATION ON EXISTING HVAC
 EQUIPMENT (MAKE, MODEL, BTU'S OF AHU, &
 SEER OF CONDENSING UNIT).EXISTING
 LIVING AREA IS 846 SQ FT, PROPOSED
 LIVING AREA IS 724 SQ FT, IS THE
 EXISTING HVAC EQUIPMENT ABLE TO PROVIDE
 THE REQUIRED COOLING?PROVIDE MANAUL
 J CALCS.
  
 PROVIDE INFORMATION ON THE EXHAUST
 FAN INDICATED FOR THE BATHROOM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 5 Status P Date 2003-06-11 Cont ID  
Sent By kstevens Date 2003-06-11 Time 05:49 Rev Time 0.33
Received By kstevens Date 2003-06-11 Time 05:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2003-06-02 Cont ID  
Sent By shernand Date 2003-06-05 Time 13:57 Rev Time 0.50
Received By kstevens Date 2003-06-02 Time 13:06 Sent To  
Notes
2003-06-02 00:00:00DENIED
 REFERENCE: FLORIDA STATUTES.
  
 1) RESUB IS A COPY, ORIGINAL SIGNATURE
 AND SEAL WITH DATE REQD. 61G15-23.002
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 3 Status F Date 2003-05-17 Cont ID  
Sent By shernand Date 2003-05-28 Time 16:59 Rev Time 0.25
Received By kstevens Date 2003-05-17 Time 17:43 Sent To M
Notes
2003-05-17 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS. 909.1 ONLY FIXTURES
 IN THE BATHROOM GROUP SHALL DRAIN INTO
 THE HORIZONTAL WET VENT. WASH MACHINE
 SHALL DRAIN DOWNSTREAM OF THE BATHROOM
 FIXTURES.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-03-25 Cont ID  
Sent By dpalmer Date 2003-05-01 Time 16:34 Rev Time 0.33
Received By kstevens Date 2003-03-25 Time 18:23 Sent To M
Notes
2003-03-25 00:00:00RESTAMP OK - REVISION REQUIRED

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-12-23 Cont ID  
Sent By dpalmer Date 2002-12-23 Time 13:10 Rev Time 0.66
Received By pschmitz Date   Time   Sent To M
Notes
2002-12-23 00:00:00PROVISO: NO HORIZONTAL DRY VENTS, PES.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-12-23 Cont ID  
Sent By dpalmer Date 2002-12-19 Time 12:01 Rev Time 0.25
Received By sgraham Date   Time   Sent To B
Notes
***NONE***