Plan Review Details - Permit 02111671
Plan Review Stops For Permit 02111671
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-07-14 Cont ID  
Sent By jwitmer Date 2003-07-14 Time 10:25 Rev Time 0.75
Received By jwitmer Date 2003-07-14 Time 10:24 Sent To  
Notes
2003-07-14 00:00:00REV # 2 6/20/03 OKJW

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-03-19 Cont ID  
Sent By kstevens Date 2003-07-12 Time 08:18 Rev Time 0.15
Received By pkrauss Date 2003-03-19 Time 13:32 Sent To  
Notes
2003-03-19 00:00:00P/U PLANS 3-19-03 PAID IMPACT FEES.
 PLANS APPROVED BY J WITMER EXCEPT IMPACT
 FEES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-02-10 Cont ID  
Sent By jwitmer Date 2003-02-10 Time 13:52 Rev Time 1.27
Received By jwitmer Date 2003-02-10 Time 13:52 Sent To  
Notes
2003-02-10 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02111671
 ADD: 368 POTTER ROAD
 CONT: WIGHTMAN
 TEL: (561)644-3140
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ****DENIED****
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-12-23 Cont ID  
Sent By dpalmer Date 2003-02-10 Time 10:58 Rev Time 2.75
Received By jwitmer Date 2002-12-23 Time 13:29 Sent To  
Notes
2002-12-23 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02111671
 ADD: 368 POTTER RD
 CONT: WIGHTMAN CONSTRUCTION
 TEL: (561)906-0106
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2)1804.1.3 THE BOTTOM OF THE FOUNDA-
 TION SHALL EXTEND NO LESS THAN 12"
 BELOW FINISH GRADE.
  
 3)2304.5 CLEARENCE BETWEEN WOOD SIDING
 & EARTH ON THE EXTERIOR OF A BUILDING
 SHALL NOT BE LESS THAN 6" EXCEPT WHERE
 SIDING, SHEATHING AND FRAME WALL ARE OF
 APPROVED DURABLE WOOD OR APPROVED PRE-
 SERVATIVE TREAATED WOOD.
  
 4)1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST.
  
 5) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING REPORTS:
 A) FRENCH DOORS
 B) WINDOWS
 C) SKYLIGHTS
 D) STORM SHUTTERS REPORT SUBMITTED
 EXPIRED
 E) ROOFING REPORT
  
 6) 1707.4.3 EACH EXTERIOR DOOR
 ASSEMBLY NOT COVERED BY 1707.4.2
 (GLAZED DOORS) SHALL BE LISTED AND TEST-
 ED FOR A PERIOD EQUAL TO THE QUANITY
 3600/ V WHERE THE TIME PERIOD IS IN
 SECTIONS AND V IS IN MILES PER HR TAKEN
 FROM FIGURE 1606. THE TIME PERIOD SHALL
 ALSO INCLUDE A 10 SECOND PERIOD AT A
 LOAD EQUAL TO 1.5 TIMES THE DESIGN
 PRESSURE. DADE COUNTY & SBCCI REPORTS
 ARE ACCEPTED.
  
 7)1707.4.4.1 ANCHOR REQUIREMENTS:
 WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR
 ED IN ACCORDANCE WITH THE PUBLISHED
 MANUFACTURER'S RECOMMENDATIONS TO
 ACHIEVE THEDESIGN PRESSURE SPECIFIED.
 SUBSTITUTE ANCHORING SYSTEM USED FOR
 THE SUBSTRATE NOT SPECIFIED BY THE
 FENESTRATION MANUFACTURER SHALL PROVIDE
 EQUAL OR GREATER ANCHORING AS DEMONSTRA-
 TED BY ACCEPTED ENGINEERING PRACTICES.
  
 8) 1707.4.4.2. TAPERED BUCKS SHALL EX-
 TEND BEYOND THE INTERIOR FACE OF THE WIN
 DOW OR DOOR FRAME SUCH THAT FULL SUPPORT
 OF THE FRAME IS PROVIDED.
  
 9) 2313.4 GABLE ENDWALLS, SHALL BE CON-
 TINUOUS FROM THE UPPERMOST FLOOR TO THE
 CEILING DIAPHRAM OR TO THE ROOF DIAPHRAM
 2313.4.2.
  
 10) ASPHALT SHINGLES UNDERLAYMENT
 1507.3.8.1. FOR ROOF SLOPES FROM 2/12
 TO 4/12 UNDERLAYMENT SHALL BE A MINIMUM
 OF 2 LAYERS APPLIED WITH A 19" LAP.
  
 11) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 REAR ELEVATION NO FRAMING INFORMATION IS
 GIVEN ON THIS WALL. HEADER, TIE DOWNS
 ETC?
  
 12)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-07-08 Cont ID  
Sent By btrobaug Date 2003-07-08 Time 13:36 Rev Time 0.33
Received By btrobaug Date 2003-07-08 Time 13:08 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-12-03 Cont ID  
Sent By shernand Date 2003-07-07 Time 16:30 Rev Time 0.50
Received By btrobaug Date 2002-12-03 Time 16:51 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-07-07 Cont ID  
Sent By shernand Date 2003-07-07 Time 16:30 Rev Time 0.00
Received By shernand Date 2003-07-07 Time 16:30 Sent To E
Notes
2003-07-07 00:00:00BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-02-10 Cont ID  
Sent By dpalmer Date 2003-02-10 Time 10:58 Rev Time 0.00
Received By dpalmer Date 2003-02-10 Time 10:58 Sent To B
Notes
2003-02-10 00:00:00TO J W'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-02-06 Cont ID  
Sent By dpalmer Date 2003-02-06 Time 16:09 Rev Time 0.00
Received By dpalmer Date 2003-02-06 Time 16:09 Sent To M
Notes
2003-02-06 00:00:00TO MECH INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2002-12-03 Cont ID  
Sent By btrobaug Date 2002-12-03 Time 16:51 Rev Time 0.00
Received By btrobaug Date 2002-12-03 Time 16:50 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-22 Cont ID  
Sent By btrobaug Date 2002-11-22 Time 18:10 Rev Time 0.00
Received By btrobaug Date 2002-11-22 Time 18:10 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2003-07-09 Cont ID  
Sent By pkrauss Date 2003-07-09 Time 08:30 Rev Time 0.20
Received By pkrauss Date 2003-07-09 Time 08:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-02-11 Cont ID  
Sent By btrobaug Date 2003-07-08 Time 13:36 Rev Time 0.35
Received By pkrauss Date 2003-02-11 Time 08:32 Sent To  
Notes
2003-02-11 00:00:00PROVISO:
  
 PROVIDE EXISTING HVAC EQUIPMENT
 INFORMATION (MAKE, MODEL, BTUS OF AHU,
 & SEER OF CONDENSER).
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-02-08 Cont ID  
Sent By hmoser Date 2003-02-08 Time 09:57 Rev Time 0.50
Received By hmoser Date 2003-02-08 Time 09:57 Sent To E
Notes
2003-02-08 00:00:00PLAN DENIED
 NO ENERGY CALCULATIONS,MANUAL J,OR PLANS
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-02-08 Cont ID  
Sent By dpalmer Date 2003-02-06 Time 16:09 Rev Time 0.40
Received By hmoser Date 2002-12-09 Time 14:56 Sent To B
Notes
2002-12-09 00:00:00INSUFFICIENT INFORMATION FOR REVIEW.
  
 INDICATE MAKE, MODEL, BTU'S OF EXISTING
 AHU & MAKE MODEL & SEER OF HE CONDENSER
 UNIT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-07-12 Cont ID  
Sent By kstevens Date 2003-07-12 Time 08:18 Rev Time 0.25
Received By kstevens Date 2003-07-12 Time 08:18 Sent To B
Notes
2003-07-12 00:00:00REVISION OK - REDUCED SHOWER SIZE AND
 DELETED SEAT IN SHOWER

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-12-07 Cont ID  
Sent By btrobaug Date 2002-12-03 Time 16:51 Rev Time 0.25
Received By kstevens Date 2002-12-07 Time 06:00 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-12-03 Cont ID  
Sent By btrobaug Date 2002-11-22 Time 18:10 Rev Time 0.25
Received By sgraham Date   Time   Sent To B
Notes
***NONE***