Plan Review Details - Permit 02111254
Plan Review Stops For Permit 02111254
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2003-02-25 Cont ID  
Sent By jgomez Date 2003-02-25 Time 13:24 Rev Time 1.50
Received By jgomez Date 2003-02-25 Time 13:24 Sent To  
Notes
2003-02-25 00:00:00REVISION CHECKLIST:
 1-DRAWINGS SHOW THAT ATTIC ACCESS WAS
 DELETED. NEED ATTIC ACCESS AS REQUIRED
 BY SEC. 2309.6 FBC 2001.
 2-SEE COMMENTS ON PLANS & REVISE/CLARIFY
 AS REQUIRED.
 3-BUILDING REVIEW WAS APPROVED 1-24-03
 WITH THE PROVISO (CONDITION) THAT
 OWNER WAS GOING TO SUBMIT ADDITIONAL
 INFORMATION PRIOR TO CONSTRUCTION OR
 INSTALLATION. SUCH INFORMATION HAS NOT
 BEING PROVIDED YET. NEED TO PROVIDE
 INFORMATION TO AVOID DELAYS OR
 CONFLICTS. SEE ATTACHED COPY OF SUCH
 PROVISO.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-01-24 Cont ID  
Sent By jgomez Date 2003-01-24 Time 13:30 Rev Time 3.50
Received By jgomez Date 2003-01-24 Time 13:30 Sent To  
Notes
2003-01-24 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-CLAY FLUE LININGS ARE TO BE USED ON
 MASONRY CHIMNEYS. CHIMNEY SHOWN ON
 PLANS IS WOOD FRAMED. THEREFORE, NEED
 APPROPRIATE FLUE FOR FRAMED WALLS.
 PROVIDE UL LISTING AND SPECS AS REQ'D
 BY SEC. 2804.4 FBC 2001.
 2-MATERIALS USED FOR CHIMNEY EXTENSION
 AND FLUE EXTENSION MUST BE IN CONFOR-
 MANCE WITH EXISTING FIREPLACE SPECS &
 UL LISTING. PROVIDE COMPLETE INFORMA-
 TION TO VERIFY THAT PROPOSED CHIMNEY &
 FLUE EXTENSION ARE ADEQUATE AND SAFE
 TO USE WITHOUT AFFECTING THE FIREPLACE
 PERFORMANCE. PROVIDE INFORMATION
 FOR MECHANICAL PLANS EXAMINER FOR
 APPROVAL PRIOR TO INSTALLATION AND
 CONSTRUCTION.
 3-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS PRIOR TO INSTALLATION. (TWO)
 4-PROVIDE 2 COPIES OF PRODUCT APPROVALS
 FOR: A)ROOF TILE. B)FRENCH DOOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-01-21 Cont ID  
Sent By rmcdouga Date 2003-01-21 Time 11:43 Rev Time 3.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-01-21 00:00:00BUILDING DENIED
  
 1) SHEETS A1 AND A2 DO NOT HAVE THE
 EMBOSSED SEAL OF ARCHITECT THAT SIGNED
 THE PLANS.
  
 2) A1 OF PLANS INDICATE PLYWOOD WILL BE
 USED AS THE OPENING PROTECTION FOR THE
 FRENCH DOOR. THIS IS ALLOWED WHERE
 WIND SPEEDS DO NOT EXCEED 130 MPH,
 HOWEVER THE WIND SPEED FOR THE CITY OF
 WPB IS 140 MPH. PLEASE SUBMIT PRODUCT
 APPROVALS FOR STORM PANELS. FBC 1606.1.4
  
 3)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - NEW EXTERIOR DOORS
 - STORM PANELS
  
 4) PROVIDE ENERGY CALCULATIONS AS
 REQIRED BY FBC CHAPTER 13.
  
 5) DETAIL #3 ON A1 SPECIFIES A MINIMUM
 OF R12 INSULATION IN THE ATTIC. THE FBC
 CHAPTER 13 SECTION 604.1 REQUIRES
 CEILINGS TO HAVE AN INSULATION LEVEL OF
 AT LEAST R-19.
  
 6) SPECIFY THE SIZE AND SPACING OF THE
 TAPCONS INDICATED IN DETAIL #7 ON A1.
 PLEASE CLARIFY IF THE BRICK VENEER THAT
 THE NEW WALLS ARE BEING ATTACHED TO IS
 A STRUCTURAL ELEMENT.
  
 7) PROVIDE THE UL LISTING INFORMATION
 AND MANUFACTURER'S SPECS. FOR THE PRE-
 FABRICATED FLUE PIPE. FBC 2804.4.
  
 8) AN EXTERIOR DOOR FROM THE CLOSET TO
 THE DECK IS SHOWN ON THE FLOOR PLAN AND
 THE HVAC/ELEC PLAN ON A1, BUT NOT ON THE
 EAST ELEVATION ON SHEET A2. PLAESE
 CLARIFY.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-01-06 Cont ID  
Sent By btrobaug Date 2003-01-16 Time 16:45 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-01-06 00:00:00BUILDING DENIED
  
 COMMENTS FROM FIRST REVIEW HAVE NOT BEEN
 ADDRESSED. SAME COMMENTS AS FIRSTW
 REVIEW.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-12-19 Cont ID  
Sent By dpalmer Date 2002-12-27 Time 10:03 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-12-19 00:00:00BUILDING DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 3) PROVIDE ELEVATION, FLOOR PLAN,
 FOUNDATION PLAN AND WALL SECTION OF THE
 EXISTING STRUCTURE OF THE AREA WHERE THE
 ADDITION IS TO BE CONSTRUCTED.
  
 4) INDICATE ON THE PLANS HOW THE ROOMS
 ADJACENT TO THE ADDITION WILL COMPLY
 WITH EMERGENCY EGRESS REQUIREMENTS. SEE
 FBC 1005.4.
  
 5) INDICATE ON THE PLANS THE GUARDRAIL
 HEIGHT AND THE SPACING BETWEEN THE
 INTERMEDIATE RAILS.SEE FBC 1015 & 1026.5
  
 6) PROVIDE A FLOOR FRAMING PLAN FOR THE
 ADDITION. SPECIFY THE JOIST SIZE,
 SPACING, ETC.
  
 7) SPECIFY ALL STRAPS, CONNECTORS,
 ANCHORS, ETC. THAT WILL BE USED TO
 PROVIDE A CONTINOUS LOAD PATH FROM THE
 ROOF TRUSSES TO THE FOUNDATION.
  
 8) NUMBER 3 ON A1 INDICATES 2X6 METAL
 STUDS AND #6 SPECIFIES 2X6 WOOD STUDS.
 PLEASE CLARIFY. IF USING METAL STUDS,
 SPECIFY THE GUAGE.
  
 9) SPECIFY THE ROOF SHEATHING NAILING
 REQUIREMENTS AS REQUIRED BY THE CITY OF
 WPB AMENDMENTS TO THE FBC TABLE 2306.1.
  
 10) REVIEW FOR SHEAR WALL REQUIREMENTS.
 SPECIFY HOW SHEAR WALL REQUIREMENTS WILL
 BE ACCOMPLISHED. SEE FBC 2308.2 FOR
 EXTERIOR WALL BRACING REQUIREMENTS
 USING STRUCTURAL WALL PANELS.
  
 11) SPECIFY ALL CONNECTORS THAT WILL BE
 USED TO RESIST UPLIFT AND OVERTURNING
 LOAD. (HOLDDOWNS,STRAPS,ETC.)
  
 12) CHECK FOR HORIZONTAL DIAPHRAM
 REQUIREMENTS. SPECIFY HOW THIS WILL BE
 ACCOMPLISHED. SEE FBC 2310.
  
 13)FL BLD CODE 2309.6 ATTIC ACCESS,
 INDICATE OPENING SIZE.
  
 14) SPECIFY ATTIC VENTILATION PER FBC
 2309.7.
  
 15) SPECIFY BRACING FOR GABLE END PER
 FBC 2313.4.
  
 16) SPECIFY THE CONNECTION BETWEEN THE
 NEW WALLS AND THE EXISTING STRUCTURE.
 INDICATE THE TYPE OF CONSTRUCTION OF THE
 EXISTING STRUCTURE. FBC 104.1.5
  
 17) PROVIDE STRUCTURAL DETAILS FOR THE
 CONSTRUCTION OF THE CHIMNEY EXTENSION.
 FBC 104.1.5
  
 18) PROVIDE LISTING INFORMATION AND
 MANUFACTURER'S SPECIFICATIONS FOR THE
 PREFAB CHIMNEY PIPE. FBC 2804.4
  
 19) INDICATE THE ROOF PITCH, MEAN ROOF
 HEIGHT, WALL HEIGHTS, ETC. FBC 104.1.5
  
 20)FL BLD CODE CHAP 13 ENERGY EFFICENCY
 PROVIDE ENERGY CALS/ W MANUAL "J"
 OWNER/AGENT IS REQUIRED TO SIGN AND DATE
 FORM.
  
 21) SPECIFY CEILING INSULATION AS
 REQUIRED BY FBC CHAPTER 13.
  
 22) SPECIFY ON THE DECK EXTENSION DETAIL
 ON A2 IF POST IS EMBEDDED IN CONCRETE.
 INDICATE HOW UPLIFT AND GRAVITY LOADS
 ARE BEING RESISTED. INDICATE THE TYPE OF
 PRESERVATIVE TREATMENT. SEE FBC 1805,
 1811 AND 1606.
  
 22) PROVIDE DOOR BUCK DETAILS. SEE FBC
 1707.4.4.
  
 23) SPECIFY THE POSITIVE AND NEGATIVE
 WINDLOAD PRESSURE (PSF) AT NEW DOOR
 OPENING. FBC 1606.1.7
  
 24) INDICATE OPENING PROTECTION FOR
 GLAZING IN FRENCH DOOR. FBC 1606.1.4
  
 25) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - FRENCH DOOR
 - STORM PANELS
  
 26) THE ARCHITECT IS REQUIRED TO SIGN
 AND DATE THE DRAWINGS, IN ADDITION TO
 EMBOSSING THEM. A SIGNATURE STAMP IS NOT
 ACCEPTABLE. SEE FAC 61G
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2003-03-07 Cont ID  
Sent By pkrauss Date 2003-03-07 Time 08:45 Rev Time 0.40
Received By pkrauss Date 2003-02-24 Time 12:25 Sent To  
Notes
2003-03-07 00:00:00RECEIVED SUBMITTALS 3-7-03 - JOB WAS
 C.O.'D ON THE 4TH (3-4-03).

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-12-27 Cont ID  
Sent By btrobaug Date 2003-02-18 Time 17:12 Rev Time 0.25
Received By dpalmer Date 2002-12-27 Time 10:03 Sent To B
Notes
2002-12-27 00:00:00TO ROBERT MCDOUGAL DESK'S

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-12-17 Cont ID  
Sent By pkrauss Date 2002-12-27 Time 08:53 Rev Time 0.25
Received By btrobaug Date 2002-12-17 Time 10:36 Sent To M
Notes
2002-12-17 00:00:00DENIED
 ~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE NOTE THAT ALL PLANS
 THAT ARE SIGNED AND SEALED BY ARCH/ OR
 ENGINEER ARE REQ`D PER 61G15-23.002 FOR
 ENGINEER AND 61G1-16.004 FOR ARCH.
 SHALL HAVE A TITLE BLOCK AS SPECIFIED
 IN 61G1-16.004.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 561/659-8096 EXT. 8392

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-02-18 Cont ID  
Sent By btrobaug Date 2003-02-18 Time 17:11 Rev Time 0.00
Received By btrobaug Date 2003-02-18 Time 17:11 Sent To E
Notes
2003-02-18 00:00:00TO WRT./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-16 Cont ID  
Sent By btrobaug Date 2003-01-16 Time 13:27 Rev Time 0.00
Received By btrobaug Date 2003-01-15 Time 13:27 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-20 Cont ID  
Sent By btrobaug Date 2002-11-20 Time 15:29 Rev Time 0.00
Received By btrobaug Date 2002-11-19 Time 15:29 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By pkrauss Date 2003-03-07 Time 08:01 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-01-24 Cont ID  
Sent By pkrauss Date 2003-01-24 Time 11:02 Rev Time 0.25
Received By pkrauss Date 2003-01-24 Time 11:02 Sent To  
Notes
2003-01-24 00:00:00PROVISO:
  
 PLEASE PROVIDE MANUFACTURER INSTALLATION
 INSTRUCTIONS FOR THE FIREPLACE.
 MODIFICATION OF FLUE SHALL BE IN
 ACCORDANCE WITH MANUFACTURER'S
 SPECIFICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-12-27 Cont ID  
Sent By pkrauss Date 2002-12-27 Time 08:44 Rev Time 0.25
Received By pkrauss Date 2002-12-27 Time 08:37 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-12-17 Cont ID  
Sent By btrobaug Date 2002-12-17 Time 10:38 Rev Time 0.33
Received By hmoser Date 2002-12-17 Time 17:56 Sent To R
Notes
2002-12-17 00:00:00PLAN DENIED
 1) NO DUCT SIZE,CFM,GRILL SIZE ON PLAN
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 1 Status N Date 2002-12-19 Cont ID  
Sent By rmcdouga Date 2002-12-19 Time 08:59 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2002-12-03 Cont ID  
Sent By sgraham Date 2002-12-03 Time 12:28 Rev Time 0.25
Received By sgraham Date   Time   Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-11-27 Cont ID  
Sent By btrobaug Date 2002-11-20 Time 15:29 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-11-27 00:00:00DENIED NEED SITE PLAN