| Plan Review Stops For Permit 02110220 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-06-20 |
Time |
18:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-06-20 |
Time |
18:08 |
Sent To |
|
|
| Notes |
| 2006-06-20 00:00:00 | REVISED A2, A3, A5 DATED 6/14/06 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2006-06-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-06-07 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-06-07 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2006-06-07 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)THE PERMIT WAS ISSUED WITH A | | | PROVISO TO REVISE A3 (MANEUVERING | | | CLEARANCE FOR THE DOOR AT OFFICE #4 TO | | | COMPLY WITH FBC11 FIGURE 25).THE PLAN | | | AS DRAWN IS NOT CODE COMPLIANT.WAS | | | THIS CLOSET/DOOR AREA BUILT AS DRAWN? | | | PLEASE ADVISE AS TO FIELD CONDITIONS AND | | | REVISE PLAN AS REQUIRED ON 7/20/2004. | | | | | | PROVISOS ARE ISSUED AS A COURTESY TO | | | AVOID DELAYS IN PERMITTING (THE OTHER | | | OPTION IS TO FAIL THE PLAN, HAVE THE | | | DESIGNER CHANGE THE PLAN, AND RESUBMIT). | | | THIS PROVISO IS WRITTEN UNDER THE BLOCK | | | STAMP ON THE COVER SHEET, REDLINED ON | | | A3, WAS DISCUSSED WITH THE CONTRACTOR, | | | AND WAS ENTERED IN THE PLAN REVIEW | | | NOTES.IN THE FUTURE, PLEASE ADDRESS | | | PROVISOS IN A TIMELY MANNER TO AVOID | | | DELAYS IN THE FIELD. | | | | | | 2.)THE PLANS APPEAR CODE COMPLIANT. | | | HOWEVER, REVISE THE AFFECTED SHEETS. | | | SKETCHES ARE TYPICALLY USED TO PROVIDE | | | CLARIFICATION OR ADDITIONAL DETAILS NOT | | | INCLUDED ON THE PLANS.YOU ARE CHANGING | | | THE DETAILS ON THE PLAN.TO AVOID | | | CONFUSION, AND FOR OUR RECORD KEEPING | | | PURPOSES, PLEASE CHANGE THE AFFECTED | | | SHEETS. | | | | | | WHEN SUBMITTING THE REVISION, YOU WILL | | | BE CHARGED A REVISION FEE OF $60 FOR | | | SHEET A3.AS THESE DETAILS HAVE ALREADY | | | BEEN REVIEWED, NO FEE WILL BE CHARGED | | | FOR INCORPORATING THE DETAILS INTO THE | | | SHEETS (UNLESS OTHER CHANGES ARE MADE). | | | PLEASE ADVISE THE FRONT COUNTER STAFF | | | (BY SHOWING THIS CORRECTION LIST) OR | | | CONTACT ME. PROVIDE THE 8 1/2X11 | | | SKETCHES FOR REFERENCE WHEN | | | RESUBMITTING. | | | | | | 3.) THE ARCHITECT'S SKETCHES LACK THE | | | PRINTED NAME OF THE PERSON SEALING THE | | | DOCUMENT, FAC61G1-16. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2004-09-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-09-21 |
Time |
08:35 |
Rev Time |
1.50 |
| Received By |
shill |
Date |
2004-09-21 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2004-09-21 00:00:00 | ****CORRECTIONS**** | | | FAX DATED 8/30/2004 PREPARED BY SLA | | | ARCHITECTS AND PLANNERS INC. | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | THIS LETTER SERVES AS A CURSORY REVIEW | | | OF THE SKETCH AND LETTER SUBMITTED | | | REGARDING THE USE OF A PLATFORM LIFT | | | RATHER THAN AN ELEVATOR.ONLY FBC2001 | | | COMPLIANCE WAS TAKEN INTO CONSIDERATION; | | | FOR A MORE COMPLETE REVIEW INCLUDING | | | OTHER TRADES, INCLUDING FIRE, PLEASE | | | SUBMIT AS A REVISION. | | | | | | VERTICAL ACCESSIBILITY IS REQUIRED FBC | | | 11-4.1.3.THE EXCEPTIONS IN 11-4.1.3(5) | | | DO NOT APPEAR TO APPLY TO THIS JOB. | | | RELIEF FROM THIS REQUIREMENT MAY BE | | | REQUESTED FROM THE BUILDING OFFICIAL | | | IN WRITING; PLEASE ADDRESS TO NEIL K. | | | MELICK. | | | | | | FIRE RESISTANCE OF THE PROPOSED LIFT | | | WOULD BE DETERMINED BY FBC704.2.1.2 AND | | | FBC TABLE 705.1.2.YOUR APPROVED PLAN | | | INDICATES A 1 HR FLOOR/CEILING ASSEMBLY | | | RATING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-07-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-07-20 |
Time |
08:05 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-07-20 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2004-07-20 00:00:00 | ***PROVISO*** | | | REVISE SHEET A3 AS NOTED ON PLAN - | | | DOOR FOR OFFICE #4 IS TO COMPLY WITH | | | FBC11 FIGURE 25 | | | SUBMITTED ON 8 1/2 X 11 - OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-15 |
Time |
09:14 |
Rev Time |
2.50 |
| Received By |
shill |
Date |
2004-06-22 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2004-06-23 00:00:00 | ***PROVISO*** | | | ***IMPACT FEES MUST BE PAID BEFORE | | | PERMITTING**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE IMPACT FEE STAMP DOES NOT | | | REFLECT THE ADDITIONAL SQUARE FOOTAGE. | | | PLEASE SEE WILLIE SWOPE, PALM BEACH | | | COUNTY IMPACT FEES, 233-5025.THIS | | | APPEARS TO INVOLVE A CHANGE OF USE | | | (WAREHOUSE TO BUSINESS) AS WELL AS AN | | | INCREASE IN SQUARE FOOTAGE (NEW 2ND | | | FLOOR AREA).THE IMPACT FEE STAMP | | | SHOULD REFLECT THIS EVEN IF NO FEES ARE | | | DUE. | | | | | | 2.)SIGN THE OWNER/AGENT LINE OF THE | | | ENERGY CALC. | | | | | | 3.)REVISE SHEET A3. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-04-07 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2004-04-07 |
Time |
06:45 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2004-04-07 |
Time |
06:45 |
Sent To |
FIRE |
|
| Notes |
| 2004-04-07 00:00:00 | PLAN REVIEW NOT A PERMIT APPLICATION. | | | THIRD PLAN REVIEW. PLANS BY SLA | | | ARCHITECTS DATED 1/29/04. | | | | | | DETAILS 2/A1 AND 3/A1 DEPICT BEVELED | | | WINDOW BUCKS.SEE FBC 1707.4.4.2 | | | REGARDING FULL SUPPORT. | | | | | | SHEET A2.PROVIDE A DETAIL FOR THE | | | WINDOWS TO BE CUT IN TO HAVE HEADERS OR | | | LINTELS.SEE FBC 104.2 AS AMENDED | | | | | | SHEET A3, THE 42" HIGH STAIR GUARD RAIL. | | | THE BOTTOM RAIL MUST BE 2" OR LESS ABOVE | | | THE FLOOR.SEE FBC 1015.3. | | | | | | SHEET A3 SHOWS A 45 MIN RATED DOOR ON | | | THE FIRST FLOOR FOR THE STAIR SHAFT.A | | | ONE HOUR RATING IS REQUIRED AND THE | | | SHAFT WALL CONTINUOUS.SEE FBC | | | 704.2.1.2 AND FBC TABLE 705.1.2. | | | | | | THE A/C PLAN STILL SHOWS A DUCT | | | PENETRATING THE EXIT STAIR ENCLOSURE. | | | SEE FBC 1006.1.3.1 AND NFPA 101 | | | 7.1.3.2.1 (E).THE REFERENCE TO DUCTS | | | IS FOR STAIR PRESSURIZATION NOT AIR | | | CONDITIONING. | | | | | | THE A/C SHEET IS NOT SEALED BY THE | | | ARCHITECT. | | | | | | SHEET A3 CONTAINS A NOTE REFERENCING | | | ACCESSIBILITY.THE 11.1.6 (I) (F) | | | SECTION CITED IS NOT FOUND IN THE FBC. | | | PLEASE SEE FBC 11-4.1.3 (5) AND FBC | | | 11-4.1.6 (1), VERTICAL ACCESIBILITY IS | | | REQUIRED. | | | | | | THE TRACO WINDOW NOA HAS ILLEGIBLE | | | DRAWINGS. | | | | | | THE PLANS DO NOT SHOW THE PRESSURES FOR | | | THE WINDOW DESIGN.SEE FBC 1606.1.7 #5. | | | | | | SEE PREVIOUS NOTES REGARDING IMPACT | | | FEES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-10-22 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-10-22 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2003-10-22 00:00:00 | PLAN REVIEW ONLY NOT A PERMIT | | | APPLICATION.PLANS PREPARED BY SLA | | | ARCHITECTS DATED 7/16/03. | | | | | | THE NEW WINDOWS MUST COMPLY WITH THE | | | FBC1606.1.4 FOR HURRICANE MISSILE | | | IMPACT PROTECTION.AT TIME OF PERMIT | | | APPLICATIONPROVIDE NOTICE OF ACCEPTANCE | | | AND/OR TEST REPORTS. | | | | | | INCLUDE FLORIDA ENERGY CODE CALCULATIONS | | | WITH THE PERMIT APPLICATION.SEE FBC | | | 13-101.1. | | | | | | THE MIXED OCCUPANCY RATING BETWEEN THE | | | OFFICE AND WAREHOUSE AREA IS REQUIRED | | | TO BE A MINIMUM OF 2 HOURS NOT THE 1 | | | HOUR SHOWN.SEE FBC 704.1 FOR S2 AND B | | | OCCUPANCIES.THE U906 MASONRY DESIGN | | | USES ONLY UL LISTED MANUFACTURED BLOCKS | | | THAT ARE NOT COMMON IN THIS AREA.THE | | | DESIGN IS ACCEPTABLE BUT THE BLOCK | | | VENDORS MUST PROVIDE THEIR LISTING. | | | | | | SHOW THE METHOD(S) FOR PROTECTION OF THE | | | PENETRATIONS OF THE FIRE RATED | | | ASSEMBLIES.SEE FBC 705. | | | | | | THE A/C DUCT PENETRATING THE STAIR SHAFT | | | IS NOT ALLOWED BY FBC 1006.1.3.1. | | | | | | THE NEW STAIRS AS SHOWN ON SHEET A3 DO | | | NOT DISCHARGE DIRECTLY TO THE OUTSIDE. | | | SEE FBC 1006.1.3 AS REGARDS THE HC LIFT | | | AND DOOR RATING. | | | | | | SHOW EXISTING OR PROVIDE HANDICAP | | | ACCESS FROM THE BUILDING EXTERIOR. | | | | | | SECTION D/A5 SHOWS A RISER HEIGHT | | | GREATER THAN THE 7" PERMITTED BY FBC | | | 1007.3.1.REVIEW THE HEIGHT DIMENSIONS | | | SHOWN.ALSO, SEE FBC 1007.3.3 FOR | | | TOLERANCES.1/64" IS NOT A COMMON | | | FIELD DIMENSION. | | | | | | THE FLOOR CEILING DESIGN UL G 236 DOES | | | NOT PROVIDE FOR PENETRATIONS OR | | | INTERSTIAL MECHANICAL EQUIPMENT. | | | PLEASE REVISE AS NECESSARY AT PERMIT | | | TIME. | | | | | | THE CHANGE IN USE AND ADDITIONAL FLOOR | | | AREA TO BE ADDED IS SUBJECT TO IMPACT | | | FEES BY THE COUNTY.BEFORE A PERMIT TO | | | CONSTRUCT MAY BE ISSUED THE PERMIT | | | PLANS MUST BE STAMPED BY THAT OFFICE | | | AND A COPY OF THE PAID RECEIPT ATTACHED | | | TO THE PERMIT APPLICATION. CALL | | | 561-233-5025 FOR MORE INFORMATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-12-02 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-12-02 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-12-02 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2002-12-02 00:00:00 | THE MINIMUM CONSTRUCTION TYPE FOR THIS | | | BULDING IS TYPE V 1 HOUR PROTECTED OR | | | TYPE V FIRE SPRINKLERED.PLEASE NOTE | | | THE PARTICULAR EXISTING CONDITION AT | | | TIME OF PERMIT APPLICATION OR METHOD OF | | | COMPLIANCE TO BE ESTABLISHED. | | | | | | THE PERMIT PLANS MUST HAVE THE MINIMUM | | | DESIGN INFORMATION CONTAINED IN FBC | | | 104. 3.1.1 AND FBC 1606.1.7. | | | | | | SHEET A1 DOES NOT SHOW THE SPACING OF | | | THE 4X4 STEEL COLUMNS. | | | | | | SECTIONS TAKEN AS B AND C ON SHEET A1 | | | ARE NOT INCLUDED WITH THE PLANS. | | | | | | SHOW A DETAIL FOR THE INSTALLATION OF | | | THE NEW PAD FOOTINGS IN RELATION TO THE | | | EXISTING WALL FOOTINGS, PARTICLARLY THE | | | ONES THAT WILL BE ECCENTRICALLY LOADED. | | | INCLUDE THE HEIGHT OF THE TOP OF THE | | | PADS RELATIVE TO THE FINISH FLOOR. | | | | | | SHEET A2, SHOW A DETAIL FOR THE | | | TRANSITION OF THE W12X27 BEAM TO THE | | | 8X8X1 ANGLE. ALSO, THE STEEL COLUMN | | | DETAIL DOES NOT PROVIDE FOR ATTACHMENT | | | TO THE W12X27 BEAM. | | | | | | SHEET A3.SHOW HOW HANDICAP VERTICAL | | | ACCESSIBILITY WILL BE ACCOMPLISHED. | | | SEE FBC 11-4.1.6 (1) (F) | | | | | | SHOW A CONSTRUCTION DETAIL FOR THE | | | INTERIOR STAIRS. | | | | | | SHOW ALL OF THE STRUCTURAL DESIGN LOADS | | | ASSUMED, IE FLOOR, STAIRS, HAND AND | | | GUARD RAILS. | | | | | | PROVIDE A BEARING CONNECTION DETAIL FOR | | | THE BAR JOISTS. | | | | | | SECTION D/3.SHOW THE REINFORCING | | | DETAIL FOR THE CANTILEVERED LANDING. | | | | | | SHOW HOW THE EXTERIOR GLAZING WILL | | | RESIST HURRICANE MISSILE IMPACT.SEE | | | FBC 1606.1.4 | | | | | | THE INTERIOR STAIRS ARE REQUIRED BY FBC | | | 1006.1.1 TO BE ENCLOSED WITH FIRE RATED | | | CONSTRUCTION AND TO PROVIDE A PROTECTED | | | PATH OF EGRESS TO THE EXTERIOR OF THE | | | BUILDING AS PROVIDED FOR IN FBC 1010. | | | | | | THE EXTERIOR STAIRS MUST MEET ALL OF THE | | | REQUIREMENTS OF FBC 1006.2. | | | | | | SHOW THE FLOOR TO CEILING HEIGHTS OF THE | | | FIRST AND SECOND FLOORS. | | | | | | WHAT IS THE NATURE AND QUANTITY OF THE | | | COMMODITIES TO BE STORED IN THIS SPACE? | | | | | | THE ADDITIONAL BUILDING AREA TO BE | | | ADDED IS SUBJECT TO IMPACT FEES | | | COLLECTED BY THE COUNTY.BEFORE A | | | PERMIT TO CONSTRUCT MAY BE ISSUED | | | IMPACT FEES MUST BE PAID TO THE COUNTY, | | | THE PERMIT PLANS STAMPED BY THAT OFFICE | | | AND A COPY OF THE PAID RECEIPT ATTACHED | | | TO THE PERMIT APPLICATION.CALL | | | 561-233-5025 FOR MORE INFORMATION. | | | | | | ALL PLANS SUBMITTED FOR PUBLIC RECORD, | | | INCLUDING THE SURVEY/SITE PLAN, MUST BE | | | SIGNED AND SEALED BY THE DESIGNER OF | | | RECORD.SEE FBC 104.2.2. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-17 |
Time |
19:36 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-06-17 |
Time |
19:30 |
Sent To |
|
|
| Notes |
| 2004-06-17 00:00:00 | NEW ELECTRICAL SHEETS. | | | | | | ** REDLINED ** | | | INSPECTOR TO VERIFRY EXSITING GROUNDING | | | ELECTRODE SYSTEM. 250.50 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-03-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-23 |
Time |
15:20 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-03-23 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-14 |
Time |
18:01 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-10-14 |
Time |
18:01 |
Sent To |
|
|
| Notes |
| 2003-10-14 00:00:00 | **************** UNSAT ************* | | | | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH THE SUBMITTED | | | PANEL SCHEDULE. 215.5 | | | PLEASE SEE 700.12E FOR CIRCUITING OF | | | EM/ EXT LTS. | | | | | | 2)NOTE: PLEASE SEE THAT WE ARE NOW | | | UNDER THE 2002 NEC. 7/1/03 | | | | | | 3)NOTE: PLEASE SEE THAT LOAD ON SERVICE | | | EXCEEDS RATING OF EXISTING 200A SERVICE. | | | PLEASE INCREASE SERVICE SIZE AND | | | CONDUCTOR SIZES. 310.16/240.6 ETC. | | | | | | 4)NOTE: PLEASE ADJUST GROUNDING ELEC- | | | -TRODE CONDUCTOR PER 250.66 | | | | | | 5)NOTE: PLEASE SEE THAT MAX OCP FOR | | | 3500W OF WATER HEATER IS 150% OF LOAD. | | | MIN OCP IS 125%. PLEASE ADJUST THE 2P30A | | | SHOWN. | | | | | | 6)NOTE: PLEASE SEE PLANS, PLANS SHOW | | | TWO PANELS? RISER SHOWS ONLY ONE.? | | | PLEASE CLARIFY? | | | | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER | | | REVIEWERS THAT MAY HAVE AN AFFECT ON | | | ELECTRICAL PLANS. | | | | | | PLEASE REMOVE OLD/VOIDED SHEETS AND | | | INSERT NEW SHEETS INTO TWO COMPLETE SETS | | | FOR REVIEWING AND STAMPING. | | | ONE SET OF OLD SHEETS MAYBE SUBMITTED | | | FOR VERIFICATION. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-14 |
Time |
13:03 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2002-11-14 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2002-11-14 00:00:00 | ************ UNSAT ************* | | | | | | 1)NOTE: PLEASE NOTE, NO ELECTRICAL WAS | | | SUBMITTED FOR REVIEW. EXITS LTS/ EGRESS | | | LTS AND EMERGENCY LTS TO MEET THE MIN. | | | | | | PLEASE SUIBMIT THE ABOVE INFORMATION AND | | | COMPLETE SCOPE OF ELECTRICAL WORK. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2004-06-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-06-18 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-06-18 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2004-06-18 00:00:00 | 1) NO ITEMS ALLOWED WITHIN STAIRWELL | | | EXCEPT CODE ALLOWED ONES. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2004-04-08 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2004-04-07 |
Time |
18:34 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-04-08 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2004-04-08 00:00:00 | 1) NO MECHANICAL EQUIPMENT IS ALLOWED | | | IN A STAIRWAY UNLESS IT IS FOR STAIRWAY | | | PRESSURIZATION EQUIPMENT NEEDED FOR THE | | | STAIR. | | | | | | 2) THE STAIR HAS A 60 MINUTE DOOR AND | | | A 45 MINUTE DOOR LOCATED AT DIFFERENT | | | ELEVATIONS. | | | | | | 3) PLEASE SEE BUILDING PLAN | | | REVIEWER NOTES ON RECENT EXAM ON PLANS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-10-17 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-10-17 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-10-17 |
Time |
16:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-11-15 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-11-15 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-11-15 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2002-11-15 00:00:00 | 1) THE BOUNDARY SURVEY IS DIFFICULT TO | | | READ. | | | | | | 2) PLANS FAILED TO DISPLAY ANY | | | EMERGENCY LIGHTS OR EXIT SIGNS. | | | | | | 3) PLEASE PROVIDE PRESCRIPTIVE CODE | | | REQUIREMENTS FOR NEW HANDRAILS. | | | | | | 4) PLEASE INDICATE INTERIOR FINISH | | | INFORMATION FOR WALLS AND CEILINGS. | | | | | | 5) PLEASE INDICATE ANY OTHER FIRE | | | SAFETY EQUIPMENT OR DEVICES. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-19 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-19 |
Time |
14:59 |
Sent To |
B |
|
| Notes |
| 2006-06-19 00:00:00 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-05-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-30 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-30 |
Time |
15:13 |
Sent To |
B |
|
| Notes |
| 2006-05-30 00:00:00 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-07-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-15 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-15 |
Time |
09:14 |
Sent To |
B |
|
| Notes |
| 2004-07-15 00:00:00 | TO SH DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-06-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-16 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-16 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2004-06-16 00:00:00 | TO COMM BD#3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-03-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-08 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-08 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2004-03-08 00:00:00 | TO COMM BD#62 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-10-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-10 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-10 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2003-10-10 00:00:00 | TO COMM BD#30 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-05 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-05 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2002-11-05 00:00:00 | TO COMM BOARD # 20./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-06-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-24 |
Time |
07:17 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-06-24 |
Time |
07:17 |
Sent To |
|
|
| Notes |
| 2004-06-24 00:00:00 | PROVISO: | | | PLEASE NOTE HVAC PLANS SUBMITTED ARE RED | | | LINED BY THE A/C CONTRACTOR.FUTURE | | | SUBMITTALS OR REVISIONS, PLEASE REFLECT | | | THE DELETION OF DUCT PENETRATION THROUGH | | | THE STAIRWELL. | | | | | | PROVIDE MANUFACTURER INSTALLATION | | | INSTRUCTIONS FOR THE FIRE DAMPERS ON | | | THE JOBSITE AT TIME OF INSPECTION. | | | | | | PLAN INDICATES AHU 1 & 2 - MAXIMUM CFM | | | WILL BE 1,800.PROVIDE DOCUMENTATION OF | | | MANUFACTURERS ENGINEERING DATA VERIFYING | | | THE UNITS CAN NOT EXCEED 2,000 CFM, | | | OTHERWISE DUCT SMOKE DETECTORS WILL BE | | | REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2004-03-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-03-25 |
Time |
08:38 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-03-25 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2004-03-25 00:00:00 | DENIED: | | | 1.PLANS INDICATE 6" DUCT PENETRATING | | | THROUGH THE STAIRWELL.PER FBC | | | 1006.1.3.1, DUCTWORK SHALL NOT | | | PENETRATE OR RUN THROUGH A STAIRWAY | | | ENCLOSURE UNLESS IT IS A PART OF THE | | | STAIRWAY PRESSURIZATION SYSTEM. | | | | | | 2.PLEASE NOTE THE LOCATION OF THE | | | FRESH AIR INTAKE TO THE FIRST FLOOR | | | AHU. FRESH AIR INTAKES SHALL BE LOCATED | | | AS NOT TO RECIRCULATE HOT AIR EMITTED | | | OF THE CONDENSING UNITS. | | | | | | 3.PROVIDE SUBMITTAL DATA OR LETTER | | | FROM TRANE INDICATING THAT UNDER NO | | | CIRCUMSTANCE CAN THE A/C SYSTEM EXCEED | | | 2,000 CFM, OTHERWISE DUCT SMOKE | | | DETECTORS WILL BE REQUIRED.2001 | | | FBC(M) 606.2.1, DUCT SMOKE DETECTORS | | | SHALL BE INSTALLED IN SYSTEMS WITH THE | | | "DESIGN CAPACITY" GREATER THAN 2,000 | | | CFM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-10-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-23 |
Time |
11:58 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-10-23 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2003-10-23 00:00:00 | PROVISO: | | | DUCT SMOKE DETECTORS REQUIRED FOR UNITS | | | THAT HAVE A DESIGN CAPACITY GREATER THAN | | | 2,000 CFM. DUCT SMOKE DETECTORS SHALL BE | | | INSTALLED IN THE SUPPLY AIR DUCT AS PER | | | 2001 FBC(M) 606.2.1. FAN SHUTDOWN BY | | | DUCT SMOKE DETECTORS SHALL HAVE | | | NOTIFICATION TO ALARM/STROBE AS PER | | | NFPA 90A 4-4.4.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-12-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-12-10 |
Time |
16:22 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-12-10 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2002-12-10 00:00:00 | DENIED: | | | | | | 1.PROVIDE OUTSIDE AIR CALCS AS PER | | | 2001 FBC(M) TABLE 403.3. | | | | | | 2.INDICATE WHAT IS BEING STORED IN | | | THE LOFTS ABOVE THE OFFICE SPACE. | | | | | | 3.PROVIDE INFORMATION ON THE | | | VENTILATION IN THE LOFT STORAGE | | | AREAS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-07-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-03 |
Time |
09:49 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-07-03 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-03-22 |
Time |
09:07 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-03-22 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2004-03-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) FROM PREVIOUS REVIEW: A WATER RISER | | | DIAGRAM IS REQUIRED PER SEC 104.3.1.1. | | | AIR CHAMBERS ARE NOT APPROVED - IF USING | | | WATER HAMMER ARRESTORS, THEY SHALL BE | | | LOCATED NEAR THE FIXTURES, IN AN "EFFECT | | | IVE RANGE" NOT IN THE CEILING PER PDI-WH | | | 201 AND MANUF. INSTALL. INSTRUCTIONS. | | | SECTION 604.9 | | | 2) CERTIFICATE OF AUTHORIZATION REQUIRED | | | ON TITLE BLOCK. FS 481.219 | | | 3) FAC 61G1-16.004 PRINTED NAME OF PER- | | | SON SEALING PLANS REQUIRED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-10-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-23 |
Time |
14:30 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-10-23 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2003-10-23 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | 1) 104.3.1.1 A WATER RISER DIAGRAM IS | | | REQUIRED. - AIR CHAMBERS ARE NOT APPROV- | | | ED - IF USING WATER HAMMER ARRESTORS, | | | THEY SHALL BE LOCATED NEAR THE FIXTURES, | | | IN AN "EFFECTIVE RANGE" NOT IN THE CEIL- | | | ING PER PDI-WH 201 AND MANUF. INSTALL. | | | INSTRUCTIONS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-12-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-12-02 |
Time |
14:47 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2002-12-02 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2002-12-02 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A-2 HDCP TOILET ROOMS, PLEASE | | | SHOW DETAIL FOR TOILET ROOMS PER SEC. | | | 11-4.22. 11-4.2.2 DOORS SHALL NOT SWING | | | INTO THE CLEAR FLOOR SPACE REQUIRED FOR | | | ANY FIXTURE. 11-4.22.3 SHOW CLEAR FLOOR | | | SPACE FOR FIXTURES. 11-4.22.4 WATER CLO- | | | SETS SHALL COMPLY WITH 11-4.16 (18" OFF | | | WALL TO CENTER OF FIXTURE - GRAB BARS - | | | FLUSH CONTROLS - HEIGHT ECT.) 11-4.22.6 | | | LAVS SHALL COMPLY WITH 11-4.19. | | | 2) SHT A-2 DRINKING FOUNTAIN, SHOW DE- | | | TAIL PER SECTION 11-4.25. 11-4.15.2 | | | HEIGHT, AND SECTION 11-4.1.3(10)(A) SHOW | | | PROVISIONS FOR THOSE WHO HAVE TROUBLE | | | BENDING OR STOOPING. (EITHER A HIGH/LOW | | | D.F. OR SUPPLY DRINKING CUP DISPENSOR AT | | | D.F. | | | 3) SHT A-3 IF VERTICAL ACCESSIBLITY IS | | | REQUIRED THAN ALL TOILET ROOMS SHALL BE | | | REQUIRED TO BE ACCESSIBLE. | | | 4) PLEASE INDICATE TYPE OF MATERIALS TO | | | BE WAREHOUSED AT SPACE. ANSWER MAY RE- | | | QUIRE ADDITIONAL REVIEW COMMENTS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|