| Plan Review Stops For Permit 02102206 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
F |
Date |
2006-06-11 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-06-11 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2006-06-11 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2006-06-11 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6652 | | | E-MAIL: [email protected] | | | | | | REVISION SUBMITTED ON 4/24/06 | | | | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | F.S.= FLORIDA (STATE) STATUTE | | | | | | 1) FBC 1004.1.2 AND 1004.1.4 EXCEPTION 2 | | | SHEET A5-2.1, MEETING SPACE (RM 113/115) | | | FORMED BY UNITING ROOMS 113 AND 115 NOW | | | HAS AN OCCUPANCY OF 65 PERSONS.EVERY | | | ROOM WITH AN OCCUPANCY OF 50 OR MORE | | | PERSONS SHALL HAVE NOT LESS THAN TWO | | | EXIT ACCESS DOORS.AS THIS IS A | | | SPRINKLERED BUILDING, THE EXIT ACCESS | | | DOORS MUST BE AT A DISTANCE APART NOT | | | LESS THAN 1/3 THE MAXIMUM DIAGONAL | | | DIMENSION OF THE ROOM (THE REQUIRED | | | SEPARATION WOULD BE 1/2 THE DIAGONAL IF | | | THE BUILDING WERE NOT SPRINKLERED). | | | RELOCATE DOOR 113.A AND/OR 115.A TO | | | COMPLY.PLEASE NOTE THAT DOOR 109.B IS | | | NOT CONSIDERED AS AN EXIT ACCESS DOOR. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6652ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2006-02-19 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-02-19 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2006-02-19 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2006-02-19 00:00:00 | STRUCTURAL AND ARCHITECTURAL REVISION | | | SUBMITTED 1/27/06 FOR ADDITION OF TWO | | | COLUMNS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2006-01-05 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-01-05 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2006-01-05 |
Time |
07:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2005-11-21 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-11-21 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2005-11-21 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | REVISION SUBMITTED ON 9/15/05 FOR NEW | | | DESIGN FOR THE EDUCATION BUILDING. | | | | | | A) SUBMIT A PRODUCT APPROVAL LOUVER | | | DOORS (DOORS 105A, 106A AND 116A).ON | | | SHEET A5-10.1, THESE DOORS ARE CALLED UP | | | AS HOLLOW METAL ON THE DOOR SCHEDULE BUT | | | THE DOOR TYPE ELEVATION HAS A TITLE | | | 'HOLLOW METAL DOOR WITH LOUVER'.EITHER | | | SUBMIT A LOUVER DOOR PRODUCT APPROVAL OR | | | CLARIFY THAT THESE DOORS ARE NOT | | | LOUVERED | | | | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2005-08-17 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-08-17 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2005-08-17 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | REVISION SUBMITTED ON 7/6/05 FOR NEW | | | DESIGN FOR THE EDUCATION BUILDING. | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | F.S.= FLORIDA (STATE) STATUTE | | | | | | 1) FBC TABLE 704.2.4(FOOT NOTE 2) EXIT | | | ACCESS CORRIDORS IN EDUCATIONAL | | | OCCUPANCY.SHEET A5-2.1 THE INSTRUCTION | | | ROOMS DO NOT HAVE AT LEAST ONE EXIT DOOR | | | DIRECTLY TO THE OUTSIDE SO THE EXIT | | | ACCESS CORRIDOR (102) IS REQUIRED TO BE | | | ONE-HOUR FIRE-RATED.ALSO, THE ROOM | | | DOORS LEADING TO THE CORRIDOR ARE | | | REQUIRED TO BE 20-MINUTE FIRE-RATED. | | | AMEND THE PLANS AND DOOR SCHEDULE. | | | | | | 2) FBC 11-4.16.4WATER CLOSET GRAB BARS | | | SHEET A5-4.1.INTERIOR ELEVATIONS 3B, | | | 4B, 5B AND 6B SHOW THE LENGTH OF THE | | | SIDE GRAB BAR AS 3'-0".THIS SHOULD BE | | | 3'-6".AMEND THE PLANS. | | | | | | 3) FBC 1606.1.3UPLIFT AT HIP TRUSSES. | | | SHEET S-5.02 THE FOUR HIP TRUSSES ARE | | | MARKED WITH THE SAME TYPE 1 'TRUSS TO | | | WALL CONNECTION' THAT IS USED FOR THE | | | TYPICAL TRUSS.THE TRIBUTARY AREA FOR | | | THE HIP TRUSSES EXCEEDS THAT OF THE | | | TYPICAL TRUSS AND AND RESULTS IN AN | | | UPLIFT THAT EXCEEDS THE CAPACITY OF THE | | | PROPOSED USP HTA12 TRUSS ANCHOR.AMEND | | | THE PLAN OR SUBMIT CALCULATIONS TO | | | JUSTIFY THE PROPOSED TRUSS ANCHOR FOR | | | THIS APPLICATION. | | | | | | 4) FBC* 104.2 SHEET S-5.03, SECTION G. | | | THE PROPOSED USE OF 'THREADED ROD WITH | | | 4" EMBEDMENT' TO ATTACH THE 3X6'S @ 16" | | | O.C. TO THE 3X10 AND TO THE 3X6 LEDGER | | | IS NOT A RECOGNISED WOOD-TO-WOOD | | | CONNECTION DETAIL.AMEND/CLARIFY THIS | | | DETAIL. | | | | | | 5) SHEET A5-10.1, DOOR SCHEDULE.DOOR | | | 113A IS SHOWN AS BEING 5 FEET WIDE. | | | SHEET A5-2.1 DOES NOT INDICATE A 5 FOOT | | | WIDE DOOR.AMEND/CLARIFY THE PLANS. | | | | | | 6) SUBMIT PRODUCT APPROVALS FOR THE | | | GLASS BLOCK WINDOWS, THE SECTIONAL | | | OVERHEAD DOORS (DOORS 117B AND 118B)AND | | | THELOUVER DOORS (DOORS 105A, 106A AND | | | 116A). | | | | | | 7) TO EXPEDITE REVIEW OF A RESUBMITTAL | | | WHICH REQUIRES NEW PLANS IN ORDER TO | | | ADDRESS THE ABOVE COMMENTS, THE OLD | | | SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHOULD BE STAPLED/CLIPPED TO THE | | | REMAINING OLD SHEETS, TO FORM A SET OF | | | 'OLD/VOID SHEETS', FOR COMPARISON OF | | | REVISIONS WHEN REVIEWING THE RESUBMITTED | | | PLANS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2005-02-25 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-02-25 |
Time |
09:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2004-03-04 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-03-04 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-03-04 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2004-03-04 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | 61G1-16.004FL. ADMIN. CODE.ADD, TO | | | EACH ARCHITECTURAL SHEET, THE PRINTED | | | NAME AND LICENSE NUMBER OF JORGE GARCIA | | | AS THE ARCHITECT WHO SEALED THE PLANS. | | | THIS MAY BE DONE BY STAMP OR HANDWRITTEN | | | | | | THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-10-14 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-10-14 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2003-10-14 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 6/5/03: | | | | | | 3) THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 4) IMPACT FEES. THE PLANS SHALL BE TAKEN | | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | | STAMPED AT THAT OFFICE AND A COPY OF THE | | | PAID RECEIPT SUBMITTED TO THE CITY OF | | | WEST PALM BEACH DEPT OF CONSTRUCTION | | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | | | 6) FBC 13-103.1.1.1 AND 103.1.2SHEET 2 | | | OF THE SUBMITTED ENERGY CODE COMPLIANCE | | | FORMS SHALL BE SIGNED BY THE OWNER (OR | | | THE PROJECT ARCHITECT, OR OTHER | | | AUTHORIZED AGENT DESIGNATED BY THE | | | OWNER) TO CERTIFY COMPLIANCE WITH THE | | | CODE.ALSO, ON SHEET 1, COMPLETE THE | | | PROJECT DETAILS INCLUDING NAME OF OWNER, | | | PROJECT ADDRESS (4888 N. HAVERHILL RD), | | | ZIP (33417) AND PERMIT NUMBER (02102206) | | | | | | --PROVISO-- | | | THE SUBMITTED PGT INDUSTRIES ALUMINUM | | | FIXED WINDOW (PRODUCT APPROVAL | | | NOA# 01-0102.01) DOES NOT HAVE | | | SUFFICIENT DESIGN PRESSURE RATING FOR | | | WINDOW MARK 'A' (-64.4 PSF REQ'D) OR | | | WINDOW MARK 'C' TO OFFICE 120 (-65.3 PSF | | | REQ'D).THE SUBMITTED ARCH ALUMINUM | | | WINDOW WALL SYSTEM PRODUCT APPROVAL | | | NOA# 01-0329.02 CAN BE USED. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-06-06 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-06-05 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-06-05 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2003-06-05 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 1/10/03 AND 4/18/03: | | | | | | 1) THIS COMMENT HAS NOT BEEN ADDRESSED. | | | FBC* 104.2.4SITE SURVEY.A SIGNED AND | | | SEALED SURVEY DRAWING PREPARED BY A | | | QUALIFIED SURVEYOR IS REQUIRED (REF: | | | 472.025(1) FL. STATUTES.). THE SUBMITTED | | | SURVEY SHEET IS FOR A DELRAY BEACH | | | LOCATION (???) | | | | | | 3) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 4) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, THE PLANS STAMPED BY THEM | | | AND A COPY OF THE RECEIPT SUBMITTED TO | | | THE CITY OF WEST PALM BEACH CONSTRUCTION | | | SERVICES DEPARTMENT BEFORE A BUILDING | | | PERMIT CAN BE ISSUED. | | | | | | 5) FBC 11-4.1.2THE BUILDING SHALL BE | | | SERVED BY AT LEAST ONE ACCESSIBLE ROUTE | | | FROM THE ACCESSIBLE PARKING AND THE BUS | | | STOP.ACCEPTABILITY OF THIS PERMIT | | | APPLICATION IS CONTINGENT UPON THE | | | CIVIL/SITE PLANS, UNDER PERMIT 02102208, | | | BEING PERMITTED. | | | | | | 6) FBC 13-103.1.1.1 AND 103.1.2SHEET 2 | | | OF THE SUBMITTED ENERGY CODE COMPLIANCE | | | FORMS SHALL BE SIGNED BY THE OWNER (OR | | | THE PROJECT ARCHITECT, OR OTHER | | | AUTHORIZED AGENT DESIGNATED BY THE | | | OWNER) TO CERTIFY COMPLIANCE WITH THE | | | CODE.ALSO, THE ARCHITECT'S NAME AND | | | REGISTRATION NUMBER SHALL BE ADDED ABOVE | | | THOSE OF THE OTHER SYSTEM DESIGNERS.ON | | | SHEET 1, COMPLETE THE PROJECT DETAILS | | | INCLUDING NAME OF OWNER, PROJECT ADDRESS | | | (4888 N. HAVERHILL RD), ZIP (33417) | | | AND PERMIT NUMBER (02102206). | | | | | | 7) PRODUCT APPROVALS.THE PRODUCT | | | APPROVAL SHEETS SHALL BE MARKED, AS | | | APPROPRIATE TO IDENTIFY WHICH PRODUCT | | | OPTIONS/MATERIALS ARE TO BE USED, ALSO: | | | (A) THE SUBMITTED COPIES OF TIMBERLINE | | | SELECT 40 ASPHALT SHINGLE PRODUCT | | | APPROVAL NOA# 03-0219.08 IS MISSING | | | SHEET 3 OF 3.ALSO, SHEET 2 IS A POOR | | | COPY.SUBMIT TWO COPIES OF A COMPLETE | | | AND LEGIBLE PRODUCT APPROVAL. | | | (G) THE DRAWING SHEETS OF THE SUBMITTED | | | COPIES OF ARCH ALUMINUM NARROW STILE | | | DOOR PRODUCT APPROVAL NOA# 01-0910.09 | | | ARE POORLY REPRODUCED.SUBMIT LEGIBLE | | | COPIES.NOTE THAT THESE DOORS ARE NOT | | | IMPACT RESISTANT, AND WILL REQUIRE THE | | | INSTALLATION OF HURRICANE SHUTTERS. | | | COPIES OF MIAMI-DADE PRODUCT APPROVALS | | | CAN BE PRINTED FROM THEIR WEBSITE,WWW. | | | MIAMIDADE.GOV/BUILDINGCODE/PC-SEARCH.HTM | | | (H) THE SUBMITTED ARCH ALUMINUM SERIES | | | 4500 STOREFRONT PRODUCT APPROVAL NOA# | | | 00-1220.05 IS FOR A NON-IMPACT RATED | | | SYSTEM.THE INSTALLATION OF HURRICANE | | | MISSILE IMPACT PROTECTION SHUTTERS WILL | | | BE REQUIRED.THE PLANS SHALL IDENTIFY | | | WHERE THIS SYSTEM IS TO BE USED AND A | | | HURRICANE MISSILE IMPACT PROTECTION | | | SHUTTER PRODUCT APPROVAL SHALL BE | | | SUBMITTED. | | | | | | 13) NOTED: | | | SHEET A5-1.1, BUILDING CODE ANALYSIS | | | TABLE, STATES MINIMUM ALLOWABLE | | | CONSTRUCTION TYPE VI. | | | | | | 15) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-04-23 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-05 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-04-18 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2003-04-17 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 1/10/03: | | | | | | 1) THIS COMMENT HAS NOT BEEN ADDRESSED. | | | FBC* 104.2.4A SIGNED AND SEALED SURVEY | | | DRAWING IS REQUIRED.THE SUBMITTED | | | SURVEY SHEET IS FOR A DELRAY BEACH | | | LOCATION (???) | | | | | | 3) INFORMATIVE: | | | A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 4) INFORMATIVE: | | | IMPACT FEES MUST BE PAID TO PALM BEACH | | | COUNTY, THE PLANS STAMPED BY THEM AND A | | | COPY OF THE RECEIPT SUBMITTED TO THE | | | CITY OF WEST PALM BEACH CONSTRUCTION | | | SERVICES DEPARTMENT BEFORE A BUILDING | | | PERMIT CAN BE ISSUED. | | | | | | 5) FBC 11-4.1.2THE BUILDING SHALL BE | | | SERVED BY AT LEAST ONE ACCESSIBLE ROUTE | | | FROM THE ACCESSIBLE PARKING AND BUS STOP | | | ACCEPTABILITY OF THESE PLANS IS | | | CONTINGENT UPON THE CIVIL/SITE PLANS, | | | PERMIT# 02102208, BEING PERMITTED. | | | | | | 6) THIS COMMENT HAS NOT BEEN ADDRESSED. | | | FBC 13-103.0ENERGY CODE COMPLIANCE | | | SHALL BE DEMONSTRATED BY SUBMITTAL OF | | | APPROPRIATE CODE COMPLIANCE FORMS | | | | | | 7) PRODUCT APPROVALS: DOOR, WINDOW, ROOF | | | (A) ASPHALT SHINGLE PRODUCT APPROVAL | | | NOA# 00-0105.02 WILL EXPIRE ON 4/22/03. | | | IF THIS OCCURS BEFORE THE A PERMIT | | | APPLICATION IS MADE, THEN THE PRODUCT | | | APPROVAL IS NOT VALID AND NEW ONE SHALL | | | BE SUBMITTED. | | | (B) THE SUBMITTED COPY OF STEELCRAFT | | | MANUF. 98/99 RIM EXIT STEEL DOOR PRODUCT | | | APPROVAL NOA# 01-1203.11 IS MISSING TEXT | | | SHEETS 2 AND 3 (SPECIFIC AND GENERAL | | | CONDITIONS), AND SOME OF THE DRAWING | | | SEETS.SUBMIT A COMPLETE PRODUCT | | | APPROVAL. | | | (C) THE SUBMITTED COPY OF STEELCRAFT | | | MANUF. F,M FRAME STEEL DOOR PRODUCT | | | APPROVAL NOA# 01-0129.12 IS MISSING TEXT | | | SHEETS 2 AND 3 (SPECIFIC AND GENERAL | | | CONDITIONS), AND SOME OF THE DRAWING | | | SHEETS.SUBMIT A COMPLETE PRODUCT | | | APPROVAL. | | | (D) SHEET A5-10.1, WNDOW SCHEDULE. | | | THE WIDTH OF WINDOW TYPE B, AT 7 FEET, | | | IS OUTSIDE THE SCOPE OF THE SUBMITTED | | | ARCH ALUMINUM WINDOW WALL PRODUCT | | | APPROVAL NOA# 01-0329.02 AND THE | | | SUBMITTED PGT INDUSTRIES FIXED WINDOW | | | PRODUCT APPROVAL NOA# 02-0716.03. SUBMIT | | | A PRODUCT APPROVAL WHICH COVERS THE | | | SPECIFIED WINDOW DIMENSIONS. | | | (E) THE DRAWING SHEETS OF THE SUBMITTED | | | COPIES OF ARCH ALUMINUM STOREFRONT DOOR | | | PRODUCT APPR. NOA# 01-0919.02 ARE POORLY | | | REPRODUCED. SUBMIT LEGIBLE COPIES. | | | COPIES OF MIAMI-DADE PRODUCT APPROVALS | | | CAN BE PRINTED FROM THEIR WEBSITE,WWW. | | | MIAMIDADE.GOV/BUILDINGCODE/PC-SEARCH.HTM | | | (F) THE SUBMITTED 2 PAGE COPY EXTRACT OF | | | THE 48 PAGE GAF MODIFIED BITUMEN ROOF | | | PRODUCT APPROVAL NOA# 00-0331.09 DOES | | | NOT INCLUDE A STATEMENT OF THE MAXIMUM | | | DESIGN PRESSURE AND STATES THAT "ALL | | | GENERAL AND SYSTEM LIMITATIONS SHALL | | | APPLY".SUBMIT COPIES OF THE SHEETS | | | WHICH STATE THE GENERAL AND SYSTEM | | | LIMITATIONS AND THE MAX DESIGN PRESSURE. | | | COPIES OF MIAMI-DADE PRODUCT APPROVALS | | | CAN BE PRINTED FROM THEIR WEBSITE,WWW. | | | MIAMIDADE.GOV/BUILDINGCODE/PC-SEARCH.HTM | | | | | | 8) FBC* TABLE 2306.1STRUCTURAL NOTES, | | | SHEET STR-GN, PLYWOOD ROOF DECKING | | | NOTE 3B.THE REVISION MADE, PER THE | | | G.D. KLIEGER COMMENT RESPONSE LETTER, IS | | | NOTED.THE * FOLLOWING THE REFERENCE TO | | | FBC MEANS CITY OF WPB AMENDMENTS TO THE | | | FLORIDA BUILDING CODE (SEE KEY ABOVE). | | | THE AMENDED TABLE REQUIRES THE PERIMETER | | | ZONE AT THE GABLE END TO HAVE NAILS | | | SPACED AT 4"O.C. MAXIMUM, FOR A DISTANCE | | | OF 5 FT (NOT 4 FT) FROM THE EDGE OF THE | | | ROOF. | | | | | | 9) SHEET S-5.02, ROOF TRUSS ANCHORS. | | | THE ADDITION OF TYPICAL TRUSS ANCHOR | | | SPECIFICATION, PER THE K.D. KLIEGER | | | COMMENT RESPONSE LETTER OF 2/5/03, IS | | | NOTED.THE PLAN SHALL STILL BE AMENDED | | | TO STATE THE WORST CASE UPLIFT TO BE | | | RESISTED BY THESE ANCHORS.NOTE THE | | | IMPLICATIONS OF COMMENT 14 BELOW. | | | | | | 13) SHEET A5-1.1, BUILDING CODE ANALYSIS | | | TABLE.THE STATED CONSTRUCTION TYPE HAS | | | REVISED FROM TYPE V TO TYPE VI.THIS IS | | | NOT CONSISTENT WITH THE CONSTRUCTION | | | SHOWN ON SHEETS S-5.O1, S-5.03 AND | | | A5-6.1 THRO' A5-7.2.AMEND SHEET AS | | | REQUIRED. | | | | | | 14) COLD FORM METAL TRUSSES.SHEETS | | | A5-2.2, A5-5.1 THRO' A5-7.2 HAVE ALL | | | BEEN REVISED TO SHOW COLD FORM METAL | | | TRUSSES.THE REVISION DOES NOT | | | CORRELATE WITH SHEETS S-5.02, S-5.03 OR | | | STR-GN WHICH ALL STILL REFER TO WOOD | | | TRUSSES.AMEND THE PLANS. | | | | | | 15) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-01-10 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-01-10 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-01-10 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2003-01-10 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) FBC* 104.2.4A SIGNED AND SEALED | | | SURVEY DRAWING IS REQUIRED. | | | | | | 2) FL. ADMIN. CODE 61G1-16.003EACH | | | ARCHITECTURAL PLAN SHEET SHALL BE SIGNED | | | PERSONALLY, NOT SIGNATURE STAMPED. | | | | | | 3) INFORMATIVE: | | | A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 4) INFORMATIVE: | | | IMPACT FEES MUST BE PAID TO PALM BEACH | | | COUNTY, THE PLANS STAMPED BY THEM AND A | | | COPY OF THE RECEIPT SUBMITTED TO THE | | | CITY OF WEST PALM BEACH CONSTRUCTION | | | SERVICES DEPARTMENT BEFORE A BUILDING | | | PERMIT CAN BE ISSUED. | | | | | | 5) FBC 11-4.1.2THE BUILDING SHALL BE | | | SERVED BY AT LEAST ONE ACCESSIBLE ROUTE | | | FROM THE ACCESSIBLE PARKING. | | | ACCEPTABILITY OF THESE PLANS IS | | | CONTINGENT UPON THE CIVIL/SITE PLANS, | | | PERMIT# 02102208, BEING PERMITTED. | | | | | | 6) FBC 13-103.0ENERGY CODE COMPLIANCE | | | SHALL BE DEMONSTRATED BY SUBMITTAL OF | | | APPROPRIATE CODE COMPLIANCE FORMS | | | | | | 7) SUBMIT PRODUCT APPROVALS FOR THE | | | ROOFING, EXTERIOR DOORS AND WINDOWS. | | | | | | 8) FBC* TABLE 2306.1STRUCTURAL NOTES, | | | SHEET STR-GN, PLYWOOD ROOF DECKING.THE | | | PERIMETER ZONE AT THE GABLE END SHALL | | | HAVE NAILS SPACED AT 4"O.C. MAXIMUM, TO | | | A DISTANCE OF 5 FEET (NOT 24") FROM THE | | | EDGE OF THE ROOF. | | | | | | 9) STRUCTURAL NOTES, SHEET STR-GN, WOOD | | | TRUSS NOTE 6.IT IS NOTED THAT THE | | | TRUSS DESIGN ENGINEER IS TO PROVIDE THE | | | WIND UPLIFT REACTIONS.THE PERMIT | | | CANNOT BE ISSUED UNTIL THE REACTIONS ARE | | | SPECIFIED ON THE PLANS FOR CROSS | | | REFERENCE AGAINST THE PROPOSED TRUSS | | | ANCHORS AND STRAPS. | | | | | | 10) FBC 11-4.16.3SHEET A1-2.41, DETAIL | | | 8A THRU 10B.THE HEIGHT OF THE W.C. | | | SEAT SHOULD BE 17" TO 19", NOT 1'-3". | | | | | | 11) FBC 2405.2THE GLAZED PANELS | | | ADJACENT DOORS 101.A, 113.A AND 121.A | | | ARE IN A 'HAZARDOUS LOCATION' AND ARE | | | REQUIRED TO BE SAFETY GLASS SATISFYING | | | THE REQUIREMENTS OF THE CONSUMER PRODUCT | | | SAFETY COMMISSION 16, CODE OF FEDERAL | | | REGULATIONS, PART 1201 (CPSC 16-CFR, | | | PART 1201).SUBMIT DETAILS TO | | | DEMONSTRATE COMPLIANCE. | | | | | | 12) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
14 |
Status |
P |
Date |
2006-11-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-16 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-15 |
Time |
16:22 |
Sent To |
PC |
|
| Notes |
| 2006-11-16 07:59:28 | REDLINED, | | | | | | GEN IS UNDER SEPARATE PERMIT FOR THIS BUILDING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
13 |
Status |
P |
Date |
2006-08-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-16 |
Time |
17:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-16 |
Time |
17:18 |
Sent To |
PC |
|
| Notes |
| 2006-08-16 00:00:00 | REVISED BLDG PLANS, GEN IS UNDER | | | 06050208 | | | | | | REDLING MISSING EQUIPMENT GROUNDING | | | CONDUCTOR FROM GEN TO BLDG. | | | 250.122 #3 MIN AS SHOWN UNDER GEN | | | PERMIT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
12 |
Status |
F |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-03 |
Time |
19:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-03 |
Time |
19:51 |
Sent To |
PC |
|
| Notes |
| 2006-08-03 00:00:00 | ** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE NOTES FROM PREVIOUS | | | REVIEWS WHICH STATES NO FURTHER | | | REVISIONS INCLUDING GENERATOR / ATS, | | | FUEL TANK ETC SHALL BE REVIEWED OR | | | STAMPED UNTIL SUCH TIME THE GENERATOR | | | WHICH WAS APPLIED FOR UNDER A SEPARATE | | | PERMIT IS ISSUED FOR PERMIT. | | | | | | CALLED CONTRACTOR AND LEFT MESSGAE ON MR | | | MARK FORD'S VM. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
11 |
Status |
F |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-20 |
Time |
20:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-20 |
Time |
20:12 |
Sent To |
|
|
| Notes |
| 2006-06-20 00:00:00 | *********** UNSAT ***************** | | | | | | 1) NOTE: PLEASE SEE THAT EXACT SAME | | | NOTES FROM REVIEW DONE ON5/14/06 STILL | | | APPLY. | | | NO CORRECTIONS OR CHANGES HAVE BEEN | | | MADE. | | | PLEASE SEE NOTES ARE ATTACHED FROM | | | PREVIOUS REVIEW. | | | | | | | | | 2) NOTE: PLEASE SEE FS 553.80(2)(B) WITH | | | RESPECT TO REPEAT COMMENTS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
10 |
Status |
F |
Date |
2006-05-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-14 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-14 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2006-05-14 00:00:00 | *******UNSAT ********* | | | | | | 1) NOTE: PLEASE SEE NOTES DATED ON ALL | | | PREVIOUS REVIEWS AND NOTES DATED | | | 7/18/05, 11/15/05,12/20/05. | | | GEN, ATSIS NOTE PART OF PERMIT. | | | PLANS , PERMIT APPLICATION AND FEES | | | SHALL BE SUBMITTED BEFORE ANY ANY OTHER | | | ELECTRICAL REVISIONS ARE DONE. | | | PLEASE KNOW, THE ELECTRICAL RISER AS | | | SHOWN DOES NOT MEET CODE COMPLIANCE AND | | | PREVIOUS PLANS WERE REDLINED NOT TO | | | INCLUDE ATS AND GEN. | | | PLEASE SUBMIT ALL INFORMATION FOR | | | GENERATOR PERMIT. | | | PLEASE SEE 225.31-225.39, 702.5, SUBMIT | | | COMPLETE PACKAGE. | | | PLEASE INCLUDE ALL SPECS/MANUAFCTURES | | | CUT SHEETS FOR GEN, ATS, AND FUEL SUPPLY | | | TANKS IF DIESEL/ PROPANE ETC. | | | ** PLEASE KNOW, A ROUGH INSPECTION WILL | | | NOT BE GIVEN AND THE PERMIT FOR | | | ELECTRICAL MAY BE REVOKED AS NOTES HAVE | | | NOT BEEN COMPLIED WITH FOR ALMOST 1 | | | YEAR.(10 MONTHS) | | | | | | PLEASE KNOW, ONCE PERMIT FOR GEN IS | | | ISSUED, OTHER REVISIONS CAN BE REVIEWED | | | AT THAT TIME. | | | | | | 2) NOTE: PLEASE SEE ADDRESS ON PLANS IS | | | NOT CORRECT. PLEASE SEE ADDRESS GIVEN | | | FOR PERMITTING OF THIS BUILDING WAS | | | "4888", PLANS READ 4884 WHICH IS THE | | | SITE ADDRESS. | | | TITLE BLOCKS FOR ALL SHEETS SHALL BE | | | REVISED. FAC 61G1-16.004,61G15-23.002. | | | | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2005-12-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-20 |
Time |
19:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-20 |
Time |
18:59 |
Sent To |
|
|
| Notes |
| 2005-12-20 00:00:00 | REDLINED: | | | | | | | | | GENERATOR AND ATS IS NOT INCLUDED ON | | | THIS PERMIT AND SHALL APPLY FOR SEPARATE | | | PERMIT, INCLUDING, PLANS AND FEES. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2005-11-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-15 |
Time |
11:01 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-11-15 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2005-11-15 00:00:00 | ********** UNSAT ********** | | | | | | 1)NOTE: PLEASE SEE REVIEW DATED 7/18/05 | | | WITH RESPECT TO GENERATOR INSTALLATION. | | | NO PERMIT APPLICATION TO DATE HAS BEEN | | | MADE FOR NEW GENERATOR. THIS MAY NOT BE | | | INCLUDED UNDER BASE BLDG. | | | PLEASE ALSO KNOW, A REVIEW FOR CODE | | | COMPOLIANCE WILL BE DONE AT THAT TIME. | | | PLEASE BE SURE TO SEE 2002 NEC, | | | 225.31-225.39, 445, 700ETC FOR | | | REQUIREMENTS. | | | | | | 2)NOTE: PLEASE SEE ALL ELECTRICAL SHEETS | | | SHALL CLEARLY SHOW REVISIONS, DATES, | | | IDENTIFIED BY CLOUDS AND TRIANGLES. | | | PLEASE KNOW: A RESPONSE LETTER TELLING | | | OF REV'S MADE ANDSCOPE OF WORK WILL HELP | | | GREATLY IN EXPEDITING THE PLAN REVIEW | | | PROCESS. | | | | | | | | | ** PLEASE SEE COMMENTS #1, PLEASE DO NOT | | | SUBMIT REVISION FOR THIS UNTIL GENERATOR | | | PERMIT HAS BEEN ISSUED. | | | PLEASE BE SURE WHEN THAT DOES OCCUR THAT | | | PLANS REFERENCE GENERATORUNDER | | | SEPARATE PERMIT,,#( ? ). | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2005-07-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-18 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-07-15 |
Time |
21:23 |
Sent To |
|
|
| Notes |
| 2005-07-18 00:00:00 | ************* UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE PLANS ARE NOW COMING | | | IN WITH A NEW GENERATOR SYSTEM WHICH WAS | | | NO PART OF ORIGIANL PLANS. PLEASE SEE | | | GEN SHALL BE UNDER A SEPARATE PERMIT. | | | PLEASE SUBMIT COMPLETE PACKAGE FOR GEN | | | REVIEW. | | | PLEASE BE SURE TO SEE 2002 FOR ALL GEN | | | REQUIREMENTS. | | | 450.13,702.5, ETC | | | PLEASE SUBMIT ALL SPECS/MANUFACTURE | | | SHEETS FOR GEN, ATS, ANY SUB0BASE FUEL | | | TANK ? | | | GEN'S SHALL BE SIZED FOR LOADS TO BE | | | SERVED. | | | | | | SUBMIT REVISED PLANS WHEN GEN AND ALL | | | TRADES RELATING TO GEN HAVE BEEN APPLIED | | | FOR AND ISSUED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEYPALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2005-07-15 00:00:00 | IN ELECTRIC FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-28 |
Time |
06:15 |
Rev Time |
0.20 |
| Received By |
dpalmer |
Date |
2005-02-28 |
Time |
06:14 |
Sent To |
|
|
| Notes |
| 2005-02-28 00:00:00 | ****** PROVISO ********* | | | | | | | | | | | | PURSUANT TO DECISION BY THE AHJ AND | | | BUILDING OFFICAL, ALL ELECTRICAL WORK TO | | | BE PERFORMED UNDER THE 2002 NEC. | | | PLANS ARE TO BE REVISED BEFORE ROUGH FOR | | | ANY CHANGES AFFECTING DESIGN. | | | | | | | | | PLEASE REVISE AND SUBMIT FOR REVIEW | | | BEFORE ROUGH ELECTRICAL INSPECTION. | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | | NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2004-03-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-03-02 |
Time |
07:40 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-03-02 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2004-03-02 00:00:00 | *** UNSAT *** | | | | | | 1)NOTE: PLEASE SEE CERTIFICATE OF | | | AUTHORIZATION, NAME AND LICENSE # FOR | | | ENGINEER IS REQ'D ON ALL PLANS. | | | FS 471.023,FAC 61G15-23.002 | | | THIS WAS NOT A PREVIOUS COMMENT. | | | THIS IS REQ'D ON ALL SHEETS AND MAY BE | | | HAND WRITTEN. | | | | | | PLEASE CALL IF THERE ARE ANY QUESTIONS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-10-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-03 |
Time |
06:39 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-10-03 |
Time |
06:39 |
Sent To |
|
|
| Notes |
| 2003-10-03 00:00:00 | NO CHANGES, PLANS OK. STAMPED ON 3/28/03 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-05-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-15 |
Time |
09:32 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-05-15 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2003-05-15 00:00:00 | PLANS STILL OK, STAMPED PREVIOUS REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-03-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-28 |
Time |
04:32 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-03-28 |
Time |
03:59 |
Sent To |
|
|
| Notes |
| 2003-03-28 00:00:00 | PLANS OK, AND STAMPED FOR ELECTRICAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-26 |
Time |
08:21 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2002-11-26 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2002-11-26 00:00:00 | *************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE, LOAD CALCULATIONS | | | NEED TO BE COMPLETED ON THE BOTTOM OF | | | 5L/A. PLEASE NOTE LOAD SHOWN ON 5MDP | | | DOES NOT CORRELATE WITH 5L/A. | | | | | | 2)NOTE: PLEASE CLARIFY MCB IN 5MDP | | | COMPLIES WITH 230-76/230-79. SHOWN AS | | | SHUNT TRIP, PLEASE NOTE, MUST HAVE A | | | MANUAL MEANS OF OPERATING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2003-06-25 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-06-25 |
Time |
10:33 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-06-25 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2003-06-25 00:00:00 | PASSED: | | | 1. SEE PERMIT # 02102208 FOR UNDERGROUND | | | UTILITIES AND SITE WORKS. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2003-03-17 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-03-17 |
Time |
10:27 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-03-17 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2003-03-17 00:00:00 | FAILED: | | | 1. SEE REVIEW COMMENTS, PERMIT #02102208 | | | DATED 03-17-03. | | | IF ANY QUESTION PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2002-11-06 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-11-06 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
mamini |
Date |
2002-11-06 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2003-01-10 00:00:00 | FAILED: | | | 1. SEE REVIEW COMMENTS FOR PLAN REVIEW # | | | 02102208. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
7 |
Status |
F |
Date |
2006-06-16 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-06-16 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-06-16 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2006-06-16 00:00:00 | ***DENIED*** | | | | | | PLEASE SEE BUILDING REVIEW COMMENT | | | REGARDING ARRANGEMENT OF MEANS OF EGRESS | | | REGARDING THE MEETING SPACE. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
P |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-01-03 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-01-03 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
F |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-11-17 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-11-17 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2005-11-17 00:00:00 | ******DENIED****** | | | REVISION DATED 9/9/05 | | | PLANS APPROVED ON 4/24/03 | | | | | | 1) PLEASE SEE ELECTRICAL REVIEW COMMENTS | | | REGARDING THE GENERATOR. | | | | | | 2) DRAWINGS SHOW (2) DRY FIRE SPRINKLER | | | HEADS AND NO COVERAGE IN TEL. COMM. | | | ROOM. PLEASE EXPLAIN, AS THIS | | | ARRANGEMENT WOULD NOT BE ACCEPTABLE. | | | | | | 3) AS A REMINDER, SEPARATE SHOP DRAWINGS | | | FOR FIRE SPRINKLER AND FIRE ALARM | | | SYSTEMS ARE REQUIRED. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/ WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2005-08-15 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-08-15 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-08-15 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2005-08-15 00:00:00 | PLANS APPROVED ON 4/24/03 | | | | | | REVISION DATED 7/1/05 | | | | | | SEPARATE SHOP DRAWINGS AND PERMITS ARE | | | REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM SYSTEMS. | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-11-03 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-11-03 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-11-03 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2003-11-03 00:00:00 | PLANS OK APPROVED ON 04-24-03 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-04-24 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-04-24 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-04-24 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-12-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-12-04 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-12-04 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2002-12-04 00:00:00 | 1) HOW IS FIRE AND PARAMEDICAL ACCESS | | | OBTAINED TO THE EDUCATIONAL BUILDING. | | | THE 15' CIRCLE DOES NOT MEET THE | | | MINIMUM CODE REQUIREMENTS OF AT LEAST | | | 20'. | | | | | | 2) BUILDING ADDRESS REQUIRED ON | | | BUILDING. | | | | | | 3) PLEASE PROVIDE THIS OFFICE A LIFE | | | SAFETY PLAN. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2006-11-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-21 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-21 |
Time |
16:01 |
Sent To |
FIRE |
|
| Notes |
| 2006-11-21 16:02:49 | TO "F" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2006-11-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-09 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-09 |
Time |
15:43 |
Sent To |
E |
|
| Notes |
| 2006-11-09 15:43:51 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2006-11-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-04 |
Time |
19:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-04 |
Time |
19:21 |
Sent To |
P |
|
| Notes |
| 2006-11-04 19:21:53 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2006-08-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-14 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-14 |
Time |
13:54 |
Sent To |
M |
|
| Notes |
| 2006-08-14 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2006-07-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-31 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-31 |
Time |
16:27 |
Sent To |
E |
|
| Notes |
| 2006-07-31 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-20 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-20 |
Time |
08:17 |
Sent To |
M |
|
| Notes |
| 2006-06-20 00:00:00 | TO "PKRAUSS" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-04-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-25 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-25 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2006-05-11 00:00:00 | TO "COMM" BD#30-REV | | 2006-04-25 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-31 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-31 |
Time |
13:50 |
Sent To |
B |
|
| Notes |
| 2006-01-31 00:00:00 | TO "RBROWN" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-12-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-10 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-10 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2006-01-03 00:00:00 | SENT TO M WENNERGREN DESK WITH NOTE TO | | | RETURN TO R BROWN AFTER REVIEW. | | 2005-12-10 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-23 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-23 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2005-09-28 00:00:00 | TO "COMM" BD#43 | | 2005-09-23 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-07-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-07 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-07 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2005-07-13 00:00:00 | TO "COMM" BD#37 | | 2005-07-07 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-02-24 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2005-02-03 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-02-03 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2005-02-24 00:00:00 | PLANS ON RACK (COMMERCIAL BOARD #17) |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-02-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-06 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-06 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2004-02-06 00:00:00 | TO COMM BD#45 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-09-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-12 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-12 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2003-09-12 00:00:00 | COMM BD#42/PLANS ON RACK SHELF 4 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-09-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-12 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-12 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2003-09-12 00:00:00 | COMM BD#42/PLANS ON RACK SHELF 4 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-06-06 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-05 |
Time |
08:57 |
Sent To |
B |
|
| Notes |
| 2003-05-05 00:00:00 | COMM BOARD #12,PLANS NEXT TO CONF ROOM. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-03-13 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-13 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-14 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2003-03-14 00:00:00 | COMM BOARD #46 | | | ON RACK 1ST & 2ND SHELF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
10 |
Status |
P |
Date |
2006-09-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-09-11 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-09-11 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2006-09-11 00:00:00 | PROVISO FROM REVIEW DATED 6/20/06: | | | | | | REVISION TO PLAN SHEET M5-2.01 INDICATES | | | REMOVING AHU-3 FROM THE TEL/COMM ROOM | | | #118.PLEASE CLARIFY THE RATING OF THIS | | | WALL PENETRATION.DOES THE RATING GO | | | BEYOND THE DROP RATED CEILING OR END AT | | | THE CEILING?PLEASE REVISE THE WALL | | | DETAIL SHOULD THE RATING STOP AT THE | | | CEILING. | | | | | | | | | NEW PROVISO: | | | GENERAL NOTES: REVISION ADDED NOTE #4 | | | WHICH INDICATES THE HVAC CLOSET WILL NOW | | | SERVE AS A PLENUM AND ALL DEVICES | | | LOCATED IN THE SPACE SHALL BE PLENUM | | | RATED.PLEASE NOTE, THIS SHALL INCLUDE | | | THE DOOR AND DOOR FRAME. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719 OR | | | E-MAIL [email protected]. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
9 |
Status |
P |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-06-20 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-06-20 |
Time |
10:41 |
Sent To |
E |
|
| Notes |
| 2006-06-20 00:00:00 | PROVISO: | | | | | | REVISION TO PLAN SHEET M5-2.01 INDICATES | | | REMOVING AHU-3 FROM THE TEL/COMM ROOM | | | #118.PLEASE CLARIFY THE RATING OF THIS | | | WALL PENETRATION.DOES THE RATING GO | | | BEYOND THE DROP RATED CEILING OR END AT | | | THE CEILING?PLEASE REVISE THE WALL | | | DETAIL SHOULD THE RATING STOP AT THE | | | CEILING. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-06-12 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-06-12 |
Time |
14:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-01-03 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-01-03 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2006-01-03 00:00:00 | PROVISO: | | | PRIOR TO ROUGH INSPECTION, PLEASE | | | PROVIDE DETAIL THE MOUNTING DETAIL FOR | | | THE HORIZONTAL UNIT LOCATED IN THE | | | COM/TEL ROOM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | 2005-12-20 00:00:00 | NEW SHEET ADDED DATED 12/9/05 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-11-16 |
Time |
13:20 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2005-11-16 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2005-11-16 00:00:00 | PLEASE NOTE THE FOLLOWING - REVIEW DOES | | | NOT INCLUDE APPROVAL FOR THE GENERATOR, | | | (SEE ALSO COMMENTS BY DEWEY PALMER, | | | ELECTRICAL PLANS EXAMINER). |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2005-07-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-27 |
Time |
16:22 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2005-07-27 |
Time |
15:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-08 |
Time |
10:56 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2005-03-08 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2005-03-08 00:00:00 | EDUCATION BUILDING (5) | | | APPROVED 5-10-03 - NO CHANGES ON THE | | | RESUBMITTAL. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-05-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-05-10 |
Time |
11:38 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-05-10 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-04-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-04-24 |
Time |
14:16 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2003-04-24 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2003-04-24 00:00:00 | PROVISO: | | | | | | PLAN SHEET M5-2.01 STAFF TOILET ROOM | | | #122, INDICATES A RETURN AIR GRILLE IN | | | THE TOILET ROOM.AS PER 2001 FBC(M) | | | TABLE 403.3 NOTE B, MECHANICAL EXHAUST | | | REQUIRED & RECIRCULATION IS PROHIBITED | | | FROM PUBLIC RESTROOMS. PLEASE RELOCATE | | | RETURN AIR GRILLE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-12-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-12-03 |
Time |
13:22 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2002-12-03 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2002-12-03 00:00:00 | EDUCATIONAL BUILDING #5 | | | DENIED: | | | | | | PRIOVIDE INFORMATION ON THE CONDENSATE | | | DRAIN. INDICATE TERMINATION - AS PER | | | 2001 FBC(M) 307.2.1 (1) UNITS LARGER | | | THAN 6 TON SHALL DISCHARGE INTO STORM | | | DRAIN OR AN APPROVED DRYWELL. | | | | | | FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | | SHALL HAVE NOTIFICATION TO ALARM/STROBE | | | IN NORMALLY OCCUPIED AREAS OR A SUPER- | | | VISORY SIGNAL AT A CONSTANTLY ATTENDED | | | LOCATION.NFPA 90A 4-4.4.3 & 4-4.4.2 | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
P |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-11-07 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-11-07 |
Time |
14:21 |
Sent To |
PC |
|
| Notes |
| 2006-11-07 14:23:09 | AS BUILT REVISIION FOR DWVU/G |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-06-20 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-06-20 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2006-06-20 00:00:00 | REVISION OK SHTS P5-2.01 & P5-3.01 NEW | | | BUILDING LAYOUT/RISERS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2006-01-04 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-01-04 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-01-04 |
Time |
09:10 |
Sent To |
B |
|
| Notes |
| 2006-01-04 00:00:00 | REVISION APPROVED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2005-10-09 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-10-09 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-10-09 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2005-10-09 00:00:00 | PAUL SCHMITZ | | | FBC2001 FUEL GAS CODEPLAN REVIEW | | | FBC 2001 PLUMBING CODEPLAN REVIEW | | | FBC 2001 FL ACESSIBILITY CODE | | | PLAN REVIEW, DENIED | | | WHEN RE- SUBMITTING PLANS PLEASE SUBMITT | | | A TRANSMITTAL LETTER FOR ALL DISCIPLINES | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE. IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1) PLEASE ADDRESS PREVIOUS COMMENTS, | | | DATED 8-05-05 BY KEN STEVENS | | | | | | 2. SHTS P5-2.01 & 5-3.01 THE BACKFLOW | | | FOR THE 1/2" WATER LINE TO AHU-3 SHALL | | | BE LOCATED A MAXIMUM OF 4' ABOVE FINISH | | | FLOOR FOR SERVICE AND CERTIFICATION. | | | SHT M5-601,NOTE #4 MOUNT AHU BELOW | | | CEILING, PLEASE CLARIFY. | | | 3. AN RPZ BACKFLOW IS REQUIRED ON THE | | | WATER SERVICE OF THE BUILDING. SECTION | | | 608.13.2. | | | END OF COMMENTS, QUESTIONS 561-805-6692 | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2005-08-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-08-05 |
Time |
11:00 |
Rev Time |
1.36 |
| Received By |
kstevens |
Date |
2005-08-05 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2005-08-05 00:00:00 | REVISION DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | A. THIS REVISION IS A COMPLETE CHANGE OF | | | THE FLOOR PLAN. | | | 1. SHT A5-4.1 DETAIL #2 WATER CLOSETS | | | SHALL BE 1'6" FROM THE SIDE WALL TO THE | | | CENTERLINE OF THE FIXTURE. 1'8" SHOWN. | | | FIGURE 28. | | | 2. SHTS P5-2.01 & 5-3.01 THE BACKFLOW | | | FOR THE 1/2" WATER LINE TO AHU-3 SHALL | | | BE LOCATED A MAXIMUM OF 4' ABOVE THE | | | FLOOR FOR SERVICE AND CERTIFICATION. - | | | NO CONDENSATE IS SHOWN FOR AHU-3. PLEASE | | | CLARIFY IF THERE WILL BE A CONDENSATE | | | LINE FOR THE AIR HANDLER. | | | 3. AN RPZ BACKFLOW IS REQUIRED ON THE | | | WATER SERVICE OF THE BUILDING. SECTION | | | 608.13.2. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-06-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-07 |
Time |
13:09 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-06-07 |
Time |
13:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-04-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-01 |
Time |
11:25 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-04-01 |
Time |
11:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-12-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-12-11 |
Time |
17:49 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2002-12-11 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2002-12-11 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT 5-2.1 MINIMUM FACILITIES REQUIRE | | | 2 DRINKING FOUNTAINS. A HI/LOW DRINKING | | | FOUNTAIN IS CONSIDERED 1 FIXTURE SO ONE | | | MORE DRINKING FOUNTAIN IS REQUIED. TABLE | | | 403.1 | | | 2) SHTS A5-2.1 & A5-4.1, TOILET ROOMS | | | #144 & 122, IF TOILET FACILITIES ARE | | | PROVIDED ON A SITE, THEN EACH SUCH PUB- | | | LIC AND COMMON USE TOILET FACILITY SHALL | | | COMPLY WITH 11-4.22 PER SECTION 11-4.1.2 | | | (6). | | | 3) SHT P5-3.01 WATER RISER DIAGRAM, A | | | BACKFLOW IS REQUIRED, AND WATER HAMMER | | | ARRESTORS REQUIRED BY 406.9 SHALL BE | | | LOCATED NEAR THE FIXTURE IN AN "EFFECT- | | | IVE RANGE" NOT AT THE TOP OF THE DROPS. | | | PER PDI-WH 201 AND MANUF. INSTALLATION | | | INSTRUCTIONS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-01-04 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-01-04 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-01-04 |
Time |
17:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-06-06 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-06-06 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-01-13 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-01-13 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-01-13 00:00:00 | DENIED, NEED MINOR AMENDMENT AND THE | | | PLAT TO BE RECORDED |
|
|