| Plan Review Stops For Permit 02111251 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2003-09-11 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-09-11 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-09-11 00:00:00 | REVISIONS DATED 9/5/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-07-29 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-07-29 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-07-29 00:00:00 | SHEET A100 DATED 7/16/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-06-19 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-06-19 00:00:00 | REVISONS DATED 6/2/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-02-10 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-02-10 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-02-10 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2003-02-10 00:00:00 | REVISIONS DATED 1/28/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-12-16 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-12-16 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-12-16 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2002-12-16 00:00:00 | THE EXITS AS SHOWN DO NOT MEET THE | | | MINIMUM 1/3 DIAGONAL DISTANCE FOR | | | SEPARATION IN ACCORDANCE WITH FBC | | | 1004.1.4.PLEASE REVISE AS NECESSARY. | | | (EGRESS IS NOT PERMITTED THROUGH | | | KITCHENS FBC 1001.1.3.) | | | | | | SHOW THE COUNTER AS COMPYING WITH THE | | | HANDICAP REQUIREMENTS OF FBC 11-5.2. | | | | | | SHOW THE COMPONENT AND CLADDING | | | PRESSURES FOR THE NEW STOREFRONT | | | SYSTEM.SEE FBC 1606.1.7. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2003-09-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-09-15 |
Time |
13:55 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-09-15 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2003-09-15 00:00:00 | REDLINED POSSIBLE EQUIPMENT GRND | | | FROM MAINS TO PANELS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2003-07-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-23 |
Time |
09:18 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-07-23 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2003-07-23 00:00:00 | NOTE REDLINED FOR EQUIPMENT GROUNDING | | | CONDUCTOR AND SPACE FOR PANELS 110-26 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-09 |
Time |
07:51 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-07-09 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-30 |
Time |
16:37 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-06-19 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2003-06-19 00:00:00 | ************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE 700-12E. PLEASE | | | CIRCUIT EXT AND EM LT AND CORRELATE | | | W/ A SUBMIT REVISED PANEL SCHEDULE. | | | PLEASE NOTE, THIS WAS NOTED AND REDLINED | | | ON PREVIOUS TWO REVIEWS. | | | | | | 2)NOTE: PLEASE ALSO SUBMIT REVISED | | | RISER DIAGRAM W/ EQUIPMENT GROUNDING | | | CONDUCTOR BETWEEN MAIN AND PANEL. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEYPALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected]. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-02-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-11 |
Time |
07:22 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-02-11 |
Time |
07:22 |
Sent To |
|
|
| Notes |
| 2003-02-11 00:00:00 | NOTED FOR 700-12E, 2ND TIME. | | | MISSING EQUIPMENT GROUNDING BETWEEN "E" | | | AND "LP". |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-25 |
Time |
06:19 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2002-11-25 |
Time |
06:19 |
Sent To |
|
|
| Notes |
| 2002-11-25 00:00:00 | ************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE, PLANS MUST CONTAIN | | | ORIG SIGNATURE FROM THE ENGINEER/ARCH | | | OF RECORD. AN INK STAMP IS NOT ACCEPTED | | | BY FS 471.025/481.221. | | | | | | 2)NOTE: PLEASE NOTE, LOAD CALCULATIONS | | | NEED TO BE SHOWN, PLEASE NOTE ALL | | | CONTINUOUS LOADS ARE TO BE SHOWN AT | | | 125% 230-42/215-3 | | | | | | 3)NOTE: PLEASE NOTE, ALL CIRCUITING | | | NEEDS TO BE SHOWN, PLEASE NOTE, CIRCUITS | | | FOR EM/EXT LTS PER 700-12E. | | | | | | 4)NOTE: PLEASE NOTE, SHOW WINDOW RECEPTS | | | REQ`D 210-62. | | | | | | 5)NOTE: PLEASE CLARIFY MEANS OF EQUIP- | | | -MENT GROUNDING BETWEEN MAIN DISC AND | | | PANEL "E".EQUIP GRND, SIZE PER 250-122 | | | | | | 6)NOTE: PLEASE SUBMIT AIC RATING FOR | | | NEW MAIN DISCONNECT SHOWN. | | | MAINS/PANELS/BREAKERS ALL MUST BE RATED | | | FOR THE AVAILABLE FAULT CURRENT PER | | | 110-9. | | | | | | 7)NOTE: PLEASE PROVIDE LOAD FOR EXISTING | | | MAIN. PLEASE NOTE, THIS SERVICE IS | | | SHOWN ADDING 197A`S. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2003-09-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-09-10 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-09-10 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2003-09-10 00:00:00 | FIRE ALARM EQUIPMENT IS REQUIRED. COULD | | | NOT LOCATE FIRE ALARM EQUIPMENT ON | | | THE PLANS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2003-07-24 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-07-24 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-07-24 |
Time |
16:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-07-07 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-07-07 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-07-07 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2003-07-07 00:00:00 | REVISION 6-09-03NAM |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-02-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-02-06 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-02-06 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-12-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-12-05 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-12-05 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2002-12-05 00:00:00 | 1) PLANS DO NOT INDICATE ANY INTERIOR | | | FINISH CLASSIFICATION FOR THE WALLS | | | AND CEILINGS. | | | | | | 2) TABLES AND CHAIRS APPEAR TO BE TOO | | | CLOSE TOGETHER IN SOME LOCATIONS. | | | | | | 3) AN EXIT SIGN IS PRESENT DIRECTING | | | PERSONS TO EXIT THU KITCHEN. THIS IS | | | NOT ALLOWED. PLEASE REVISE PLANS AS | | | NECESSARY. | | | | | | 4) NO FIRE ALARM EQUIPMENT SHOWN IN | | | TENANT SPACE. PLEASE DISPLAY FIRE | | | ALARM EQUIPMENT ON THE PLANS. | | | | | | 5) PLEASE EXPLAIN HOW THE TWO EXITS | | | LOCATED AWAY FROM THE KITCHEN ARE | | | PROPERLY SEPARATED FROM ONE ANOTHER. | | | | | | 6) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR ANY HOOD, DUCT, AND FIRE SUPPRESSION | | | SYSTEMS PLANNED FOR THE LOCATION. | | | | | | 7) SEPARATE PLANS AND PERMITS FOR FIRE | | | ALARM EQUIPMENT. | | | | | | 8) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE SPRINKLER MODIFICATIONS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2003-09-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-09 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-09 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2003-09-09 00:00:00 | ON COMM BD#28 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2003-09-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-04 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-04 |
Time |
09:34 |
Sent To |
P |
|
| Notes |
| 2003-09-04 00:00:00 | 9/4/03 REV DRAWINGS/P |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-08-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-25 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-25 |
Time |
15:38 |
Sent To |
M |
|
| Notes |
| 2003-08-25 00:00:00 | TO PK DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-07-17 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-17 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-17 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2003-07-17 00:00:00 | COMM BOARD #12 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-06-30 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-30 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-30 |
Time |
16:37 |
Sent To |
E |
|
| Notes |
| 2003-06-30 00:00:00 | DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-06-09 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-09 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-09 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2003-06-09 00:00:00 | COMM BOARD #58 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-03-31 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-31 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-31 |
Time |
15:55 |
Sent To |
P |
|
| Notes |
| 2003-03-31 00:00:00 | TO PLUMBING IN BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-02-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-04 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-04 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2003-02-04 00:00:00 | TO COMM BOARD # 25 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-20 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-19 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2002-11-20 00:00:00 | TO COMM BOARD# 50./WRT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2003-09-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-09-17 |
Time |
06:46 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-09-17 |
Time |
06:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2003-08-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-08-27 |
Time |
14:29 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-08-27 |
Time |
14:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-25 |
Time |
15:39 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-06-23 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2003-06-23 00:00:00 | PROVISO: | | | | | | CONDENSER UNIT STANDS SHALL COMPLY WITH | | | 2001 FBC 1511.7.SEE ATTACHED | | | | | | DUCT SMOKE DETECTOR SHALL BE ACTIVATE | | | ALARM/STROBE IN NORMALLY OCCUPIED AREAS | | | OR ACTIVATE ALARM STROBE AT A CONSTANTLY | | | ATTENDED LOCATION. 2001 FBC(M) 606.4. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-02-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-12 |
Time |
14:08 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-02-12 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2003-02-12 00:00:00 | PROVISO: | | | PROVIDE SUBMITTAL FOR THE CONDENSER | | | UNIT ROOF STANDS.SHOW COMPLIANCE | | | WITH 2001 FBC 1511.7 FOR CLEARANCE | | | REQUIREMENTS ABOVE FINISHED ROOF. | | | | | | ADDITIONAL PERMITS REQUIRED FOR HOOD, | | | FIRE SUPRESSION & WALK-IN COOLERS. | | | PROVIDE PLANS AND MANUFACTURER SUBMITTAL | | | DATA WITH PERMIT APPLICATIONS.PROVIDE | | | AIR BALANCE SCHEDULE FOR HOOD | | | EXHAUST/MAKEUP. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-12-17 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-12-17 |
Time |
17:01 |
Rev Time |
0.75 |
| Received By |
hmoser |
Date |
2002-12-17 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2002-12-17 00:00:00 | PLAN DENIED | | | 1) PLANS SHOW SPLIT SYSTEM.EQUIPMENT | | | SCHEDULE CALLS FOR ROOF TOP PACKAGE | | | UNITS. | | | 2) ONE FLEX DUCT SIZE NOT MARKED ON | | | A/C #3 | | | PLAN REVIEW BY HAROLD MOSER | | | (561)659-8096 EXT.8390 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2003-09-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-17 |
Time |
10:29 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-09-17 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2003-09-17 00:00:00 | PASSED/PROVISO - RED LINE CORRECTIONS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2003-09-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-17 |
Time |
10:03 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-09-09 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2003-09-17 00:00:00 | PASSED/PROVISO - REVISION TO GAS SYSTEM | | | SEE RED LINE CORRECTIONS BECAUSE OF INFO | | | FROM MANUF. INFORMATION AND GAS CONTR. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2003-07-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-04 |
Time |
09:35 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-07-23 |
Time |
18:06 |
Sent To |
|
|
| Notes |
| 2003-07-26 00:00:00 | DENIED | | | REFERENCE: FBC-2001 FUEL GAS | | | | | | 1) SLEEVE IN CONCRETE NOT APPROVED. | | | APPROVED METHOD FOR INSTALLING PIPE IN | | | CONCRETE FLOOR SHALL COMPLY WITH SECTION | | | 404.6.1(2). CONCRETE SHALL BE CUT OUT, | | | PIPE INSTALLED, PAINTED WITH A BITUMIN- | | | OUS PAINT AND COVERED WITH A LIGHTWEIGHT | | | CONCRETE SO THAT THE PIPE CAN BE REMOVED | | | IF REQUIRED. | | | 2) SEE PROVISO FOR APPLICATION FOR GAS | | | PERMIT ON SHEET P-101 OF THE APPROVED | | | PLANS. AT THIS TIME NO GAS PERMIT HAS | | | BEEN APPLIED FOR. | | | 3) THE HOOD SHUT DOWN SHALL BE BELOW THE | | | CEILING, BUT DOES NOT HAVE TO BE AT | | | CEILING HEIGHT. (INFORMATIONAL) | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2003-07-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-01 |
Time |
08:42 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2003-06-30 |
Time |
18:56 |
Sent To |
|
|
| Notes |
| 2003-07-01 00:00:00 | DENIED | | | REFERENCE: FBC-2001 FUEL GAS | | | | | | 1. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. THESE | | | VALVES AND UNION ARE NOT SHOWN ON RISER. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-04-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-01 |
Time |
13:08 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2003-04-01 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2003-04-01 00:00:00 | PASSED/PROVISO | | | | | | PER DEPT. OF BUSINESS AND PROFESSIONAL | | | REGULATION REVIEW, A DIPPERWELL IS REQ- | | | UIRED. A REVISION IS REQUIRED FOR THE | | | FLOOR PLAN, SANT. RISER AND WATER RISER | | | SHOWING DIPPERWELL. | | | | | | SEPARATE GAS PERMIT REQUIRED. GAS REQ- | | | UIREMENTS TO BE SUBMITTED AT TIME OF | | | APPLICATION. | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. | | | 2. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). | | | 3. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | 4. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-02-05 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-31 |
Time |
15:55 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-02-05 |
Time |
17:31 |
Sent To |
|
|
| Notes |
| 2003-02-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 11 | | | | | | 1) FROM PREVIOUS REVIEW: PLANS SHALL BE | | | ROUTED TO DEPT. OF BUSINESS REGULATION | | | HOTEL & RESTURANT DIVISION PRIOR TO RE- | | | SUBMITTING TO CITY FOR REVIEW. PLANS | | | SHALL BE STAMPED AND WORK SHEETS ATTACH- | | | ED TO PLANS. | | | 2) FROM PREVIOUS REVIEW: SHT P101 WATER | | | RISER DIAGRAM, WATER HAMMER ARRESTORS | | | SHALL BE LOCATED NEAR THE FIXTURE IN AN | | | "EFFECTIVE RANGE" NOT AT THE TOP OF THE | | | DROP IN THE CEILING. PER PDI-WH 201 AND | | | MANUF. INSTALLATION INSTRUCTIONS. | | | 3) DELIVERY PERSSURE OF 2LBS WILL ALLOW | | | 11,415,000 BTU'S. ON 1-1/4" PIPE. MAY | | | I SUGGEST A 1/2 LB. SYSTEM THAT WILL | | | ALLOW 950,OOO BTU'S FOR 1-1/4" PIPE, AND | | | YOU WILL NOT NEED REGULATORS FROM 2LBS. | | | 4) FROM PREVIOUS REVIEW:******** | | | A. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | B. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-12-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-12-14 |
Time |
17:12 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2002-12-14 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2002-12-14 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 11 | | | | | | 1) PLANS SHALL BE ROUTED TO DEPT. OF | | | BUSINESS REGULATION HOTEL & RESTURANT | | | DIVISION (954) 956-5692 PRIOR TO RE- | | | SUBMITTING TO CITY OF WPB FOR REVIEW. | | | 2) GREASE TRAP SHALL BE SIZED BY UTILITY | | | DEPT., WASTE ORD. #2938-96. PLEASE CON- | | | TACT RODNEY COMPO ENVIRONMENTAL COMPLI- | | | ANCE (561) 837-4074. | | | 3) RPZ BACKFLOW IS REQUIRED FOR WATER | | | SERVICE TO RESTURANT. MAX 4' ABOVE FLOOR | | | FOR SERVICE AND CERTIFICATION. | | | 4) SHT A100 TOILET ROOMS SHALL COMPLY | | | WITH SECTION 11-4.22. SHOW CLEAR FLOOR | | | SPACE, AND UNOBSTRUCTED 5' TURNING RAD- | | | IUS. 11-4.22.3. DOOR SHALL NOT OPEN INTO | | | THE CLEAR FLOOR SPACE OR TURNING RADIUS | | | OF ANY FIXTURE. SECTION 11-4.22.2. | | | SEC 11-4.16 AND ALL SUBSECTIONS - | | | SEC 11-4.19 AND ALL SUBSECTIONS - PLEASE | | | PROVIDE DETAILS FOR COMPLIANCE. | | | 5) SHTS P100 & P101, FLOOR SINKS ARE RE- | | | QUIRED FOR ALL INDIRECT WASTE. 802.3 | | | FLOOR DRAINS ARE NOT AN APPROVED INDIR- | | | ECT WASTE RECEPTOR. | | | 6) SHTS P100 & P101 DISHWASHER SHALL | | | DRAIN INTO THE SANITARY SYSTEM NOT THE | | | GREASE LINE PER UTILITY DEPT. | | | 7) SHTS P100P101 WATER RISER DIAGRAM. | | | WATER HAMMER ARRESTORS ARE REQUIRED AT | | | ALL QUICK CLOSING VALVES, (ICE MACHINE, | | | DISHWASHER) PER 406.9. THE LOCATION | | | SHALL BE IN AN "EFFECTIVE RANGE" NEAR | | | THE FIXTURE, NOT AT THE TOP OF THE DROP | | | IN CEILING PER PDI-WH 201 AND MANUFACT- | | | URE INSTALLATION INSTRUCTIONS. | | | 8) SHTS P100 & P101 VENT REQUIRED FOR | | | GREASE LINE AS IT ENTERS BLDG TO VENT | | | GREASE TANK. | | | 9) THE FOLLOWING COMMENTS ARE FOR THE | | | NATURAL GAS SYSTEM. INFORMATION REQUIRED | | | FOR GAS PERMIT APPLICATION. (SEPARATE | | | PERMIT REQUIRED) | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | GAS CODE. | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | FBC-2001 FUEL GAS CODE SEC. 401.8 THRU | | | 402.5.2 & TABLES 402(1) THRU 402(34). | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC 402.2. IF | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | 9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2001 | | | FUEL GAS CODE SEC. 402.2 | | | 12. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|