Plan Review Details - Permit 02110838
Plan Review Stops For Permit 02110838
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-12-13 Cont ID  
Sent By jgomez Date 2002-12-11 Time 16:31 Rev Time 0.50
Received By btrobaug Date 2002-12-13 Time 14:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-24 Cont ID  
Sent By shernand Date 2003-04-24 Time 13:07 Rev Time 0.00
Received By shernand Date 2003-04-24 Time 13:07 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-15 Cont ID  
Sent By dpalmer Date 2002-11-15 Time 09:08 Rev Time 0.00
Received By dpalmer Date 2002-11-15 Time 09:08 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-05-06 Cont ID  
Sent By pkrauss Date 2003-05-06 Time 10:20 Rev Time 0.25
Received By pkrauss Date 2003-05-06 Time 09:59 Sent To  
Notes
2003-05-06 00:00:00MECH REV PERMIT 02110992

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-12-07 Cont ID  
Sent By shernand Date 2003-04-24 Time 13:07 Rev Time 0.33
Received By hmoser Date 2002-12-07 Time 14:09 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-12-02 Cont ID  
Sent By jleech Date 2002-12-02 Time 17:41 Rev Time 0.25
Received By jleech Date 2002-12-02 Time 17:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-12-02 Cont ID  
Sent By sgraham Date 2002-11-18 Time 13:42 Rev Time 0.33
Received By jleech Date 2002-12-02 Time 17:16 Sent To  
Notes
2002-12-02 00:00:00MISSING SHEET MP-2. NO PLUMBING RISER
 DIAGRAM.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-12-11 Cont ID  
Sent By jgomez Date 2002-12-11 Time 16:30 Rev Time 2.00
Received By jgomez Date 2002-12-11 Time 16:30 Sent To E
Notes
2002-12-11 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 2-FLOOD ZONE A8: NEED THE ELEVATION
 CERTIFICATE.
 3-2ND FLOOR FRAMING PLAN: SPECIFY
 DRAFSTOPPING LOCATION AT AREAS NOT TO
 EXCEED 500 S.F. AS REQUIRED BY SECTION
 2305.2.2 FBC 2001.
 4-SPECIFY SIZE OF ANCHOR BOLT AND WASHER
 FOR GARAGE DOOR STRUCTURAL BUCK.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 5-DETAIL S21 DOESN'T WORK FOR WOOD COL.
 P1 AT GARAGE WALL. REVISE/CLARIFY
 AS REQUIRED. SECTION 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-11-18 Cont ID  
Sent By dpalmer Date 2002-11-15 Time 09:08 Rev Time 0.25
Received By sgraham Date   Time   Sent To P
Notes
***NONE***