Plan Review Details - Permit 02111490
Plan Review Stops For Permit 02111490
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-05-30 Cont ID  
Sent By csiegber Date 2003-08-27 Time 13:58 Rev Time 0.00
Received By alange Date 2003-07-23 Time 09:48 Sent To  
Notes
2003-07-23 00:00:00TO COMM BD #19ALANGE
2003-05-30 00:00:00REVISIONS DATED 5/6/03 A1.1 AND A1.2

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-02-28 Cont ID  
Sent By sthyng Date 2003-04-28 Time 12:35 Rev Time 0.00
Received By hpiskura Date 2003-02-27 Time 12:41 Sent To  
Notes
2003-02-28 00:00:00IMPACT FEES DUE COUNTY

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-02-14 Cont ID  
Sent By hpiskura Date 2003-02-05 Time 14:38 Rev Time 0.00
Received By hpiskura Date 2003-02-05 Time 10:06 Sent To  
Notes
2003-02-05 00:00:00SAME AS 1/16/03 CHECKLIST, AN ADDITIONAL
 COPY IS ATTACHED FOR YOUR USE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-02-14 Cont ID  
Sent By hpiskura Date 2003-01-16 Time 08:26 Rev Time 0.00
Received By hpiskura Date 2003-01-14 Time 15:11 Sent To ENG
Notes
2003-01-16 00:00:00THE PRINCIPAL USE OF THIS BUILDING IS IN
 OCCUPANCY GROUP E AS FOUND IN FBC 313.1
  
 THE CORRIDOR SHOWN AS #138 ON SHEET
 A1.1 IS REQUIRED BY FBC TABLE 704.2.4,
 NOTE 4 TO BE CONSTRUCTED TO RESIST THE
 PASSAGE OF SMOKE.THE PARTITION TYPE
 SHOWN AS A3 ON SHEET A5.4 DOES NOT
 COMPLY.PLEASE REVISE AS NECESSARY.
  
 FBC TABLE 1004 REQUIRES A MININMUM 72"
 WIDE CORRIDOR FOR GROUP E OCCUPANCIES.
 CORRIDOR #138 DOES NOT COMPLY.
  
 THE PLANS AND SPECIFICATIONS DO NOT
 DECLARE THE METHOD OF HURRICANE MISSILE
 IMPACT RESISTANCE IN ACCORDANCE WITH
 FBC 1606.1.4.
  
 IF TEST AND OR NOTICE OF ACCEPTANCE
 REPORTS FOR THE EXTERIOR DOORS, WINDOWS
 AND ROOF COVERINGS ARENOT INCLUDED
 WITH THIS PERMIT APPLICATION, A
 SEPARATE PERMIT AND ADDITIONAL FEES
 WILL BE REQUIRED.
  
 BEFORE A PERMIT TO CONSTRUCT MAY BE
 ISSUED IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, THE PERMIT PLANS STAMPED
 BY THAT OFFICE AND A COPY OF THE PAID
 RECEIPT ATTACHED TO THE PERMIT
 APPLICATION.CALL 561-233-5025 FOR
 MORE INFORMATION.

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2003-10-15 Cont ID  
Sent By dpalmer Date 2003-10-15 Time 08:57 Rev Time 0.33
Received By dpalmer Date 2003-10-15 Time 08:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2003-08-04 Cont ID  
Sent By csiegber Date 2003-10-06 Time 12:21 Rev Time 0.75
Received By dpalmer Date 2003-08-04 Time 15:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-05-29 Cont ID  
Sent By btrobaug Date 2003-05-29 Time 10:26 Rev Time 0.75
Received By btrobaug Date 2003-05-29 Time 09:32 Sent To  
Notes
2003-05-29 00:00:00PROVISO
 ~~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE NOTE THAT THE ADDED RECEPTACLES
 WERE NOT ADDED TO THE TOTAL IN THE LOAD
 CALC'S PER 220-3(B)(9).ALTHOUGH THIS IS
 A SMALL AMPERAGE AMOUNT,PLEASE
 KEEP ALL CHANGES CURRENT.PLEASE MAKE
 THIS CORRECTION ON THE NEXT REVISION.
  
 ALSO THE SIGN LIGHTING CIRCUIT MUST BE
 CHANGED TO COMPLY WITH 600-5(B)(3),1200
 VA.
  
 PLEASE NOTE THAT THE PROVISO FROM THE
 LAST REVIEW WAS NOT ADDRESSED.INCLUDE
 THOSE REVISIONS WITH THE NEXT SUBMITTAL.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 5691/805-6718

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-02-27 Cont ID  
Sent By dpalmer Date 2003-02-27 Time 06:36 Rev Time 0.75
Received By dpalmer Date 2003-02-27 Time 06:36 Sent To  
Notes
2003-02-27 00:00:00*************** NOTES REDLINED ******
  
 REVISE WITH ANY OTHER CHANGES BEFORE
 ROUGH ELECTRICAL INSPECTION IS CALLED IN
  
  
 1)NOTE: PLEASE SEE OCP SHOWN FOR PANEL
 "K". SHOWS 200A FUSE ON # 1/0`S,
 PLEASE CORRELATE PER 240-3,310-16
  
 2)NOTE: PLEASE SEE RISER DIAGRAM, SHOWS
 AN EQUIPMENT GROUND BETWEEN METER AND
 MAIN DISC'S. EQUIPMENT GROUNDING CONDUCT
 -OR IS ONLY INSTALLED AFTER FIRST MEANS
 OF DISC. 250-24
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW BEFORE ROUGH. IF THERE ARE ANY
 QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-02-13 Cont ID  
Sent By dpalmer Date 2003-02-13 Time 14:15 Rev Time 1.00
Received By dpalmer Date 2003-02-13 Time 14:15 Sent To  
Notes
2003-02-13 00:00:00*************** UNSAT *************
  
 PLEASE SEE NOTES FROM FIRST REVIEW?
 PLEASE NOTE, SAME SHEET E-2 WAS SUBMITT-
 -ED BACK FOR REVIEW.??
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-12-04 Cont ID  
Sent By hpiskura Date 2003-01-16 Time 08:49 Rev Time 1.50
Received By dpalmer Date 2002-12-04 Time 07:32 Sent To  
Notes
2002-12-04 00:00:00************** UNSAT ***************
  
 1)NOTE: PLEASE NOTE, CIRCUITING ON
 PLANS AND PANELS NEED TO CORRELATE.
 PLEASE NOTE THERE ARE MANY CIRCUITS ON
 PLANS THAT REPEAT. PLEASE NOTE, THERE
 ARE ALSO MISSING CIRCUIT(S).
  
 2)NOTE: PLEASE NOTE, LOADS ON CIRCUITS
 NEED TO BE VERIFIED. SOME DO NOT SEEM TO
 MATCH UP W/ # OF RECEPTS @ 180VA PER
 RECEPT.220-13.
  
 3)NOTE: PLEASE PROVIDE NOTE ON PLANS
 FOR HOOD SHUT DOWN PER NFPA-96 7-3.1.3.1
  
 4)NOTE: PLEASE CLARIFY TYPE OF FIXTURES
 TO BE USED IN HOODS ON FIXTURE SCHEDULE
 PER 410-4 AND NFPA-96 7-3
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW.IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 4 Status P Date 2003-03-06 Cont ID  
Sent By mamini Date 2003-03-06 Time 10:31 Rev Time 1.00
Received By mamini Date 2003-03-06 Time 10:31 Sent To  
Notes
2003-03-06 00:00:00PASSED:
 1. SEE PERMIT # 03030316 FOR UNDERGROUND
 UTILITIES AND SITE WORKS.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 3 Status F Date 2003-02-21 Cont ID  
Sent By mamini Date 2003-02-21 Time 13:32 Rev Time 1.00
Received By mamini Date 2003-02-21 Time 13:32 Sent To  
Notes
2003-02-21 00:00:00FAILED :
 1. PLEASE NOTE THAT A SEPARATE PERMIT
 APPLICATION AND FEES FOR UNDERGROUND
 UTILITIES AND SITE WORKS WILL BE
 REQUIRED.
 2. DRAINAGE CALCULATIONS SHOWS INVERT
 ELEVATION FOR V- NOTCH AT 17.71, DETAIL
 ON SHEET C-1 OF 3 SHOWS 18.21, PLEASE
 VERIFY.
 3. SIDEWALK ALONG THE PROPERTY ON
 SOUTHERN BLVD. MUST BE RESTORED AND MUST
 BE ACCESSIBLE, CURB CUT RAMPS MUST BE
 INSTALLED AT PROPOSED ENTRANCES.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2003-01-28 Cont ID  
Sent By hpiskura Date 2003-02-14 Time 15:41 Rev Time 1.00
Received By mamini Date 2003-01-28 Time 14:19 Sent To  
Notes
2003-01-28 00:00:00FAILED:
 1. IN ADDITION TO PREVIOUS REVIEW
 COMMENTS DATED 01/16/03 (SEE ATTACHED)
 ITEMS BELOW MUST BE ADDRESSED,
 1. PLEASE DISRGARD COMMENT NO. 6 OF THE
 PREVIOUS REVIEW.
 2. DRAINAGE CALCULATIONS SHOWS INVERT
 ELEVATION FOR V-NOTCH AT 17.71, DETAIL
 ON SHEET C-1 OF 3 SHOWS 18.21 PLEASE
 VERIFY.
 3. SIDEWALK ALONG THE PROPERTY ON
 SOUTHERN BLVD. MUST BE RESTORED AND MUST
 BE ACCESSIBLE, CURB CUT RAMPS MUST BE
 INSTALLED AT PROPOSED ENTRANCES.
 4. PLEASE NOTE THAT A SEPARATE PERMIT
 FROM FDOT FOR WORK WHITEN SOUTHERN BLVD.
 ROW WILL BE REQUIRED.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2003-01-16 Cont ID  
Sent By hpiskura Date 2003-01-16 Time 08:49 Rev Time 2.00
Received By mamini Date 2003-01-16 Time 11:00 Sent To  
Notes
2003-01-16 00:00:00FAILED :
 1. PLEASE NOTE THAT A SEPARATE PERMIT
 APPLICATION AND FEES FOR UNDERGROUND
 UTILITIES AND CIVIL SITE WORK WILL BE
 REQUIRED.
 2. ALL THE NEW CONNECTIONS TO CITY
 SERVICES, BACKFLOW PREVENTERS AND
 LOCATIONS MUST BE APPROVED BY PUBLIC
 UTILITIES ENGINEERING SERVICES, PLEASE
 SUBMIT PLANS AND CALCULATIONS FOR STORM-
 WATER, SEWER AND DOMESTIC WATER.
 MR. MANNY GONZALEZ 659-8040 EXT. 2306
 3. PLEASE CONTACT MR. RODNEY COMPO
 FOR INSTALLATION, SIZE, LOCATION OF THE
 PROPOSED GREASE/WATER. 837-4051 EXT.
 4074
 4. DRIVEWAY APPROACHES AS SHOWN DO NOT
 MATCH THE SANDARD SHOWN ON SHEET C-3 OF
 3, DRIVEWAY APPROACHES MUST AT MIN. BE
 PER CITY STANDARD.
 5. INDEXES MUST BE INCLUDED ON SHEET C-3
 OF 3, IF THEY ARE REFERED TO. SEE SHEET
 C-2 OF 3.
 6. IF MANHOLE #3 IS A CONTROL STRUCTURE
 THEN DETAILS MUST BE SHOWN.
 7. SHEET C-2 OF 3 REFERS TO PER CITY OF
 WPB STANDARD G-5 FOR CONNECTION OF SEWER
 LATERAL, PLEASE VERIFY.
 8. PLEASE SHOW ELEVATIONS ON EXFILTRA-
 TION TRANCH DETAILS.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2003-08-11 Cont ID  
Sent By nmccray Date 2003-08-11 Time 11:24 Rev Time 0.00
Received By nmccray Date 2003-08-11 Time 11:24 Sent To  
Notes
2003-08-11 00:00:00REVISIONS DATED 7-22-03

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2003-06-26 Cont ID  
Sent By nmccray Date 2003-06-26 Time 11:09 Rev Time 0.00
Received By nmccray Date 2003-06-26 Time 11:09 Sent To  
Notes
2003-06-26 00:00:00REVISION 5-27-03 FP-1

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2003-03-13 Cont ID  
Sent By mcarsill Date 2003-03-13 Time 15:53 Rev Time 0.00
Received By mcarsill Date 2003-03-13 Time 15:53 Sent To  
Notes
2003-03-13 00:00:00PASSED WITH PROVISO: CORRIDOR 138 SHALL
 BE AT LEAST 72 INCHES WIDE. PLEASE
 CORRECT DISCREPANCY.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-02-19 Cont ID  
Sent By nmccray Date 2003-02-19 Time 10:51 Rev Time 0.00
Received By nmccray Date 2003-02-19 Time 10:51 Sent To  
Notes
2003-02-19 00:00:00PROVISO
 1) SEPARATE PLANS AND PERMITS REQUIRED
 FOR THE FIRE SPRINKLER AND FIRE ALARM
 SYSTEMS.
  
 2) SEPARATE PLANS AND PERMITS REQUIRED
 FOR HOOD AND SUPPRESSION SYSTEMS.
  
 NATE MCCRAY, CAPTAIN
 659-8096, EXT 8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-12-18 Cont ID  
Sent By mcarsill Date 2002-12-18 Time 09:07 Rev Time 0.00
Received By mcarsill Date 2002-12-18 Time 09:07 Sent To  
Notes
2002-12-18 00:00:001) PLEASE PROVIDE A COMPLETE LIFE SAFETY
 PLAN DETAILING OCCUPANT LOADS, TRAVEL
 DISTANCES,ETC.
  
 2) THE FIRE ALARM CONTROL PANEL APPEARS
 TO BE LOCATED BEHIND AN EXIT DOOR.
  
 3) SEPARATE PLANS AND PERMITS REQUIRED
 FOR ANY HOOD,DUCT,AND EXTINGUISHING
 SYSTEMS.
  
 4) SEPARATE PLANS AND PERMITS REQUIRED
 FOR THE FIRE SPRINKLER AND FIRE
 ALARM SYSTEMS.
  
 5) PANIC HARDWARE REQUIRED ON ALL EXIT
 DOORS SUBJECT TO OCCUPANCIES OF 100
 OR MORE PERSONS.
  
 6) PLEASE INDICATE INTERIOR FINISH
 CLASSIFICATION INFORMATION FOR WALLS
 AND CEILINGS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2003-10-06 Cont ID  
Sent By csiegber Date 2003-10-06 Time 12:20 Rev Time 0.00
Received By csiegber Date 2003-10-06 Time 12:20 Sent To E
Notes
2003-10-06 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2003-09-19 Cont ID  
Sent By csiegber Date 2003-09-19 Time 10:27 Rev Time 0.00
Received By csiegber Date 2003-09-19 Time 10:27 Sent To M
Notes
2003-09-19 00:00:00REV SMOKE DAMPERS ADDED

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2003-08-27 Cont ID  
Sent By csiegber Date 2003-08-27 Time 13:58 Rev Time 0.00
Received By csiegber Date 2003-08-27 Time 13:58 Sent To B
Notes
2003-08-27 00:00:00MISC BOX

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2003-07-24 Cont ID  
Sent By alange Date 2003-07-24 Time 11:39 Rev Time 0.00
Received By alange Date 2003-07-23 Time 09:56 Sent To  
Notes
2003-07-23 00:00:00IN COMM BOX #19,2 REV IN BOX

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2003-07-14 Cont ID  
Sent By shernand Date 2003-07-14 Time 09:58 Rev Time 0.00
Received By shernand Date 2003-07-14 Time 09:58 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2003-07-10 Cont ID  
Sent By shernand Date 2003-07-10 Time 11:59 Rev Time 0.00
Received By shernand Date 2003-07-10 Time 11:59 Sent To B
Notes
2003-07-10 00:00:00HP, PRODUCT APPROVALS.

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2003-06-19 Cont ID  
Sent By shernand Date 2003-06-19 Time 15:59 Rev Time 0.00
Received By shernand Date 2003-06-19 Time 15:59 Sent To B
Notes
2003-06-19 00:00:00HP DESK

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2003-05-27 Cont ID  
Sent By shernand Date 2003-05-27 Time 16:05 Rev Time 0.00
Received By shernand Date 2003-05-27 Time 16:05 Sent To  
Notes
2003-05-27 00:00:00COMM BOARD #4

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-04-28 Cont ID  
Sent By sthyng Date 2003-04-28 Time 12:35 Rev Time 0.00
Received By sthyng Date 2003-04-28 Time 12:35 Sent To B
Notes
2003-04-28 00:00:00TO HP DESK
  
 TIE IN SURVEY

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-03-24 Cont ID  
Sent By sthyng Date 2003-03-24 Time 09:07 Rev Time 0.00
Received By sthyng Date 2003-03-24 Time 09:07 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-02-28 Cont ID  
Sent By btrobaug Date 2003-02-28 Time 15:22 Rev Time 0.00
Received By btrobaug Date 2003-02-28 Time 15:22 Sent To B
Notes
2003-02-28 00:00:00TO HHP./WRT

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-02-20 Cont ID  
Sent By dpalmer Date 2003-02-20 Time 10:43 Rev Time 0.00
Received By dpalmer Date 2003-02-20 Time 10:43 Sent To  
Notes
2003-02-20 00:00:00TO COMM BOARD #56
 B,P,E,F

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-17 Cont ID  
Sent By btrobaug Date 2003-01-17 Time 09:55 Rev Time 0.00
Received By btrobaug Date 2003-01-16 Time 09:54 Sent To  
Notes
2003-01-17 00:00:00UP FRONT,DOWN BELOW WITH CONTRACTORS
 NAME ON PLANS,CALLED./WRT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-21 Cont ID  
Sent By sgraham Date 2003-01-16 Time 12:05 Rev Time 0.00
Received By btrobaug Date 2002-11-21 Time 18:44 Sent To  
Notes
2002-11-21 00:00:00TO COMM BOARD # 48./WRT.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2003-09-25 Cont ID  
Sent By pkrauss Date 2003-09-25 Time 12:44 Rev Time 0.35
Received By pkrauss Date 2003-09-25 Time 12:43 Sent To  
Notes
2003-09-25 00:00:00PROVISO:
 PROVIDE MANUFACTURERS INSTALLATION
 INSTRUCTIONS FOR THE SMOKE DAMPERS ON
 JOBSITE FOR INSPECTION.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-06-06 Cont ID  
Sent By csiegber Date 2003-09-19 Time 10:27 Rev Time 0.45
Received By pkrauss Date 2003-06-06 Time 07:53 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-02-13 Cont ID  
Sent By pkrauss Date 2003-02-13 Time 11:10 Rev Time 0.45
Received By pkrauss Date 2003-02-13 Time 10:41 Sent To  
Notes
2003-02-13 00:00:00PROVISO:
  
 ACCESS FOR RTU 5 & 6 SHALL NOT REQUIRE
 CLIMBING OVER OBSTRUCTIONS GREATER THAN
 30" (2001 FBC(M) 306.5).
  
 ADDITIONAL PERMITS REQUIRED FOR HOOD,
 FIRE SUPRESSION AND WALK-IN COOLERS.
 PLEASE PROVIDE PLANS & MANUFACTURERS
 SUBMITTAL DATA WITH PERMIT APPLICATION.
 PLAN SHEET M-1 NOTE #13 INDICATES GREASE
 DUCT TO BE WRAPPED WITH FIRE WRAP.
 PROVIDE SUBMITTAL FOR THE FIRE WRAP
 WITH HOOD PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-12-23 Cont ID  
Sent By pkrauss Date 2002-12-23 Time 07:13 Rev Time 1.30
Received By pkrauss Date 2002-12-23 Time 06:36 Sent To  
Notes
2002-12-23 00:00:00HVAC NOTES:
 PLAN SHEET M-1 PRESCHOOL RM 129, PLAN
 INDICATES A FIRE DAMPER AT OVER THE DOOR
 TO THIS ROOM.ARCHITECTURAL PLAN DOES
 NOT INDICATE THIS AS A RATED WALL.
 PLEASE CLARIFY.
  
 AS PER 2001 FBC(M) 306.5 EQUIPMENT
 LOCATED ON ROOFS OR ELEVATED STRUCTURES,
 ACCESS TO RTU'S #1, 2, 5 & 6 SHALL NOT
 REQUIRE CLIMBING OVER OBSTRUCTIONS
 GREATER THAN 30".
  
 PROVIDE INFORMATION ON THE ROOF RACK FOR
 THE CONDENSING UNITS FOR THE WALK-IN
 COOLER/FREEZER.SHOW COMPLIANCE WITH
 2001 FBC TABLE 1511.7 FOR THE STAND
 CLEARANCE BETWEEN FINISHED ROOF & THE
 BOTTOM OF THE SUPPORT RAIL.
  
 HOOD PLAN REVIEW:
 ADDITIONAL PERMIT REQUIRED FOR HOOD.
 PLAN SHEET M-1 DRAWING KEYNOTE #13,
 INDICATES THE GREASE DUCT IN A 2 HR
 SHAFT.PLEASE PROVIDE CROSS-SECTION
 DETAIL OF UL RATED ASSEMBLY.INSPECTION
 OF WELDS REQUIRED PRIOR TO COVERING
 DUCTWORK.
  
 EXHAUST TERMINATION SHALL BE LOCATED NOT
 LESS THAN 10 FT HORIZONTALLY FROM PARTS
 OF THE SAME OR CONTIGUOUS BUILDINGS,
 ADJACENT PROPERTY LINES & AIR INTAKE
 OPENINGS.2001 FBC(M) 506.3.14.3.
  
 WALK-IN COOLER & FREEZER:
 PROVIDE MANUFACTURER SUBMITTAL DATA &
 INSTALLATION INSTRUCTIONS WITH PERMIT
 APPLICATION.
  
 ADDITIONAL PERMIT REQUIRED FOR FIRE
 SUPRESSION.PLEASE PROVIDE PLANS WITH
 PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 6 Status P Date 2003-08-06 Cont ID  
Sent By kstevens Date 2003-08-06 Time 18:46 Rev Time 1.00
Received By kstevens Date 2003-08-06 Time 18:46 Sent To  
Notes
2003-08-06 00:00:00REVISIONS OK - MOVED ROOF DRAINS ADDED
 PIPING - ADDED SECONDARY ROOF DRAINS AND
 ADDED PIPING - MOVED SINKS AND PIPING
 ADDED BALANCING VALVES - DELETED A ROOF
 DRAIN - MOVED A WATER HEATER LOCATION

Review Stop P PLUMBING
Rev No 5 Status F Date 2003-06-14 Cont ID  
Sent By shernand Date 2003-07-14 Time 09:58 Rev Time 0.50
Received By kstevens Date 2003-06-14 Time 17:19 Sent To  
Notes
2003-06-14 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 ADMIN CODE, CHAPTER
 1, & AMENDMENTS.
  
 1) SHT P-4 HOT WATER BALANCING VALVES
 SHOWN ADDED ON SHT P-1 KEYNOTES #22 ARE
 NOT SHOWN ON WATER RISER ISOMETRIC.
 PLEASE ADD AND RESUBMIT.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 4 Status P Date 2003-03-26 Cont ID  
Sent By kstevens Date 2003-03-26 Time 16:12 Rev Time 2.25
Received By kstevens Date 2003-03-26 Time 16:10 Sent To  
Notes
2003-03-26 00:00:00PASSED/PROVISO
  
 SEPARATE IRRIGATION PERMIT REQUIRED
  
 SEPARATE GAS PERMIT REQUIRED - FOLLOWING
 INFORMATION REQUIRED AT TIME OF APPLIC-
 ATION - TYPE OF GAS - DELIVERY PRESSURE-
 MANUFACTURE SHEETS FOR GAS RANGE WITH
 BTU'S SHOWN AND LISTED AGENCY.

Review Stop P PLUMBING
Rev No 3 Status F Date 2003-03-20 Cont ID  
Sent By sthyng Date 2003-03-24 Time 09:07 Rev Time 3.00
Received By kstevens Date 2003-03-19 Time 16:52 Sent To  
Notes
2003-03-20 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
 FBC-2001 FUEL GAS
  
 1) RODNEY COMPO, ENVIRONMENTAL COMPLI-
 ANCE HAS NOT BEEN CONTACTED AS OF YET.
 I CALLED HIM AND THE CONTRACTOR AND THEY
 WILL INFORM ME AS TO THE SIZE OF GREASE
 TRAP THAT WILL BE REQUIRED.
 2) ROOF DRAIN/SCUPPER FOR 1803 SQ FT -
 1985 SQ FT COMBINATION IS NOT SUFFICIENT
 FOR THIS AREA. MINIMUM OF 113 SQ IN
 OPENING IS REQUIRED FOR THIS ROOF DRAIN/
 SCUPPER COMBINATION OPENING.
 3) RECOMMENDED LAV HEIGHT FOR CHILDREN
 AGES 2 THRU 5 IS 20" TO 24". SEE ATTACH-
 ED SHEET.
 4) GAS PERMIT WILL BE SEPARATE. INFOR-
 MATION REQUIRED AT TIME OF APPLICATION,
 TYPE OF GAS, - DELIVERY PRESSURE, - AND
 MANUFACTURE SHEETS FOR GAS RANGE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-02-04 Cont ID  
Sent By kstevens Date 2003-02-04 Time 16:10 Rev Time 1.50
Received By kstevens Date 2003-02-04 Time 16:05 Sent To  
Notes
2003-02-04 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 11
  
 1) FROM PREVIOUS REVIEW: ROUTE PLANS TO
 PALM BEACH COUNTY HEALTH UNIT, DIVISION
 OF ENVIRONMENTAL HEALTH, 901 EVERNIA ST.
 WPB. PLANS SHALL BE STAMPED PRIOR TO RE-
 SUBMITTING TO CITY FOR REVIEW.
 2) FROM PREVIOUS REVIEW: CONTACT RODNEY
 COMPO, ENVIRONMENTAL COMPLIANCE, FOR
 GREASE TRAP REQUIREMENTS. WASTE ORD
 #2938-96. @ (561) 837-4074.
 3) FROM PREVIOUS REVIEW: SHT A1.1 ROOM
 104, DOOR SHALL NOT OPEN INTO THE CLEAR
 FLOOR SPACE OF LAV.
 4) FROM PREVIOUS REVIEW: PLEASE INDICATE
 CLEAR FLOOR SPACE FOR ALL HDCP FIXTURES.
 SHOW 5' TURNING SPACE FOR EACH TOILET
 ROOM. SHT A1.1
 5) FROM PREVIOUS REVIEW: SHT A1.3 PLEASE
 PROVIDE CALCULATIONS FOR PRIMARY AND
 SECONDARY ROF DRAINS PER SECTIONS 1106,
 & 1107. INCLUDE 1/2 AREA OF ALL VERTICAL
 WALLS INCLUDING PARAPET WALLS. ALSO SHOW
 LOCATIONS FOR ALL SECONDARY ROOF DRAINS.
 6) FROM PREVIOUS REVIEW: SHT A5.1,
 SCUPPER DETAIL, PLESE INDICATE TOTAL
 AREA OF SCUPPER OPENING. THE ONLY DIMEN-
 SION IS 4" HIGH.
 7) FROM PREVIOUS REVIEW: SHT A6.2 ROOM
 115 DETAIL. SINK IN LOUNGE SHALL COMPLY
 WITH 11-4.24 AND ALL SUBSECTIONS. PLEASE
 SHOW ON DETAIL. (DETAIL #5 ONLY SHOWS
 DETAIL FOR 11-4.24.2)
 8) FROM PREVIOUS REVIEW: SHT FS-3 ALL
 INDIRECT WASTE SHALL DRAIN INTO A FLOOR
 SINK. SECTION 802.3 (SHT P-3 CHANGED BUT
 NOT FS-3)
 9) FROM PREVIOUS REVIEW: WILL THE FIX-
 TURES FOR CHILDREN BE LOWERED PER ADA
 GUIDLINES FOR BUILDINGS & FACILITIES;
 BUILDING ELEMENTS DESIGNED FOR CHILDRENS
 USE? (NO REPLY NOTED)
 10) FROM PREVIOUS REVIEW: FOR GAS REVIEW
 SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE FBC-
 2001 FUEL GAS CODE SEC 402.2.
 *********WHEN RESUBMITTING PLANS********
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-12-26 Cont ID  
Sent By kstevens Date 2002-12-26 Time 09:10 Rev Time 7.00
Received By kstevens Date 2002-12-26 Time 08:52 Sent To  
Notes
2002-12-26 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 11
  
 1) PLEASE ROUTE PLANS TO PALM BEACH
 COUNTY HEALTH UNIT, DIVISION OF ENVIRON-
 MENTAL HEALTH, 901 EVERNIA ST W.P.B
 (561) 355-3018.SECTION 101.4.7
 2) CONTACT RODNEY COMPO, ENVIRONMENTAL
 COMPLIANCE, FOR GREASE TRAP REQUIREMENTS
 WASTE ORD. #2938-96 (561) 837-4074
 3) SHT D-1, NOTE G - DEMO PERMIT REQUIR-
 ED FOR PLUMBING.
 4) SHT A1.1 ROOM 104, DOOR SHALL NOT
 OPEN INTO THE CLEAR FLOOR SPACE OF LAV.
 5) PLEASE INDICATE CLEAR FLOOR SPACE FOR
 ALL HDCP FIXTURES, AND SHOW 5' TURNING
 RADIUS FOR EACH TOILET ROOM.
 6) SHT A1.3, PLEASE PROVIDE CALCULATIONS
 FOR THE PRIMARY & SECONDARY ROOF DRAINS,
 PER SECTIONS 1106 & 1107. INCLUDE 1/2
 AREA OF ALL VERTICAL WALLS. ALSO SHOW
 LOCATION OF ALL SECONDARY ROOF DRAINS.
 7) SHT A5.1, SCUPPER DETAIL, PLEASE IN-
 DICATE TOTAL AREA OF SCUPPER OPENING.
 THE ONLY DIMENSION SHOWN IS 4" HIGH.
 8) SHT A6.2, ROOM 115 DETAIL, SINK IN
 LOUNGE SHALL COMPLY WITH 4.24 AND ALL
 SUBSECTIONS. PLEASE SHOW ON DETAIL.
 9) SHTS FS-3 & P-3 ALL INDIRECT WASTE
 SHALL DRAIN INTO A FLOOR SINK. SECTION
 802.3. FUNNEL FLOOR DRAIN ON GREASE
 SYSTEM NOT APPROVED.
 10) SHT P-2, GREASE TRAP DETAIL, PLEASE
 SEE ATTACHED SHEET FOR APPROVED CITY OF
 WEST PALM BEACH STANDARD GREASE TRAP DE-
 TAIL.
 11) SHT P-3, STORM DRAIN ISOMETRIC, SIZE
 OF STORM DRAINAGE PIPING REQUIRED FOR
 BLDG. DRAIN.
 12) SHT P-4, WATER ISOMETRIC, AIR CHAMB-
 ERS ARE NOT APPROVED, PLEASE DELETE FROM
 ISO. ALL WATER HAMMER ARRESTORS REQUIRED
 BY 604.9 SHALL BE LOCATED NEAR THE FIX-
 TURES IN AN "EFFECTIVE RANGE" NOT IN
 CEILING AT TOP OF DROP.
 13) WILL THE FIXTURES FOR CHILDREN BE
 LOWERED PER ADA GUIDELINES FOR BUILDINGS
 & FACILITIES; BUILDING ELEMENTS DESIGNED
 FOR CHILDREN'S USE?
 14) FOLLOWING INFORMATION REQUIRED FOR
 APPLICATION FOR GAS (SEPARATE) PERMIT.
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2001
 FUEL GAS CODE.
 B. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE BEING USED.
 SPECIFICATION BOOK SHOWS "A" COPPER
 TUBING & "B" SCHED. 40 STEEL PIPE.
 PLEASE CLAIRFY.
 C. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2001 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES (A)(3).
 D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2001 FUEL GAS CODE SEC 402.2
 E. EMERGENCY HOOD SHUT DOWN SHUT OFF
 VALVE TO BE BELOW CEILING. MANUAL SHUT
 OFF VALVE TO BE UPSTREAM. UNION TO BE
 DOWN STREAM OF MANUAL VALVE. - UNION NOT
 SHOWN ON PLANS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2003-01-16 Cont ID  
Sent By sgraham Date 2003-01-16 Time 12:05 Rev Time 0.00
Received By sgraham Date   Time   Sent To I
Notes
***NONE***