Plan Review Details - Permit 02102172
Plan Review Stops For Permit 02102172
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-02-28 Cont ID  
Sent By jwitmer Date 2003-02-28 Time 10:23 Rev Time 0.33
Received By jwitmer Date 2003-02-28 Time 10:22 Sent To  
Notes
2003-02-28 00:00:00REVISION # 1 1/20/03 OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-01-08 Cont ID  
Sent By btrobaug Date 2003-02-28 Time 09:44 Rev Time 0.00
Received By jwitmer Date 2003-01-08 Time 10:22 Sent To  
Notes
2003-01-08 00:00:00 
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 02122172
 ADDRESS: 1204 FLORIDA AVE
 CONT: 0/B PULLENS, WALTER
 TELL # (561) 863-7647
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 *****PROVISO*****
  
 1) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.MISSING REPORT:
 A) STORM SHUTTERS
 PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
 PROVIDE BEFORE BUCK INSPECTION.
  
 2)1503.4.2 OVERFLOW DRAINS SHALL BE
 THE SAME SIZE AS ROOF DRAINS, INSTALLED
 WITH THE INLET FLOW LINE LOCATED 2"
 ABOVE THE LOWEST POINT OF THE ROOF LINE.
 OVERFLOW SCUPPERS SHALL BE A MINIMUM OF
 4"IN HEIGTH AND SHALL BE PLACED IN WALLS
 OR PARARETS WITH THE INLET FLOW LINE
 NOT LESS THAN 2" ABOVE THE ROOF SURFACE.
  
 3)1203.4.2 EVERY TOLIET ROOM SHALL
 HAVE WINDOWS AS SPECIFIED FOR HABITABLE
 ROOMS PROVIDING IN NO CASE LESS THAN 3
 SQ FT OPEN SPACE, OR HAVE APPROVED EQUIV
 ALENT VENTILATION. THE MECHANICAL CODE
 REQUIRES AN EXHAUST FAN EVEN WITH WINDOW
 SEE MECH TABLE 403.3.EXHAUST REQUIRED &
 RECIRCULATION OF AIR IS PROHIBITED.
 4) PROVIDE INFORMATION FOR DECK SECTION,
 HOW 2X12 ARE TO ATTACH TO 4X4 POST?
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-04-15 Cont ID  
Sent By btrobaug Date 2003-04-15 Time 12:56 Rev Time 1.00
Received By btrobaug Date 2003-04-15 Time 12:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-02-28 Cont ID  
Sent By shernand Date 2003-04-07 Time 09:24 Rev Time 0.50
Received By btrobaug Date 2003-02-28 Time 09:00 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-01-07 Cont ID  
Sent By kstevens Date 2003-02-27 Time 18:38 Rev Time 0.50
Received By btrobaug Date 2003-01-07 Time 11:40 Sent To B
Notes
2003-01-07 00:00:00TO JIM W./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-04-07 Cont ID  
Sent By shernand Date 2003-04-07 Time 09:23 Rev Time 0.00
Received By shernand Date 2003-04-07 Time 09:23 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-02-11 Cont ID  
Sent By dpalmer Date 2003-02-11 Time 13:36 Rev Time 0.00
Received By dpalmer Date 2003-02-11 Time 13:36 Sent To P
Notes
2003-02-11 00:00:00TO PLUMB INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-10-31 Cont ID  
Sent By dpalmer Date 2002-10-31 Time 12:44 Rev Time 0.00
Received By dpalmer Date 2002-10-31 Time 12:44 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-01-08 Cont ID  
Sent By jwitmer Date 2003-01-08 Time 08:16 Rev Time 0.25
Received By jwitmer Date   Time   Sent To  
Notes
2003-01-08 00:00:00PROVISO: PROVIDE EXHAUST FAN IN NEW
 BATH PER 403.3 EXHAUST REQUIRED, RECIR-
 CULATION OF AIR PROHIBITED!

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-02-27 Cont ID  
Sent By kstevens Date 2003-02-27 Time 18:37 Rev Time 0.33
Received By kstevens Date 2003-02-27 Time 18:37 Sent To E
Notes
2003-02-27 00:00:00REVISION OK - ADD SCUPPERS ON ROOF

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-01-08 Cont ID  
Sent By dpalmer Date 2003-02-11 Time 13:36 Rev Time 0.50
Received By kstevens Date 2003-01-08 Time 16:49 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-11-13 Cont ID  
Sent By dpalmer Date 2002-10-31 Time 12:44 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***