| Plan Review Stops For Permit 02111490 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-05-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-27 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-23 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2003-07-23 00:00:00 | TO COMM BD #19ALANGE | | 2003-05-30 00:00:00 | REVISIONS DATED 5/6/03 A1.1 AND A1.2 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-02-28 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-04-28 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-02-27 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2003-02-28 00:00:00 | IMPACT FEES DUE COUNTY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-02-14 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-02-05 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-02-05 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2003-02-05 00:00:00 | SAME AS 1/16/03 CHECKLIST, AN ADDITIONAL | | | COPY IS ATTACHED FOR YOUR USE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-02-14 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-01-16 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-01-14 |
Time |
15:11 |
Sent To |
ENG |
|
| Notes |
| 2003-01-16 00:00:00 | THE PRINCIPAL USE OF THIS BUILDING IS IN | | | OCCUPANCY GROUP E AS FOUND IN FBC 313.1 | | | | | | THE CORRIDOR SHOWN AS #138 ON SHEET | | | A1.1 IS REQUIRED BY FBC TABLE 704.2.4, | | | NOTE 4 TO BE CONSTRUCTED TO RESIST THE | | | PASSAGE OF SMOKE.THE PARTITION TYPE | | | SHOWN AS A3 ON SHEET A5.4 DOES NOT | | | COMPLY.PLEASE REVISE AS NECESSARY. | | | | | | FBC TABLE 1004 REQUIRES A MININMUM 72" | | | WIDE CORRIDOR FOR GROUP E OCCUPANCIES. | | | CORRIDOR #138 DOES NOT COMPLY. | | | | | | THE PLANS AND SPECIFICATIONS DO NOT | | | DECLARE THE METHOD OF HURRICANE MISSILE | | | IMPACT RESISTANCE IN ACCORDANCE WITH | | | FBC 1606.1.4. | | | | | | IF TEST AND OR NOTICE OF ACCEPTANCE | | | REPORTS FOR THE EXTERIOR DOORS, WINDOWS | | | AND ROOF COVERINGS ARENOT INCLUDED | | | WITH THIS PERMIT APPLICATION, A | | | SEPARATE PERMIT AND ADDITIONAL FEES | | | WILL BE REQUIRED. | | | | | | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, THE PERMIT PLANS STAMPED | | | BY THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION.CALL 561-233-5025 FOR | | | MORE INFORMATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2003-10-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-15 |
Time |
08:57 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-10-15 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-06 |
Time |
12:21 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-08-04 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-05-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-05-29 |
Time |
10:26 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2003-05-29 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2003-05-29 00:00:00 | PROVISO | | | ~~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE NOTE THAT THE ADDED RECEPTACLES | | | WERE NOT ADDED TO THE TOTAL IN THE LOAD | | | CALC'S PER 220-3(B)(9).ALTHOUGH THIS IS | | | A SMALL AMPERAGE AMOUNT,PLEASE | | | KEEP ALL CHANGES CURRENT.PLEASE MAKE | | | THIS CORRECTION ON THE NEXT REVISION. | | | | | | ALSO THE SIGN LIGHTING CIRCUIT MUST BE | | | CHANGED TO COMPLY WITH 600-5(B)(3),1200 | | | VA. | | | | | | PLEASE NOTE THAT THE PROVISO FROM THE | | | LAST REVIEW WAS NOT ADDRESSED.INCLUDE | | | THOSE REVISIONS WITH THE NEXT SUBMITTAL. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 5691/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-02-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-27 |
Time |
06:36 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-02-27 |
Time |
06:36 |
Sent To |
|
|
| Notes |
| 2003-02-27 00:00:00 | *************** NOTES REDLINED ****** | | | | | | REVISE WITH ANY OTHER CHANGES BEFORE | | | ROUGH ELECTRICAL INSPECTION IS CALLED IN | | | | | | | | | 1)NOTE: PLEASE SEE OCP SHOWN FOR PANEL | | | "K". SHOWS 200A FUSE ON # 1/0`S, | | | PLEASE CORRELATE PER 240-3,310-16 | | | | | | 2)NOTE: PLEASE SEE RISER DIAGRAM, SHOWS | | | AN EQUIPMENT GROUND BETWEEN METER AND | | | MAIN DISC'S. EQUIPMENT GROUNDING CONDUCT | | | -OR IS ONLY INSTALLED AFTER FIRST MEANS | | | OF DISC. 250-24 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW BEFORE ROUGH. IF THERE ARE ANY | | | QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-02-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-13 |
Time |
14:15 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-02-13 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2003-02-13 00:00:00 | *************** UNSAT ************* | | | | | | PLEASE SEE NOTES FROM FIRST REVIEW? | | | PLEASE NOTE, SAME SHEET E-2 WAS SUBMITT- | | | -ED BACK FOR REVIEW.?? | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-12-04 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-01-16 |
Time |
08:49 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2002-12-04 |
Time |
07:32 |
Sent To |
|
|
| Notes |
| 2002-12-04 00:00:00 | ************** UNSAT *************** | | | | | | 1)NOTE: PLEASE NOTE, CIRCUITING ON | | | PLANS AND PANELS NEED TO CORRELATE. | | | PLEASE NOTE THERE ARE MANY CIRCUITS ON | | | PLANS THAT REPEAT. PLEASE NOTE, THERE | | | ARE ALSO MISSING CIRCUIT(S). | | | | | | 2)NOTE: PLEASE NOTE, LOADS ON CIRCUITS | | | NEED TO BE VERIFIED. SOME DO NOT SEEM TO | | | MATCH UP W/ # OF RECEPTS @ 180VA PER | | | RECEPT.220-13. | | | | | | 3)NOTE: PLEASE PROVIDE NOTE ON PLANS | | | FOR HOOD SHUT DOWN PER NFPA-96 7-3.1.3.1 | | | | | | 4)NOTE: PLEASE CLARIFY TYPE OF FIXTURES | | | TO BE USED IN HOODS ON FIXTURE SCHEDULE | | | PER 410-4 AND NFPA-96 7-3 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW.IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2003-03-06 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-03-06 |
Time |
10:31 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-03-06 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2003-03-06 00:00:00 | PASSED: | | | 1. SEE PERMIT # 03030316 FOR UNDERGROUND | | | UTILITIES AND SITE WORKS. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2003-02-21 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-02-21 |
Time |
13:32 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-02-21 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2003-02-21 00:00:00 | FAILED : | | | 1. PLEASE NOTE THAT A SEPARATE PERMIT | | | APPLICATION AND FEES FOR UNDERGROUND | | | UTILITIES AND SITE WORKS WILL BE | | | REQUIRED. | | | 2. DRAINAGE CALCULATIONS SHOWS INVERT | | | ELEVATION FOR V- NOTCH AT 17.71, DETAIL | | | ON SHEET C-1 OF 3 SHOWS 18.21, PLEASE | | | VERIFY. | | | 3. SIDEWALK ALONG THE PROPERTY ON | | | SOUTHERN BLVD. MUST BE RESTORED AND MUST | | | BE ACCESSIBLE, CURB CUT RAMPS MUST BE | | | INSTALLED AT PROPOSED ENTRANCES. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2003-01-28 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-02-14 |
Time |
15:41 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-01-28 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2003-01-28 00:00:00 | FAILED: | | | 1. IN ADDITION TO PREVIOUS REVIEW | | | COMMENTS DATED 01/16/03 (SEE ATTACHED) | | | ITEMS BELOW MUST BE ADDRESSED, | | | 1. PLEASE DISRGARD COMMENT NO. 6 OF THE | | | PREVIOUS REVIEW. | | | 2. DRAINAGE CALCULATIONS SHOWS INVERT | | | ELEVATION FOR V-NOTCH AT 17.71, DETAIL | | | ON SHEET C-1 OF 3 SHOWS 18.21 PLEASE | | | VERIFY. | | | 3. SIDEWALK ALONG THE PROPERTY ON | | | SOUTHERN BLVD. MUST BE RESTORED AND MUST | | | BE ACCESSIBLE, CURB CUT RAMPS MUST BE | | | INSTALLED AT PROPOSED ENTRANCES. | | | 4. PLEASE NOTE THAT A SEPARATE PERMIT | | | FROM FDOT FOR WORK WHITEN SOUTHERN BLVD. | | | ROW WILL BE REQUIRED. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2003-01-16 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-01-16 |
Time |
08:49 |
Rev Time |
2.00 |
| Received By |
mamini |
Date |
2003-01-16 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2003-01-16 00:00:00 | FAILED : | | | 1. PLEASE NOTE THAT A SEPARATE PERMIT | | | APPLICATION AND FEES FOR UNDERGROUND | | | UTILITIES AND CIVIL SITE WORK WILL BE | | | REQUIRED. | | | 2. ALL THE NEW CONNECTIONS TO CITY | | | SERVICES, BACKFLOW PREVENTERS AND | | | LOCATIONS MUST BE APPROVED BY PUBLIC | | | UTILITIES ENGINEERING SERVICES, PLEASE | | | SUBMIT PLANS AND CALCULATIONS FOR STORM- | | | WATER, SEWER AND DOMESTIC WATER. | | | MR. MANNY GONZALEZ 659-8040 EXT. 2306 | | | 3. PLEASE CONTACT MR. RODNEY COMPO | | | FOR INSTALLATION, SIZE, LOCATION OF THE | | | PROPOSED GREASE/WATER. 837-4051 EXT. | | | 4074 | | | 4. DRIVEWAY APPROACHES AS SHOWN DO NOT | | | MATCH THE SANDARD SHOWN ON SHEET C-3 OF | | | 3, DRIVEWAY APPROACHES MUST AT MIN. BE | | | PER CITY STANDARD. | | | 5. INDEXES MUST BE INCLUDED ON SHEET C-3 | | | OF 3, IF THEY ARE REFERED TO. SEE SHEET | | | C-2 OF 3. | | | 6. IF MANHOLE #3 IS A CONTROL STRUCTURE | | | THEN DETAILS MUST BE SHOWN. | | | 7. SHEET C-2 OF 3 REFERS TO PER CITY OF | | | WPB STANDARD G-5 FOR CONNECTION OF SEWER | | | LATERAL, PLEASE VERIFY. | | | 8. PLEASE SHOW ELEVATIONS ON EXFILTRA- | | | TION TRANCH DETAILS. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2003-08-11 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-08-11 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-08-11 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2003-08-11 00:00:00 | REVISIONS DATED 7-22-03 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2003-06-26 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-06-26 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-06-26 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2003-06-26 00:00:00 | REVISION 5-27-03 FP-1 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-03-13 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-03-13 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-03-13 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2003-03-13 00:00:00 | PASSED WITH PROVISO: CORRIDOR 138 SHALL | | | BE AT LEAST 72 INCHES WIDE. PLEASE | | | CORRECT DISCREPANCY. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-02-19 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-02-19 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-02-19 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2003-02-19 00:00:00 | PROVISO | | | 1) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR THE FIRE SPRINKLER AND FIRE ALARM | | | SYSTEMS. | | | | | | 2) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR HOOD AND SUPPRESSION SYSTEMS. | | | | | | NATE MCCRAY, CAPTAIN | | | 659-8096, EXT 8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-12-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-12-18 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-12-18 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2002-12-18 00:00:00 | 1) PLEASE PROVIDE A COMPLETE LIFE SAFETY | | | PLAN DETAILING OCCUPANT LOADS, TRAVEL | | | DISTANCES,ETC. | | | | | | 2) THE FIRE ALARM CONTROL PANEL APPEARS | | | TO BE LOCATED BEHIND AN EXIT DOOR. | | | | | | 3) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR ANY HOOD,DUCT,AND EXTINGUISHING | | | SYSTEMS. | | | | | | 4) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR THE FIRE SPRINKLER AND FIRE | | | ALARM SYSTEMS. | | | | | | 5) PANIC HARDWARE REQUIRED ON ALL EXIT | | | DOORS SUBJECT TO OCCUPANCIES OF 100 | | | OR MORE PERSONS. | | | | | | 6) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATION INFORMATION FOR WALLS | | | AND CEILINGS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2003-10-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-06 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-06 |
Time |
12:20 |
Sent To |
E |
|
| Notes |
| 2003-10-06 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2003-09-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-19 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-19 |
Time |
10:27 |
Sent To |
M |
|
| Notes |
| 2003-09-19 00:00:00 | REV SMOKE DAMPERS ADDED |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2003-08-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-27 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-27 |
Time |
13:58 |
Sent To |
B |
|
| Notes |
| 2003-08-27 00:00:00 | MISC BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2003-07-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-24 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-23 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2003-07-23 00:00:00 | IN COMM BOX #19,2 REV IN BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2003-07-14 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-14 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-14 |
Time |
09:58 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2003-07-10 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-10 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-10 |
Time |
11:59 |
Sent To |
B |
|
| Notes |
| 2003-07-10 00:00:00 | HP, PRODUCT APPROVALS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-19 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-19 |
Time |
15:59 |
Sent To |
B |
|
| Notes |
| 2003-06-19 00:00:00 | HP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-05-27 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-27 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-27 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2003-05-27 00:00:00 | COMM BOARD #4 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-04-28 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-04-28 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-04-28 |
Time |
12:35 |
Sent To |
B |
|
| Notes |
| 2003-04-28 00:00:00 | TO HP DESK | | | | | | TIE IN SURVEY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-03-24 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-24 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-24 |
Time |
09:07 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-02-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-02-28 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-02-28 |
Time |
15:22 |
Sent To |
B |
|
| Notes |
| 2003-02-28 00:00:00 | TO HHP./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-02-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-20 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-20 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2003-02-20 00:00:00 | TO COMM BOARD #56 | | | B,P,E,F |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-01-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-17 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-16 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2003-01-17 00:00:00 | UP FRONT,DOWN BELOW WITH CONTRACTORS | | | NAME ON PLANS,CALLED./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-21 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-01-16 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-21 |
Time |
18:44 |
Sent To |
|
|
| Notes |
| 2002-11-21 00:00:00 | TO COMM BOARD # 48./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2003-09-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-09-25 |
Time |
12:44 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-09-25 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2003-09-25 00:00:00 | PROVISO: | | | PROVIDE MANUFACTURERS INSTALLATION | | | INSTRUCTIONS FOR THE SMOKE DAMPERS ON | | | JOBSITE FOR INSPECTION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-06-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-19 |
Time |
10:27 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-06-06 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-02-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-13 |
Time |
11:10 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-02-13 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2003-02-13 00:00:00 | PROVISO: | | | | | | ACCESS FOR RTU 5 & 6 SHALL NOT REQUIRE | | | CLIMBING OVER OBSTRUCTIONS GREATER THAN | | | 30" (2001 FBC(M) 306.5). | | | | | | ADDITIONAL PERMITS REQUIRED FOR HOOD, | | | FIRE SUPRESSION AND WALK-IN COOLERS. | | | PLEASE PROVIDE PLANS & MANUFACTURERS | | | SUBMITTAL DATA WITH PERMIT APPLICATION. | | | PLAN SHEET M-1 NOTE #13 INDICATES GREASE | | | DUCT TO BE WRAPPED WITH FIRE WRAP. | | | PROVIDE SUBMITTAL FOR THE FIRE WRAP | | | WITH HOOD PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-12-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-12-23 |
Time |
07:13 |
Rev Time |
1.30 |
| Received By |
pkrauss |
Date |
2002-12-23 |
Time |
06:36 |
Sent To |
|
|
| Notes |
| 2002-12-23 00:00:00 | HVAC NOTES: | | | PLAN SHEET M-1 PRESCHOOL RM 129, PLAN | | | INDICATES A FIRE DAMPER AT OVER THE DOOR | | | TO THIS ROOM.ARCHITECTURAL PLAN DOES | | | NOT INDICATE THIS AS A RATED WALL. | | | PLEASE CLARIFY. | | | | | | AS PER 2001 FBC(M) 306.5 EQUIPMENT | | | LOCATED ON ROOFS OR ELEVATED STRUCTURES, | | | ACCESS TO RTU'S #1, 2, 5 & 6 SHALL NOT | | | REQUIRE CLIMBING OVER OBSTRUCTIONS | | | GREATER THAN 30". | | | | | | PROVIDE INFORMATION ON THE ROOF RACK FOR | | | THE CONDENSING UNITS FOR THE WALK-IN | | | COOLER/FREEZER.SHOW COMPLIANCE WITH | | | 2001 FBC TABLE 1511.7 FOR THE STAND | | | CLEARANCE BETWEEN FINISHED ROOF & THE | | | BOTTOM OF THE SUPPORT RAIL. | | | | | | HOOD PLAN REVIEW: | | | ADDITIONAL PERMIT REQUIRED FOR HOOD. | | | PLAN SHEET M-1 DRAWING KEYNOTE #13, | | | INDICATES THE GREASE DUCT IN A 2 HR | | | SHAFT.PLEASE PROVIDE CROSS-SECTION | | | DETAIL OF UL RATED ASSEMBLY.INSPECTION | | | OF WELDS REQUIRED PRIOR TO COVERING | | | DUCTWORK. | | | | | | EXHAUST TERMINATION SHALL BE LOCATED NOT | | | LESS THAN 10 FT HORIZONTALLY FROM PARTS | | | OF THE SAME OR CONTIGUOUS BUILDINGS, | | | ADJACENT PROPERTY LINES & AIR INTAKE | | | OPENINGS.2001 FBC(M) 506.3.14.3. | | | | | | WALK-IN COOLER & FREEZER: | | | PROVIDE MANUFACTURER SUBMITTAL DATA & | | | INSTALLATION INSTRUCTIONS WITH PERMIT | | | APPLICATION. | | | | | | ADDITIONAL PERMIT REQUIRED FOR FIRE | | | SUPRESSION.PLEASE PROVIDE PLANS WITH | | | PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2003-08-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-06 |
Time |
18:46 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-08-06 |
Time |
18:46 |
Sent To |
|
|
| Notes |
| 2003-08-06 00:00:00 | REVISIONS OK - MOVED ROOF DRAINS ADDED | | | PIPING - ADDED SECONDARY ROOF DRAINS AND | | | ADDED PIPING - MOVED SINKS AND PIPING | | | ADDED BALANCING VALVES - DELETED A ROOF | | | DRAIN - MOVED A WATER HEATER LOCATION |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2003-06-14 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-14 |
Time |
09:58 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-06-14 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2003-06-14 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 ADMIN CODE, CHAPTER | | | 1, & AMENDMENTS. | | | | | | 1) SHT P-4 HOT WATER BALANCING VALVES | | | SHOWN ADDED ON SHT P-1 KEYNOTES #22 ARE | | | NOT SHOWN ON WATER RISER ISOMETRIC. | | | PLEASE ADD AND RESUBMIT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2003-03-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-26 |
Time |
16:12 |
Rev Time |
2.25 |
| Received By |
kstevens |
Date |
2003-03-26 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2003-03-26 00:00:00 | PASSED/PROVISO | | | | | | SEPARATE IRRIGATION PERMIT REQUIRED | | | | | | SEPARATE GAS PERMIT REQUIRED - FOLLOWING | | | INFORMATION REQUIRED AT TIME OF APPLIC- | | | ATION - TYPE OF GAS - DELIVERY PRESSURE- | | | MANUFACTURE SHEETS FOR GAS RANGE WITH | | | BTU'S SHOWN AND LISTED AGENCY. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2003-03-20 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-24 |
Time |
09:07 |
Rev Time |
3.00 |
| Received By |
kstevens |
Date |
2003-03-19 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2003-03-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | FBC-2001 FUEL GAS | | | | | | 1) RODNEY COMPO, ENVIRONMENTAL COMPLI- | | | ANCE HAS NOT BEEN CONTACTED AS OF YET. | | | I CALLED HIM AND THE CONTRACTOR AND THEY | | | WILL INFORM ME AS TO THE SIZE OF GREASE | | | TRAP THAT WILL BE REQUIRED. | | | 2) ROOF DRAIN/SCUPPER FOR 1803 SQ FT - | | | 1985 SQ FT COMBINATION IS NOT SUFFICIENT | | | FOR THIS AREA. MINIMUM OF 113 SQ IN | | | OPENING IS REQUIRED FOR THIS ROOF DRAIN/ | | | SCUPPER COMBINATION OPENING. | | | 3) RECOMMENDED LAV HEIGHT FOR CHILDREN | | | AGES 2 THRU 5 IS 20" TO 24". SEE ATTACH- | | | ED SHEET. | | | 4) GAS PERMIT WILL BE SEPARATE. INFOR- | | | MATION REQUIRED AT TIME OF APPLICATION, | | | TYPE OF GAS, - DELIVERY PRESSURE, - AND | | | MANUFACTURE SHEETS FOR GAS RANGE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-02-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-02-04 |
Time |
16:10 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-02-04 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2003-02-04 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 11 | | | | | | 1) FROM PREVIOUS REVIEW: ROUTE PLANS TO | | | PALM BEACH COUNTY HEALTH UNIT, DIVISION | | | OF ENVIRONMENTAL HEALTH, 901 EVERNIA ST. | | | WPB. PLANS SHALL BE STAMPED PRIOR TO RE- | | | SUBMITTING TO CITY FOR REVIEW. | | | 2) FROM PREVIOUS REVIEW: CONTACT RODNEY | | | COMPO, ENVIRONMENTAL COMPLIANCE, FOR | | | GREASE TRAP REQUIREMENTS. WASTE ORD | | | #2938-96. @ (561) 837-4074. | | | 3) FROM PREVIOUS REVIEW: SHT A1.1 ROOM | | | 104, DOOR SHALL NOT OPEN INTO THE CLEAR | | | FLOOR SPACE OF LAV. | | | 4) FROM PREVIOUS REVIEW: PLEASE INDICATE | | | CLEAR FLOOR SPACE FOR ALL HDCP FIXTURES. | | | SHOW 5' TURNING SPACE FOR EACH TOILET | | | ROOM. SHT A1.1 | | | 5) FROM PREVIOUS REVIEW: SHT A1.3 PLEASE | | | PROVIDE CALCULATIONS FOR PRIMARY AND | | | SECONDARY ROF DRAINS PER SECTIONS 1106, | | | & 1107. INCLUDE 1/2 AREA OF ALL VERTICAL | | | WALLS INCLUDING PARAPET WALLS. ALSO SHOW | | | LOCATIONS FOR ALL SECONDARY ROOF DRAINS. | | | 6) FROM PREVIOUS REVIEW: SHT A5.1, | | | SCUPPER DETAIL, PLESE INDICATE TOTAL | | | AREA OF SCUPPER OPENING. THE ONLY DIMEN- | | | SION IS 4" HIGH. | | | 7) FROM PREVIOUS REVIEW: SHT A6.2 ROOM | | | 115 DETAIL. SINK IN LOUNGE SHALL COMPLY | | | WITH 11-4.24 AND ALL SUBSECTIONS. PLEASE | | | SHOW ON DETAIL. (DETAIL #5 ONLY SHOWS | | | DETAIL FOR 11-4.24.2) | | | 8) FROM PREVIOUS REVIEW: SHT FS-3 ALL | | | INDIRECT WASTE SHALL DRAIN INTO A FLOOR | | | SINK. SECTION 802.3 (SHT P-3 CHANGED BUT | | | NOT FS-3) | | | 9) FROM PREVIOUS REVIEW: WILL THE FIX- | | | TURES FOR CHILDREN BE LOWERED PER ADA | | | GUIDLINES FOR BUILDINGS & FACILITIES; | | | BUILDING ELEMENTS DESIGNED FOR CHILDRENS | | | USE? (NO REPLY NOTED) | | | 10) FROM PREVIOUS REVIEW: FOR GAS REVIEW | | | SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE FBC- | | | 2001 FUEL GAS CODE SEC 402.2. | | | *********WHEN RESUBMITTING PLANS******** | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDEN- | | | TIFYING THE SHEET OR SPECIFICATION PAGE | | | WHERE THE CHANGES CAN BE FOUND, WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-12-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-12-26 |
Time |
09:10 |
Rev Time |
7.00 |
| Received By |
kstevens |
Date |
2002-12-26 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2002-12-26 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 11 | | | | | | 1) PLEASE ROUTE PLANS TO PALM BEACH | | | COUNTY HEALTH UNIT, DIVISION OF ENVIRON- | | | MENTAL HEALTH, 901 EVERNIA ST W.P.B | | | (561) 355-3018.SECTION 101.4.7 | | | 2) CONTACT RODNEY COMPO, ENVIRONMENTAL | | | COMPLIANCE, FOR GREASE TRAP REQUIREMENTS | | | WASTE ORD. #2938-96 (561) 837-4074 | | | 3) SHT D-1, NOTE G - DEMO PERMIT REQUIR- | | | ED FOR PLUMBING. | | | 4) SHT A1.1 ROOM 104, DOOR SHALL NOT | | | OPEN INTO THE CLEAR FLOOR SPACE OF LAV. | | | 5) PLEASE INDICATE CLEAR FLOOR SPACE FOR | | | ALL HDCP FIXTURES, AND SHOW 5' TURNING | | | RADIUS FOR EACH TOILET ROOM. | | | 6) SHT A1.3, PLEASE PROVIDE CALCULATIONS | | | FOR THE PRIMARY & SECONDARY ROOF DRAINS, | | | PER SECTIONS 1106 & 1107. INCLUDE 1/2 | | | AREA OF ALL VERTICAL WALLS. ALSO SHOW | | | LOCATION OF ALL SECONDARY ROOF DRAINS. | | | 7) SHT A5.1, SCUPPER DETAIL, PLEASE IN- | | | DICATE TOTAL AREA OF SCUPPER OPENING. | | | THE ONLY DIMENSION SHOWN IS 4" HIGH. | | | 8) SHT A6.2, ROOM 115 DETAIL, SINK IN | | | LOUNGE SHALL COMPLY WITH 4.24 AND ALL | | | SUBSECTIONS. PLEASE SHOW ON DETAIL. | | | 9) SHTS FS-3 & P-3 ALL INDIRECT WASTE | | | SHALL DRAIN INTO A FLOOR SINK. SECTION | | | 802.3. FUNNEL FLOOR DRAIN ON GREASE | | | SYSTEM NOT APPROVED. | | | 10) SHT P-2, GREASE TRAP DETAIL, PLEASE | | | SEE ATTACHED SHEET FOR APPROVED CITY OF | | | WEST PALM BEACH STANDARD GREASE TRAP DE- | | | TAIL. | | | 11) SHT P-3, STORM DRAIN ISOMETRIC, SIZE | | | OF STORM DRAINAGE PIPING REQUIRED FOR | | | BLDG. DRAIN. | | | 12) SHT P-4, WATER ISOMETRIC, AIR CHAMB- | | | ERS ARE NOT APPROVED, PLEASE DELETE FROM | | | ISO. ALL WATER HAMMER ARRESTORS REQUIRED | | | BY 604.9 SHALL BE LOCATED NEAR THE FIX- | | | TURES IN AN "EFFECTIVE RANGE" NOT IN | | | CEILING AT TOP OF DROP. | | | 13) WILL THE FIXTURES FOR CHILDREN BE | | | LOWERED PER ADA GUIDELINES FOR BUILDINGS | | | & FACILITIES; BUILDING ELEMENTS DESIGNED | | | FOR CHILDREN'S USE? | | | 14) FOLLOWING INFORMATION REQUIRED FOR | | | APPLICATION FOR GAS (SEPARATE) PERMIT. | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | SPECIFICATION BOOK SHOWS "A" COPPER | | | TUBING & "B" SCHED. 40 STEEL PIPE. | | | PLEASE CLAIRFY. | | | C. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). | | | D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | E. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. - UNION NOT | | | SHOWN ON PLANS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-01-16 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-01-16 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|