| Plan Review Stops For Permit 02110130 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-02-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-02-04 |
Time |
13:53 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-02-04 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-01-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-23 |
Time |
15:58 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-01-23 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-12-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-17 |
Time |
06:56 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2002-12-17 |
Time |
06:56 |
Sent To |
P |
|
| Notes |
| 2002-12-23 00:00:00 | NOTES REDLINED. | | | REVISE BEFORE ROUGH. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-12-21 |
Time |
05:20 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2002-11-25 |
Time |
10:51 |
Sent To |
B |
|
| Notes |
| 2002-11-25 00:00:00 | ************** UNSAT ************** | | | | | | PLEASE NOTE, PLANS NEED TO CORRELATE | | | W/ MASTER. | | | | | | PLEASE SEE MISSING ARC FAULT, PER 210-12 | | | | | | PLEASE SEE, DRYER AS 1-P-20A. | | | | | | PLEASE SEE, MISSING BATH GFI. 210-11-C-3 | | | | | | | | | PLEASE SEE OTHER MODELS FOR ANY OTHER | | | COMMENTS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-01-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-15 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-01-15 |
Time |
16:40 |
Sent To |
B |
|
| Notes |
| 2003-01-15 00:00:00 | TO ROBERT BROWN'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2002-12-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-27 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-12-27 |
Time |
14:53 |
Sent To |
B |
|
| Notes |
| 2002-12-27 00:00:00 | TO ROBERT BROWNS DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2002-12-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-16 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-12-16 |
Time |
17:39 |
Sent To |
E |
|
| Notes |
| 2002-12-16 00:00:00 | TO DVP./WRT. | | | TO DVP./WRT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-04 |
Time |
18:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-11-04 |
Time |
18:29 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-11-25 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2002-11-25 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2002-11-25 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2002-11-25 00:00:00 | PLANS SAME AS MASTER PERMIT # 02041257 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-12-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-23 |
Time |
06:56 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2002-12-21 |
Time |
05:20 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-11-20 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-11-13 |
Time |
08:21 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2002-11-20 |
Time |
19:40 |
Sent To |
R |
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2003-01-23 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-01-23 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-01-23 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2003-01-23 00:00:00 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | --PROVISO-- | | | PROVIDE A CMU COLUMN UNDER THE | | | RELOCATED GIRDER TRUSS AS MARKED ON THE | | | PLANS. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2002-12-30 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2002-12-30 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2002-12-30 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2002-12-30 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | ***NOTE***: | | | CHAPTER 553.80(2)(B) FLORIDA STATUTES | | | STATES THAT A LOCAL GOVERNMENT SHALL | | | IMPOSE A FEE OF FOUR TIMES THE FEE FOR | | | PLAN REVIEW, IF PLANS ARE REJECTED THREE | | | OR MORE TIMES FOR REPEATED FAILURE TO | | | CORRECT A CODE VIOLATION. | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 12/23/02: | | | | | | 2) FBC* 104.2.2SOME OF THE | | | ARCHITECTURAL SHEETS ARE STILL NOT | | | PROPERLY SEALED, FLORIDA STATUTES | | | 61G1-16.001 THRU 16.003.SEE NOTE ABOVE | | | | | | 3) SHEET A-05.THE AMENDMENT TO THE | | | INTERMEDIATE TRUSS ANCHOR FOR GIRDER | | | TRUSS SG2 IS NOTED, BUT THE ANCHORS AT | | | THE ENDS OF THIS TRUSS HAVE STILL NOT | | | BEEN AMENDED.WHEN THE TRUSS WAS MOVED | | | TOWARD THE REAR OF THE BUILDING, THE | | | RELEVANT TRUSS ANCHOR ANNOTATION WAS NOT | | | AMENDED TO SUIT.AS A RESULT OF THIS, | | | THE PLANS CURRENTLY SHOW A TRUSS ANCHOR | | | MARK A (UPLIFT CAPACITY 860 LBS) AT EACH | | | END OF THIS TRUSS.IS THIS INTENTIONAL/ | | | SUFFICIENT?.THE PREVIOUS TRUSS END | | | ANCHOR ANNOTATION FOR THIS TRUSS IS | | | STILL SHOWN ON THE PLAN BUT NOT POINTING | | | TO ANY TRUSS UNDER THE REVISED LAYOUT. | | | ALSO, THE 'REQUIRED UPLIFT' AND TRUSS | | | ANCHOR REFERENCES ON THE LEFT EDGE OF | | | SHEET A-05 HAVE NOT PRINTED (TRUNCATED | | | BY LEFT MARGIN).FINALLY, DUE TO | | | RELOCATION OF GIRDER TRUSS SG2, THE | | | AMENDED INTERMEDIATE TRUSS ANCHOR | | | 'MARK J' IS NOT ALIGNED WITH A CMU | | | COLUMN AND NO TIE BEAM IS SPECIFIED, ON | | | SHEET A-05, AT THE HEAD OF THE COVERED | | | PATIO SIDE WALL.SHOW THE MEANS FOR | | | TRANSFERRING THE LOADS FROM THE TRUSS | | | ANCHOR TO THE CMU WALL. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2002-12-23 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2002-12-23 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2002-12-23 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2002-12-23 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 11/25/02: | | | | | | 2) FBC* 104.2.2SOME OF THE | | | ARCHITECTURAL SHEETS ARE STILL NOT | | | PROPERLY SEALED, FLORIDA STATUTES | | | 61G1-16.001 THRU 16.003. | | | | | | 3) SHEET A-05.REMOVAL OF COLUMN | | | BETWEEN THE LIVING ROOM AND MASTER | | | BEDROOM WIC.THIS COLUMN WAS SUPPORTING | | | GIRDER TRUSS SG2 AND WAS SUBJECT TO AN | | | UPLIFT OF 4911 LBS (SEE 'FLORIDA QUALITY | | | TRUSS' DESIGN).THE PROPOSED REVISION | | | OMITS THE COLUMN AND RELOCATES THE | | | GIRDER TRUSS WITHOUT HIGHLIGHTING THE | | | NEW SUPPORT POINTS AND STATING THE | | | RESPECTIVE UPLIFTS.SHEET A-05 SHALL BE | | | REVISED TO CLEARLY SHOW THE LOCATION AND | | | MAGNITUDE OF THE UPLIFT FORCES. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2002-11-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-11-20 |
Time |
19:40 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2002-11-25 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2002-11-25 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) THE SURVEY DRAWING SHALL SHOW AN | | | EASEMENT ON LOT 44 FOR MEANS OF EGRESS | | | FROM BEDROOM 2 TO THE STREET, VIA THE | | | ATRIUM. | | | | | | 2) FBC* 104.2.2THE ARCHITECTURAL | | | SHEETS ARE NOT PROPERLY SEALED, FLORIDA | | | STATUTES 61G1-16.001 THRU 16,003. | | | | | | 3) SHEET A-05.REMOVAL OF THE COLUMN | | | BETWEEN THE LIVING ROOM AND MASTER | | | BEDROOM WIC WILL RESULT IN INCREASED | | | LOADS AT THE REMAINING TRUSS SUPPORT | | | POINTS.THE UPLIFTS ON THE ROOF FRAMING | | | PLAN HAVE NOT BEEN REVISED TO REFLECT | | | THE INCREASE. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-11-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-04 |
Time |
18:29 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
| Notes |
|
|