| 2003-01-21 00:00:00 | BUILDING REVIEW COMMENTS: |
| | 1-REVISE ENERGY CALCULATIONS: |
| | A)SEE PLANS FOR NUMBER OF BEDROOMS. |
| | B)COMPLETE TOP OF FORM. EG: ADDRESS, |
| | OWNER'S NAME, ETC. SEE FORM. |
| | C)OWNER/AGENT SIGN & DATE BOTTOM OF FORM |
| | |
| | 2-34SH WINDOWS DON'T PROVIDE 24' CLEAR |
| | HEIGHT OPENING REQ'D BY SEC. 1005.4.4 |
| | FBC 2001. CLARIFY/REVISE AS REQUIRED. |
| | ARE THESE CUSTOM MADE WINDOWS? |
| | 3-SPECIFY SAFETY GLASS WHERE REQUIRED. |
| | SEE PLANS AND SEC. 2405.2.2 FBC 2001. |
| | 4-PROVIDE SOIL TEST REPORT. |
| | 5-PROVIDE DETAIL/SPECIFICATIONS FOR |
| | INSTALLATION OF CEILING AT FRONT AND |
| | REAR PORCH AS REQUIRED BY ASTM C926 |
| | AND ASTM C-1063.(SEC. 2504.2 FBC 2001) |
| | 6-SPECIFY SIZE OF ATTIC VENT. SECTION |
| | 2309.6 FBC 2001. |
| | 7-TYPICAL WALL SECTION. SPECIFY FIREBLOC |
| | KING. SEC. 2305.1.4 FBC 2001. |
| | **PROVIDE GENERAL SPECIFICATIONS FOR |
| | FIREBLOCKING AT ALL CONCEALED SPACES |
| | AS REQUIRED BY SEC. 2305.1.4 FBC 2001. |
| | 8-SPECIFY SUPPORTS FOR WWM IN CONCRETE |
| | SLAB. SEE SEC. 1909.3 FBC 2001. |
| | 9-ADDRESS IS INCORRECT IN THE NOTICE OF |
| | COMMENCEMENT. REVISE STREET AS REQ'D. |
| | 10-PROVIDE COMPLETE INFORMATION FOR |
| | STORM SHUTTERS: |
| | A)PROVIDE KEY PLAN. |
| | B)PROVIDE INSTALLATION SCHEDULE. SEE |
| | ATTACHED CITY SAMPLE. |
| | C)CLEARLY MARK ON DRAWINGS SPECIFIC |
| | MOUNTING CONDITIONS AND ANCHOR TYPE & |
| | SPACING TO BE USED ACCORDING TO THE |
| | MEAN ROOF HEIGHT, DESIGN PRESSURES, |
| | EDGE DISTANCE, PANEL SPAN, CONNECTION |
| | TYPE AND STRUCTURE TO BE ATTACHED TO. |
| | |
| | 11-PROVIDE PRODUCT APPROVAL FOR GARAGE |
| | DOORS WITH LEGIBLE DRAWINGS. |
| | 12-PRODUCT APPROVAL FOR ARCHED WINDOWS: |
| | A)NEED LEGIBLE DRAWINGS. |
| | B)MISSING PAGE 2 OF THE REPORT. |
| | C)CHECK DESIGN PRESSURES CALCULATED BY |
| | THE ENGINEER OF RECORD. |
| | 13-RECTANGULAR WINDOW PRODUCT APPROVAL: |
| | A)NEED LEGIBLE DRAWINGS. |
| | B)PROVIDE PRODUCT APPROVAL FOR WINDOW |
| | SIZES AS SHOWN ON PLANS. |
| | C)PROVIDE STRUCTURAL BUCK DETAIL USING |
| | A 2X BUCK AS REQ'D ON THIS APPROVAL. |
| | 14-PROVIDE COMPLETE PRODUCT APPROVAL |
| | REPORT AND DRAWINGS FOR CEMENT TILE. |
| | 15-PROVIDE SBCCI OR DADE COUNTY PRODUCT |
| | APPROVAL FOR ENTRY DOORS, AND EXTERIOR |
| | SWING DOORS AS SHOWN ON PLANS. |
| | **BROWARD COUNTY PRODUCT APPROVALS ARE |
| | NOT ACCEPTED IN THIS OFFICE. |
| | 16-CLARIFY WHY THERE IS NOT A THICKENED |
| | REINFORCED EDGE AT FOYER RECESS. |
| | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. |
| | 17-SHEET #2 OF 5: UPDATE/REVISE NOTE #3. |
| | SEE SEC. 2306.1 CITY AMENDMENTS TO FBC |
| | 2001 FOR FASTENER SPACING @ ZONE 3. |
| | 18-OWES $484.12 FOR UPDATED VALUE AND |
| | RADON FEES. |
| | 19-ENGINEER OF RECORD TO PROVIDE ALL HIS |
| | INFORMATION AS REQUIRED BY CHAPTER 471 |
| | FLORIDA STATUTES WHEN SUBMITTING |
| | INFORMATION FOR PUBLIC RECORDS. |
| | 20-REVISE/UPDATE SURVEY. PROPERTY IS |
| | LOCATED ON FLOOD ZONE "B", NOT 'A8" |
| | AS PER LETTER OF MAP REVISION DATED |
| | DECEMBER, 3RD 1985. |
| | |
| | |
| | NOTES: |
| | **SEE COMMENTS BY THE OTHER TRADES. |
| | **PLEASE, RETURN SETS AFTER CORRECTIONS |
| | ARE DONE TO THE ORIGINAL CAD DRAWINGS |
| | TO EXPEDITE THE REVIEW PROCESS. |