| Plan Review Stops For Permit 02102183 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-12-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-30 |
Time |
07:13 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2002-12-30 |
Time |
07:13 |
Sent To |
|
|
| Notes |
| 2002-12-30 00:00:00 | PLANS OK. | | | CONTRACTOR NEEDS TO COME IN AND TAKE | | | ALL OLD/VOIDED SHEETS OUT AND MAKE TWO | | | COMPLETE SETS AND PLACE ALL VOIDED SHEET | | | S IN THIRD SET. | | | | | | IF THERE ARE ANY QUESTIONS , PLEASE CALL | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-14 |
Time |
09:42 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2002-11-14 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2002-11-14 00:00:00 | **************** UNSAT ************* | | | | | | 1)NOTE: PLEASE NOTE PLANS MUST BE SIGNED | | | DTAED AND SEALED BY THE ENGINEER OF | | | RECORD. REQ`D PER FS/FAC 471.025, | | | 471.003 H 1/ FBC 104.4.1.3 | | | FOR 277/480V | | | | | | 2)NOTE: PLEASE NOTE ALL CONTINUOUS LOADS | | | ARE TO BE SHOWN AT 125%. 215-3,230-42 | | | ETC. | | | | | | 3)NOTE: PLEASE SHOW CALCULATIONS FOR | | | TRACK LIGHTING PER 220-12B. | | | | | | 4)NOTE: PLEASE CLARIFY HOW 700-12 IS MET | | | | | | 5)NOTE: PLEASE SHOW ALL CIRCUIT ON PLANS | | | AND CORRELATE WITH PANEL SCHEDULE. | | | | | | 6)NOTE: PLEASE CLARIFY LOCATIONS OF MAIN | | | -S. GROUPING OF MAINS PER 230-72 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-01-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-01-02 |
Time |
19:01 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-01-02 |
Time |
19:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-11-14 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-11-14 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-11-14 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2002-11-14 00:00:00 | 1) PLANS INDICATE THE INSTALLATION OF | | | AN ADDITIONAL FIRE ALARM CONTROL PANEL. | | | NO NEW ADDITIONAL FIRE ALARM PANELS | | | WILL BE ALLOWED TO BE INSTALLED WITHIN | | | TENANT SPACES. FIRE ALARM EQUIPMENT MUST | | | BE CONNECTED WITHIN THE TENANT SPACE | | | TO THE BASE BUILDING FIRE ALARM PANEL. | | | EXISTING SUB FIRE ALARM CONTROL PANELS | | | HAVE CAUSED SIGNIFICANT PROBLEMS. | | | PLEASE DELETE THIS ITEM FROM THE | | | PLANS AND REVISE AS NECESSARY. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-01-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-09 |
Time |
18:12 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-01-09 |
Time |
18:12 |
Sent To |
|
|
| Notes |
| 2003-01-09 00:00:00 | PROCESSED PLANS, TOOK OUT OLD SHEETS | | | MADE TWO NEW SETS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2002-12-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-10 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-12-10 |
Time |
17:34 |
Sent To |
|
|
| Notes |
| 2002-12-10 00:00:00 | COMM BOARD #47./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-04 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-10-31 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2002-11-04 00:00:00 | TO COMM BOARD . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-12-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-12-27 |
Time |
15:45 |
Rev Time |
1.45 |
| Received By |
pkrauss |
Date |
2002-12-27 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2002-12-27 00:00:00 | PROVISO: | | | | | | 1.AHU UNIT ACCESS PRIOR TO COMMENCING | | | WORK CLARIFY SAFETY FOR SERVICING. WILL | | | THERE BE SUFFICIENT CLEARANCE FOR | | | REPLACMENT OF THE COILS & FAN MOTORS? | | | 2001 FBC(M) 306.1. | | | | | | RESPONSE TO COMMENTS 3, 4, & 5 OKAY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-11-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-11-14 |
Time |
13:28 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2002-11-14 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2002-11-14 00:00:00 | DENIED: | | | | | | CLARIFY ACCESS FOR MAINTENANCE, SERVICE | | | OR REPLACEMENT OF THE AHU'S AND ITS | | | COMPONENTS.2001FBC(M) 306.1 | | | | | | INDICATE ELEVATION OF AHU'S. | | | | | | PROVIDE MANUFACTURER SUBMITTAL DATA ON | | | THE STANDS FOR THE CONDENSER UNITS. | | | SHOW COMPLIANCE WITH 2001 FBC TABLE | | | 1511.7 - MINIMUM HEIGHT REQUIREMENT FROM | | | ROOF SURFACE.SHOW ACCESS TO CONDENSER | | | UNITS LOCATED ON THE ROOF. | | | | | | ADDITIONAL PERMIT REQUIRED FOR WALK IN | | | COOLERS OR FREEZERS. PROVIDE SUBMITTAL | | | DATA FROM MANUFACTURER. SHOULD CONDENSER | | | UNIT BE REMOTE, SHOW LOCATION OF C.U. | | | | | | INDENTIFY CONDENSATE TERMINATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-12-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-12-30 |
Time |
09:22 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2002-12-30 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2002-12-30 00:00:00 | PASSED/PROVISO | | | | | | RPZ BACKFLOW REQUIRED - MANUF. INFO. FOR | | | NSF COMPLIANCE FOR FILTER SHALL BE ON | | | JOB FOR FINAL - FLOOR SINK REQUIRED AT | | | WATER HEATER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-11-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-11-18 |
Time |
15:16 |
Rev Time |
3.00 |
| Received By |
kstevens |
Date |
2002-11-18 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2002-11-18 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A1.3 SECTION 11-4.22.4 IF TOILET | | | STALLS ARE PROVIDED, THAN AT LEAST ONE | | | SHALL BE A STANDARD TOILET STALL COMPLY- | | | ING WITH 11-4.17. EACH TOILET ROOM SHALL | | | COMPLY. | | | 2) SHT A10.3 TYPICAL WATERPROOF MENBRANE | | | DETAIL. AN ENGINEERED - SIGNED, SEALED, | | | AND DATED SUBMITTAL OF WATERPROOFING DE- | | | TAIL IS REQUIRED. | | | 3) SHTS. P.1 & P.2, ALL INDIRECT WASTE | | | SHALL DRAIN INTO A FLOOR SINK. SEC 802.3 | | | FLOOR DRAINS ARE NOT AN APPROVED IN- | | | DIRECT WASTE RECEPTOR. FLOOR SINKS SHALL | | | BE LOCATED AS NOT TO PRESENT A TRIPPING | | | HAZARD. | | | 4) SHT P.3 RISER NOTE #6, ALL WATER | | | FILTERS SHALL BE "NSF" APPROVED. PLEASE | | | SUBMIT MANUF. INFO. | | | 5) SHT P.5 FLOOR DRAIN SPECIFICATIONS, | | | FD-3, FLOOR DRAINS NOT APPROVED FOR IN- | | | DIRECT WASTE. ALL INDIRECT WASTE SHALL | | | BE DRAINED TO A FLOOR SINK. (SEE REVIEW | | | COMMENT #3). | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|