Plan Review Details - Permit 02110460
| Plan Review Stops For Permit 02110460 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-01-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-09 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-01-09 |
Time |
18:30 |
Sent To |
P |
|
| Notes |
| 2003-01-09 00:00:00 | TO KEN STEVEN'S DESK. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-01-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-10 |
Time |
10:31 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-01-10 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2003-01-10 00:00:00 | PASSED/PROVISO | | | | | | MANUFACTURE INSTALLATION INSTRUCTIONS | | | ARE REQUIRED AT FINAL FOR CAM SPRAY ST- | | | SERIES PRESSURE CLEANER. SECTION 301.3 | | | FOR UNLISTED APPLIANCES. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2002-12-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-09 |
Time |
18:30 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2002-12-13 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2002-12-13 00:00:00 | DENIED | | | REFERENCE: FBC-2001 FUEL GAS | | | | | | 1) GAS APPLIANCES ARE NOT APPROVED. | | | THESE ARE NOT LISTED APPLIANCES WITH AN | | | APPROVED AGENCY. THE UL LISTING ON THE | | | LANDA ENG4 IS NOT A GAS LISTING AND THE | | | CAM SPRAY HAS NOT LISTING FROM ANY TEST- | | | ING AGENCY. | | | | | | PLEASE SUBMIT MANUF INFO FOR LISTED | | | PRESSURE CLEANERS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-11-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-11-09 |
Time |
16:37 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2002-11-09 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2002-11-09 00:00:00 | DENIED | | | REFERENCE: FBC-2001 FUEL GAS | | | | | | 1) GAS SYSTEM IS AN ENGINEERED, SIGNED | | | AND SEALED SYSTEM. PLEASE SUBMIT A SIGN- | | | EN AND SEALED GAS RISER DIAGRAM. THE GAS | | | RISER DIAGRAM SUBMITTED DOES NOT MATCH | | | THE ENGINEERED RISER. | | | 2) ENGINEERED PLANS STATE THAT IT IS AN | | | "LP" SYSTEM AND APPLICATION/PLANS NOT | | | SUBMITTED STATE THAT THE SYSTEM IS USING | | | NATURAL GAS. PLEASE CLAIRFY. | | | 3) APPLICATION FOR "LP" WILL NEED AN LP | | | LICENSE. | | | 4) MANUFACTURE INFORMATION SUBMITTED IS | | | NOT READABLE, AND DOES NOT SHOW ANY | | | LISTING ON SUBMITTAL. | | | 5) PLEASE HAVE ENGINEER OF RECORD ADD- | | | RESS THESE DISCREPENCIES OF GAS TYPE AND | | | RISER DIAGRAMS AND RESUBMIT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
|