Plan Review Details - Permit 02120164
Plan Review Stops For Permit 02120164
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-03-12 Cont ID  
Sent By dpalmer Date 2003-03-12 Time 05:36 Rev Time 0.25
Received By dpalmer Date 2003-03-12 Time 05:36 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-02-10 Cont ID  
Sent By jleech Date 2003-02-05 Time 18:47 Rev Time 0.30
Received By dpalmer Date 2003-02-10 Time 06:22 Sent To B
Notes
2003-02-10 00:00:00*********** UNSAT **************
  
 1)NOTE: PLEASE CORRELATE OCP/AWG WITH
 RISER DIAGRAM FOR SUB PANEL. PANEL "A"
 SHOWS 40A, #10,
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-01 Cont ID  
Sent By shernand Date 2003-07-01 Time 12:47 Rev Time 0.00
Received By shernand Date 2003-07-01 Time 12:47 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-01-23 Cont ID  
Sent By btrobaug Date 2002-12-04 Time 17:15 Rev Time 0.00
Received By btrobaug Date 2002-12-04 Time 17:15 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-07-03 Cont ID  
Sent By pkrauss Date 2003-07-03 Time 14:35 Rev Time 0.25
Received By pkrauss Date 2003-07-03 Time 14:35 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-03-15 Cont ID  
Sent By shernand Date 2003-07-01 Time 12:47 Rev Time 0.25
Received By hmoser Date 2003-03-15 Time 06:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-02-05 Cont ID  
Sent By dpalmer Date 2003-03-12 Time 05:36 Rev Time 0.33
Received By jleech Date 2003-02-05 Time 18:46 Sent To E
Notes
2003-02-05 00:00:00DENIED;
 PLAN DENIED
 1) ENERGY PERFORMANCE LEVEL DISPLAY CARD
 AND ENERGY CALCULATIONS DO NOT MATCH.
 2) EQUIPMENT SELESTION ON MANUAL (J) NOT
 COMPLETE.
 3) COOLING & HEATING BTU.ON MANUAL (J)
 DO NOTMATCH PLANS.
 PLAN REVIEW BY HAROLD MOSER
 (561)689-8096 EXT.8390

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-02-01 Cont ID  
Sent By sgraham Date 2003-01-24 Time 16:03 Rev Time 0.33
Received By jleech Date 2003-02-01 Time 11:34 Sent To M
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2003-03-05 Cont ID  
Sent By jgomez Date 2003-02-12 Time 11:13 Rev Time 2.00
Received By lsmith Date 2003-02-11 Time 17:53 Sent To  
Notes
2003-02-12 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 2-FLOOD ZONE A8: NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
 3-CLARIFY DETAIL S21 FOR COLUMN LOCATED
 BETWEEN GARAGE & STAIRWAY & SUPPORTING
 TWO GIRDER TRUSSES. HOW ARE TRUSSES
 SUPPORTED BY STRAPS ONLY?. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 4-34SH WINDOW DOESN'T PROVIDE THE 24"
 CLEAR HEIGHT REQUIRED BY SEC. 1005.4.4
 FBC 2001. IS IT A CUSTOM MADE WINDOW?
 CLARIFY.
 5-PROVIDE SOIL TEST REPORT PRIOR TO
 CONSTRUCTION.

Review Stop Z ZONING
Rev No 2 Status P Date 2003-01-24 Cont ID  
Sent By sgraham Date 2003-01-24 Time 16:03 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-12-12 Cont ID  
Sent By btrobaug Date 2003-01-23 Time 07:18 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-12-12 00:00:00DENIED NEED SITE PLAN