Plan Review Details - Permit 02102235
Plan Review Stops For Permit 02102235
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-06-24 Cont ID  
Sent By nmccray Date 2003-07-08 Time 11:19 Rev Time 3.00
Received By rmcdouga Date 2003-06-18 Time 14:58 Sent To  
Notes
2003-06-18 00:00:00BUILDING PROVISO
  
 1) SUBMIT A RECORDED COPY OF THE
 REVISED CONDO RULES AND REGULATIONS
 ADDRESSING THE HURRICANE PREPARATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-06-03 Cont ID  
Sent By rmcdouga Date 2003-06-03 Time 13:08 Rev Time 4.00
Received By rmcdouga Date 2003-06-03 Time 13:08 Sent To  
Notes
2003-06-03 00:00:00BUILDING DENIED
  
 1) THE LETTER FROM PALM BEACH LIFTS IS
 REQUIRED TO HAVE AN ORIGINAL SIGNATURE
 AND BE NOTARIZED.
  
 2) THE STORM PANEL INSTALLATION LETTER
 IS REQUIRED TO BE ADDRESSED TO THE
 BUILDING OFFICIAL (NEIL MELICK). IT IS
 REQUIRED TO BE FROM A PRINCIPAL OF THE
 COMPANY. IT MUST BE SIGNED AND NOTARIZED
 OR HAVE THE CORPORATE SEAL.
  
 3) THE COVER LETTER INDICATES THAT THE
 SIDELITES AT THE ENTRY DOORS FOR BOTH
 THE FIRST AND SECOND FLOOR UNITS ARE
 REQUIRED TO HAVE STORM PANELS. THE PRE-
 STORM PLAN AND THE CONDO DOCUMENTS DO
 NOT INDICATE THIS. THEY BOTH STATE THAT
 THE SECOND FLOOR UNITS HAVE IMPACT
 WINDOWS AND DOORS AND DO NOT REQUIRE
 STORM PANELS. THE SIDELIGHT OF THE ENTRY
 DOORS TO THE SECOND FLOOR UNITS THAT ARE
 REQUIRED TO BE SHUTTERED MUST BE
 ADDRESSED. THE LETTER, THE PREPARATION
 PLAN AND THE CONDO DOCUMENTS MUST ALL BE
 IN AGREEMENT.
  
 4) THE ENERGY CALCULATION FORM FOR UNIT
 "D" IS NOT INDICATED AS WORST CASE. THIS
 WILL REQUIRE THE FORM FOR THIS ONE UNIT
 TO HAVE THE SITE LOCATION ON THE FORM &
 TO BE SUBMITTED WITH EACH BUILDING
 PERMIT APPLICATION.
 THE PERSON PREPARING THE ENERGY CALCS.
 ARE REQUIRED TO SIGN AND DATE THEM.
  
 5) A SIGNED AND SEALED COPY OF THE SOIL
 REPORT IS REQUIRED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-04-17 Cont ID  
Sent By rmcdouga Date 2003-04-16 Time 17:37 Rev Time 6.00
Received By rmcdouga Date 2003-04-16 Time 17:37 Sent To  
Notes
2003-04-16 00:00:00BUILDING DENIED
  
 NOTE: IMPACT FEES, SURVEY AND NOTICE OF
 COMMENCEMENT WILL BE REQUIRED FOR EACH
 BUILDING APPLIED FOR UNDER THE MASTER.
 EACH BUILDING WILL BE REVIEWED FOR
 ZONING AND TABLE 600 ISSUES. IF YOU WILL
 BE CONSTRUCTING MULTIPLE BUILDINGS AT
 THE SAME TIME A SPECIAL INSPECTOR MAY BE
 REQUIRED TO AVOID CONSTRUCTION DELAYS,
 DUE TO A LARGE VOLUME OF INSPECTIONS.
 PLEASE CALL DON NEELY AT 659-8096 EXT.
 8333.
  
 1) THE LETTER FROM PALM BEACH LIFTS HAS
 THE WRONG MASTER PERMIT NUMBER.
  
 2) ON SHEET A3 THE DOOR FROM THE GARAGE
 TO THE HABITABLE AREA AT THE BEGONIA
 MODEL IS MISSING THE 3/4 FROM IN FRONT
 OF THE HR RATED.
  
 3) A WRITTEN STORM PANEL INSTALLATION
 PLAN MUST BE SUBMITTED AND APPROVED BY
 THE BUILDING OFFICIAL.
  
 4) THE KEY PLANS FOR THE STORM PANELS
 THE REVERSE OF THE PLANS. PLEASE SUBMIT
 KEY PLANS THAT MATCH THE MASTER PLANS.
 THERE WAS NO KEY PLAN SUBMITTED FOR THE
 SECOND FLOOR UNITS ENTRY DOORS AND
 SIDELITE ASSEMBLIES WHICH ARE LOCATED AT
 GRADE LEVEL. WILL THESE BE IMPACT RATED?
  
 5) A WRITTEN STORM PANEL STORAGE AND
 INSTALLATION PLAN MUST BE SUBMITTED AND
 APPROVED BY THE BUILDING OFFICIAL.
  
 6) THE ENERGY CALCULATIONS ARE NOT
 CORRECT. THE SQFT AREAS LISTED DO NOT
 CORRESPOND WITH THE PLANS FOR TOTAL
 CONDITIONED AREA, UNDER ATTIC, ETC.
 IDENTIFY EACH MODEL ON THE ENERGY CALCS.
 WITH THE CORRESPONDING DESIGNATION THAT
 IS LISTED ON THE PLANS.
  
 7)THE PRODUCT APPROVAL FOR THE UNCLIPPED
 MULLIONS EXPIRES ON 5-1-03 AND THE ONE
 FOR THE CLIPPED MULLIONS EXPIRED ON
 5-30-02. NEITHER ONE IS APPROVED FOR
 USE AS PART OF AN IMPACT RESISTANT
 ASSEMBLY.
  
 8) SUBMIT PRODUCT APPROVAL FOR OUTSWING
 DOOR WITH ONE SIDELITE. THE ONES THAT
 WERE SUBMITTED ARE EXPIRED AND HAVE THE
 COVERSHEET FOR A DOUBLE OUTSWING DOOR.
  
 9) SUBMIT A SIGNED AND SEALED COPY OF
 THE SOIL REPORT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202
 9) S

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-12-11 Cont ID  
Sent By rmcdouga Date 2002-12-11 Time 09:11 Rev Time 6.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-12-11 00:00:00BUILDING DENIED
  
 NOTE: IMPACT FEES, SURVEY AND NOTICE OF
 COMMENCEMENT WILL BE REQUIRED FOR EACH
 BUILDING APPLIED FOR UNDER THE MASTER.
  
 1) INDICATE THE INTERNAL PRESSURE
 COEFFICENT ON C1. IT IS + OR - 0.18 FOR
 AN ENCLOSED STRUCTURE.
  
 2) PLEASE REVISE PLAN NOTE #11 ON C1,
 HURRICANE SHUTTERS ARE REQUIRED IN WPB,
 WHICH IS IN THE WIND BORN DEBRIS REGION,
 BUT NOT IN THE HVHZ. FBC 1606.1.4
  
 3)REVISE THE NOTES ON A3 ON THE REQUIRED
 APPROVED CLOSERS TO REFERENCE THE 2001
 FLORIDA BUILDING CODE.
  
 4) THE C LABEL DESIGNATIONS FOR FIRE
 RATED DOORS IS NO LONGER USED. SEE FBC
 705.1.3.2.1. SPECIFY 3/4 HOUR RATED FIRE
 DOORS ON PLANS WHERE REQUIRED PER FBC
 TABLE 705.1.2.
  
 5) THE WALL BELOW AND THE UNDERSIDE OF
 THE STAIRS ARE REQUIRED TO HAVE A ONE
 HOUR FIRE RATING. PLEASE INDICATE THIS
 ON FLOOR PLAN ON A3.
  
 6) THE CLOSET DOORS IN BEDROOMS #2 OF
 UNIT A, #3 OF UNIT D AND #3 OF UNIT C
 MUST PROVIDE A 32"NOMINAL CLEAR OPENING
 IN ORDER FOR THE USER TO PASS THROUGH TO
 ACCESS THE CONTENTS IS REQUIRED BY THE
 FAIR HOUSING ACT.
  
 7) THE DOUBLE DOORS TO THE DEN IN UNITS
 D AND A, MUST HAVE BOTH LEAFS ACTIVE OR
 THE ONE ACTIVE LEAF MUST PROVIDE A 32"
 CLEAR OPENING PER FAIR HOUSING ACT.
 INDICATE ON THE PLANS ON SHEETS A3 AND
 A4 & FOR OPTIONS Q2,Q3,D2,D3 ON A17 AND
 A18.
  
 8) THE MASTER BATH W/C OPTIONS Q1,S1,M2
 AND D1 ON SHEETS A17 AND A18 DO NOT
 COMPLY WITH FAIR HOUSING REQUIREMENTS.
  
 9) INDICATE THE CLEAR FLOOR SPACE
 DIMENSIONS AT THE BATHROOM FIXTURES WITH
 SHADED AREAS.
  
 10) THE PROJECT TITLE BLOCK ON THE PLANS
 ARE INCORRECT. PLEASE REVISE.
  
 11)ON SHEET A4 SECTIONS A,B,C ARE TAGGED
 AS BEING LOCATED ON A6, BUT ARE ON A7.
 SECTIONS 1,3 AND 5 ARE MARKED AS BEING
 ON A7, BUT ARE LOCATED ON A8. PLEASE
 CORRECT.
  
 12) SHEET A5 AND A6 HAVE A NOTE THAT
 INDICATES STUCCO OVER CONCRETE BLOCK AT
 THE EXTERIOR WALLS ABOVE THE GARAGE,
 WHICH ARE WOOD FRAME. PLEASE CORRECT.
  
 13) REVISE THE HANDRAIL AND PARTY WALL
 NOTES ON A7 TO REFERENCE THE 2001 FBC.
  
 14) REVISE THE ATTIC VENTILATION NOTES
 ON A10 TO REFERENCE THE 2001 FBC.
  
 15) PROVIDE A DETAIL OF THE STAIRS THAT
 INDICATES THE RISER AND TREAD DIMENSIONS
 AND SHOWS COMPLIANCE WITH FBC 1007.3.
  
 16) PROVIDE DETAILS OF THE INTERIOR
 GUARDRAIL AT THE TOP OF THE STAIRS AND
 IN FRONT OF THE ELEVATOR. INDICATE THE
 ATTACHMENTS, DIMENSIONS, ETC. SEE FBC
 1015.
  
 17) THE KEY PLANS AND INSTALLATION
 SCHEDULES FOR THE STORM PANELS DO NOT
 CORRESPOND WITH THE PLANS. A WRITTEN
 STORM PANEL STORAGE AND INSTALLATION
 PLAN MUST BE SUBMITTED AND APPROVED BY
 THE BUILDING OFFICIAL.
  
 18) THE ENERGY CALCULATIONS ARE REQUIRED
 TO BE SIGNED BY THE OWNER/AGENT. THE
 CONDITIONED FLOOR AREA ON THE ENERGY
 CALCS. DOES NOT MATCH THE CONDITIONED
 AREA GIVEN ON THE PLANS.
  
 19) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - OUTSWING DOORS W/SIDELITES (EXPIRED)
 - STRUCTURAL MULLIONS (EXPIRED)
 - SLIDING GLASS DOORS (BOTH ARE EXPIRED)
 - OVERHEAD GARAGE DOOR(DRAWING SUBMITTED
 IS FOR DOOR WITH MAXIMUM WIDTH OF 9')
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop E ELECTRICAL
Rev No 6 Status F Date 2004-07-12 Cont ID  
Sent By dpalmer Date 2004-07-12 Time 11:38 Rev Time 0.33
Received By dpalmer Date   Time   Sent To  
Notes
2004-07-12 00:00:00*** UNSAT ***
  
 PLANS/ REVISIONS BROUGHT IN, C.O> ISSUED
 .

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2003-06-30 Cont ID  
Sent By csiegber Date 2004-07-06 Time 10:11 Rev Time 0.50
Received By dpalmer Date 2003-06-30 Time 16:23 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-05-08 Cont ID  
Sent By shernand Date 2003-06-26 Time 10:55 Rev Time 0.75
Received By dpalmer Date 2003-05-08 Time 10:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2003-04-03 Cont ID  
Sent By dpalmer Date 2003-04-03 Time 11:54 Rev Time 0.25
Received By dpalmer Date 2003-04-03 Time 11:54 Sent To  
Notes
2003-04-03 00:00:00************ UNSAT ***************
  
 PLEASE SEE NOTES PREVIOUSLY DONE ON
 3/19/03 BY BILL TROBAUGH. THIS WAS PUT
 IN AS PROVISO BY MISTAKE. PLEASE NOTE,
 PLAN REVIEW/CHECK MUST HAVE ALL COMMENTS
 DONE.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-03-19 Cont ID  
Sent By btrobaug Date 2003-03-19 Time 11:06 Rev Time 1.00
Received By btrobaug Date 2003-03-18 Time 17:43 Sent To P
Notes
2003-03-19 00:00:00PROVISO
 ~~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE CORRECT THE FOLLOWING AND
 RESUBMIT FOR REVIEW PRIOR TO ROUGH
 ELECTRICAL INSPECTIONS.
  
 1} NOTE #18 ON SHEET C1 MAKES A
 REFERENCE TO "ALL DWELLING ROOM
 RECEPTACLES" BEING ON ARC FAULT
 BREAKERS,WHICH CONTRADICTS THE NOTE ON
 A-16.PLEASE CORRECT TO SHOW THE INTENT
 OF THE ARCHITECT.
  
 2} THERE ARE NO MAIN DISCONNECTS SHOWN
 ON THE RISER DIAGRAM AND PANELS ARE
 SWOWN AS MLO.PLEASE
 CLARIFY.(DISCONNECTS ARE SHOWN ON SHEET
 A-10 OF THE DRAWING).
  
 3} THE LIVING ROOM IN UNIT "A",AND THE
 GREAT RM IN UNIT "C" HAVE RECEPTACLE
 SPACING NOT IN COMPLIANCE WITH 210-52,
 PLEASE CORRECT.
  
 4} THE ELEVATOR OCP ON PANELS "C&D" DO
 NOT MATCH THE THE ELEVATOR SPEC'S FOR
 30AMPS.PLEASE CLARIFY AND RECALCULATE
 THE PANEL LOADS IF NECESSARY.
  
 5} PLEASE NOTE THAT MOST OF THE
 EQUIPMENT DISCONNECTS ARE NOT SHOWN TO
 COMPLY WITH 110-26.PLEASE CHANGE THE
 DRAWINGS TO SHOW COMPLIANCE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-12-05 Cont ID  
Sent By sthyng Date 2003-03-18 Time 08:25 Rev Time 1.00
Received By btrobaug Date 2002-12-02 Time 18:08 Sent To FIRE
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2003-07-08 Cont ID  
Sent By nmccray Date 2003-07-08 Time 11:19 Rev Time 0.00
Received By nmccray Date 2003-07-08 Time 11:18 Sent To B
Notes
2003-07-08 00:00:00REVISION 6-25-03 NAM

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-04-18 Cont ID  
Sent By nmccray Date 2003-04-18 Time 09:17 Rev Time 0.00
Received By nmccray Date 2003-04-18 Time 09:17 Sent To  
Notes
2003-04-18 00:00:00PLEASE SEE NOTES PREVIOUSLY DONE BY
 CAPT. MIKE CARSILLO ON 12/05/02.
  
 NATE MCCRAY, CAPTAIN
 659-8096, 8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-12-05 Cont ID  
Sent By btrobaug Date 2002-12-05 Time 13:32 Rev Time 0.00
Received By mcarsill Date 2002-12-05 Time 14:14 Sent To  
Notes
2002-12-05 00:00:001) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO, DURING, AND AFTER CONSTRUCTION.
  
 2) BUILDING ADDRESSES REQUIRED ON UNITS.
  
 3) PORTABLE FIRE EXTINGUISHERS REQUIRED.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2004-07-06 Cont ID  
Sent By csiegber Date 2004-07-06 Time 10:11 Rev Time 0.00
Received By csiegber Date 2004-07-06 Time 10:11 Sent To E
Notes
2004-07-06 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-01-28 Cont ID  
Sent By csiegber Date 2004-01-28 Time 14:57 Rev Time 0.00
Received By csiegber Date 2004-01-28 Time 14:57 Sent To M
Notes
2004-01-28 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-06-26 Cont ID  
Sent By shernand Date 2003-06-26 Time 10:55 Rev Time 0.00
Received By shernand Date 2003-06-26 Time 10:55 Sent To E
Notes
2003-06-26 00:00:00DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-06-23 Cont ID  
Sent By shernand Date 2003-06-23 Time 12:38 Rev Time 0.00
Received By shernand Date 2003-06-23 Time 12:38 Sent To B
Notes
2003-06-23 00:00:00RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-06-16 Cont ID  
Sent By shernand Date 2003-06-16 Time 13:51 Rev Time 0.00
Received By shernand Date 2003-06-16 Time 13:51 Sent To P
Notes
2003-06-16 00:00:00COMM BOARD #63

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-05 Cont ID  
Sent By shernand Date 2003-05-05 Time 12:36 Rev Time 0.00
Received By shernand Date 2003-05-05 Time 12:36 Sent To  
Notes
2003-05-05 00:00:00COMM BOARD #54

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-24 Cont ID  
Sent By sthyng Date 2003-03-18 Time 08:25 Rev Time 0.00
Received By sthyng Date 2003-03-18 Time 08:25 Sent To  
Notes
2003-03-18 00:00:00COMM BOARD #56

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2004-02-11 Cont ID  
Sent By pkrauss Date 2004-02-11 Time 07:25 Rev Time 0.33
Received By pkrauss Date 2004-02-11 Time 07:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2003-07-07 Cont ID  
Sent By csiegber Date 2004-01-28 Time 14:58 Rev Time 0.30
Received By pkrauss Date 2003-07-07 Time 12:52 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status N Date 2003-06-23 Cont ID  
Sent By kstevens Date 2003-07-02 Time 18:25 Rev Time 0.45
Received By pkrauss Date 2003-06-23 Time 14:31 Sent To  
Notes
2003-06-23 00:00:00CALLED CONTRACTOR ADDITIONAL PLANS WHERE
 SUBMITTED BY MISTAKE.PLANS APPROVED
 5-15-03 ARE THE APPROVED SET. ADDITIONAL
 PLANS TO BE SENT BACK WITH CONTRACTOR.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-05-15 Cont ID  
Sent By pkrauss Date 2003-05-15 Time 13:14 Rev Time 0.35
Received By pkrauss Date 2003-05-15 Time 13:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-04-03 Cont ID  
Sent By pkrauss Date 2003-04-03 Time 11:09 Rev Time 0.40
Received By pkrauss Date 2003-04-03 Time 10:21 Sent To  
Notes
2003-04-03 00:00:00DENIED:2ND PLAN CHECK UNITS A,B,C & D
  
 COMMENTS FROM PLAN CHECK DATED 11-30-02
 NOT ADDRESSED.
  
 1.INDICATE OUTSIDE AIR REQUIREMENT BY
 NATURAL 2001 FBC(M) 402.2 OR MECHANCIAL
 TABLE 403.3.PROVIDE CALCULATIONS.
  
 2.MISSING DUCT SIZE FROM MODEL C THE
 MASTER BEDROOM SUPPLY DUCT.8"?
  
 3.SMOKE DETECTORS SHALL BE INSTALLED
 SUPPLY SYSTEMS WITH A DESIGN CAPACITY
 GREATER THAN 2,000 CFM, IN THE SUPPLY
 AIR DUCT. 2001 FBC(M) 606.2.1OR
 UPON ACTIVATION, THE SMOKE DETECTORS
 SHALL SHUTDOWN THE AIR DISTRIBUTION
 SYSTEM. 2001 FBC(M) 606.4
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-11-30 Cont ID  
Sent By hmoser Date 2002-11-30 Time 11:41 Rev Time 1.00
Received By hmoser Date 2002-11-30 Time 11:41 Sent To E
Notes
2002-11-30 00:00:00PLAN DENIED
 1) DESIGN TO 2001 MECHANICAL CODE
 2) VARIFY TYPE OF VENTILATION USED FOR
 FRESH AIR NATURAL SECTION 402 OR
 MECHANICAL SECTION 403
 3) NEED CALCULATION FOR TYPE OF
 VENTILATION USED
 4) REFER TO SECTION 601.4 BALANCED
 RETURN AIR
 5)REFER TO SECTION 606 SMOKE DETECTION
 SYSTEM CONTROL
 6) SOME DUCT SIZE MISSING ON PLANS
 7) CONDENSATE LINE MUST TERMINATE 12IN.
 FROM BUILDING FBC.SECTION 1503.4.4
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 5 Status P Date 2003-07-02 Cont ID  
Sent By kstevens Date 2003-07-02 Time 18:25 Rev Time 0.50
Received By kstevens Date 2003-07-02 Time 18:24 Sent To M
Notes
2003-07-02 00:00:00REVISION OK - CHANGED UNIT LAYOUTS

Review Stop P PLUMBING
Rev No 4 Status P Date 2003-06-23 Cont ID  
Sent By dpalmer Date 2003-06-30 Time 16:23 Rev Time 0.33
Received By kstevens Date 2003-06-23 Time 15:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2003-06-02 Cont ID  
Sent By shernand Date 2003-06-16 Time 13:52 Rev Time 0.33
Received By kstevens Date 2003-06-02 Time 15:07 Sent To  
Notes
2003-06-02 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING.
  
 A) COMMENT FROM 1ST AND 2ND REVIEW NOT
 ADDRESSED.
 1) SHT A-16 CARRISA MODEL, BEGONIA MODEL
 & DATURA MODEL, SANT DRAIN REQUIRED TO
 BE MINIMUM OF 3" UP TO WHERE THE TUB IS
 TAKEN OFF BRANCH DRAIN. TABLE 909.3 &
 SECTION 909.1 WET VENT. SINCE THIS IS
 A MASTER MODEL, IT SHALL BE CORRECTED TO
 MEET CODE REQUIREMENTS.
 SEE FLORIDA STATUTE 553.80(2)(B) ATTACH-
 ED FOR IMFORMATION CONCERNING 4 TIMES
 THE FEE AFTER 3RD REVIEW.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-03-24 Cont ID  
Sent By kstevens Date 2003-03-24 Time 15:56 Rev Time 1.00
Received By kstevens Date 2003-03-24 Time 15:55 Sent To  
Notes
2003-03-24 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FHA-98 AMENDED DESIGN MANUAL
  
 1) SHT A-3 CARISSA MODEL, FLOOR PLAN
 SHOWS BATH #3 WITH A W/C, LAV, & SHOWER.
 SHT A-16 SANT. RISER DIAGRAM SHOWS W/C,
 LAV, & A BAR SINK. PLEASE CLAIRFY.
 2) SHT A-16 CARRISA MODEL, BEGONIA MODEL
 & DATURA MODEL, SANT DRAIN REQUIRED TO
 BE MINIMUM OF 3" UP TO WHERE THE TUB IS
 TAKEN OFF BRANCH DRAIN. TABLE 909.3 &
 SECTION 909.1 WET VENT. (SEE 2ND FLOOR
 MASTER BATH FOR ALAMANDA MODEL)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-11-13 Cont ID  
Sent By btrobaug Date 2003-03-19 Time 11:06 Rev Time 1.00
Received By jleech Date 2002-11-13 Time 17:22 Sent To  
Notes
2002-11-13 00:00:00DENIED;
 PAGE A-16. PLUMBING RISER DIAGRAMS.
 UNIT "A" AND "B"
 1.MASTER W/C 3" WET VENT REQUIRED. SEE
 FBC PLUMBING TABLE 908.3.
 2.KITCHEN BRANCH. 2" DRY VENT NOT
 REQUIRED.
 3.RISERS ARE GOING TO WRONG APARTMENTS.
 "A" SHOULD GO TO "C" ECT.
 4.FLOOR PLAN SHOWS L.T.S ON FIRST FLOOR
 NONE SHOWN ON RISER DIAGRAMS.
 UNITS "C" AND "D"
 1.RISER DIAGRAM SHOWS 2 WASHERS FLOOR
 PLAN SHOWS ONE.
 2.MASTER W/C WET VENT REQUIRED TO BE 3"
 SEE TABLE 908.3.
  
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT.8369

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2003-07-10 Cont ID  
Sent By rmcdouga Date 2003-07-10 Time 16:05 Rev Time 3.00
Received By rmcdouga Date 2003-07-10 Time 16:05 Sent To  
Notes
2003-07-10 00:00:00REVISION TO CHANGE THE 1ST AND 2ND FLOOR
 LEFT SIDE UNITS TO BEGONIA AND DATURA
 FLOOR PLANS IS OK. REVISED UNITS ARE
 MIRROR IMAGE OF RIGHT SIDE UNITS. SQUARE
 FOOTAGE AND FOOTPRINT DID NOT CHANGE.

Review Stop Z ZONING
Rev No 2 Status P Date 2003-06-19 Cont ID  
Sent By mmclean Date 2003-06-19 Time 10:29 Rev Time 1.00
Received By mmclean Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2003-05-19 Cont ID  
Sent By sgraham Date 2003-05-19 Time 12:37 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
2003-05-19 00:00:00ZONING DOES NOT LOOK AT MASTERS!!!!
 PLEASE DO NOT PUT ANY MASTERS PLANS
 TOO ZONING.