Plan Review Details - Permit 02120313
Plan Review Stops For Permit 02120313
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-04-21 Cont ID  
Sent By btrobaug Date 2003-04-21 Time 17:29 Rev Time 0.50
Received By btrobaug Date 2003-04-21 Time 17:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-12-31 Cont ID  
Sent By shernand Date 2003-04-18 Time 16:49 Rev Time 0.50
Received By btrobaug Date 2002-12-31 Time 11:41 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-04-18 Cont ID  
Sent By shernand Date 2003-04-18 Time 16:49 Rev Time 0.00
Received By shernand Date 2003-04-18 Time 16:49 Sent To E
Notes
2003-04-18 00:00:00BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-01-24 Cont ID  
Sent By dpalmer Date 2003-01-24 Time 12:13 Rev Time 0.00
Received By dpalmer Date 2003-01-24 Time 12:13 Sent To B
Notes
2003-01-24 00:00:00TO ROBERT MCDOUGALS DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2002-12-19 Cont ID  
Sent By dpalmer Date 2002-12-19 Time 10:38 Rev Time 0.00
Received By dpalmer Date 2002-12-19 Time 10:38 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-09 Cont ID  
Sent By btrobaug Date 2002-12-09 Time 13:18 Rev Time 0.00
Received By btrobaug Date 2002-12-04 Time 13:18 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-01-04 Cont ID  
Sent By btrobaug Date 2002-12-31 Time 12:19 Rev Time 0.50
Received By hmoser Date 2003-01-04 Time 09:49 Sent To R
Notes
2003-01-04 00:00:00PASS/PROVISO
 1) NEED HVAC.EFFICIENCY CARD POSTED ON
 A/C EQUIPMENT FOR FINAL
 2) NEED A/C EQUIPMENT SPECIFICATIONS
 FOR FINAL
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8221

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-12-28 Cont ID  
Sent By sgraham Date 2002-12-23 Time 12:48 Rev Time 0.33
Received By jleech Date 2002-12-28 Time 13:01 Sent To M
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2003-01-30 Cont ID  
Sent By rmcdouga Date 2003-01-30 Time 10:52 Rev Time 3.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-01-30 00:00:00BUILDING PROVISO
  
 1) PROVIDE A CORRECTED STORM PANEL
 INSTALLATION SCHEDULE.
  
 2)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR THE FOLLOWING PRIOR TO
 INSTALLING.
 - (FRONT DOOR) SINGLE OUTSWING DOOR WITH
 ONE SIDELITE
 - ARCHED TOP WINDOW (BEDROOM #2)

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2003-01-10 Cont ID  
Sent By hmoser Date 2003-01-04 Time 09:49 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-01-08 00:00:00BUILDING DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) THE ENERGY CALCULATION FORM IS
 REQUIRED TO BE SIGNED BY THE OWNER/AGENT
  
 3) THE UPLIFTS GIVEN ON THE ROOF FRAMING
 PLAN ON S2, EXCEED THE CAPACITIES OF THE
 SPECIFIED CONNECTORS AT SEVERAL
 LOCATIONS. SEE REDLINES ON PLANS.
  
 4) CLARIFY THE CONNECTOR AND THE UPLIFT
 FOR THE HIP GIRDER OVER THE GARAGE. THE
 OUTER END HAS 1588# OF UPLIFT AND B ON
 S2 CONNECTOR IS SPECIFIED. THE CONNECTOR
 OON THE OTHER END (ENTRY) IS A USP MSH
 WHICH HAS A UPLIFT CAPACITY OF 785#.
 PLEASE REVIEW.
  
 5) THE ROOF NAILING ZONE FOR THE GABLE
 END OVER BEDROOM #2 IS ZONE 3 FOR 4'
 FROM GABLE PLUS OVERHANG. PLEASE CORRECT
 THE DIAGRAM ON S2.
  
 6) ACCORDING TO THE STORM PANEL KEY PLAN
 UNITS 1 & 2 ON THE INSTALLATION SCHEDULE
 ARE REVERSED. UNIT 6 (2) SH 25 WITH 24"
 TRANSOM ABOVE HAS THE WRONG OPENING SIZE
 LISTED ON THE SCHEDULE. THE OPENING SIZE
 FOR UNIT 8 IS ALSO INCORRECT.
  
 7)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - SLIDING GLASS DOORS
 - SINGLE OUTSWING DOOR WITH ONE SIDELITE
 - ARCHED TOP WINDOW (BEDROOM #2)
  
 8) PROVIDE A SOIL BEARING TEST REPORT AS
 REQUIRED BY FBC 1804.2.2.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202
  
 659-8096 EXT.8202

Review Stop Z ZONING
Rev No 2 Status P Date 2002-12-23 Cont ID  
Sent By sgraham Date 2002-12-23 Time 12:48 Rev Time 0.25
Received By sgraham Date   Time   Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-12-12 Cont ID  
Sent By dpalmer Date 2002-12-19 Time 10:38 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-12-12 00:00:00DENIED, NEED SITE PLAN