Plan Review Details - Permit 02110242
Plan Review Stops For Permit 02110242
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-04-01 Cont ID  
Sent By hpiskura Date 2003-04-01 Time 14:38 Rev Time 0.00
Received By hpiskura Date 2003-04-01 Time 14:38 Sent To  
Notes
2003-04-01 00:00:00REVISIONS DATED 1/30/03 A101 & A102

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-01-14 Cont ID  
Sent By hpiskura Date 2003-01-14 Time 14:56 Rev Time 0.00
Received By hpiskura Date 2003-01-14 Time 14:38 Sent To  
Notes
2003-01-14 00:00:00NEEDS NOC

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-11-13 Cont ID  
Sent By jwitmer Date 2002-11-13 Time 07:08 Rev Time 1.75
Received By jwitmer Date 2002-11-13 Time 07:08 Sent To  
Notes
2002-11-13 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02110242
 ADD: 505 S FLAGLER/ 1500
 CONT: ANDERSON MOORE
 TEL: (561)627-4744
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) 412.6.1 HISE RISE, ALL ELEVATORS ON
 ALL FLOORS SHALL OPEN INTO ELEVATOR LOB-
 BIES WHICH ARE SEPERATED FROM THE REMAIN
 DER OF THE BUILDING BY ONE HOUR FIRE
 RESISTANT CONSTRUCTION WITH 20-MINUTE
 OPENING PROTECTIVES.
  
 2) OPENINGS IN ELEVATOR LOBBY SHALL BE
 LIMITED TO THOSE FOR ACCESS TO THE
 ELEVATOR AND FOR EGRESSTO THE BUILDING.
 ALL ROOMS AND ENCLOSURES SHALL HAVE AT
 LEAST ONE REQUIRED EXIT ACCESSIBLE WITH-
 OUT TRAVEL THROUGH THE ELEVATOR LOBBY.
 EXIT STAIWAYS, CHUTES,JANITORS CLOSETS,
 GUEST ROOMS, SERVICE ROOMS, ETC SHALL
 NOT OPEN INTO THE ELEVATOR LOBBY.
 SEE HVAC ROOM, ELEC ROOM, STAIRS.
  
 3) 412.6.3 EACH ELEVATOR LOBBY SHALL BE
 PROVIDED WITH APPROVED SMOKE DETECTOR
 LOCATED ON THE ELEVATOR CEILING.
  
 4)704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 5)705.7.1 JOINTS INSTALLED IN OR BE-
 TWEEN FIRE RESISTANT WALLS, FIRE RESIS-
 TANT FLOORS OR FLOOR/ CEILING ASSEMBLIES
 AND FIRE RESISTANT ROOFS OR ROOF/ CEIL-
 ING ASSEMBLIES SHALL BE PROTECTED BY AN
 APPROVED FIRE RESISTANT JOINT SYSTEM
 DESIGNED TO RESIST THE PASSAGE OF FIRE
 FOR A PERIOD NOT LESS THAN THE RE-
 QUIRED FIRE RESISTANCE RATING OF THE
 WALL, FLOOR OR FLOOR IN OR BETWEEN
 WHICH IT IS INSTALLED.
  
 6) TABLE 803.3 MINIMUM INTERIOR FINISH
 CLASSIFICATION; PROVIDE INFORMATION
 BASED ON INTERIOR FINISH REQUIREMENTS
 BASED ON OCCUPANCY
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-04-07 Cont ID  
Sent By dpalmer Date 2003-04-07 Time 05:54 Rev Time 0.25
Received By dpalmer Date 2003-04-07 Time 05:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-11-14 Cont ID  
Sent By dpalmer Date 2002-11-14 Time 12:04 Rev Time 1.00
Received By dpalmer Date 2002-11-14 Time 12:04 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-01-03 Cont ID  
Sent By mcarsill Date 2003-01-03 Time 16:10 Rev Time 0.00
Received By mcarsill Date 2003-01-03 Time 16:10 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-11-22 Cont ID  
Sent By mcarsill Date 2002-11-22 Time 13:04 Rev Time 0.00
Received By mcarsill Date 2002-11-22 Time 13:04 Sent To  
Notes
2002-11-22 00:00:001) PLEASE SEE BUILDING PLAN REVIEW
 COMMENTS. THIS OFFICE CONCURS WITH
 THE BUILDING PLAN REVIEWER COMMENTS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-04-08 Cont ID  
Sent By shernand Date 2003-04-08 Time 16:03 Rev Time 0.00
Received By shernand Date 2003-04-08 Time 16:03 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-26 Cont ID  
Sent By sthyng Date 2003-03-26 Time 15:21 Rev Time 0.00
Received By sthyng Date 2003-03-26 Time 15:21 Sent To  
Notes
2003-03-26 00:00:00COMM BOARD #25

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-23 Cont ID  
Sent By dpalmer Date 2002-12-23 Time 10:18 Rev Time 0.00
Received By dpalmer Date 2002-12-23 Time 10:18 Sent To  
Notes
2002-12-23 00:00:00TO COMM BOARD #28

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-04-14 Cont ID  
Sent By pkrauss Date 2003-04-14 Time 14:57 Rev Time 0.30
Received By pkrauss Date 2003-04-14 Time 14:57 Sent To  
Notes
2003-04-14 00:00:00REVISION 3 MECHANICAL

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-04-12 Cont ID  
Sent By hmoser Date 2003-04-12 Time 08:19 Rev Time 0.50
Received By hmoser Date 2003-04-12 Time 08:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-11-27 Cont ID  
Sent By shernand Date 2003-04-08 Time 16:03 Rev Time 0.50
Received By pkrauss Date 2002-11-27 Time 07:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-04-12 Cont ID  
Sent By kstevens Date 2003-04-12 Time 07:30 Rev Time 0.50
Received By kstevens Date 2003-04-12 Time 07:30 Sent To  
Notes
2003-04-12 00:00:00REVISION OK - CHANGE SINGLE DF TO DOUBLE

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-01-11 Cont ID  
Sent By kstevens Date 2003-01-11 Time 08:30 Rev Time 0.25
Received By kstevens Date 2003-01-11 Time 08:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-12-02 Cont ID  
Sent By kstevens Date 2002-12-02 Time 13:23 Rev Time 0.50
Received By kstevens Date 2002-12-02 Time 13:23 Sent To  
Notes
2002-12-02 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) SHT A208 BREAKROOM SINK SHALL COMPLY
 WITH 1104.24 AND ALL SUBSECTIONS. PLEASE
 SUBMIT DETAIL FOR COUNTER HEIGTHT 4.24.2
 KNEE CLEARANCE 4.24.3, CLEAR FLOOR SPACE
 4.24.5, ECT.
 2) TABLE 403.1 MINIMUM FACILITIES CALLS
 FOR DRINKING FOUNTAIN. PLEASE INDICATE
 IF THERE IS DRINKING FOUNTAINS IN COMMON
 AREA. IF NOT A DRINKING FOUNTAIN OR
 WATER COOLER SHALL BE REQUIRED. SECTION
 410.1 (ARI-1010 COMPLIANT)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377