| Plan Review Stops For Permit 02120463 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-09-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-14 |
Time |
12:27 |
Rev Time |
0.88 |
| Received By |
jwitmer |
Date |
2003-09-22 |
Time |
17:54 |
Sent To |
|
|
| Notes |
| 2003-09-22 00:00:00 | 09-22-03 | | | BUILDING PROVISO | | | PERMIT:02120463 | | | 712 PARK PLACE | | | | | | 1)1507.3.8. ASPHALT SHINGLES LOW | | | SLOPE ROOFING, UNDERLAYMENT APPLICATION | | | FOR ROOF SLOPES FROM 2:12 UP TO 4:12, | | | UNDERLAYMENT SHAL BE A MINIMUM OF TWO | | | LAYERS APPLIED AS FOLLOWS: | | | 1) STARTING AT THE EAVE, A 19-INCH | | | STRIP OF UNDERLAYMENT SHALL BE APPLIED | | | PARALLEL WITH THE EAVE AND FASTENED | | | SUFFICIENTLY TO STAY IN PLACE. | | | 2) STARTING AT THE EAVE, 36-INCH-WIDE | | | STRIPS OF UNDERLAYMENT FELT SHALL BE | | | APPLIED OVER LAPPING SUCCESSIVE SHEETS | | | 19 INCHES AND FASTENED SUFFICIENTLY TO | | | STAY IN PLACE. | | | | | | 2) PROVIDE A UPDATED NOTICE OF COMMENCE- | | | MENT. | | | | | | 3) PROVIDE PERMIT APPLICATION OR PROVIDE | | | A NEW COPY. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-09-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-09-22 |
Time |
15:12 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2003-09-22 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2003-09-22 00:00:00 | REV# 4 ADDITION OF WINDOWS TO MASTER | | | BEDROOMJW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-01-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-09-17 |
Time |
09:26 |
Rev Time |
3.50 |
| Received By |
jwitmer |
Date |
2003-01-27 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2003-01-27 00:00:00 | | | | BUILDING PLAN REVIEW | | | PERMIT: 02120463 | | | ADD:712 PARK PLACE | | | CONT: SERRAES CONSTRUCTION | | | TEL: (561)848-6607 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1) THE ONLY ADDRESS ON FILE FOR THIS PRO | | | PERTY IS 712 PARK PLACE. TO RECEIVE A | | | ADDRESS FOR THE BACK UNIT THE OWNER MUST | | | REQUEST FOR THE ADDITIONAL ADDRESS FOR | | | THE BACK UNIT, THEN ONCE THIS REQUEST | | | HAS BEEN RESEARCHED THE ADDRESS WOULD | | | BE GIVEN TO THE BACK UNIT. | | | | | | 2)FIGURE 1606 WIND-BORNE DEBRIS | | | REGION; INDICATES THAT W.P.B. CITY OF IS | | | LOCATED IN THE 140 MPH ZONE. PLANS ARE | | | TO INDICATE THIS. | | | | | | 3)FL. BLD CODE 1606.1.7 THE FOLLOWING | | | INFORMATION RELATED TO WIND SHALL BE | | | SHOWN ON THE CONSTRUCTION DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | | | | 4)1606.1.1(6) SUBJECT TO THE LIMITATIONS | | | OF 1606.1.1.1, 1606.1.4 AND 1606.1.6, | | | THE PROVISIONS OF THE FC &PA GUIDE TO | | | CONCRETE MASONRY RESIDENTIAL CONSTRUC- | | | TION IN HIGH WIND AREA SHALL BE PERMIT- | | | TED FOR APPLICABLE CONCRETE MASONARY | | | BUILDINGS OF A GROUP R3 OCCUPANCY FOR A | | | WIND SPEED OF 130 MPH OR LESS IN EXPOS- | | | URE B OR 110 MPH OR LESS IN EXPOSURE C. | | | THE 2001 FL. CODE REQUIRES A DESIGN | | | PROFESSIONAL ENG. OR ARCH. TO DESIGN | | | MASONARY BUILDINGS IN A 140 MPH WINDZONE | | | | | | 5)PROVIDE ENERGY CALCULATIONS AND | | | EQUIPMENT SIZING CALCULATIONS (MANUAL J) | | | AS REQUIRED BY THE 2001 FLORIDA ENERGY | | | EFFICIENTCY CODE FOR BUILDING CONSTRUC- | | | TION. FORM 600B-01, ZONE SOUTH 7,8,& 9. | | | | | | 6) PAGE 3 INDICATES A 8"X12" CONCRETE | | | BEAM WITH 2 # 5'S/ THE DRAWING INDICATES | | | 4 REBARS, THE SPAN IS APPROX. 10'-0" | | | WITH OUT ANY STIRRUPS? ACI 530 7.5.3.1 | | | SHEAR REINFORCEMENT SHALL BE PROVIDED | | | PARALLEL TO THE DIRECTION OF APPLIED | | | FORCE. SPACING OF SHEAR REINFORCEMENT | | | SHALL NOT EXCEED THE LESSER OF D/2 OR | | | 48". | | | | | | 7)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | PAGE 12 INDICATES A 2X8 NAILER(PT) TO BE | | | FASTENED TO A MASONARY WALL, THE PLAN | | | DOES NOT INDICATE IS THIS BLOCK, A BEAM? | | | THE PLAN CALLS FOR TAP-INS, SIMPSON DOES | | | NOT CALL ANY OF THERE FASTENERS BY THIS | | | NAME, PROVIDE A MODEL NUMBER? THE SPAC- | | | ING CALLS OUT FOR A 4'-0" SPACING? GIVE | | | CALCULATIONS FOR THE ANCHOR TO BE USED, | | | INDICATING THE TRIBUTARY AREA & LOADING? | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)659-8096 X8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
N |
Date |
2006-06-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-19 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-19 |
Time |
16:22 |
Sent To |
PC |
|
| Notes |
| 2006-06-19 00:00:00 | PANEL SCHEDULE SUBMITTAL NOT REVIEWED, | | | TO BE REVISED AT LATER DATE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-12 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-12 |
Time |
12:22 |
Sent To |
PC |
|
| Notes |
| 2006-06-12 00:00:00 | REVISED KITCHEN. | | | REDLINED 210.52C1-5 | | | | | | PANEL SCHEDULE SUBMITTED NOT PART OF | | | STAMPED REVS', AS IT DOES NOT MEET 408.4 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-18 |
Time |
18:57 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-05-18 |
Time |
18:09 |
Sent To |
PC |
|
| Notes |
| 2006-05-18 00:00:00 | DENIED | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} IF THE CUT OF THE KITCHEN SUBMITTED | | | PREVIOUSLY (3/15/06) IS TO BE REVIEWED | | | WITHTHIS REVISION, PLEASE SIGN SAME PER | | | 104.2.1 FBC. ALSO INDICATE GFI'S PER | | | 210.8(A)(6)ON THE PLAN. THE ADDRESS IS | | | WRONG ON THAT SHEET STILL. | | | | | | 2} ALL 15 AMP BREAKERS ON THE PANEL | | | SCHEDULE ARE FEEDING # 16 WIRE. | | | SEE310.16 FOR CORRECT CONDUCTOR SIZES | | | FOR OCP. | | | | | | THIS REVISION IS NOT A SUBMITTAL AND HAS | | | A FEE DUE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-23 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-23 |
Time |
07:14 |
Sent To |
PC |
|
| Notes |
| 2006-03-23 00:00:00 | ************* UNSAT ************* | | | | | | ** PLEASE SEE SOME NOTES NEED TO BE | | | CORRECTED AND ALSO SEE BELOW FROM REVIEW | | | DATED ON 10/8/03 WHICH WERE NEVER | | | SUBMITTED FOR INFORMATION REQUIRED. | | | PLEASE KNOW, NO FURTHER ELECTRICAL | | | REVISIONS CAN BE DONE UNTIL ALL MIN FROM | | | OCT 2003 AND RECENT REV'S ARE SUBMITTED. | | | | | | | | | 1)NOTE: PLEASE SEE ADDRESSING ON PLANS | | | SHALL CORRELATE WITH APPLICATION AND OUR | | | SYSTEM IN WHICH THE PERMIT WAS PULLED. | | | THIS ADDRESS IS FOR 712, NOT 710 WHICH | | | IS NOT WHAT THIS PERMIT WAS PULLED FOR. | | | | | | 2)NOTE: PLEASE CORRELATE KITCHEN PLANS | | | SUBMITTED. ONLY ONE LAYOUT IS NEEDED FOR | | | CODE COMPLIANCE. | | | | | | | | | 3)NOTE: PLEASE SEE 210.52C1 FOR SPACING. | | | | | | 4) NOTE: PLEASE SEE 210.8A6, AS ALL | | | COUNTER SPACE RECEPTS IN KITCHENS SHALL | | | BE SHOWN AS GFI/ GFI PROTECTED. IF ANY | | | RECEPTS ARE DEDICATED (IE:) MICRO, DISP | | | ETC, PLEASE IDENTIFY. | | | | | | 5)NOTE: PLEASE SEE PLANS MENTIONS DRAWN | | | BY AND CONTAINS THE PRINTED NAME, | | | HOWEVER PLANS ARE ALSO REQUIRED TO BE | | | SIGNED BY THAT PERSON. | | | FBC ADMIN SECTION 104.2.1 | | | | | | 6)NOTE: PLEASE SEE SOME ROOMS WHERE THE | | | PLANS INDICATE THE ENTIRE RECEPT BEING | | | SWITCH. PLEASE KNOW, THIS IS ONLY | | | PERMITTED IF AN ADDITIONAL RECEPT MEETS | | | 210.52. IF INDEED THESE ARE 1/2 SWITCH? | | | PLEASE INDICATE. | | | | | | 7) NOTE: PLEASE SEE NEC 210.12, PLANS | | | INDICATE ARC FAULT FOR RECEPTS, WHICH IS | | | OK AS THESE PLANS ORIGINALLY CAME IN | | | UNDERTHE PREVIOUS REQUIREMENTS FOR | | | AFCI PROTECTION, HOWEVER PLEASE SEE | | | PLANS LENDS TO THE RECEPTS BEING PART OF | | | THE LIGHTING CIRCUITS, WHICH WOULD THEN | | | REQUIRE AFCI PROTECTION. PLEASE SEE RMS | | | ARE BEING SHOWN WITH A SWITCHED LT | | | FIXTIURE (NO FANS) AND SWITCHED RECEPTS. | | | WHEN PANEL SCHEDULE AS REQUIRED IS | | | SUBMITTED, THIS WILL BE VERIFIED. PLEASE | | | SEE NOTES BELOW. | | | | | | ** NOTES FROM 10/8/03** | | | | | | ************ NOTES REDLINED ******* | | | | | | PANELSCHEDULE WITH ALL OCP SIZES AND | | | WIRE SIZES TO BE REVISED AND SUBMITTED | | | BEFORE FINAL. | | | SEE 250.32 FOR GROUNDING AT TWO OR MORE | | | BDLGS. | | | PLEASE SUBMIT ALL OTHER REVISIONS BEFORE | | | ROUGH, AS STAMPED ON PLANS. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | **************************************** | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-10-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-08 |
Time |
07:24 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-10-08 |
Time |
07:01 |
Sent To |
M |
|
| Notes |
| 2003-10-08 00:00:00 | ************ NOTES REDLINED ******* | | | | | | PANELSCHEDULE WITH ALL OCP SIZES AND | | | WIRE SIZES TO BE REVISED AND SUBMITTED | | | BEFORE FINAL. | | | SEE 250.32 FOR GROUNDING AT TWO OR MORE | | | BDLGS. | | | PLEASE SUBMIT ALL OTHER REVISIONS BEFORE | | | ROUGH, AS STAMPED ON PLANS. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-09-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-03 |
Time |
15:46 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-09-15 |
Time |
06:50 |
Sent To |
P |
|
| Notes |
| 2003-09-15 00:00:00 | ************* UNSAT ****************** | | | | | | 1)NOTE: PLEASE SEE THAT ORIG PERMIT | | | APPLICATION DID NOT COME BACK IN W/ | | | PACKAGE. PLEASE SUBMIT PERMIT APPL. | | | PLEASE ALSO SEE THAT PLANS ARE STILL | | | SHOWING 710 PARK PL??? PERMIT APPL AND | | | PROPERTY ID USED IS FOR 712 PK PL?? | | | PLEASE SEE THAT WORK WAS ALREADY DONE ON | | | 712 ON PREVIOUS PERMITS? | | | PLEASE CORRELATE AND CORRECT. | | | | | | 2)NOTE: PLEASE SEE THAT NOC SUBMITTED | | | HAS SINCE EXPIRED. NOC IOS FROM JAN 2001 | | | A NEW RECORDED NOC WILL BE REQ'D BEFORE | | | PICKING UP PERMIT. | | | | | | 3)NOTE: PLEASE SEE THAT SD'S ARE STILL | | | MISSING INSIDE BEDROOMS, INCLUDING DEN, | | | WHICH IS AN ADAPTABLE BEDRM. | | | NFPA-72 | | | | | | 4)NOTE: PLEASE SEE THAT PLANS NEED TO BE | | | STAMPED FROM HISTORIC AGAIN. NEW SETS | | | WERE SUBMITTED AND CHANGES MADE. ALSO | | | NEEDS TO GO BACK TO OTHER TRADES DUE TO | | | NEW PLANS AND CHANGES MADE. | | | | | | 5)NOTE: PLEASE SEE MISSING RECEPT ON | | | KITCHEN COUNTERSPACE PER 210.52C1 | | | NEXT TO STOVE. | | | | | | 6)NOTE: PLEASE SEE THAT LOAD CALCULATION | | | -S WERE NOT SUBMITTED AND MISSING FROM | | | SETS? 215.5 | | | PLEASE SHOW SERVICE LOCATION."ON MAIN | | | HOUSE? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | PLEASE SEE THAT ONLY A 90 DAY EXTENTION | | | HAS BEEN GRANTED BY THE BLDG OFFICAL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-01-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-10 |
Time |
11:01 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-01-03 |
Time |
06:51 |
Sent To |
P |
|
| Notes |
| 2003-01-03 00:00:00 | ************* UNSAT *************** | | | | | | PLEASE NOTE, ADDRESS ON PLANS SHOW 710 | | | PARL PL.? PLEASE NOTE SURVEY AND LEGAL | | | ADDRESS FOR BLDG IN PALM BEACH PROPERTY | | | APPR. OFFICE IS LISTED AS 712? PLEASE | | | CLARIFY HOW THIS KEEPS BEING APPLIED FOR | | | UNDER 710? | | | PLEASE ALSO NOTE CODES HAVE CHANGED | | | SINCE THIS FIRST CAME IN, WHICH WILL | | | HAVE AN AFFECT ON OTHER TRADES AND | | | REVIEW COMMENTS ORIGINALLY SET FORTH | | | UNDER OLD PERMIT # WHICH EXPIRED. | | | | | | 1)NOTE: PLEASE NOTE MISSING SD AT THE | | | LOWER LEVEL IN THE VICINITY OF STAIRS. | | | NFPA-72 8-1.4 | | | PLEASE ALSO NOTE MISSING TWO SD'S ON | | | SECOND FLR, OUTSIDE BEDROOMS AND SD | | | THAT NEEDS TO MOVED TO UPPER LEVEL OF | | | STAIRS OUTSIDE SLEEPING ROOMS.NFPA-72 | | | | | | 2)NOTE: PLEASE CLARIFY WHAT APPEARS TO | | | BE AN "ISLAND IN KITCHEN? IF SO, PLEASE | | | SEE 210-52-C-2 ALSO TO BE GFI. | | | | | | 3)NOTE: PLEASE CLARIFY PLANS SHOWING | | | ALL GFI RECEPTS IN BEDROOMS? SINCE PLANS | | | FIRST CAME THROUGH FOR REVIEW. AS OF | | | JAN 1ST 2002, ARC FAULT BRKRS ARE REQ`D | | | FOR ALL BEDROOM CIRCUITS AND ARE LISTED | | | ON PANEL SCHEDULE. PER 210-12 NEC. | | | | | | 4)NOTE: PLEASE CLARIFY HOW 2-5KW HEAT | | | STRIPS ARE SHOWN AS 5600W ON LOAD CALCS? | | | | | | 5)NOTE: PLEASE CLARIFY EQUIPMENT OUTSIDE | | | GUEST RM. SHOWS A 220V AND 120V RECEPT? | | | PLEASE NOTE, 2 AHU`S ARE ALREADY SHOWN. | | | | | | JUST A NOTE, IF THERE ARE GOING TO BE | | | ANY CATV, TELEPHONE ORLOW SYSTEMS | | | INSTALLED, PLEASE SHOW ON PLANS IN | | | ORDER TO BE INCLUDED ON THIS APPLICATION | | | PLEASE NOTE, IF DONE AT LATER DATE, | | | SEPARATE PERMIT APPLICATION/PLANS WILL | | | BE REQ`D. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-19 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-19 |
Time |
15:34 |
Sent To |
E |
|
| Notes |
| 2006-06-19 00:00:00 | TO "DPALMER' DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-05-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-17 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-17 |
Time |
15:24 |
Sent To |
E |
|
| Notes |
| 2006-05-17 00:00:00 | TO "DPALMER' DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-03-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-17 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-17 |
Time |
10:14 |
Sent To |
E |
|
| Notes |
| 2006-03-17 00:00:00 | TO "DPALMER' DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-06 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-06 |
Time |
10:58 |
Sent To |
M |
|
| Notes |
| 2005-07-06 00:00:00 | TO "PKRAUSS" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-10-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-03 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-03 |
Time |
15:44 |
Sent To |
E |
|
| Notes |
| 2003-10-03 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-09-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-10 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-10 |
Time |
11:01 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-08-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-26 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-26 |
Time |
11:55 |
Sent To |
E |
|
| Notes |
| 2003-08-26 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-01-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-02 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
E |
|
| Notes |
| 2003-01-02 00:00:00 | TO DV PALMER'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-12-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-05 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-12-05 |
Time |
17:30 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-07-14 |
Time |
10:33 |
Rev Time |
0.75 |
| Received By |
prafter |
Date |
2005-07-14 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2005-07-14 00:00:00 | MECH. PLAN REVISION: | | | | | | PROVISO:1. PROVIDE FOR AUX. DRAIN | | | PANS WITH PROTECTION. 2003 FBC/M 307.2.3 | | | . | | | | | | 2. DRYER VENT TO CONFORM WITH 2003 | | | FBC/M SECTION 504 . | | | | | | PAT RAFTER 561/805/6728 OR 8056719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-10-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-08 |
Time |
07:24 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2003-10-09 |
Time |
12:12 |
Sent To |
B |
|
| Notes |
| 2003-10-09 00:00:00 | PROVISO: | | | PLEASE NOTE, REVISION TO THE 2001 | | | FBC(M) 601.4, EFFECTIVE JUNE 30,2003: | | | | | | BALANCED AIR RETURN - RETURN/TRANSFER | | | SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL | | | AREA (SQ INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM ITS SERVING & THE | | | DOOR HAVING AN UNRESTRICTED 1" UNDERCUT. | | | | | | ALL SUPPLY AIR INTO THE MASTER SUITE | | | SHALL BE INCLUDED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-09-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-09-17 |
Time |
09:09 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-09-17 |
Time |
09:08 |
Sent To |
B |
|
| Notes |
| 2003-09-17 00:00:00 | PROVISO: | | | PROVIDE LOCATION, SIZE OF RETURN AIR | | | DUCT AND GRILLE FOR AHU #1. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-01-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-15 |
Time |
18:44 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-01-16 |
Time |
14:41 |
Sent To |
B |
|
| Notes |
| 2003-01-16 00:00:00 | MECHANICAL PERMIT 02120464 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-09-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-09-17 |
Time |
09:10 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-09-15 |
Time |
18:44 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-01-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-09-15 |
Time |
06:50 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-01-15 |
Time |
12:17 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-01-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-05 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
|
|