Plan Review Details - Permit 02110363
Plan Review Stops For Permit 02110363
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-11-27 Cont ID  
Sent By dpalmer Date 2002-11-27 Time 06:14 Rev Time 0.25
Received By dpalmer Date 2002-11-27 Time 06:14 Sent To M
Notes
2002-11-27 00:00:00NOTE REDLINED, WALL MISSING SECOND FLR.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-04-11 Cont ID  
Sent By shernand Date 2003-04-11 Time 08:36 Rev Time 0.00
Received By shernand Date 2003-04-11 Time 08:36 Sent To B
Notes
2003-04-11 00:00:00JGOMEZ DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-04-10 Cont ID  
Sent By shernand Date 2003-04-10 Time 16:48 Rev Time 0.00
Received By shernand Date 2003-04-10 Time 16:48 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-02-06 Cont ID  
Sent By btrobaug Date 2003-02-06 Time 11:43 Rev Time 0.02
Received By btrobaug Date 2003-02-06 Time 11:43 Sent To B
Notes
2003-02-06 00:00:00TO JULIO./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-07 Cont ID  
Sent By btrobaug Date 2002-11-07 Time 18:51 Rev Time 0.00
Received By btrobaug Date 2002-11-07 Time 18:51 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-04-12 Cont ID  
Sent By rregueir Date 2003-04-12 Time 11:34 Rev Time 0.33
Received By rregueir Date 2003-04-12 Time 11:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-03-06 Cont ID  
Sent By shernand Date 2003-04-10 Time 16:48 Rev Time 0.25
Received By rregueir Date 2003-03-06 Time 18:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-12-02 Cont ID  
Sent By dpalmer Date 2002-11-27 Time 06:15 Rev Time 0.33
Received By hmoser Date 2002-12-02 Time 18:38 Sent To R
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-11-23 Cont ID  
Sent By jleech Date 2002-11-23 Time 10:19 Rev Time 0.25
Received By jleech Date 2002-11-23 Time 10:19 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2003-04-15 Cont ID  
Sent By jgomez Date 2003-04-15 Time 13:07 Rev Time 0.50
Received By jgomez Date 2003-04-15 Time 13:07 Sent To  
Notes
2003-04-15 00:00:00APPROVED REVISION FOR TOP OF BOND BEAM
 ELEVATION CHANGE AT ZERO LOT LINE WALL.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2003-03-10 Cont ID  
Sent By jgomez Date 2003-03-10 Time 14:23 Rev Time 0.50
Received By jgomez Date 2003-03-10 Time 14:23 Sent To  
Notes
2003-03-10 00:00:00REVISION CHECKLIST:
 1-ARCHITECT NEEDS TO REVIEW ENGINEERING
 CALCULATIONS AND SPECS AND REVISE THE
 DIAPHRAGM SCHEDULE AS REQUIRED.
 2-SHEET A-3: REVISE RIGHT ELEVATION TO
 MATCH BUILDING SECTION A/A-3. TOP OF
 BB WAS RAISED TO AVOID 1HR. FIRE RATED
 ASSEMBLY AT TRUSS HEEL @ ZERO LOT LINE
 WALL. SEE PLANS FOR COMMENTS.
 ALSO, REVISE BEAM HEIGHT SHOW ON OTHER
 ELEVATIONS AND ROOF FRAMING PLAN.
 3-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT AS
 REQUESTED ON PROVISO DATED 12-15-02.
 4-PROVIDE COMPLETE INFORMATION ON DETAIL
 41/S1. NEED COMPLETE SIZE OF ANCHOR &
 WASHER. SEC. 104.2.1.2 CITY AMENDMENTS
 5-SHEET S-2: DETAIL 8/S-2 WAS KEYED
 INCORRECTLY. SEE PLAN AND REVISE AS
 REQUIRED.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-12-05 Cont ID  
Sent By hmoser Date 2002-12-02 Time 18:38 Rev Time 2.00
Received By jgomez Date 2002-12-05 Time 15:02 Sent To  
Notes
2002-12-05 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-ARCHITECT TO REVISE DETAIL FOR ONE HR
 FIRE RATED WALL ASSEMBLY AT ZERO LOT
 LINE. TABLE REFERENCED ON DETAIL 11/S3
 IS FOR CONCRETE WALL ASSEMBLY, NOT FOR
 WOOD CONSTRUCTION. SEE SECTION 709.6
 FBC FOR WOOD ASSEMBLIES AND PROVIDE
 COMPLETE DETAIL SHOWING ASSEMBLY FOR
 BOTH SIDES INTERIOR AND EXTERIOR
 EXPOSED TO FIRE AS REQUIRED BY TABLE
 600 FBC 2001.
 2-ARCHITECT TO REVISE THE DIAPHRAGM
 SCHEDULE TO MATCH ENGINEERING ANALYSIS
 AND SPECIFICATIONS.
 3-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 4-PROVIDE COMPLETE INFORMATION ON DETAIL
 41/S1. NEED ANCHOR SIZE AND WASHER.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-12-05 Cont ID  
Sent By btrobaug Date 2002-11-07 Time 18:51 Rev Time 0.00
Received By jgomez Date   Time   Sent To  
Notes
2002-12-05 00:00:00APPROVED BY SHIRLEY GRAHAM ON 11-8-02
 SEE SURVEY.