| Plan Review Stops For Permit 02110098 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-12-19 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-12-19 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-12-19 |
Time |
10:22 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-11-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-11-13 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-11-12 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2002-11-13 00:00:00 | PLEASE SHOW THE WIND DESIGN PRESSURES | | | FOR THE NEW STOREFRONT SYSTEM IN | | | ACCORDANCE WITH FBC 1606.1.7 | | | | | | IF TEST REPORTS AND/OR PRODUCT APPROVALS | | | FOR THE STORE FRONT SYSTEM ARE NOT | | | INCLUDED WITH THIS PERMIT APPLICATION A | | | SEPARATE PERMIT, PLANS AND FEES WILL BE | | | REQUIRED FOR THAT WORK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-11-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-14 |
Time |
14:21 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2002-11-14 |
Time |
14:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2002-12-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-12-24 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2002-12-24 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2002-12-24 00:00:00 | PROVISO: | | | | | | AS PER MIKE CARSILLO (ASSISTANT FIRE | | | MARSHAL), CURTAIN BY TENANT NEAR STOCK | | | ROOM IS NOT ALLOWED.PLEASE SEE NFPA | | | 101, THE LIFE SAFETY CODE, 200 EDITION, | | | SECTION 7.1.10.2.1. | | | | | | WHEN PAINTING CEILING, EXTREME CARE | | | SHALL BE TAKEN TO PREVENT THE | | | APPLICATION OF PAINT TO EXISTING | | | SPRINKLER HEADS.IF FIRE SPRINKLER | | | HEADS ARE PAINTED, THEY ARE TO BE | | | REPLACED AND NOT CLEANED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-11-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-11-22 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-11-22 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2002-11-22 00:00:00 | 1) CURTAIN BY TENANT NEAR STOCKROOM IS | | | NOT ALLOWED. PLEASE SEE NFPA 101, | | | THE LIFE SAFETY CODE, 2000 EDITION, | | | SECTION 7.1.10.2.1. | | | | | | 2) WHEN PAINTING CEILING, EXTREME CARE | | | SHALL BE TAKEN TO PREVENT THE | | | APPLICATION OF PAINT TO EXISTING | | | SPRINKLER HEADS. IF FIRE SPRINKLER | | | HEADS ARE PAINTED, THEY ARE TO BE | | | REPLACED AND NOT CLEANED. | | | | | | 3) A FIRE SPRINKLER HEAD IS REQUIRED | | | DIRECTLY OUTSIDE OF THE ENTRY DOOR. | | | (VESTIBULE) | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2002-12-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-16 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-12-16 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2002-12-16 00:00:00 | TO COM BOARD #12./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-04 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-04 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2002-11-04 00:00:00 | TO COMM. BOARD # 41./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-12-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-12-24 |
Time |
08:01 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2002-12-24 |
Time |
08:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-12-02 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-12-19 |
Time |
10:39 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2002-12-02 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2002-12-02 00:00:00 | DENIED: | | | | | | PROVIDE LOCATION FOR THE TERMINATION OF | | | CONDESATE (DRYWELL, STORM?).INDICATE | | | WHERE THE TERMINATION OF THE EMEREGENCY | | | DRAIN WILL BE LOCATED.AS PER 2001 | | | FBC(M) 307.2.3, AT A CONSPICUOUS POINT | | | TO SERVE AS AN ALARM THAT THE PRIMARY | | | DRAIN IS RESTRICTED. | | | | | | PROVISO: | | | EQUIPMENT RACK FOR CONDENSER SHALL | | | COMPLY WITH 2001 FBC 1511.7, IF THIS IS | | | A NEW INSTALLATION & NOT EXISTING. | | | SEE PLAN SHEET MP-2. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-12-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-12-02 |
Time |
14:09 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2002-12-02 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2002-12-02 00:00:00 | BACKFLOW REQUIRED |
|
|