| Plan Review Stops For Permit 02102207 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
N |
Date |
2003-06-10 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-06-06 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-06-06 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2003-06-06 00:00:00 | SEE COMMENTS UNDER THE INDIVIDUAL | | | COTTAGE BUILDING PERMIT NUMBERS 03050050 | | | TO 03050057. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-04-24 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-04-24 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-04-24 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2003-04-24 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 1/3/03: | | | | | | 1) THIS COMMENT HAS NOT BEEN ADDRESSED. | | | FBC* 104.2.4SITE SURVEY.A SIGNED | | | AND SEALED SURVEY DRAWING PREPARED BY A | | | QUALIFIED SURVEYOR IS REQUIRED (REF: | | | 472.025(1) FL. STATUTES.). THE SUBMITTED | | | SURVEY SHEET IS FOR A DELRAY BEACH | | | LOCATION (???). | | | | | | 3) INFORMATIVE: | | | A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 4) INFORMATIVE: | | | IMPACT FEES MUST BE PAID TO PALM BEACH | | | COUNTY, THE PLANS STAMPED BY THEM AND A | | | COPY OF THE RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH CONSTRUCTION SERVICES | | | DEPARTMENT BEFORE A BUILDING PERMIT CAN | | | BE ISSUED. | | | | | | 5) FBC 11-4.1.2EACH OF THE BUILDINGS | | | SHALL BE SERVED BY AT LEAST ONE | | | ACCESSIBLE ROUTE FROM THE ACCESSIBLE | | | PARKING AND THE BUS STOP.ACCEPTABILITY | | | OF THESE PLANS IS CONTINGENT UPON THE | | | CIVIL/SITE PLANS, PERMIT# 02102208, | | | BEING PERMITTED. NOTE THAT THE SUBMITTED | | | SITE PLAN (SHEET A6-1.1) DOES NOT SHOW | | | A PATH TO THE ENTRANCE OF COTTAGE #7. | | | | | | 6) THIS COMMENT HAS NOT BEEN ADDRESSED. | | | FBC 13-103.0ENERGY CODE COMPLIANCE | | | SHALL BE DEMONSTRATED BY SUBMITTAL OF | | | APPROPRIATE CODE COMPLIANCE FORMS | | | | | | 7) PRODUCT APPROVALS: DOOR, WINDOW, ROOF | | | (A) ASPHALT SHINGLE PRODUCT APPROVAL | | | NOA# 00-0105.02 EXPIRED ON 4/22/03. | | | SUBMIT A VALID PRODUCT APPROVAL. | | | (B) THE SUBMITTED COPY OF STEELCRAFT | | | MANUF. 98/99 RIM EXIT STEEL DOOR PRODUCT | | | APPROVAL NOA# 01-1203.11 IS MISSING TEXT | | | SHEETS 2 AND 3 (SPECIFIC AND GENERAL | | | CONDITIONS), AND SOME OF THE DRAWING | | | SHEETS.SUBMIT A COMPLETE PRODUCT | | | APPROVAL. | | | (C) THE SUBMITTED COPY OF STEELCRAFT | | | MANUF. F, M FRAME STEEL DOOR PRODUCT | | | APPROVAL NOA# 01-0129.12 IS MISSING TEXT | | | SHEETS 2 AND 3 (SPECIFIC AND GENERAL | | | CONDITIONS), AND SOME OF THE DRAWING | | | SHEETS.SUBMIT A COMPLETE PRODUCT | | | APPROVAL. | | | (D) NOT USED | | | (E) THE DRAWING SHEETS OF THE SUBMITTED | | | COPIES OF ARCH ALUMINUM STOREFRONT DOOR | | | PRODUCT APPR. NOA# 01-0919.02 ARE POORLY | | | REPRODUCED.SUBMIT LEGIBLE COPIES. | | | COPIES OF MIAMI-DADE PRODUCT APPROVALS | | | CAN BE PRINTED FROM THEIR WEBSITE,WWW. | | | MIAMIDADE.GOV/BUILDINGCODE/PC-SEARCH.HTM | | | (F) THE SUBMITTED 2 PAGE COPY EXTRACT OF | | | THE 48 PAGE GAF MODIFIED BITUMEN ROOF | | | PRODUCT APPROVAL NOA# 00-0331.09 DOES | | | NOT INCLUDE A STATEMENT OF THE MAXIMUM | | | DESIGN PRESSURE AND STATES THAT "ALL | | | GENERAL AND SYSTEM LIMITATIONS SHALL | | | APPLY".SUBMIT COPIES OF THE SHEETS | | | WHICH STATE THE GENERAL AND SYSTEM | | | LIMITATIONS AND THE MAX DESIGN PRESSURE. | | | COPIES OF MIAMI-DADE PRODUCT APPROVALS | | | CAN BE PRINTED FROM THEIR WEBSITE,WWW. | | | MIAMIDADE.GOV/BUILDINGCODE/PC-SEARCH.HTM | | | | | | 10) FBC* TABLE 2306.1STRUCTURAL NOTES, | | | SHEET STR-GN, PLYWOOD ROOF DECKING | | | NOTE 3B.THE REVISION MADE , PER THE G. | | | D. KLIEGER COMMENT RESPONSE LETTER, IS | | | NOTED.THE * FOLLOWING THE REFERENCE TO | | | FBC MEANS CITY OF WPB AMENDMENTS TO THE | | | FLORIDA BUILDING CODE (SEE KEY ABOVE). | | | THE AMENDED TABLE REQUIRES THE PERIMETER | | | ZONE AT THE GABLE END TO HAVE NAILS | | | SPACED AT 4"O.C. MAXIMUM, FOR A DISTANCE | | | OF 5 FT (NOT 4 FT) FROM THE EDGE OF THE | | | ROOF. | | | | | | 15) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-01-06 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-01-06 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-01-06 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2003-01-06 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) FBC* 104.2.4A SIGNED AND SEALED | | | SURVEY DRAWING IS REQUIRED. | | | | | | 2) FL. ADMIN. CODE 61G1-16.003EACH | | | ARCHITECTURAL PLAN SHEET SHALL BE SIGNED | | | PERSONALLY, NOT SIGNATURE STAMPED. | | | | | | 3) INFORMATIVE: | | | A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 4) INFORMATIVE: | | | IMPACT FEES SHALL BE PAID TO PALM BEACH | | | COUNTY, THE PLANS STAMPED BY THEM AND A | | | COPY OF THE RECEIPT SUBMITTED TO THE | | | CITY OF WEST PALM BEACH CONSTRUCTION | | | SERVICES DEPARTMET BEFORE A BUILDING | | | PERMIT CAN BE ISSUED. | | | | | | 5) FBC 11-4.1.2EACH OF THE BUILDINGS | | | SHALL BE SERVED BY AT LEAST ONE | | | ACCESSIBLE ROUTE FROM THE ACCESSIBLE | | | PARKING.ACCEPTABILITY OF THESE PLANS | | | IS CONTINGENT UPON UPON THE CIVIL/SITE | | | PLANS, PERMIT# 02102208, BEING PERMITTED | | | NOTE THAT THE SUBMITTED SITE PLAN (SHEET | | | A7-1.1) DOES NOT SHOW A PATH TO THE | | | ENTRANCE OF COTTAGE #7. | | | | | | 6) FBC 13-103.0ENERGY CODE COMPLIANCE | | | SHALL BE DEMONSTRATED BY SUBMITTAL OF | | | APPROPRIATE CODE COMPLIANCE FORMS | | | | | | 7) SUBMIT PRODUCT APPROVALS FOR THE | | | ROOFING, EXTERIOR DOORS AND WINDOWS. | | | | | | 8) FBC* 104.2NO FOUNDATIONS ARE SHOWN | | | FOR THE COURTYARD ALUMINUM RAILING AND | | | GATE.A SEPARATE PERMIT APPLICATION | | | WILL BE REQUIRED. | | | | | | 9) FOUNDATION PLAN SHEET S-7.01 HAS | | | 'MF-16' ANNOTATION AT THE MONOLITHIC | | | FOOTING.THIS SHOULD BE 'WF-16' TO | | | CORRELATE WITH THE FOOTING SCHEDULE. | | | | | | 10) FBC* TABLE 2306.1STRUCTURAL NOTES, | | | SHEET STR-GN, PLYWOOD ROOF DECKING.THE | | | PERIMETER ZONE AT THE GABLE ENDS SHALL | | | HAVE NAILS SPACED AT 4"O.C. MAXIMUM, TO | | | A DISTANCE OF 5 FEET (NOT 24") FROM THE | | | EDGE OF THE ROOF. | | | | | | 11) STRUCTURAL NOTES, SHEET STR-GN, WOOD | | | TRUSS NOTE 6.IT IS NOTED THAT THE | | | TRUSS DESIGN ENGINEER IS TO PROVIDE THE | | | WIND UPLIFT REACTIONS.THE PERMIT | | | CANNOT BE ISSUED UNTIL THE REACTIONS ARE | | | SPECIFIED ON THE PLANS FOR CROSS | | | REFERENCE AGAINST THE PROPOSED TRUSS | | | ANCHORS AND STRAPS. | | | | | | 12) FBC 410.2.2 FIRE SEPARATION.THE | | | LAUNDRY ROOM SHALL BE SEPARATED FROM | | | OTHER ROOMS BY 1-HOUR RATED WALLS AND | | | 3/4-HOUR DOORS.SHEET A7-2.1 SHOWS | | | PARTITION TYPES C AND I WHICH ARE NON- | | | RATED. | | | | | | 13) FBC 2309.6ATTIC ACCESS.THE ATTIC | | | ACCESS PANELS SHOWN ON SHEET A7-11.1 ARE | | | NOT DIMENSIONED.ATTIC ACCESS OPENINGS | | | SHALL BE NOT LESS THAN 20X36 INCHES. | | | | | | 14) FBC 2405.2THE GLAZED PANEL | | | ADJACENT TO THE STAFF OFFICE DOOR IS | | | MARKED AS REF *H.NO DETAILS ARE GIVEN | | | IN THE SCHEDULE ON SHEET A7-10.1, WHICH | | | ONLY GOES UP TO REF F.THE GLAZED PANEL | | | IS IN A 'HAZARDOUS LOCATION' AND IS | | | REQUIRED TO BE SAFETY GLASS SATISFYING | | | THE REQUIREMENTS OF THE CONSUMER PRODUCT | | | SAFETY COMMISSION 16, CODE OF FEDERAL | | | REGULATIONS, PART 1201 (CPSC 16-CFR, | | | PART 1201).SUBMIT DETAILS TO | | | DEMONSTRATE COMPLIANCE. | | | | | | 15) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
N |
Date |
2003-10-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-03 |
Time |
07:18 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-10-03 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2003-10-03 00:00:00 | PLEASE SEE COMMENTS UNDER EACH INDIVID- | | | -UAL COTTAGE PERMITS. | | | 03050050-51,52,53,54,55,57 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-05-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-15 |
Time |
12:07 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2003-05-15 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2003-05-15 00:00:00 | ************ UNSAT ************** | | | | | | PLEASE SEE COMMENTS FROM PREVIOUS REVIEW | | | | | | 1)NOTE: PLEASE SEE RISER DIAGRAM,THE | | | COTTAGE UNIT #`S DO NOT CORRELATE WITH | | | UNIT #`S SHOWN ON UPPER LEFT HAND | | | CORNER OF PANEL SCHEDULE? | | | PLEASE ALSO CLARIFY WHY THERE ARE TWO- | | | -SETS OF 250 MCM FOR A 200A MCB PANEL | | | AND CLARIFY HOW TWO 250MCM WILL FIT INTO | | | A MCB? IF MAC ADAPTERS ARE TO BE USED | | | PLEASE ADD NOTE. 215-5 | | | | | | 2)NOTE: PLEASE SEE LOAD CALCULATIONS, | | | ON PANEL SCHEDULE. LOADS ARE INCOMPLETE | | | FOR PANEL. SHOWN MOSTLY AS BLANK. | | | THE LOAD CALCULATIONS ON BOTTOM RIGHT | | | HAND CORNER OF SHEET E7-4.01 ARE FOR | | | SFR/DWELLING. PLEASE NOTE, CALCS NEED | | | TO BE DONE UNDER COMM USE AND SHOW ALL | | | CONTINUOUS LOADS AT 125%, WHICH WAS | | | STARTED ON PANEL SCHEDULE? | | | 215-5,215-3, 230-42,220-10,11,13,03,, | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. PLEASE REMOVE OLD/VOIDED SHEETS | | | AND INSERT NEW INTO COMPLETE SETS FOR | | | REVIEW AND STAMPING. | | | | | | PLEASE SEE LETTER ATTACHED FOR DESIGN | | | OF RECORD. FS 553.80(2)(B) | | | | | | PLEASE CALL IF THERE ARE ANY QUESTIONS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-03-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-28 |
Time |
04:57 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-03-28 |
Time |
04:39 |
Sent To |
|
|
| Notes |
| 2003-03-28 00:00:00 | ************* NOTES/UNSAT ********** | | | #6,8,11,13 | | | 1)NOTE: PLEASE SEE RISER DIAGRAM/PANEL | | | SCHEDULE AND LOAD CALCUALTIONS. | | | LOAD CALCS SHOW PANEL TO BE 250 MLO W/ | | | 250A MCB, PANEL SCHEDULE SHOWS 200A MCB, | | | PLEASE CLARIFY AND CORRELATE. | | | | | | 2)NOTE: PLEASE CLARFIY LOAD CALCAULTIONS | | | LOAD CALCS ON PANEL SCHEDULE ARE SHOWN | | | AS COMM AND OTHER LOAD CALCS SHOWN AS | | | RESIDENTIAL?? | | | MIXED USE | | | | | | 3)NOTE: PLEASE NOTE, PLANS UNDER THIS | | | PERMIT # SHOWS PANEL 6L/A ON RISER AND | | | 7L/A ON PANEL SCHEDULE AND SHOWS TYP FOR | | | 9,10 AND 11. TITLE BLOCK ON RIGHT SHOWS | | | TYPICAL FOR #`S 6,8,11,13? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER. | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | [email protected] | | | ********NOTES FOR 7,9,10,12 ******* | | | | | | PLEASE SEE OTHER NOTES FOR COTTAGES | | | SOME NOTES ARE THE SAME. | | | | | | 1)NOTE: PLEASE CLARFIFY HOW/WHERE | | | SERVICE SIZE CHANGES? RISER SHOWS | | | SEC`S CHANGING TO TWOS SETS OF 250 MCM | | | FOR 8,9,12 &13? | | | PLEASE NOTE, TWO SETS OF 250MCM ARE | | | RATED FOR 510A`S? PLEASE CLARIFY. | | | PANELS ARE SHOWN AT 200A MC AND LOAD | | | CALCS AT BOTTOM SHOW 250 OCP FOR 250A | | | PANEL?? | | | PLEASE SEE TITLE BLOCK SHOWS TYPICAL | | | AS UNITS/ 7,9,10 &12 AND ABOVE PANEL, | | | TYPICAL SHOWS 8,12,13?? | | | | | | PLEASE CORRELATE. PLEASE SUBMIT FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-27 |
Time |
05:07 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2002-11-27 |
Time |
05:07 |
Sent To |
|
|
| Notes |
| 2002-11-27 00:00:00 | *************** UNSAT ***************** | | | | | | 1)NOTE:PLEASE PROVIDE CIRCUITING ON | | | PLANS AND CORRELATE WITH SUBMITTED OANEL | | | SCHEDULES. | | | | | | 2)NOTE: PLEASE CLARIFY SD`S SHOWN IN | | | A/C CLOSET? ARE THESE DUCT DETECTORS? | | | | | | | | | 3)NOTE: PLEASE NOTE, ARC FAULT PROTECT- | | | -ION REQ`D FOR BEDROOM CIRCUITS. 210-12 | | | PLEASE SHOW ON PANEL SCHEDULES. | | | | | | 4)NOTE: PLEASE NOTE, REQ`D BATH CIRCUTIT | | | (S) MISSING. 210-52D/ PLEASE LIST ON | | | PANEL SCHEDULE PER 210-11-C-3 | | | | | | 5)NOTE: PLEASE CLARIFY MCB IN PANELS | | | STILL MEETING 230-76/230-79 FOR MANUAL | | | MEANS OF DISC AND RATED FOR THE LOAD | | | SERVED. PLEASE NOTE, A SHUNT TRIP IS | | | PERMITTED, HOWEVER, MCB STILL NEEDS TO | | | MEET THE ABOVE. | | | | | | 6)NOTE: PLEASE COMPLETE LOAD CALCUALTION | | | -S. | | | | | | PLEASE NOTE, THIS IS A TYPICAL REVIEW | | | FOR ALL COTTAGE UNITS, AS PLANS WERE | | | SUBMITTED FOR ALL AS TYPICAL. | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2003-06-25 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-06-25 |
Time |
10:36 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-06-25 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2003-06-25 00:00:00 | PASSED : | | | 1. SEE PERMIT # 02102208 FOR UNDERGROUND | | | UTILITIES AND SITE WORKS. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2003-03-17 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-03-17 |
Time |
10:32 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-03-17 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2003-03-17 00:00:00 | FAILED: | | | 1. SEE REVIEW COMMENTS, PERMIT #02102208 | | | DATED 03-17-03. | | | IF ANY QUESTION PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2002-11-06 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-11-06 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
mamini |
Date |
2002-11-06 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2002-11-06 00:00:00 | FAILED: | | | 1. SEE REVIEW COMMENTS FOR PLAN REVIEW # | | | 02102208. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2003-04-24 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-04-24 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-04-24 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2003-04-24 00:00:00 | 1) HOW WILL THE COTTAGES BE LICENSED | | | UNDER STATE, COUNTY, AND CITY | | | REQUIREMENTS. | | | | | | 2) PLEASE INDICATE HOURS OF OPERATION | | | FOR THE COTTAGES. WILL THE COTTAGES BE | | | OPERATIONAL FULL TIME OR PART TIME. | | | | | | 3) IS THERE ANY COOKING PLANNED AT THE | | | COTTAGES THAT WOULD CREATE SMOKE OR | | | GREASE LADEN VAPORS. | | | | | | 4) SEPARATE PLANS AND PERMITS ARE | | | REQUIRED FOR THE INSTALLATION OF FIRE | | | SPRINKLER AND FIRE ALARM SYSTEMS. | | | | | | 5) A KNOX-BOX ENTRY SYSTEM WILL BE | | | REQUIRED. | | | | | | NATE MCCRAY, CAPTAIN | | | 659-8096, EXT 8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-01-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-01-10 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-01-10 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2003-01-10 00:00:00 | 1) HOW WILL THE COTTAGES BE LICENSED | | | UNDER STATE, COUNTY, AND CITY | | | REQUIREMENTS. | | | | | | 2) PLEASE INDICATE THE AGES OF THE | | | OCCUPANTS FOR THE COTTAGES AND | | | APPROPRIATE STAFF RATIO'S. | | | | | | 3) PLEASE PROVIDE A LIFE SAFETY PLAN | | | INDICATING OCCUPANT LOADS AND TRAVEL | | | DISTANCES TO EXITS. | | | | | | 4) PLEASE INDICATE HOURS OF OPERATION | | | FOR THE COTTAGES. WILL THE COTTAGES | | | BE OPERATIONAL FULL TIME OR PART TIME. | | | | | | 5) PLEASE PROVIDE A DATA BOX ON THE | | | TITLE PAGE INDICATING APPROPRIATE CODES | | | AND CONSTRUCTION TYPES FOR THE COTTAGES. | | | | | | 6) IS THERE ANY COOKING PLANNED AT THE | | | COTTAGES THAT WOULD CREATE SMOKE OR | | | GREASE LADEN VAPORS. | | | | | | 7) FIRE SPRINKLER HEADS APPEAR TO BE | | | MISSING FROM THE MIDDLE OF SOCIAL ROOM. | | | | | | 8) PROVIDE SEPARATE PLANS AND PERMITS | | | FOR THE INSTALLATION OF FIRE SPRINKLER | | | SYSTEM. | | | | | | 9) PROVIDE SEPARATE PLANS AND PERMITS | | | FOR THE FIRE ALARM SYSTEMS. | | | | | | 10) A KNOX-BOX ENTRY SYSTEM WILL BE | | | REQUIRED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-06-06 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-05 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2003-05-05 00:00:00 | COMM BOARD #12,PLANS NEXT TO CONF ROOM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-03-13 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-13 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-13 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2003-03-13 00:00:00 | COMM BOARD #46, RACK 1ST & 2ND SHELF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-06-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-06-10 |
Time |
10:33 |
Rev Time |
0.10 |
| Received By |
pkrauss |
Date |
2003-06-10 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2003-06-10 00:00:00 | PLANS APROVED ON INDIVIDUAL PERMITS | | | 5-10-03 PHK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-04-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-04-11 |
Time |
14:34 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-04-11 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2003-04-11 00:00:00 | DENIED:COTTAGES 6 - 13 | | | | | | 1.PLAN SHEET A6-2.1 & A7-2.1, LAUNDRY | | | ROOM NOW HAS A 1 HR SEPARATION.PLEASE | | | PROVIDE FIRE DAMPERS ON THE 14" X 14" | | | SUPPLY & RETURN DUCT THAT RUNS THROUGH | | | THIS DUCT. | | | | | | 2.DUCTS THAT ARE DO NOT EXCEED 100 SQ | | | INCHES ARE NOT REQUIRED TO HAVE FIRE | | | DAMPERS IF THE DUCT IS A MINIMUM OF | | | .0217" STEEL & HAS NO DUCT OPENINGS FOR | | | NOT LESS THAN 5 FT FROM RATED WALL. | | | PROVIDE MANUFACTURERS INSTALLATION | | | INSTRUCTIONS FOR THE FIRE DAMPER ON THE | | | JOBSITE AT TIME OF INSPECTION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-12-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-12-02 |
Time |
13:36 |
Rev Time |
3.00 |
| Received By |
pkrauss |
Date |
2002-12-02 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2002-12-02 00:00:00 | 1ST PLAN CHECK | | | DENIED:REVIEW COTTAGES #6,7,10,9,10, | | | 11,12, & 13. | | | | | | GAS DRYERS ARE INDICATED ON THE PLUMBING | | | PLAN.PROVIDE CALCULATIONS INDICATING | | | WHETHER THEY ARE INSTALLED IN A | | | "CONFINED" OR "UNCONFINED" SPACE. | | | | | | PLEASE NOTE AS PER 2001 FBC(M) 504.5, | | | DRYER INSTALLATIONS EXHAUSTING MORE THAN | | | 200 CFMSHALL BE PROVIDED WITH MAKEUP | | | AIR. | | | | | | FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | | SHALL COMPLY WITH 2001 FBC(M) 606.4.1, | | | DETECTOR SHALL ACTIVATE A VISIBLE AND | | | AUDIBLE SUPERVISORY SIGNAL AT A | | | CONSTANTLY ATTENDED LOCATION OR SHALL | | | ACTIVATEA VISIBLE & AN AUDIBLE SIGNAL | | | IN AN APPROVED LOCATION IN NORMALLY | | | OCCUPIED AREA. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-06-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-07 |
Time |
14:47 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-06-07 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2003-06-07 00:00:00 | PASSED/PROVISO | | | | | | | | | PLUMBING APPROVAL ONLY.SEPARATE PERMIT | | | REQUIRED FOR GAS. MORE INFORMATION WILL | | | BE REQUIRED WHEN APPLYING FOR PERMIT. | | | - SPECIFICATION SHEET FOR ADA ACCESSIBLE | | | SLIDING DOOR HARDWARE FOR DOOR AT ROOM | | | #104A REQUIRED AT TIME OF FINAL INSPECT- | | | ION. - |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-04-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-01 |
Time |
10:10 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-04-01 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2003-04-01 00:00:00 | PASSED/PROVISO | | | | | | PLUBMING ONLY - INFORMATIONS REQUIRED | | | FOR GAS TO BE SUBMITTED WITH APPLICATION | | | SPECIFICATION SHEET FOR ADA ACCESIBLE | | | SLIDING DOOR HARDWARE FOR DOOR AT RM. # | | | 104A NOT FOUND. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-01-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-12-16 |
Time |
15:16 |
Rev Time |
3.00 |
| Received By |
kstevens |
Date |
2002-12-16 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2002-12-16 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 11 | | | | | | 1) PER SECTION 11-9.1.1, ALL PUBLIC USE | | | AND COMMON USE AREAS ARE REQUIRED TO BE | | | DESIGNED AND CONSTRUCTED TO COMPLY WITH | | | SECTION 11-4 (ACCESSIBLE ELEMENTS AND | | | SPACES: SCOPE AND TECHNICAL REQUIREMENTS | | | ALL BATHROOM SHALL BE ACCESSIBLE AND | | | THE STAFF TOILET ROOM SHALL BE ACCESSI- | | | BLE. PLEASE PROVIDE DETAILS. | | | 2) SHT P6-2.01 DRINKING FOUNTAIN, SHOW | | | COMPLIANCE WITH SEC 11-4.1.3(10)(A), | | | PROVISIONS FOR THOSE WHO HAVE DIFFICULTY | | | BEND OR STOOPING. | | | 3) SEC. 11-4.13.9, DOOR HARDWARE. WHEN | | | SLIDING DOORS ARE FULLY OPEN, OPERATING | | | HARDWARE SHALL BE EXPOSED AND USABLE | | | FROM BOTH SIDES. | | | 4) SEC 11-4.13.11, DOOR OPENING FORCE. | | | THE MAXIMUM FORCE FOR PUSHING OR PULLING | | | OPEN A DOOR SHALL BE AS FOLLOWS PER | | | (2)(C) SLIDING OR FOLDING DOORS: 5 LBF | | | 5) SHT P6-3.01 DOMESTIC WATER RISER. | | | WATER HAMMER ARRESTORS REQUIRED BY 406.9 | | | FOR QUICK CLOSING VALVES, (WASH MACHINES | | | DISHWASHERS, & ICE MAKERS), SHALL BE LO- | | | CATED NEAR THE FIXTURES IN AN "EFFECTIVE | | | RANGE" NOT AT THE TOP OF THE DROP. PER | | | PDI-WH 201 AND MANUF. INSTALLATION IN- | | | STRUCTIONS. | | | 6) FOLLOWING COMMENTS FOR GAS PERMIT | | | APPLICATION REQUIREMENTS. | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | GAS CODE. | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | 3) LISTED WATER HEATERS SHALL BE IN- | | | STALLED IN ACCORDANCE WITH THEIR LISTING | | | AND THE MANUFACTURES INTSRUCTIONS. THERE | | | SHALL BE CLEARANCE FOR SERVICING HEATER. | | | 4) SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2001 | | | FUEL GAS CODE SEC 402.2. | | | 5) SHTS P6-2.01 & P6-3.02 GAS PLAN VIEW | | | & GAS RISER DIAGRAM, MANUAL SHUT OFF | | | VALVE TO BE UPSTREAM OF SOLENOID VALVE, | | | AND A UNION IS REQUIRED BETWEEN VALVES. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-06-06 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-06-06 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-01-13 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-01-13 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-01-13 00:00:00 | DENIED, NEED MINOR AMENDMENT AND THE | | | PLAT NEED TO BE RECORDED |
|
|