Plan Review Details - Permit 02111442
Plan Review Stops For Permit 02111442
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2004-05-05 Cont ID  
Sent By mmclean Date 2004-05-12 Time 15:31 Rev Time 1.00
Received By shill Date 2004-05-04 Time 18:15 Sent To E
Notes
2004-05-04 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)PROVIDE A HURRICANE SHUTTER
 INSTALLATION SCHEDULE OR A SEPARATE
 PERMIT WILL BE REQUIRED.
  
 2.)SEE PREVIOUS LISTS.A SITE PLAN
 IS REQUIRED.YOU CANNOT USE THE
 SITE PLAN (WHICH WAS NOT STAMPED BY
 ZONING) PREPARED BY ANOTHER DESIGN
 PROFESSIONAL.
  
 3.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION.
  
 4.)PROVIDE THE PERMIT APPLICATION AND
 THE OWNER/BUILDER AFFIDAVIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-01-29 Cont ID  
Sent By csiegber Date 2004-04-16 Time 16:37 Rev Time 2.00
Received By shill Date 2004-01-29 Time 12:00 Sent To  
Notes
2004-01-29 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SUBMIT TWO COPIES OF LEGIBLE,
 COMPLETE PRODUCT APPROVALS.SEPARATE
 PERMITS WILL BE REQUIRED FOR ANY ITEMS
 NOT PROPERLY SUBMITTED BEFORE ISSUANCE.
 PRODUCT APPROVALS MAY BE AVAILABLE AT
 WWW.MIAMIDADE.GOV (FIND A DEPARTMENT,
 BUILDING CODE COMPLIANCE, PRODUCT
 CONTROL SEARCH).
  
 2.)PROVIDE A HURRICANE SHUTTER
 INSTALLATION SCHEDULE AS PER MISSILE
 IMPACT POLICY, SEE ATTACHED.
  
 3.)THE APPROVED ZONING SITE PLAN
 IS NOT IN THE PACKAGE.PLEASE PROVIDE.
  
 4.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION.233-5025
  
 5.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 6.)SINGLE HUNG 24 AND 34 WINDOWS DO
 NOT COMPLY WITH FBC1005.4.
  
 7.)THE WINDOWS AT THE BATH TUBS ARE
 TO COMPLY WITH FBC2405.1 (SAFETY GLASS).
  
 8.)AS PER A CONVERSATION WITH THE
 HOMEOWNER, THE PLAN SHOWS TWO WINDOWS
 IN THE EXISTING BEDROOM ADJACENT TO THE
 ADDITION, BUT THERE IS ONLY ONE.PROVIDE
 A NEW WINDOW TO COMPLY WITH FBC1005.4
 TO PROVIDE EMERGENCY EGRESS FOR THE
 EXISTING BEDROOM.
  
 9.)TWO COPIES OF ENERGY CALCS
 REQUIRED, SIGN OWNER/AGENT LINE
 FBC13-101.2.
  
 10.) THE TITLE BLOCK FOR THE ENGINEER
 IS TO BE ON EVERY PAGE, INCLUDE THE
 LICENSE NUMBER FAC61G15-23.002.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-07-10 Cont ID  
Sent By pkrauss Date 2004-01-28 Time 12:56 Rev Time 0.00
Received By hpiskura Date 2003-07-09 Time 14:22 Sent To P
Notes
2003-07-10 00:00:00SHEET 1 DATED 6/30/03 SIGNED AND SEALED
 BY LESLIE E. COLBY, PE STILL HAS
 INFORMATION FOR 130 MPH WIND ZONE.AS
 PREVIOUSLY NOTED, THE CITY OF WEST PALM
 BEACH IS IN A 140 MPH WIND ZONE.ALSO,
 CUT AND PASTING OF THE CODE IS NOT A
 SUBSTITUTE FOR SPECIFIC DESIGN
 INFORMATION OR SOUND ENGINEERING
 PRACTICE.SEE FBC 104.2.1.
  
 SHEET 3 HAS A CUT AND PASTE OF SECTION
 2309.7 OF THE FBC.HOW WILL THE 4'X4'
 VENT SHOWN IN THE GABLE END ON SHEET 2
 PROVIDE CROSS VENTILATION?WHAT WILL
 BECOME OF THE EAVE VENTS ON THE
 EXISTING BUILDING WHEN THE ADDITION IS
 ATTACHED?
  
 SHEET 3 ROOFING LOADS.WHERE ARE THE
 LOAD COMBINATIONS FROM FBC 1609?HOW
 WAS THE WIND PRESSURE AND COEFFICIENTS
 DETERMINED?HOW DO THEY RELATE TO THE
 DECLARED "DESIGN CRITERIA" TABLE ON
 SHEET 2 WHICH HAS VARYING PRESSURES FOR
 COMPONENTS AND CLADDING, ROOF AND WALLS
 ANOTHER LABELED UPLIFT, PSF, ENDS, INT.
 AND STILL OTHER FIGURES ON THE SLIDING
 GLASS DOOR OF THE SOUTH ELEVATION?
 THE SAME TABLE HAS AN INTERNAL PRESSURE
 COEFFICIENT AS - 1.8.PLEASE EXPLAIN.
  
 SHEET 4 HAS COPIES OF ROBBINS TRUSS
 PLATE ENGINEERING, ONE DECLARING 110
 MPH 1994 SBCCI AND THE OTHER DECLARING
 ASCE 7-98 AND 130 MPH.WHAT MANNER OF
 DESIGN OR ENGINEERING IS INTENDED TO BE
 COMMUNICATED WITH THIS?
  
 THE PREVIOUSLY REQUESTED DESIGN FOR THE
 ATTACHMENT OF THE NEW TRUSSES TO THE
 EXISTING ROOF HAS NOT BEEN PROVIDED.
  
 IN VIEW OF THE ABOVE GLARING DESIGN
 DISCREPANCIES, PLEASE REVIEW THE
 RESPONSIBILITY RULES COMMON TO ALL
 ENGINEERS AND RULES CONCERNING THE
 DESIGN OF STRUCTURES CONTAINED IN
 CHAPTERS 61G15-30 AND 61G15-31 OF THE FL
 ADMINISTRATIVE CODE.
  
 AS NOTED ON THE PREVIOUS LIST, IMPACT
 FEES MUST BE PAID TO THE COUNTY,
 ADDITIONAL PERMIT FEES ARE DUE TO THE
 CITY AND IFPRODUCT APPROVALS FOR THE
 ROOF COVERING, WINDOWS, DOORS AND
 SHUTTERS WHERE APPICABLE, ARE NOT
 INCLUDED HERE, A SEPARATE PERMIT, PLANS
 AND FEES WILL BE REQUIRED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-12-20 Cont ID  
Sent By btrobaug Date 2002-12-16 Time 13:12 Rev Time 0.00
Received By hpiskura Date 2002-12-20 Time 10:24 Sent To  
Notes
2002-12-20 00:00:00BEFORE A PERMIT TO CONSTRUCT MAY BE
 ISSUED IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, THE PERMIT PLANS STAMPED
 BY THAT OFFICE AND A COPY OF THE PAID
 RECEIPT ATTACHED TO THE PERMIT
 APPLICATION.CALL 561-253-5025 FOR
 MORE INFORMATION.
  
 THE NOTES ON SHEET 2 AND ELSEWHERE
 REFERENCE THE WRONG WINDSPEED.WEST
 PALM BEACH IS IN A 140 MPH WIND ZONE.
 PLEASE REVISE AND ENSURE COMPLIANCE
 WITH SAME.
  
 HOW WERE THE ROOF LOADS ON SHEET 3
 DETERMINED?SEE FBC 1609.3.2 FOR LOAD
 COMBINATIONS.
  
 SOME PORTIONS OF THE PAGES TITLED "2002
 STRUCTURAL DETAILS" ARE ILLEGIBLE AND
 NOT FOR THE 140 MPH ZONE.WPB IS NOT
 INCLUDED IN THE HVHZ.
  
 PLEASE PROVIDE A BETTER FRAMING DETAIL
 FOR THE ROOF.SHOW THE TRANSITION OF
 THENEW TRUSSES TO THE EXISTING.
 CONNECTIONSAT THE EXISTING BEARING
 POINTS.SEE FBC 104.2
  
 PROVIDE A DETAIL FOR THE GABLE END
 DETAIL IN ACCORDANCE WITH FBC 2313.4.
  
 SHOW THE ATTIC ACCESS, FBC 2309.6.
  
 SHOW THE ATTIC VENTILATION, INCLUDING
 ASSUMED FREE AREA OF THE SCREEN VENTS
 TO BE USED.SEE FBC 2309.7.
  
 THE WINDOWS IN THE BATH TUB AREAS MUST
 COMPLY WITH FBC 2405.2.1 #2.
  
 IF PRODUCT APPROVALS FOR THE DOORS
 WINDOWS SHUTTERS AND ROOF COVERING ARE
 NOT INCLUDED WITH THIS PERMIT
 APPLICATION, A SEPARATE PERMIT AND FEES
 WILL BE REQUIRED.
  
 THE DECLARED PERMIT VALUATION OF
 $11,750.00 IS TOO LOW FOR THIS SCOPE OF
 WORK.
 PLEASE PAY THE CITY AN ADDITIONAL
 $893.39 BASED ON A CONSTRUCTION VALUE
 OF $60840.00

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-05-05 Cont ID  
Sent By shill Date 2004-05-12 Time 16:43 Rev Time 0.33
Received By dpalmer Date 2004-05-05 Time 06:06 Sent To P
Notes
2004-05-05 00:00:00*********** UNSAT **************
  
 1)NOTE: PLEASE SEE FAC/ FS, PLANS SIGNED
 AND SEALED BY AN ARCH/ ENG MUST CONTAIN
 A TITLE BCLOCK W/ ALL INFORMATION AS
 SET FORTH IN FAC 61G1-16.004, 61G15-23.
 002.
  
 2)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
 SERVICE NEW?
  
 3)) NOTE: PLEASE SEE MISSING RECEPTS FOR
 FRONT AND/OR REAR OF DWELLING.
 210.52E
  
 4) NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ON EACH LEVEL OF A MULTI-LEVEL DWELLING
 UNIT.
 IN CLOSE PROXIMITY OF STAIRWAYS LEADING
 TO FLOORS ABOVE AND IN THE VICINITY OF
 BEDROOMS.
 PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE
 A MIN OF 3' FROM BATHROOM DOORS AND
 KITCHENS.
 ABOVE PER:FBC 905.2, NFPA-72 8-1.4
 MASTER BEDROOM.
  
 5 )NOTE: PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CURCUIT(S) ON PANEL
 SCHEDULE. PLEASE SEE THAT ALL "OUTLETS"
 IN BEDROOMS ARE TO BE PROTECTED ,
 INCLUDING, LTS, RECEPTS, SD'S ETC.
 2002 NEC 210.12
  
 6)NOTE: PLEASE SEE MAX OCP FOR WATER
 HEATER IS 150%, MIN 125%/ SHOWN AS 2P30A
 FOR 3.5 KW.
  
 7)NOTE; PLEASE SEE FBC, ADDITIONS TO
 EXISTING DWELLINGS OF 25% OR MORE.
 PLEASE SHOW ALL EXISITING ELECTRICAL
 THAT MEETS CODE AND/OR NEW ELECTRICAL
 THAT IS REQ'D TO BROUGHT UP TO CODE
 IN EXSITING BLDG. RECEPT/LTS/SD'S ETC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-12-16 Cont ID  
Sent By shill Date 2004-05-04 Time 18:20 Rev Time 0.50
Received By btrobaug Date 2002-12-16 Time 12:41 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-05-10 Cont ID  
Sent By shill Date 2004-05-10 Time 15:26 Rev Time 0.00
Received By shill Date 2004-05-10 Time 15:26 Sent To Z
Notes
2004-05-10 00:00:00OWNER BROUGHT IN SITE PLAN

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-04-16 Cont ID  
Sent By csiegber Date 2004-04-16 Time 16:37 Rev Time 0.00
Received By csiegber Date 2004-04-16 Time 16:37 Sent To B
Notes
2004-04-16 00:00:00TO SH DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-01-16 Cont ID  
Sent By csiegber Date 2004-01-16 Time 13:40 Rev Time 0.00
Received By csiegber Date 2004-01-16 Time 13:40 Sent To P
Notes
2004-01-16 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-10 Cont ID  
Sent By shernand Date 2003-07-10 Time 11:35 Rev Time 0.00
Received By shernand Date 2003-07-10 Time 11:35 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-07 Cont ID  
Sent By shernand Date 2003-07-07 Time 09:25 Rev Time 0.00
Received By shernand Date 2003-07-07 Time 09:24 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-27 Cont ID  
Sent By btrobaug Date 2002-11-27 Time 10:45 Rev Time 0.00
Received By btrobaug Date 2002-11-27 Time 10:45 Sent To Z
Notes
2002-11-27 00:00:00CALLED OWNER FOR 2ND SET OF PLANS 11/26
 BROUGHT IN 11/27. /WRT

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2004-01-28 Cont ID  
Sent By pkrauss Date 2004-01-28 Time 12:52 Rev Time 0.15
Received By pkrauss Date 2004-01-28 Time 12:47 Sent To B
Notes
2004-01-28 00:00:00MECHANICAL CONTRACTOR IS NOT INDICATED
 ON BUILDING PERMIT APPLICATION.
 MECHANICAL PERMIT REQUIRED.PLEASE
 PROVIDE PLANS WITH MECHANICAL PERMIT
 APPLICATION.ENERGY CALCULATIONS
 SUBMITTED WITH BUILDING PERMIT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2003-07-08 Cont ID  
Sent By kstevens Date 2004-01-24 Time 10:58 Rev Time 0.20
Received By pkrauss Date 2003-07-08 Time 16:35 Sent To  
Notes
2003-07-08 00:00:00NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.PLEASE PROVIDE A COMPLETED FORM
 600C AS PER FBC CHAPTER 13 SUB-CHAPTER
 6.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-12-09 Cont ID  
Sent By shernand Date 2003-07-07 Time 09:25 Rev Time 0.30
Received By pkrauss Date   Time   Sent To E
Notes
2002-12-09 00:00:00DENIED:NO PLANS SUBMITTED FOR REVIEW
  
 PLEASE PROVIDE ENERGY & MANUAL J CALCS.
 INDICATE MAKE, MODEL, BTU'S FOR AHU &
 MAKE, MODEL & SEER OF THE CONDENSER
 UNIT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 4 Status F Date 2004-05-08 Cont ID  
Sent By jleech Date 2004-05-08 Time 13:31 Rev Time 0.50
Received By jleech Date 2004-05-08 Time 13:31 Sent To B
Notes
2004-05-08 00:00:00DENIED;
 RISER DIAGRAM DOES NOT REFLECT FLOOR
 PLAN. RISER DIAGRAM SHOULD SHOW WORK TO
 BE DONE. IS ALL THE DRAINAGE PIPE TO BE
 REPLACED?
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 3 Status F Date 2004-01-24 Cont ID  
Sent By dpalmer Date 2004-05-05 Time 06:09 Rev Time 0.25
Received By kstevens Date 2004-01-24 Time 10:58 Sent To M
Notes
2004-01-24 00:00:00DENIED
 REFERENCE: FLORIDA ADMIN. CODE
 FLORIDA STATUTES
  
  
 ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025

Review Stop P PLUMBING
Rev No 2 Status N Date 2003-07-12 Cont ID  
Sent By csiegber Date 2004-01-16 Time 13:40 Rev Time 0.25
Received By kstevens Date 2003-07-12 Time 05:34 Sent To  
Notes
2003-07-12 00:00:00NO PLUMBING PLANS SUBMITTED

Review Stop P PLUMBING
Rev No 1 Status N Date 2002-12-06 Cont ID  
Sent By kstevens Date 2002-12-06 Time 16:15 Rev Time 0.25
Received By kstevens Date 2002-12-06 Time 16:15 Sent To M
Notes
2002-12-06 00:00:00NO PLUMBING TO REVIEW

Review Stop Z ZONING
Rev No 2 Status P Date 2004-05-12 Cont ID  
Sent By shill Date 2004-05-10 Time 15:27 Rev Time 0.00
Received By mmclean Date 2004-05-12 Time 15:31 Sent To B
Notes
2004-05-12 00:00:00PASS RESUB. CALLED OWNER FOR P/U FILE
 M

Review Stop Z ZONING
Rev No 1 Status P Date 2002-12-03 Cont ID  
Sent By btrobaug Date 2002-11-27 Time 10:45 Rev Time 0.25
Received By sgraham Date   Time   Sent To B
Notes
***NONE***