Plan Review Details - Permit 02110762
Plan Review Stops For Permit 02110762
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-05-27 Cont ID  
Sent By lmartine Date 2003-05-27 Time 17:11 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-04-07 Cont ID  
Sent By btrobaug Date 2003-05-14 Time 17:44 Rev Time 3.00
Received By lhatten Date 2003-04-06 Time 08:50 Sent To  
Notes
2003-04-07 00:00:00REVIEW & STAMPED PLANS 04/06/2003
 REMOVED OLD SHEETS & RESTAPLED IN ORDER
 SAVED OLD SHEETS 04/06/2003

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-12-13 Cont ID  
Sent By pkrauss Date 2003-04-01 Time 11:28 Rev Time 2.50
Received By lhatten Date 2002-12-12 Time 16:01 Sent To  
Notes
2002-12-13 00:00:00REVIEW & STAMPED PLANS 12/12/2002
 PROVISO
 1) BRING IN ADDITIONAL SETS OF ANY
 PRODUCT APPROVAL ( 2 SETS REQUIRED )

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-10-10 Cont ID  
Sent By btrobaug Date 2003-10-10 Time 12:11 Rev Time 1.00
Received By btrobaug Date 2003-10-10 Time 09:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-05-14 Cont ID  
Sent By csiegber Date 2003-10-03 Time 14:14 Rev Time 0.50
Received By btrobaug Date 2003-05-14 Time 17:17 Sent To B
Notes
2003-05-14 00:00:00TO LUIS./WRT.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-11-19 Cont ID  
Sent By shernand Date 2003-05-14 Time 15:57 Rev Time 1.00
Received By btrobaug Date 2002-11-19 Time 15:14 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-10-03 Cont ID  
Sent By csiegber Date 2003-10-03 Time 14:14 Rev Time 0.00
Received By csiegber Date 2003-10-03 Time 14:13 Sent To E
Notes
2003-10-03 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-05-14 Cont ID  
Sent By shernand Date 2003-05-14 Time 15:57 Rev Time 0.00
Received By shernand Date 2003-05-14 Time 15:57 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-25 Cont ID  
Sent By sthyng Date 2003-03-25 Time 09:58 Rev Time 0.00
Received By sthyng Date 2003-03-25 Time 09:58 Sent To P
Notes
2003-03-25 00:00:00TO PLUMBING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-19 Cont ID  
Sent By btrobaug Date 2002-11-19 Time 15:13 Rev Time 0.00
Received By btrobaug Date 2002-11-18 Time 15:13 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-04-01 Cont ID  
Sent By pkrauss Date 2003-03-31 Time 15:37 Rev Time 0.35
Received By pkrauss Date 2003-03-31 Time 15:35 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-02-03 Cont ID  
Sent By pkrauss Date 2003-02-03 Time 15:16 Rev Time 0.45
Received By pkrauss Date 2003-02-03 Time 15:11 Sent To  
Notes
2003-02-03 00:00:00DENIED:
 OUTSIDE AIR SHALL NOT BE TAKEN FROM THE
 ROOF TOP FOR A ONE OR TO FAMILY DWELLING
 AS PER 2001 FBC CHAPTER 13 SECTION
 609.1.ABC.1 #2.PLEASE REVISE
  
 PROVISO:
 MAXIMUM DEVELOPED LENGTH SHALL NOT
 EXCEED 25 FT FROM TE DRYER LOCATION TO
 THE OUTLET TERMINAL-(5 FT REDUCTION FOR
 EACH 90 DEGREE BEND & 2 1/2 FT REDUCTION
 FOR EACH 45 DEGREE BEND) 2001 FBC(M)
 504.6.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-12-04 Cont ID  
Sent By kstevens Date 2003-02-03 Time 11:35 Rev Time 0.35
Received By pkrauss Date 2002-12-04 Time 11:40 Sent To  
Notes
2002-12-04 00:00:00NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.
  
 PROVIDE ENERGY & MANUAL J CALCS.
  
 INDICATE IF EQUIPMENT IS NEW OR
 EXISTING.PROVIDE MAKE MODEL, BTU'S &
 SEER OF THE CONDENSER UNIT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 3 Status N Date 2003-03-27 Cont ID  
Sent By kstevens Date 2003-03-27 Time 12:38 Rev Time 2.00
Received By kstevens Date 2003-03-27 Time 12:37 Sent To Z
Notes
2003-03-27 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) OUTSIDE TOILET IS NOT APPROVED. THERE
 ARE HEALTH REASONS, STORM WATER MAY NOT
 ENTER FIXTURE, &TOILET FIXTURE DOES NO
 MEET WIND LOAD REQUIREMENTS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
  
 OWNER ASKED TO DELETE OUTSIDE TOILET.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-02-03 Cont ID  
Sent By sthyng Date 2003-03-25 Time 09:59 Rev Time 1.00
Received By kstevens Date 2003-02-03 Time 11:34 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-12-04 Cont ID  
Sent By btrobaug Date 2002-11-19 Time 15:54 Rev Time 0.50
Received By kstevens Date 2002-12-04 Time 10:49 Sent To M
Notes
2002-12-04 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT P-1 SANITARY RISER DIAGRAM, A
 VENT IS REQUIRED AT ISLAND SINK IN KIT-
 CHEN. (AAV IS ACCEPTABLE)
 2) SHT P-1 SANITARY RISER DIAGRAM, IS
 AN AIR ADMITTANCE VALVE BEING USED FOR
 THE VENT AT LAUNDRY TUB? IF SO PLEASE
 INDICATE ON PLANS.
 3) SHT P-2 MASTER BATH LAYOUT, MAXIMUM
 DISTANCE OF FIXTURE TRAP FROM VENT EX-
 CEEDS ALLOWABLE DESTANCE FOR SHOWER (6')
 AND TUB (8') PER TABLE 906.1
 4) ALL DEMO'ED PIPING IN SLAB SHALL BE
 INSPECTED PRIOR TO COVERING.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 2 Status N Date 2003-03-27 Cont ID  
Sent By kstevens Date 2003-03-27 Time 16:42 Rev Time 0.00
Received By kstevens Date   Time   Sent To  
Notes
2003-03-27 00:00:00DENIED, OUTDOOR CAN NOT BE BUILT IN
 THE SIDE SETBACK

Review Stop Z ZONING
Rev No 1 Status P Date 2002-11-19 Cont ID  
Sent By kstevens Date 2003-03-27 Time 13:23 Rev Time 0.25
Received By sgraham Date   Time   Sent To B
Notes
***NONE***