| Plan Review Stops For Permit 02102198 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2005-02-25 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-02-25 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2004-03-04 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-03-04 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-03-04 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2004-03-04 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | 61G1-16.004FL. ADMIN. CODE.ADD, TO | | | EACH ARCHITECTURAL SHEET, THE PRINTED | | | NAME AND LICENSE NUMBER OF JORGE GARCIA | | | AS THE ARCHITECT WHO SEALED THE PLANS. | | | THIS MAY BE DONE BY STAMP OR HANDWRITTEN | | | | | | THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2003-09-30 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-09-30 |
Time |
19:31 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-09-30 |
Time |
19:31 |
Sent To |
|
|
| Notes |
| 2003-09-30 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 6/3/03: | | | | | | 3) THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 4) IMPACT FEES. THE PLANS SHALL BE TAKEN | | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | | STAMPED AT THAT OFFICE AND A COPY OF THE | | | PAID RECEIPT SUBMITTED TO THE CITY OF | | | WEST PALM BEACH DEPT OF CONSTRUCTION | | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | | | 6) FBC 13-103.1.1.1 AND 103.1.2SHEET 2 | | | OF THE SUBMITTED ENERGY CODE COMPLIANCE | | | FORMS SHALL BE SIGNED BY THE OWNER (OR | | | THE PROJECT ARCHITECT, OR OTHER | | | AUTHORIZED AGENT DESIGNATED BY THE | | | OWNER) TO CERTIFY COMPLIANCE WITH THE | | | CODE.ALSO, ON SHEET 1, COMPLETE THE | | | PROJECT DETAILS INCLUDING NAME OF OWNER, | | | PROJECT ADDRESS (4884 N. HAVERHILL RD), | | | ZIP (33417) AND PERMIT NUMBER (02102198) | | | | | | 7) PRODUCT APPROVALS.THE PRODUCT | | | APPROVAL SHEETS SHALL BE MARKED, AS | | | APPROPRIATE TO IDENTIFY WHICH PRODUCT | | | OPTIONS/MATERIALS/SIZES ARE TO BE USED, | | | ALSO: | | | (I) DRAWING SHEET 1 OF THE SUBMITTED PGT | | | INDUSTRIES ALUMINUM FIXED WINDOW PRODUCT | | | APPROVAL NOA# 01-0102.01 STATES THAT THE | | | DESIGN PRESSURE RATING OF THE IMPACT | | | WINDOWS, WITH HEAT STRENGTHENED | | | LAMINATED GLASS, IS +60 PSF & -60 PSF. | | | THIS IS EXCEEDED BY THE MAXIMUM NEGATIVE | | | DESIGN PRESSURE (-76 PSF) STATED ON PLAN | | | SHEETS A1-5.1 AND A1-5.2 (ELEVATIONS). | | | SUBMIT A PRODUCT APPROVAL WITH THE | | | APPROPRIATE DESIGN PRESSURE RATING. | | | (J) SUBMIT A PRODUCT APPROVAL FOR THE | | | GLAZED SLIDING DOORS TO THE GUARD HOUSE. | | | | | | --PROVISO-- | | | THE SUBMITTED ARCH ALUMINUM NARROW STILE | | | DOOR PRODUCT APPROVAL NOA# 01-0910.09 | | | STATES THAT THESE DOORS ARE NOT IMPACT | | | RESISTANT.SUBMIT A PRODUCT APPROVAL | | | FOR HURRICANE MISSILE IMPACT PROTECTION | | | SHUTTERS IF THESE DOORS ARE TO USED. | | | | | | --PROVISO-- | | | THE SUBMITTED ARCH ALUMINUM SERIES 4500 | | | STOREFRONT PRODUCT APPROVAL | | | NOA# 00-1220.05 STATES THAT THIS SYSTEM | | | IS NOT IMPACT RESISTANT.SUBMIT A | | | PRODUCT APPROVAL FOR HURRICANE MISSILE | | | IMPACT PROTECTION SHUTTERS IF THIS | | | SYSTEM IS TO BE USED. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-06-03 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-06-03 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-06-03 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2003-06-03 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 1/8/03 AND 4/24/03: | | | | | | 1) THIS COMMENT HAS NOT BEEN ADDRESSED. | | | FBC* 104.2.4SITE SURVEY.A SIGNED AND | | | SEALED SURVEY DRAWING PREPARED BY A | | | QUALIFIED SURVEYOR IS REQUIRED (REF: | | | 472.025(1) FL. STATUTES).THE SUBMITTED | | | SURVEY SHEET IS FOR A DELRAY BEACH | | | LOCATION (???). | | | | | | 3) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 4) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, THE PLANS STAMPED BY THEM | | | AND A COPY OF THE RECEIPT SUBMITTED TO | | | THE CITY OF WEST PALM BEACH CONSTRUCTION | | | SERVICES DEPARTMENT BEFORE A BUILDING | | | PERMIT CAN BE ISSUED. | | | | | | 5) FBC 11-4.1.2THE BUILDING SHALL BE | | | SERVED BY AT LEAST ONE ACCESSIBLE ROUTE | | | FROM THE ACCESSIBLE PARKING AND THE BUS | | | STOP.ACCEPTABILITY OF THIS PERMIT | | | APPLICATION IS CONTINGENT UPON THE | | | CIVIL/SITE PLANS, UNDER PERMIT 02102208, | | | BEING PERMITTED. | | | | | | 6) FBC 13-103.1.1.1 AND 103.1.2SHEET 2 | | | OF THE SUBMITTED ENERGY CODE COMPLIANCE | | | FORMS SHALL BE SIGNED BY THE OWNER (OR | | | THE PROJECT ARCHITECT, OR OTHER | | | AUTHORIZED AGENT DESIGNATED BY THE | | | OWNER) TO CERTIFY COMPLIANCE WITH THE | | | CODE.ALSO, THE ARCHITECT'S NAME AND | | | REGISTRATION NUMBER SHALL BE ADDED ABOVE | | | THOSE OF THE OTHER SYSTEM DESIGNERS.ON | | | SHEET 1, COMPLETE THE PROJECT DETAILS | | | INCLUDING NAME OF OWNER, PROJECT ADDRESS | | | (4884 N. HAVERHILL RD), ZIP (33417) | | | AND PERMIT NUMBER (02102198). | | | | | | 7) PRODUCT APPROVALS.THE PRODUCT | | | APPROVAL SHEETS SHALL BE MARKED, AS | | | APPROPRIATE TO IDENTIFY WHICH PRODUCT | | | OPTIONS/MATERIALS ARE TO BE USED, ALSO: | | | (A) THE SUBMITTED COPIES OF TIMBERLINE | | | SELECT 40 ASPHALT SHINGLE PRODUCT | | | APPROVAL NOA# 03-0219.08 IS MISSING | | | SHEET 3 OF 3.ALSO, SHEET 2 IS A POOR | | | COPY.SUBMIT TWO COPIES OF A COMPLETE | | | AND LEGIBLE PRODUCT APPROVAL. | | | (G) THE DRAWING SHEETS OF THE SUBMITTED | | | COPIES OF ARCH ALUMINUM NARROW STILE | | | DOOR PRODUCT APPROVAL NOA# 01-0910.09 | | | ARE POORLY REPRODUCED.SUBMIT LEGIBLE | | | COPIES.NOTE THAT THESE DOORS ARE NOT | | | IMPACT RESISTANT, AND WILL REQUIRE THE | | | INSTALLATION OF HURRICANE SHUTTERS. | | | COPIES OF MIAMI-DADE PRODUCT APPROVALS | | | CAN BE PRINTED FROM THEIR WEBSITE,WWW. | | | MIAMIDADE.GOV/BUILDINGCODE/PC-SEARCH.HTM | | | (H) THE SUBMITTED ARCH ALUMINUM SERIES | | | 4500 STOREFRONT PRODUCT APPROVAL NOA# | | | 00-1220.05 IS FOR A NON-IMPACT RATED | | | SYSTEM.THE INSTALLATION OF HURRICANE | | | MISSILE IMPACT PROTECTION SHUTTERS WILL | | | BE REQUIRED.THE PLANS SHALL IDENTIFY | | | WHERE THIS SYSTEM IS TO BE USED AND A | | | HURRICANE MISSILE IMPACT PROTECTION | | | SHUTTER PRODUCT APPROVAL SHALL BE | | | SUBMITTED.THE PRODUCT APPROVAL SHEETS | | | SHALL BE MARKED, AS APPROPRIATE TO | | | IDENTIFY WHICH PRODUCT OPTIONS/MATERIALS | | | ARE TO BE USED. | | | | | | 15) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-04-23 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-04-23 |
Time |
19:14 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-04-23 |
Time |
19:14 |
Sent To |
|
|
| Notes |
| 2003-04-23 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 1/8/03: | | | | | | 1) THIS COMMENT HAS NOT BEEN ADDRESSED. | | | FBC* 104.2.4SITE SURVEY.A SIGNED AND | | | SEALED SURVEY DRAWING PREPARED BY A | | | QUALIFIED SURVEYOR IS REQUIRED (REF: | | | 472.025(1) FL. STATUTES.). THE SUBMITTED | | | SURVEY SHEET IS FOR A DELRAY BEACH | | | LOCATION (???). | | | | | | 3) INFORMATIVE: | | | A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 4) INFORMATIVE: | | | IMPACT FEES MUST BE PAID TO PALM BEACH | | | COUNTY, THE PLANS STAMPED BY THEM AND A | | | COPY OF THE RECEIPT SUBMITTED TO THE | | | CITY OF WEST PALM BEACH CONSTRUCTION | | | SERVICES DEPARTMENT BEFORE A BUILDING | | | PERMIT CAN BE ISSUED. | | | | | | 5) THE GBS ARCHITECURE RESPONSE IS NOTED | | | FBC 11-4.1.2 THE BUILDING SHALL BE | | | SERVED BY AT LEAST ONE ACCESSIBLE ROUTE | | | FROM THE ACCESSIBLE PARKING AND BUS STOP | | | ACCEPTABILITY OF THESE PLANS IS | | | CONTINGENT UPON THE CIVIL/SITE PLANS, | | | PERMIT# 02102208, BEING PERMITTED, | | | | | | 6) THIS COMMENT HAS NOT BEEN ADDRESSED. | | | FBC 13-103.0ENERGY CODE COMPLIANCE | | | SHALL BE DEMONSTRATED BY SUBMITTAL OF | | | APPROPRIATE CODE COMPLIANCE FORMS | | | | | | 7) PRODUCT APPROVALS: DOOR, WINDOW, ROOF | | | (A) ASPHALT SHINGLE PRODUCT APPROVAL | | | NOA# 00-0105.02 EXPIRED ON 4/22/03. | | | SUBMIT A VALID PRODUCT APPROVAL. | | | (B) THE SUBMITTED COPY OF STEELCRAFT | | | MANUF. 98/99 RIM EXIT STEEL DOOR PRODUCT | | | APPROVAL NOA# 01-1203.11 IS MISSING TEXT | | | SHEETS 2 AND 3 (SPECIFIC AND GENERAL | | | CONDITIONS), AND SOME OF THE DRAWING | | | SHEETS.SUBMIT A COMPLETE PRODUCT | | | APPROVAL. | | | (C) THE SUBMITTED COPY OF STEELCRAFT | | | MANUF. F, M FRAME STEEL DOOR PRODUCT | | | APPROVAL NOA# 01-0129.12 IS MISSING TEXT | | | SHEETS 2 AND 3 (SPECIFIC AND GENERAL | | | CONDITIONS), AND SOME OF THE DRAWING | | | SHEETS.SUBMIT A COMPLETE PRODUCT | | | APPROVAL. | | | (D) NOT USED | | | (E) THE DRAWING SHEETS OF THE SUBMITTED | | | COPIES OF ARCH ALUMINUM STOREFRONT DOOR | | | PRODUCT APPR. NOA# 01-0919.02 ARE POORLY | | | REPRODUCED.SUBMIT LEGIBLE COPIES. | | | COPIES OF MIAMI-DADE PRODUCT APPROVALS | | | CAN BE PRINTED FROM THEIR WEBSITE,WWW. | | | MIAMIDADE.GOV/BUILDINGCODE/PC-SEARCH.HTM | | | (F) THE SUBMITTED 2 PAGE COPY EXTRACT OF | | | THE 48 PAGE GAF MODIFIED BITUMEN ROOF | | | PRODUCT APPROVAL NOA# 00-0331.09 DOES | | | NOT INCLUDE A STATEMENT OF THE MAXIMUM | | | DESIGN PRESSURE AND STATES THAT "ALL | | | GENERAL AND SYSTEM LIMITATIONS SHALL | | | APPLY".SUBMIT COPIES OF THE SHEETS | | | WHICH STATE THE GENERAL AND SYSTEM | | | LIMITATIONS AND THE MAX DESIGN PRESSURE. | | | COPIES OF MIAMI-DADE PRODUCT APPROVALS | | | CAN BE PRINTED FROM THEIR WEBSITE,WWW. | | | MIAMIDADE.GOV/BUILDINGCODE/PC-SEARCH.HTM | | | | | | 9) FBC* TABLE 2306.1STRUCTURAL NOTES, | | | SHEET STR-GN, PLYWOOD ROOF DECKING. | | | CONTRARY TO THE G.D. KLIEGER RESPONSE, | | | THE ARCHITECTURAL PLANS SPECIFY PLYWOOD. | | | DETAIL 6/A1-8.1 MAKES SPECIFIC REFERENCE | | | TO "STRUCTURAL DRAWINGS FOR ATTACHMENT/ | | | NAILING PATTERN".AMEND THE THE NOTES | | | AS DESCRIBED IN COMMENT #8 UNDER PERMIT# | | | 02102206 (FOR BUILDING 5, EDUCATIONAL). | | | | | | 10) INFORMATIVE: | | | WOOD TRUSSES.G.D KLIEGER RESPONSE IS | | | NOTED.THE COMMENT WAS ORIGINALLY MADE | | | WHEN THE ARCHITECTURAL PLANS (NOTE 22 ON | | | SHEETS A1-7.1, A1-9.1 AND 9.2) STILL | | | MADE REFERENCE TO WOOD TRUSSES. ALL | | | STRUCTURAL SHOP DRAWINGS SHALL BE | | | REVIEWED AND STAMPED BY THE ENGINEER OF | | | RECORD PRIOR TO SUBMITTAL TO WPB | | | CONSTRUCTION SERVICES DEPT. | | | | | | 15) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-01-08 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-01-08 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-01-08 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2003-01-08 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) FBC* 104.2.4A SIGNED AND SEALED | | | SURVEY DRAWING IS REQUIRED. | | | | | | 2) FL. ADMIN. CODE 61G1-16.003EACH | | | ARCHITECTURAL PLAN SHEET SHALL BE SIGNED | | | PERSONALLY, NOT SIGNATURE STAMPED. | | | | | | 3) INFORMATIVE: | | | A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 4) INFORMATIVE: | | | IMPACT FEES MUST BE PAID TO PALM BEACH | | | COUNTY, THE PLANS STAMPED BY THEM AND A | | | COPY OF THE RECEIPT SUBMITTED TO THE | | | CITY OF WEST PALM BEACH CONSTRUCTION | | | SERVICES DEPARTMENT BEFORE A BUILDING | | | PERMIT CAN BE ISSUED. | | | | | | 5) FBC 11-4.1.2THE BUILDING SHALL BE | | | SERVED BY AT LEAST ONE ACCESSIBLE ROUTE | | | FROM THE ACCESSIBLE PARKING. | | | ACCEPTABILITY OF THESE PLANS IS | | | CONTINGENT UPON THE CIVIL/SITE PLANS, | | | PERMIT# 02102208, BEING PERMITTED. | | | | | | 6) FBC 13-103.0ENERGY CODE COMPLIANCE | | | SHALL BE DEMONSTRATED BY SUBMITTAL OF | | | APPROPRIATE CODE COMPLIANCE FORMS | | | | | | 7) SUBMIT PRODUCT APPROVALS FOR THE | | | ROOFING, EXTERIOR DOORS AND WINDOWS. | | | | | | 8) FBC 1403.9ELEVATION SHEETS A1-5.1 & | | | A1-5.2.4" VINYL SIDING IS SPECIFIED IN | | | NOTE 2.RIGID VINYL SIDING IS LIMITED | | | TO TYPE VI CONSTRUCTION.FROM TABLE 500 | | | THE AREA OF THIS BUILDING EXCEEDS THE | | | ACCEPTANCE CRITERIA FOR TYPE VI | | | CONSTRUCTION. | | | | | | 9) FBC* TABLE 2306.1STRUCTURAL NOTES, | | | SHEET STR-GN, PLYWOOD ROOF DECKING.THE | | | PERIMETER ZONE AT THE GABLE ENDS SHALL | | | HAVE NAILS SPACED AT 4"O.C. MAXIMUM, TO | | | A DISTANCE OF 5 FEET (NOT 24") FROM THE | | | EDGE OF THE ROOF. | | | | | | 10) STRUCTURAL NOTES, SHEET STR-GN, WOOD | | | TRUSS NOTE 6.IT IS NOTED THAT THE | | | TRUSS DESIGN ENGINEER IS TO PROVIDE THE | | | WIND UPLIFT REACTIONS.THE PERMIT | | | CANNOT BE ISSUED UNTIL THE REACTIONS ARE | | | SPECIFIED ON THE PLANS FOR CROSS | | | REFERENCE AGAINST THE PROPOSED TRUSS | | | ANCHORS AND STRAPS. | | | | | | 11) FBC 11-4.9.4(2)SHEET A1-8.1, TYP. | | | SIDE WALL RAILING DETAIL (ALSO SHEET | | | A1-9.1 STAIR 109/209 SECTION).THE | | | HANDRAIL SHALL EXTEND AT LEAST 12" | | | HORIZONTALLY BEYOND THE TOP RISER, AND | | | SHALL CONTINUE TO SLOPE PAST THE BOTTOM | | | RISER FOR A DISTANCE EQUAL TO THE WIDTH | | | OF ONE TREAD AND THEN A FURTHER 12" | | | HORIZONTALLY AT THE BOTTOM. | | | | | | 12) FBC 11-4.13.6MANEUVERING CLEARANCE | | | AT DOORS.THE LEADING EDGE OF DOOR 202B | | | SHOULD BE NO LESS THAN 18" AWAY FROM THE | | | CORRIDOR WALL ON THE PULL SIDE OF THE | | | DOOR. | | | | | | 13) FBC 11-4.16.3SHEET A1-2.41, DETAIL | | | 5A AND SHEET A1-4.1, DETAIL 2A, 2B, 4A. | | | THE HEIGHT OF THE W.C. SEAT SHOULD BE | | | 17" TO 19", NOT 1'-3". | | | | | | 14) FBC 2405.2THE GLAZED PANEL AT HR | | | RECEPTION IS WITHIN 24" OF DOOR 103. | | | THIS IS A 'HAZARDOUS LOCATION' AND IS | | | REQUIRED TO BE SAFETY GLASS SATISFYING | | | THE REQUIREMENTS OF THE CONSUMER PRODUCT | | | SAFETY COMMISSION 16, CODE OF FEDERAL | | | REGULATIONS, PART 1201 (CPSC 16-CFR, | | | PART 1201).SUBMIT DETAILS TO | | | DEMONSTRATE COMPLIANCE. | | | | | | 15) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-28 |
Time |
06:31 |
Rev Time |
0.20 |
| Received By |
dpalmer |
Date |
2005-02-28 |
Time |
06:23 |
Sent To |
|
|
| Notes |
| 2005-02-28 00:00:00 | ****** PROVISO ********* | | | | | | | | | | | | PURSUANT TO DECISION BY THE AHJ AND | | | BUILDING OFFICAL, ALL ELECTRICAL WORK TO | | | BE PERFORMED UNDER THE 2002 NEC. | | | PLANS ARE TO BE REVISED BEFORE ROUGH FOR | | | ANY CHANGES AFFECTING DESIGN. | | | | | | | | | PLEASE REVISE AND SUBMIT FOR REVIEW | | | BEFORE ROUGH ELECTRICAL INSPECTION. | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | | NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2004-03-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-03-02 |
Time |
08:40 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-03-02 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2004-03-02 00:00:00 | ** UNSAT ** | | | | | | 1)NOTE: PLEASE INCLUDE NAME, LICENSE# | | | AND CERTIFICATE OF AUTHORIZATION # ON | | | TITLE BLOCK(S). THIS IS REQ'D ON ALL | | | SHEETS AND FOR ALL TRADES. | | | PLEASE SEE FAC 61G15-23.002, FS 471.023 | | | THIS MAY BE HAND WRITTEN ON ALL SHEETS. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-02 |
Time |
18:07 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-10-02 |
Time |
18:07 |
Sent To |
|
|
| Notes |
| 2003-10-02 00:00:00 | PLANS OK AND STAMPED 5-15-03 | | | NO RESUBMITTIAL SHEET FOUND TO SIGN OFF. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-05-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-15 |
Time |
08:39 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-05-15 |
Time |
08:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-03-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-27 |
Time |
16:37 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2003-03-27 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2003-03-27 00:00:00 | ************* UNSAT ************ | | | | | | 1)NOTE: PLEASE SHOW GROUNDING ELECTRODE | | | SYSTEM. IT IS NOTED ON RISER THAT | | | GROUNDIGN ELECTRODE DETAIL IS ON SHEET | | | E3.01? PLEASE NOTE, NO SHEET 3.01 WAS | | | SUBMITTED FOR REVIEW.? | | | PLEASE ALSO SHOW GROUNDING DETAIL OR | | | NOTED WHERE TRANSFORMERS WILL BE | | | ATTACHED? BLDG STEEL/FOOTER? 250-30 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-26 |
Time |
05:47 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2002-11-25 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2002-11-26 00:00:00 | ****************UNSAT ************** | | | | | | 1)NOTE: PLEASE SHOW LOCATION OF SERVICE/ | | | 1MDP.SHOWN ON RISER IN RM 126?? | | | PLEASE NOTE, THIS IS CLARIFY DISTANCE | | | FROM MDP TO PRIMARY SIDE OF TRANSFORMERS | | | PLANS/LINE DIAGRAM DOES NOT SHOW HOW FAR | | | AWAY.? TAPPED CONDUCTORS 240-21 | | | | | | 2)NOTE: PLEASE CLARIFY PANEL SCHEDULE | | | FOR 1L/B? PLEASE NOTE THERE IS ANOTHER | | | PANEL SCHEDULE SHOWN. MISPRINT? | | | | | | 3)NOTE: PLEASE NOTE, RISER DIAGRAM SHOWS | | | THE "GUARDHOUSE" PANEL AS 120/240V AND | | | BEING FROM MDP WHICH IS 277/480V? | | | PLEASE CLARIFY. | | | | | | 4)NOTE: PLEASE SHOW GROUNDING ATTHE | | | DEATCHED "GH". PER 250-32 | | | | | | 5)NOTE: PLEASE SHOW LOCATIONS FOR | | | GROUNDING OF TRANSFORMERS PER 250-30. | | | | | | 6)NOTE: PLEASE SEE NOTE GROUNDING | | | ELECTRODE SYSTEM BELOW MDP, NOTE MENTION | | | -S, "SEE GROUNDING DETAIL THIS SHEET"?? | | | PLEASE CLARIFY WHERE THIS DEATIL CAN BE | | | FOUND. ALSO MENTIONS "ALL SERVICES TO | | | BE BONDED TOGETHER? PLEASE NOTE, ONLY | | | ONE SERVICE IS SHOWN. ?? | | | | | | 7)NOTE: PLEASE CLARIFY THE MDP HAS | | | A MCB THE MEETS 230-76 AND 230-79. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRCIAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2003-06-25 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-06-25 |
Time |
10:39 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-06-25 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2003-06-25 00:00:00 | PASSED : | | | 1. SEE PERMIT # 02102208 FOR UNDERGROUND | | | UTILITIES AND SITE WORKS. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2003-03-17 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-03-17 |
Time |
10:37 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-03-17 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2003-03-17 00:00:00 | FAILED: | | | 1. SEE REVIEW COMMENTS, PERMIT #02102208 | | | DATED 03-17-03. | | | IF ANY QUESTION PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2002-11-06 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-11-06 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
mamini |
Date |
2002-11-06 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2002-11-06 00:00:00 | FAILED: | | | 1. SEE REVIEW COMMENTS FOR PLAN REVIEW # | | | 02102208. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-11-03 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-11-03 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-11-03 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2003-11-03 00:00:00 | PLANS OK APPROVED ON 04-24-03 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-04-24 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-04-24 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-04-24 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2003-04-24 00:00:00 | ***********PROVISO********************** | | | 1) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE ALARM SYSTEM. | | | | | | NATE MCCRAY, CAPTAIN | | | 659-8096, EXT 8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-12-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-12-04 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-12-04 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2002-12-04 00:00:00 | 1) BUILDING ADDRESS REQUIRED. | | | | | | 2) ELEVATOR ROOM DOOR APPEARS TO | | | SWING TOO FAR INTO CORRIDOR 149. | | | | | | 3) AGAIN WILL GUARD HOUSE BE STAFFED | | | FULL TIME. | | | | | | 4) ALL SHAFTWAYS IN WHICH ARE LARGE | | | ENOUGH FOR PERSONS TO FALL INTO | | | MUST BE MARKED SHAFTWAY MUST BE MARKED | | | SHAFTWAY IN SIX INCH HIGH LETTERS WITH | | | A WHITE BACKGROUND. | | | | | | 5) PLEASE PROVIDE THIS OFFICE WITH | | | A LIFE SAFETY PLAN INDICATING OCCUPANT | | | LOADS, TRAVEL DISTANCES, ETC. | | | | | | 6) PLEASE PROVIDE SEPARATE PLANS AND | | | PERMITS FOR FIRE ALARM AND FIRE | | | SPRINKLER SYSTEMS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-02-24 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2005-02-03 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-02-03 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2005-02-24 00:00:00 | PLANS ON RACK (COMMERCIAL BOARD #17) |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-02-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-06 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-06 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2004-02-06 00:00:00 | TO COMM BD#45 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-06-06 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-05 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2003-05-05 00:00:00 | COMM BOARD #12,PLANS NEXT TO CONF ROOM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-03-13 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-13 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-13 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2003-03-14 00:00:00 | COMM BOARD #46 | | | PLANS ON RACK, 1ST & 2ND SHELF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-05-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-05-10 |
Time |
12:05 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-05-10 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2003-05-10 00:00:00 | MECHANICAL PERMIT 03050133 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2003-04-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-04-03 |
Time |
13:04 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-04-03 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2003-04-03 00:00:00 | PLEASE CLARIFY "SHAFTWAY" INDICATED ON | | | PLAN SHEET A1-2.21.DOES THIS HAVE | | | A "RATING"?PLEASE NOTE, EXHAUST DUCT | | | IN "SHAFTWAY" SHALL COMPLY WITH 2001 | | | FBC(M) 607.1.2 #1 OR 2. | | | | | | PLEASE PROVIDE OUTSIDE AIR CALCS AS PER | | | 2001 FBC(M) TABLE 403.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-12-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-12-03 |
Time |
14:33 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2002-12-03 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2002-12-03 00:00:00 | ADMINISTRATION BUILDING #1 | | | DENIED: | | | | | | 1) PLAN SHEET M1-2.02 HVAC KEYNOTES #6, | | | "ROUTE 3/4" CONDENSATE DRAIN TERMINATE | | | AT RAIN LEADER."CONDENSATE SHALL BE | | | TO A DEDICATED LINE & TERMINATE INTO | | | STORM OUTSIDE OF BUILDING.PLEASE | | | CLARIFY. | | | | | | 2) FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | | SHALL HAVE NOTIFICATION TO ALARM/STROBE | | | IN NORMALLY OCCUPIED AREAS OR A SUPER- | | | VISORY SIGNAL AT A CONSTANTLY ATTENDED | | | LOCATION.NFPA 90A 4-4.4.3 & 4-4.4.2. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-06-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-07 |
Time |
14:31 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-06-07 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-03-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-28 |
Time |
15:31 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-03-28 |
Time |
15:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-12-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-12-03 |
Time |
10:54 |
Rev Time |
3.50 |
| Received By |
kstevens |
Date |
2002-12-02 |
Time |
18:52 |
Sent To |
|
|
| Notes |
| 2002-12-03 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A1-4.1 DETAIL #1 SHOWS 5'2" WIDTH | | | FOR TOILET ROOM AND STALL. MINIMUM 5'3" | | | IS REQUIRED FOR BOTH. | | | 2) SHT A1-4.2 DETAIL #10A BREAK ROOM | | | SINK SHALL COMPLY WITH SECTION 11-4.24, | | | AND ALL SUBSECTIONS. PLEASE SHOW ON DE- | | | TAIL KNEE CLEARANCE, CLEAR FLOOR SPACE, | | | ECT. | | | 3) SHT A1-4.3 DETAILS #5 & 9, PLEASE | | | SHOW CLEAR FLOOR SPACE. IF FRONTAL APP- | | | ROACH SHOW DETAILS FOR COMPLIANCE WITH | | | SECTION 11-4.24 AND ALL SUBSECTIONS. IF | | | PARALLEL APPROACH, SHOW ON PLANS. SINK | | | TO BE CENTERED ON 48". | | | 4) SHTS P1-2.02 & P1-3.01 ICE MAKER | | | DRAIN, 2ND FLOOR PLUMBING PLAN AND SANT. | | | RISER DIAGRAM, ALL INDIRECT WASTE SHALL | | | DRAIN INTO A FLOOR SINK. SEC 802.3 | | | 5) SHT P1-3.02 BACKFLOW REQUIRED ON | | | WATER SERVICE TO ADMIN. BLDG. | | | 6) SHT P1-3.02 WATER RISER DIAGRAM, | | | WATER HAMMER ARRESTORS REQUIRED BY SEC. | | | 604.9 SHALL BE LOCATED NEAR FIXTURES IN | | | AN "EFFECTIVE RANGE" NOT AT TOP OF DROP | | | AS SHOWN FOR 1ST FLOOR. PER PDI-WH 201 & | | | MANUF. INSTALLATION INSTRUCTIONS. | | | 7) SHT P1-4.01 WATER HEATER DETAIL/WATER | | | HEATER SCHEDULE. W/H DETAIL SHOWN P/T & | | | PAN DRAIN DRAINING TO JANITOR SINK, BUT | | | W/H SCHEDULE SHOWS P/T & PAN DRAIN DRAIN | | | ING INTO FLOOR DRAIN. (NOT APPROVED) | | | PLEASE CLAIRFY. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-06-06 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-06-06 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-01-13 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-01-13 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-01-13 00:00:00 | DENIED, NEED MINOR AMENDMENT AND THE | | | PLAT NEED TO BE RECORDED |
|
|