Plan Review Details - Permit 02110226
Plan Review Stops For Permit 02110226
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-12-10 Cont ID  
Sent By hmoser Date 2002-12-09 Time 18:45 Rev Time 0.25
Received By dpalmer Date 2002-12-10 Time 06:28 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-04-11 Cont ID  
Sent By shernand Date 2003-04-11 Time 10:50 Rev Time 0.00
Received By shernand Date 2003-04-11 Time 10:50 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-04-11 Cont ID  
Sent By shernand Date 2003-04-11 Time 08:37 Rev Time 0.00
Received By shernand Date 2003-04-11 Time 08:37 Sent To B
Notes
2003-04-11 00:00:00JGOMEZ DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-02-06 Cont ID  
Sent By btrobaug Date 2003-02-06 Time 11:42 Rev Time 0.02
Received By btrobaug Date 2003-02-06 Time 11:41 Sent To B
Notes
2003-02-06 00:00:00TO JULIO./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-05 Cont ID  
Sent By btrobaug Date 2002-11-05 Time 14:11 Rev Time 0.00
Received By btrobaug Date 2002-11-05 Time 14:11 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-04-19 Cont ID  
Sent By rregueir Date 2003-04-19 Time 15:16 Rev Time 0.33
Received By rregueir Date 2003-04-19 Time 15:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-03-11 Cont ID  
Sent By shernand Date 2003-04-11 Time 10:50 Rev Time 0.33
Received By rregueir Date 2003-03-11 Time 16:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-12-09 Cont ID  
Sent By hmoser Date 2002-12-09 Time 18:44 Rev Time 0.33
Received By hmoser Date 2002-12-09 Time 18:44 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-12-02 Cont ID  
Sent By sgraham Date 2002-11-18 Time 13:23 Rev Time 0.25
Received By jleech Date 2002-12-02 Time 18:47 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2003-04-15 Cont ID  
Sent By jgomez Date 2003-04-15 Time 09:51 Rev Time 5.00
Received By jgomez Date 2003-04-15 Time 09:51 Sent To  
Notes
2003-04-15 00:00:00REVISION FOR TOP OF BEAM ELEVATION AT
 ZERO LOT LINE WALL APPROVED.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2003-03-10 Cont ID  
Sent By jgomez Date 2003-03-07 Time 17:54 Rev Time 0.50
Received By jgomez Date 2003-03-07 Time 17:53 Sent To  
Notes
2003-03-07 00:00:00SUBMITTAL CHECKLIST:
 1-ARCHITECT NEEDS TO REVIEW ENGINEERING
 CALCULATIONS AND REVISE THE DIAPHRAGM
 SCHEDULE AS REQUIRED.
 2-SHEET A-3: REVISE RIGHT ELEVATION TO
 MATCH BUILDING SECTION A/A3.TOP OF
 BB WAS RAISED TO AVOID ONE HR ASSEMBLY
 AT TRUSS HEEL AREA AT ZERO LOT LINE
 WALL.
 3-SHEET S-2: DETAIL 8/S2 WAS INCORRECTLY
 KEYED. SEE 2ND FLOOR FRAMING PLAN AND
 REVISE AS REQUIRED.
 4-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT AS
 REQUESTED ON PROVISO DATED 12-10-02.
 5-PROVIDE COMPLETE INFORMATION ON DETAIL
 41/S1. NEED COMPLETE ANCHOR SIZE AND
 WASHER. SEC. 104.2.1.2 CITY AMENDMENTS
 TO FBC 2001.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-12-10 Cont ID  
Sent By jgomez Date 2002-12-10 Time 10:58 Rev Time 2.00
Received By jgomez Date 2002-12-10 Time 10:58 Sent To  
Notes
2002-12-10 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-ARCHITECT TO REVISE DETAIL FOR ONE HR
 WALL ASSEMBLY AT ZERO LOT LINE.
 TABLE REFERENCED ON DETAIL 11/S3 IS
 FOR CONCRETE WALL ASSEMBLIES, NO WOOD.
 SEE SECTION 709.6 FOR WOOD ASSEMBLIES
 AND PROVIDE COMPLETE DETAIL FOR ONE HR
 ASSEMBLY WITH PROTECTION FROM EXTERIOR
 AND INTERIOR AS REQUIRED BY TABLE 600
 FBC 2001.
 2-ARCHITECT TO REVISE THE DIAPHRAGM
 SCHEDULE TO MATCH ENGINEERING ANALYSIS
 AND SPECIFICATIONS.
 3-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 4-PROVIDE COMPLETE INFORMATION ON DETAIL
 41/S1. NEED ANCHOR SIZE AND WASHER.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-11-18 Cont ID  
Sent By btrobaug Date 2002-11-05 Time 14:11 Rev Time 0.25
Received By sgraham Date   Time   Sent To P
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy