| Plan Review Stops For Permit 02102235 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-06-24 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-07-08 |
Time |
11:19 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2003-06-18 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2003-06-18 00:00:00 | BUILDING PROVISO | | | | | | 1) SUBMIT A RECORDED COPY OF THE | | | REVISED CONDO RULES AND REGULATIONS | | | ADDRESSING THE HURRICANE PREPARATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-06-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2003-06-03 |
Time |
13:08 |
Rev Time |
4.00 |
| Received By |
rmcdouga |
Date |
2003-06-03 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2003-06-03 00:00:00 | BUILDING DENIED | | | | | | 1) THE LETTER FROM PALM BEACH LIFTS IS | | | REQUIRED TO HAVE AN ORIGINAL SIGNATURE | | | AND BE NOTARIZED. | | | | | | 2) THE STORM PANEL INSTALLATION LETTER | | | IS REQUIRED TO BE ADDRESSED TO THE | | | BUILDING OFFICIAL (NEIL MELICK). IT IS | | | REQUIRED TO BE FROM A PRINCIPAL OF THE | | | COMPANY. IT MUST BE SIGNED AND NOTARIZED | | | OR HAVE THE CORPORATE SEAL. | | | | | | 3) THE COVER LETTER INDICATES THAT THE | | | SIDELITES AT THE ENTRY DOORS FOR BOTH | | | THE FIRST AND SECOND FLOOR UNITS ARE | | | REQUIRED TO HAVE STORM PANELS. THE PRE- | | | STORM PLAN AND THE CONDO DOCUMENTS DO | | | NOT INDICATE THIS. THEY BOTH STATE THAT | | | THE SECOND FLOOR UNITS HAVE IMPACT | | | WINDOWS AND DOORS AND DO NOT REQUIRE | | | STORM PANELS. THE SIDELIGHT OF THE ENTRY | | | DOORS TO THE SECOND FLOOR UNITS THAT ARE | | | REQUIRED TO BE SHUTTERED MUST BE | | | ADDRESSED. THE LETTER, THE PREPARATION | | | PLAN AND THE CONDO DOCUMENTS MUST ALL BE | | | IN AGREEMENT. | | | | | | 4) THE ENERGY CALCULATION FORM FOR UNIT | | | "D" IS NOT INDICATED AS WORST CASE. THIS | | | WILL REQUIRE THE FORM FOR THIS ONE UNIT | | | TO HAVE THE SITE LOCATION ON THE FORM & | | | TO BE SUBMITTED WITH EACH BUILDING | | | PERMIT APPLICATION. | | | THE PERSON PREPARING THE ENERGY CALCS. | | | ARE REQUIRED TO SIGN AND DATE THEM. | | | | | | 5) A SIGNED AND SEALED COPY OF THE SOIL | | | REPORT IS REQUIRED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-04-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2003-04-16 |
Time |
17:37 |
Rev Time |
6.00 |
| Received By |
rmcdouga |
Date |
2003-04-16 |
Time |
17:37 |
Sent To |
|
|
| Notes |
| 2003-04-16 00:00:00 | BUILDING DENIED | | | | | | NOTE: IMPACT FEES, SURVEY AND NOTICE OF | | | COMMENCEMENT WILL BE REQUIRED FOR EACH | | | BUILDING APPLIED FOR UNDER THE MASTER. | | | EACH BUILDING WILL BE REVIEWED FOR | | | ZONING AND TABLE 600 ISSUES. IF YOU WILL | | | BE CONSTRUCTING MULTIPLE BUILDINGS AT | | | THE SAME TIME A SPECIAL INSPECTOR MAY BE | | | REQUIRED TO AVOID CONSTRUCTION DELAYS, | | | DUE TO A LARGE VOLUME OF INSPECTIONS. | | | PLEASE CALL DON NEELY AT 659-8096 EXT. | | | 8333. | | | | | | 1) THE LETTER FROM PALM BEACH LIFTS HAS | | | THE WRONG MASTER PERMIT NUMBER. | | | | | | 2) ON SHEET A3 THE DOOR FROM THE GARAGE | | | TO THE HABITABLE AREA AT THE BEGONIA | | | MODEL IS MISSING THE 3/4 FROM IN FRONT | | | OF THE HR RATED. | | | | | | 3) A WRITTEN STORM PANEL INSTALLATION | | | PLAN MUST BE SUBMITTED AND APPROVED BY | | | THE BUILDING OFFICIAL. | | | | | | 4) THE KEY PLANS FOR THE STORM PANELS | | | THE REVERSE OF THE PLANS. PLEASE SUBMIT | | | KEY PLANS THAT MATCH THE MASTER PLANS. | | | THERE WAS NO KEY PLAN SUBMITTED FOR THE | | | SECOND FLOOR UNITS ENTRY DOORS AND | | | SIDELITE ASSEMBLIES WHICH ARE LOCATED AT | | | GRADE LEVEL. WILL THESE BE IMPACT RATED? | | | | | | 5) A WRITTEN STORM PANEL STORAGE AND | | | INSTALLATION PLAN MUST BE SUBMITTED AND | | | APPROVED BY THE BUILDING OFFICIAL. | | | | | | 6) THE ENERGY CALCULATIONS ARE NOT | | | CORRECT. THE SQFT AREAS LISTED DO NOT | | | CORRESPOND WITH THE PLANS FOR TOTAL | | | CONDITIONED AREA, UNDER ATTIC, ETC. | | | IDENTIFY EACH MODEL ON THE ENERGY CALCS. | | | WITH THE CORRESPONDING DESIGNATION THAT | | | IS LISTED ON THE PLANS. | | | | | | 7)THE PRODUCT APPROVAL FOR THE UNCLIPPED | | | MULLIONS EXPIRES ON 5-1-03 AND THE ONE | | | FOR THE CLIPPED MULLIONS EXPIRED ON | | | 5-30-02. NEITHER ONE IS APPROVED FOR | | | USE AS PART OF AN IMPACT RESISTANT | | | ASSEMBLY. | | | | | | 8) SUBMIT PRODUCT APPROVAL FOR OUTSWING | | | DOOR WITH ONE SIDELITE. THE ONES THAT | | | WERE SUBMITTED ARE EXPIRED AND HAVE THE | | | COVERSHEET FOR A DOUBLE OUTSWING DOOR. | | | | | | 9) SUBMIT A SIGNED AND SEALED COPY OF | | | THE SOIL REPORT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 | | | 9) S |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-12-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2002-12-11 |
Time |
09:11 |
Rev Time |
6.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-12-11 00:00:00 | BUILDING DENIED | | | | | | NOTE: IMPACT FEES, SURVEY AND NOTICE OF | | | COMMENCEMENT WILL BE REQUIRED FOR EACH | | | BUILDING APPLIED FOR UNDER THE MASTER. | | | | | | 1) INDICATE THE INTERNAL PRESSURE | | | COEFFICENT ON C1. IT IS + OR - 0.18 FOR | | | AN ENCLOSED STRUCTURE. | | | | | | 2) PLEASE REVISE PLAN NOTE #11 ON C1, | | | HURRICANE SHUTTERS ARE REQUIRED IN WPB, | | | WHICH IS IN THE WIND BORN DEBRIS REGION, | | | BUT NOT IN THE HVHZ. FBC 1606.1.4 | | | | | | 3)REVISE THE NOTES ON A3 ON THE REQUIRED | | | APPROVED CLOSERS TO REFERENCE THE 2001 | | | FLORIDA BUILDING CODE. | | | | | | 4) THE C LABEL DESIGNATIONS FOR FIRE | | | RATED DOORS IS NO LONGER USED. SEE FBC | | | 705.1.3.2.1. SPECIFY 3/4 HOUR RATED FIRE | | | DOORS ON PLANS WHERE REQUIRED PER FBC | | | TABLE 705.1.2. | | | | | | 5) THE WALL BELOW AND THE UNDERSIDE OF | | | THE STAIRS ARE REQUIRED TO HAVE A ONE | | | HOUR FIRE RATING. PLEASE INDICATE THIS | | | ON FLOOR PLAN ON A3. | | | | | | 6) THE CLOSET DOORS IN BEDROOMS #2 OF | | | UNIT A, #3 OF UNIT D AND #3 OF UNIT C | | | MUST PROVIDE A 32"NOMINAL CLEAR OPENING | | | IN ORDER FOR THE USER TO PASS THROUGH TO | | | ACCESS THE CONTENTS IS REQUIRED BY THE | | | FAIR HOUSING ACT. | | | | | | 7) THE DOUBLE DOORS TO THE DEN IN UNITS | | | D AND A, MUST HAVE BOTH LEAFS ACTIVE OR | | | THE ONE ACTIVE LEAF MUST PROVIDE A 32" | | | CLEAR OPENING PER FAIR HOUSING ACT. | | | INDICATE ON THE PLANS ON SHEETS A3 AND | | | A4 & FOR OPTIONS Q2,Q3,D2,D3 ON A17 AND | | | A18. | | | | | | 8) THE MASTER BATH W/C OPTIONS Q1,S1,M2 | | | AND D1 ON SHEETS A17 AND A18 DO NOT | | | COMPLY WITH FAIR HOUSING REQUIREMENTS. | | | | | | 9) INDICATE THE CLEAR FLOOR SPACE | | | DIMENSIONS AT THE BATHROOM FIXTURES WITH | | | SHADED AREAS. | | | | | | 10) THE PROJECT TITLE BLOCK ON THE PLANS | | | ARE INCORRECT. PLEASE REVISE. | | | | | | 11)ON SHEET A4 SECTIONS A,B,C ARE TAGGED | | | AS BEING LOCATED ON A6, BUT ARE ON A7. | | | SECTIONS 1,3 AND 5 ARE MARKED AS BEING | | | ON A7, BUT ARE LOCATED ON A8. PLEASE | | | CORRECT. | | | | | | 12) SHEET A5 AND A6 HAVE A NOTE THAT | | | INDICATES STUCCO OVER CONCRETE BLOCK AT | | | THE EXTERIOR WALLS ABOVE THE GARAGE, | | | WHICH ARE WOOD FRAME. PLEASE CORRECT. | | | | | | 13) REVISE THE HANDRAIL AND PARTY WALL | | | NOTES ON A7 TO REFERENCE THE 2001 FBC. | | | | | | 14) REVISE THE ATTIC VENTILATION NOTES | | | ON A10 TO REFERENCE THE 2001 FBC. | | | | | | 15) PROVIDE A DETAIL OF THE STAIRS THAT | | | INDICATES THE RISER AND TREAD DIMENSIONS | | | AND SHOWS COMPLIANCE WITH FBC 1007.3. | | | | | | 16) PROVIDE DETAILS OF THE INTERIOR | | | GUARDRAIL AT THE TOP OF THE STAIRS AND | | | IN FRONT OF THE ELEVATOR. INDICATE THE | | | ATTACHMENTS, DIMENSIONS, ETC. SEE FBC | | | 1015. | | | | | | 17) THE KEY PLANS AND INSTALLATION | | | SCHEDULES FOR THE STORM PANELS DO NOT | | | CORRESPOND WITH THE PLANS. A WRITTEN | | | STORM PANEL STORAGE AND INSTALLATION | | | PLAN MUST BE SUBMITTED AND APPROVED BY | | | THE BUILDING OFFICIAL. | | | | | | 18) THE ENERGY CALCULATIONS ARE REQUIRED | | | TO BE SIGNED BY THE OWNER/AGENT. THE | | | CONDITIONED FLOOR AREA ON THE ENERGY | | | CALCS. DOES NOT MATCH THE CONDITIONED | | | AREA GIVEN ON THE PLANS. | | | | | | 19) PROVIDE (2) CURRENT AND COMPLETE | | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | | APPROVALS FOR: | | | - OUTSWING DOORS W/SIDELITES (EXPIRED) | | | - STRUCTURAL MULLIONS (EXPIRED) | | | - SLIDING GLASS DOORS (BOTH ARE EXPIRED) | | | - OVERHEAD GARAGE DOOR(DRAWING SUBMITTED | | | IS FOR DOOR WITH MAXIMUM WIDTH OF 9') | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-12 |
Time |
11:38 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-07-12 00:00:00 | *** UNSAT *** | | | | | | PLANS/ REVISIONS BROUGHT IN, C.O> ISSUED | | | . |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2003-06-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-06 |
Time |
10:11 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-06-30 |
Time |
16:23 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-05-08 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-26 |
Time |
10:55 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-05-08 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-04-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-03 |
Time |
11:54 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-04-03 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2003-04-03 00:00:00 | ************ UNSAT *************** | | | | | | PLEASE SEE NOTES PREVIOUSLY DONE ON | | | 3/19/03 BY BILL TROBAUGH. THIS WAS PUT | | | IN AS PROVISO BY MISTAKE. PLEASE NOTE, | | | PLAN REVIEW/CHECK MUST HAVE ALL COMMENTS | | | DONE. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-03-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-03-19 |
Time |
11:06 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-03-18 |
Time |
17:43 |
Sent To |
P |
|
| Notes |
| 2003-03-19 00:00:00 | PROVISO | | | ~~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE CORRECT THE FOLLOWING AND | | | RESUBMIT FOR REVIEW PRIOR TO ROUGH | | | ELECTRICAL INSPECTIONS. | | | | | | 1} NOTE #18 ON SHEET C1 MAKES A | | | REFERENCE TO "ALL DWELLING ROOM | | | RECEPTACLES" BEING ON ARC FAULT | | | BREAKERS,WHICH CONTRADICTS THE NOTE ON | | | A-16.PLEASE CORRECT TO SHOW THE INTENT | | | OF THE ARCHITECT. | | | | | | 2} THERE ARE NO MAIN DISCONNECTS SHOWN | | | ON THE RISER DIAGRAM AND PANELS ARE | | | SWOWN AS MLO.PLEASE | | | CLARIFY.(DISCONNECTS ARE SHOWN ON SHEET | | | A-10 OF THE DRAWING). | | | | | | 3} THE LIVING ROOM IN UNIT "A",AND THE | | | GREAT RM IN UNIT "C" HAVE RECEPTACLE | | | SPACING NOT IN COMPLIANCE WITH 210-52, | | | PLEASE CORRECT. | | | | | | 4} THE ELEVATOR OCP ON PANELS "C&D" DO | | | NOT MATCH THE THE ELEVATOR SPEC'S FOR | | | 30AMPS.PLEASE CLARIFY AND RECALCULATE | | | THE PANEL LOADS IF NECESSARY. | | | | | | 5} PLEASE NOTE THAT MOST OF THE | | | EQUIPMENT DISCONNECTS ARE NOT SHOWN TO | | | COMPLY WITH 110-26.PLEASE CHANGE THE | | | DRAWINGS TO SHOW COMPLIANCE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/659-8096 EXT. 8392 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-12-05 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-18 |
Time |
08:25 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2002-12-02 |
Time |
18:08 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-07-08 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-07-08 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-07-08 |
Time |
11:18 |
Sent To |
B |
|
| Notes |
| 2003-07-08 00:00:00 | REVISION 6-25-03 NAM |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-04-18 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-04-18 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-04-18 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2003-04-18 00:00:00 | PLEASE SEE NOTES PREVIOUSLY DONE BY | | | CAPT. MIKE CARSILLO ON 12/05/02. | | | | | | NATE MCCRAY, CAPTAIN | | | 659-8096, 8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2002-12-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-05 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-12-05 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2002-12-05 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | | TO, DURING, AND AFTER CONSTRUCTION. | | | | | | 2) BUILDING ADDRESSES REQUIRED ON UNITS. | | | | | | 3) PORTABLE FIRE EXTINGUISHERS REQUIRED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-07-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-06 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-06 |
Time |
10:11 |
Sent To |
E |
|
| Notes |
| 2004-07-06 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-01-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-28 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-28 |
Time |
14:57 |
Sent To |
M |
|
| Notes |
| 2004-01-28 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-06-26 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-26 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-26 |
Time |
10:55 |
Sent To |
E |
|
| Notes |
| 2003-06-26 00:00:00 | DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-23 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-23 |
Time |
12:38 |
Sent To |
B |
|
| Notes |
| 2003-06-23 00:00:00 | RM DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-06-16 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-16 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-16 |
Time |
13:51 |
Sent To |
P |
|
| Notes |
| 2003-06-16 00:00:00 | COMM BOARD #63 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-05 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-05 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2003-05-05 00:00:00 | COMM BOARD #54 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-03-24 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-18 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-18 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2003-03-18 00:00:00 | COMM BOARD #56 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2004-02-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-11 |
Time |
07:25 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2004-02-11 |
Time |
07:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2003-07-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-28 |
Time |
14:58 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2003-07-07 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
N |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-02 |
Time |
18:25 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-06-23 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2003-06-23 00:00:00 | CALLED CONTRACTOR ADDITIONAL PLANS WHERE | | | SUBMITTED BY MISTAKE.PLANS APPROVED | | | 5-15-03 ARE THE APPROVED SET. ADDITIONAL | | | PLANS TO BE SENT BACK WITH CONTRACTOR. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-05-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-05-15 |
Time |
13:14 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-05-15 |
Time |
13:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-04-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-04-03 |
Time |
11:09 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-04-03 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2003-04-03 00:00:00 | DENIED:2ND PLAN CHECK UNITS A,B,C & D | | | | | | COMMENTS FROM PLAN CHECK DATED 11-30-02 | | | NOT ADDRESSED. | | | | | | 1.INDICATE OUTSIDE AIR REQUIREMENT BY | | | NATURAL 2001 FBC(M) 402.2 OR MECHANCIAL | | | TABLE 403.3.PROVIDE CALCULATIONS. | | | | | | 2.MISSING DUCT SIZE FROM MODEL C THE | | | MASTER BEDROOM SUPPLY DUCT.8"? | | | | | | 3.SMOKE DETECTORS SHALL BE INSTALLED | | | SUPPLY SYSTEMS WITH A DESIGN CAPACITY | | | GREATER THAN 2,000 CFM, IN THE SUPPLY | | | AIR DUCT. 2001 FBC(M) 606.2.1OR | | | UPON ACTIVATION, THE SMOKE DETECTORS | | | SHALL SHUTDOWN THE AIR DISTRIBUTION | | | SYSTEM. 2001 FBC(M) 606.4 | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-11-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-11-30 |
Time |
11:41 |
Rev Time |
1.00 |
| Received By |
hmoser |
Date |
2002-11-30 |
Time |
11:41 |
Sent To |
E |
|
| Notes |
| 2002-11-30 00:00:00 | PLAN DENIED | | | 1) DESIGN TO 2001 MECHANICAL CODE | | | 2) VARIFY TYPE OF VENTILATION USED FOR | | | FRESH AIR NATURAL SECTION 402 OR | | | MECHANICAL SECTION 403 | | | 3) NEED CALCULATION FOR TYPE OF | | | VENTILATION USED | | | 4) REFER TO SECTION 601.4 BALANCED | | | RETURN AIR | | | 5)REFER TO SECTION 606 SMOKE DETECTION | | | SYSTEM CONTROL | | | 6) SOME DUCT SIZE MISSING ON PLANS | | | 7) CONDENSATE LINE MUST TERMINATE 12IN. | | | FROM BUILDING FBC.SECTION 1503.4.4 | | | PLAN REVIEW BY HAROLD MOSER | | | (561)659-8096 EXT.8390 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2003-07-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-02 |
Time |
18:25 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-07-02 |
Time |
18:24 |
Sent To |
M |
|
| Notes |
| 2003-07-02 00:00:00 | REVISION OK - CHANGED UNIT LAYOUTS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-06-30 |
Time |
16:23 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-06-23 |
Time |
15:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2003-06-02 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-16 |
Time |
13:52 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-06-02 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2003-06-02 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING. | | | | | | A) COMMENT FROM 1ST AND 2ND REVIEW NOT | | | ADDRESSED. | | | 1) SHT A-16 CARRISA MODEL, BEGONIA MODEL | | | & DATURA MODEL, SANT DRAIN REQUIRED TO | | | BE MINIMUM OF 3" UP TO WHERE THE TUB IS | | | TAKEN OFF BRANCH DRAIN. TABLE 909.3 & | | | SECTION 909.1 WET VENT. SINCE THIS IS | | | A MASTER MODEL, IT SHALL BE CORRECTED TO | | | MEET CODE REQUIREMENTS. | | | SEE FLORIDA STATUTE 553.80(2)(B) ATTACH- | | | ED FOR IMFORMATION CONCERNING 4 TIMES | | | THE FEE AFTER 3RD REVIEW. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-03-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-24 |
Time |
15:56 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-03-24 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2003-03-24 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FHA-98 AMENDED DESIGN MANUAL | | | | | | 1) SHT A-3 CARISSA MODEL, FLOOR PLAN | | | SHOWS BATH #3 WITH A W/C, LAV, & SHOWER. | | | SHT A-16 SANT. RISER DIAGRAM SHOWS W/C, | | | LAV, & A BAR SINK. PLEASE CLAIRFY. | | | 2) SHT A-16 CARRISA MODEL, BEGONIA MODEL | | | & DATURA MODEL, SANT DRAIN REQUIRED TO | | | BE MINIMUM OF 3" UP TO WHERE THE TUB IS | | | TAKEN OFF BRANCH DRAIN. TABLE 909.3 & | | | SECTION 909.1 WET VENT. (SEE 2ND FLOOR | | | MASTER BATH FOR ALAMANDA MODEL) | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-11-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-03-19 |
Time |
11:06 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2002-11-13 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2002-11-13 00:00:00 | DENIED; | | | PAGE A-16. PLUMBING RISER DIAGRAMS. | | | UNIT "A" AND "B" | | | 1.MASTER W/C 3" WET VENT REQUIRED. SEE | | | FBC PLUMBING TABLE 908.3. | | | 2.KITCHEN BRANCH. 2" DRY VENT NOT | | | REQUIRED. | | | 3.RISERS ARE GOING TO WRONG APARTMENTS. | | | "A" SHOULD GO TO "C" ECT. | | | 4.FLOOR PLAN SHOWS L.T.S ON FIRST FLOOR | | | NONE SHOWN ON RISER DIAGRAMS. | | | UNITS "C" AND "D" | | | 1.RISER DIAGRAM SHOWS 2 WASHERS FLOOR | | | PLAN SHOWS ONE. | | | 2.MASTER W/C WET VENT REQUIRED TO BE 3" | | | SEE TABLE 908.3. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT.8369 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2003-07-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2003-07-10 |
Time |
16:05 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2003-07-10 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2003-07-10 00:00:00 | REVISION TO CHANGE THE 1ST AND 2ND FLOOR | | | LEFT SIDE UNITS TO BEGONIA AND DATURA | | | FLOOR PLANS IS OK. REVISED UNITS ARE | | | MIRROR IMAGE OF RIGHT SIDE UNITS. SQUARE | | | FOOTAGE AND FOOTPRINT DID NOT CHANGE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-06-19 |
Time |
10:29 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-05-19 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-05-19 00:00:00 | ZONING DOES NOT LOOK AT MASTERS!!!! | | | PLEASE DO NOT PUT ANY MASTERS PLANS | | | TOO ZONING. |
|
|