| 2003-01-17 00:00:00 | *******************PROVISO************* | | | | | | 1. SHOP DRAWINGS TO BE SUBMITTED FOR | | | ALLCABINETS INSTALLATION AND | | | COUNTERTOPS AT RECEPTION AREA TO SHOW | | | HEIGHT TO ADDRESS FBC 11.7.2(2). | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEADETH SMITH: BUIDING PLANS EXAMINER | | | 659-8096 EXT. 8394 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-01-17 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2002-12-12 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2002-12-12 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2002-12-12 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) FBC* 104.2.1.2PLANS SHALL STATE THE | | | FLOOR AREA, AND THE EXISTING AND | | | PROPOSED OCCUPANCY CLASSIFICATION. | | | | | | 3) FBC* 104.2.1.2AMEND THE PLANS TO | | | CLEARLY SHOW WHICH ARE EXISTING WALLS | | | AND DOORS, AND WHERE NEW OPENINGS ARE TO | | | BE FORMED IN EXISTING WALLS. | | | | | | 4) FBC* 104.2.1.2PROVIDE A CROSS- | | | SECTION THROUGH THE CONFERENCE 1 WALL TO | | | CLARIFY THE PROPOSED ARRANGEMENT FOR THE | | | "NEW INSULATED WALL" AND "3 1/2 INCH | | | WALL TRAY" IN RELATION TO THE EXISTING | | | WALL.WHAT DOES THE HEAVY BLACK LINE ON | | | THE PLAN REPRESENT? | | | | | | 5) FBC 11-7.2(2)THE RECEPTION COUNTER | | | SHALL HAVE A PORTION NOT LESS THAN 36" | | | LONG WITH A MAXIMUM HEIGHT OF 36" ABOVE | | | FLOOR LEVEL.ALTERNATIVELY AN AUXILIARY | | | COUNTER WITH A MAXIMUM HEIGHT OF 36" | | | SHALL BE PROVIDED IN CLOSE PROXIMITY TO | | | THE MAIN COUNTER. | | | | | | 6) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-03-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-21 |
Time |
09:27 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-03-21 |
Time |
09:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-01-27 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-18 |
Time |
13:27 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-01-27 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2003-01-27 00:00:00 | *********** NOTES REDLINED ******** | | | | | | 1)NOTE: PLEASE SHOW CIRCUITING ON PLANS | | | AND CORRELATE WITH SUBMITTED PANEL | | | SCHEDULES. PLEASE ALSO SUBMIT A LINE | | | DIAGRAM OF SERVICE THAT IS BEING UP- | | | -GRADED TO 200A'S. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW BEFORE ROUGH ELECTRICAL INSPECT- | | | ION IS CALLED IN. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-01-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-06 |
Time |
07:23 |
Rev Time |
50.00 |
| Received By |
dpalmer |
Date |
2003-01-06 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2003-01-06 00:00:00 | ************** UNSAT ************ | | | | | | | | | PLEASE NOTE, NOW NEW SHEETS ARE SUBMITT- | | | ED FOR REVIEW. PLEASE NOTE, THERE ARE | | | ITEMS ON NEW ELECTRICAL PLANS THAT DO | | | NOTE INDICATE WEATHER NEW OR EXISTING?? | | | PLEASE ALSO NOTE WORK ALSO APPEARS TO | | | BE SHOWN BEING DONE IN UNIT NEXT TO 223? | | | PLEASE CLARIFY. | | | | | | 1)NOTE: PLEASE SHOW LOAD CALCUALTIONS | | | PER COMM REQ`MENTS 220. PLEASE NOTE | | | ALL CONTINUOUS LOADS AT 125%. | | | | | | 2)NOTE: PLEASE SEE700-12E FOR CIRCUITING | | | OF EM/EXT LTS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-20 |
Time |
12:31 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2002-11-20 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2002-11-20 00:00:00 | **************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE NOTE PLANS NOTE 3 NEW | | | SCONCES AND ONLY 2 SHOWN. | | | | | | 2)NOTE: PLEASE ALSO SEE 700-12E FOR | | | CIRCUITING OF EM/EX LTS. | | | | | | 3)NOTE: PLEASE CLARIFY LOADS AND SIZE | | | OF EXISTING ELEC, CHANGING USE FROM | | | RESIDENTIAL TO COMM USE. PER 220 | | | | | | 4)NOTE: PLEASE CLARIFY IF NEW HC BATH | | | IS FROM AN EXISTING LOCATION? W/ EXIST | | | ELEC OR NEW ? | | | | | | 5)NOTE: PLEASE CLARIFY NEW "WORK" | | | STATIONS SHOWN ON PLANS. WILL THEY HAVE | | | ELECTRIC? | | | | | | 6)NOTE: PLEASE PROVIDE CIRCUITING ON | | | PLANS AND CORRELATE W/ A PANEL SCHEDULE. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-02-10 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2003-02-10 |
Time |
09:01 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
2003-02-10 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2003-02-10 00:00:00 | NO CHANGES FROM LAST REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-01-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-01-02 |
Time |
19:21 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-01-02 |
Time |
19:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-11-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-11-22 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-11-22 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2002-11-22 00:00:00 | 1) WRONG LIFE SAFETY CODE REFERENCED | | | ON PLANS. SHOULD READ 2000 EDITION | | | INSTEAD OF 1994 EDITION. | | | | | | 2) PLANS FAIL TO INDICATE ANY | | | INSTALLATION OF ILLUMINATED EXIT | | | LIGHTS OR EMERGENCY LIGHTS. | | | | | | 3) PLANS FAIL TO INDICATE ANY | | | INTERIOR FINISH CLASSIFICATION FOR | | | WALLS AND CEILINGS. | | | | | | 4) IT IS PRESUMED THAT THE TWO SPACES | | | WILL BE USED FOR BUSINESS PURPOSES. | | | PLEASE NOTE FIRE EXTINGUISHER LOCATIONS | | | WITHIN SPACES. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-03-18 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-18 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-18 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2003-03-18 00:00:00 | COMM BOARD #57 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-01-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-27 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-22 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2003-01-27 00:00:00 | COM BOARD#5./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-01-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-22 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-22 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2003-01-22 00:00:00 | COMM BOARD # |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-12-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-20 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-12-20 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2002-12-20 00:00:00 | | | | COM BOARD #7./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-02-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-26 |
Time |
09:16 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-02-26 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2003-02-26 00:00:00 | DUCT LAYOUT SHOWN ON PLAN SHEET A.2 - | | | RELOCATE EXISTING DUCT TO OTHER SIDE | | | OF COL/BEAM.EXTENDING DUCTWORK IN THE | | | "RECEPTION" RM. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-01-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-01-07 |
Time |
10:23 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2003-01-07 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2003-01-07 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR REVIEW | | | PLEASE PROVIDE PLANS WITH MECHANICAL | | | PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2003-03-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-22 |
Time |
15:07 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-03-22 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2003-03-22 00:00:00 | REVISION - SUBMITTAL - WATER COOLER | | | MANUF INFO - ARI-1010 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-02-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-02-04 |
Time |
08:15 |
Rev Time |
1.33 |
| Received By |
kstevens |
Date |
2003-02-03 |
Time |
18:52 |
Sent To |
|
|
| Notes |
| 2003-02-04 00:00:00 | PASSED/PROVISO | | | | | | WATER COOLER SHALL COMPLY WITH ARI-1010 | | | MANUFACTURE INFORMATION REQUIRED AT TIME | | | OF FINAL INSPECTION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-01-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-10 |
Time |
17:04 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-01-10 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2003-01-10 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A.1 WOMENS BATHROOM, PER SECTION | | | 11-4.22.2 DOORS SHALL NOT SWING INTO THE | | | CLEAR FLOOR SPACE REQUIRED FOR ANY FIX- | | | TURE. | | | 2) SHT A.1 WOMENS BATHROOM, TUB SHALL | | | COMPLY WITH SECTION 11-4.20 AND ALL SUB- | | | SECTIONS. PLEASE PROVIDE A DETAIL. | | | 3) SHT A.1 WATER COOLER SHALL COMPLY | | | WITH ARI-1010 PER SECTION 410.1. PLEASE | | | PROVIDE MANUF. INFORMATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-12-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-12-11 |
Time |
18:43 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2002-12-11 |
Time |
18:43 |
Sent To |
|
|
| Notes |
| 2002-12-11 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A.1 PER 11-4.1.6(1)(A) BOTH | | | TOILET ROOMS SHALL BE ACCESSIBLE. | | | 2) SHT A.1 PER SEC 403.2 SEPARATE FAC- | | | ILITIES ARE REQUIRED FOR EACH SEX. | | | (EXCEPTION #4 3000 SQ FT OR LESS) | | | 3) SHT A.1 PER TABLE 403.1 A DRINKING | | | FOUNTAIN IS REQUIRED. ALSO SEE SECTION | | | 410.1 | | | 4) SHT A.1 SINK IN KITCHEN SHALL COMPLY | | | WITH SECTION 11-4.24 AND ALL SUBSECTIONS | | | PLEASE PROVIDE DETAIL. | | | 5) PLEASE SHOW ALL CLEAR FLOOR SPACES | | | FOR ACCESSIBLE FIXTURES. ALSO SHOW 5' | | | TURNING RADIUS'S. | | | 6) PLEASE SUBMIT A SANITARY AND A WATER | | | RISER DIAGRAM. ON WATER RISER DIAGRAM, | | | SHOW WATER HAMMER ARRESTORS REQUIRED BY | | | SECTION 406.9. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|