Plan Review Details - Permit 02120069
| Plan Review Stops For Permit 02120069 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-01-23 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2003-01-23 |
Time |
11:58 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-12-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-12-14 |
Time |
20:01 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-12-16 00:00:00 | BUILDING REVIEW NOTES: | | | | | | 1. NEED COPY OF CONTRACT TO VERIFY | | | VALUE FOR PERMIT. | | | 2. NEED DETAIL SHOWN ON DRAWINGS FOR | | | METHOD OF PROTECTING POOL AREA FROM | | | HOUSE PER FBC 424.2.17 | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 659-8096 EXT. 8394 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-12-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-11 |
Time |
07:02 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2002-12-11 |
Time |
07:02 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-12-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-02 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-12-02 |
Time |
17:35 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-05-27 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2003-05-27 |
Time |
10:56 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-05-27 00:00:00 | LETTER FROM ENGINEER RE: MAIN DRAIN | | | INSPECTION OK. PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-01-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-23 |
Time |
14:39 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2003-01-23 |
Time |
14:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-12-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-11 |
Time |
07:18 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2002-12-14 |
Time |
19:58 |
Sent To |
B |
|
| Notes |
| 2002-12-14 00:00:00 | DENIED | | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | | FORMATION REQUIRED FOR PLAN REVIEW | | | 1) FBC-2001 SEC 424.2.6.1 ENGINEERING | | | DESIGN, CONSTRUCTION AND WORKMANSHIP. | | | ANSI/NSPI-4 92, AND NSPI-5. (ADD TO | | | NOTES) | | | 2) FBC-2001424.2.6.6.5 WHERE PROVIDED, | | | THE VACUUM OR PRESSURE CLEANER FITTING | | | SHALL BE LOCATED AT LEAST 6" AND NOT | | | GREATER THAN 12" BELOW THE MINIMUM OPER- | | | ATING WATER LEVEL OR AS AN ATTACHMENT TO | | | THE SKIMMER. | | | 3) FBC-2001 424.2.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | | SHEETS REQUIRED. (SUBMITTAL) | | | 4) FBC-2001 424.2.14.2 WATER RETENTION, | | | PROVIDE A POSITIVE MEANS OF RETAINING | | | WATER IN THE HEATER WHEN PUMP IS SHUT | | | OFF. (MANUFACTURE CUT SHEETS SUBMITTAL) | | | 17) FBC-2001 424.2.14.4 CONNECTIONS, ALL | | | WATER HEATING EQUIPMENT SHALL BE INSTAL- | | | LED WITH FLANGES OR UNION CONNECTIONS | | | ADJACENT TO THE HEATER. (ADD TO NOTES) | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-12-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-02 |
Time |
17:36 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
| Notes |
|
|
|