Plan Review Details - Permit 02101951
Plan Review Stops For Permit 02101951
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-12-23 Cont ID  
Sent By btrobaug Date 2002-12-21 Time 11:25 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
2002-12-23 00:00:00PROVISO NEED CONTRACT TO VERIFY VALUE

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-12-21 Cont ID  
Sent By kstevens Date 2002-12-19 Time 17:57 Rev Time 0.25
Received By btrobaug Date 2002-12-21 Time 11:20 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2002-12-04 Cont ID  
Sent By btrobaug Date 2002-12-04 Time 15:28 Rev Time 0.00
Received By btrobaug Date 2002-12-04 Time 15:28 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-10-30 Cont ID  
Sent By btrobaug Date 2002-10-30 Time 18:04 Rev Time 0.00
Received By btrobaug Date 2002-10-30 Time 18:04 Sent To Z
Notes
2002-10-30 00:00:00TO Z IN BOX./WRT.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-01-17 Cont ID  
Sent By kstevens Date 2003-01-17 Time 18:44 Rev Time 0.33
Received By kstevens Date 2003-01-17 Time 18:44 Sent To  
Notes
2003-01-17 00:00:00NEW PERIT TO FINAL OUT EXISTING WORK
 FROM 0008O747 STANDARD CODE.

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-12-19 Cont ID  
Sent By sgraham Date 2002-12-17 Time 10:49 Rev Time 0.50
Received By kstevens Date 2002-12-19 Time 17:46 Sent To E
Notes
2002-12-19 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS. (ADD TO NOTES)
 2) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-4 92, AND NSPI-5. (ADD TO
 NOTES)
 3) FBC-2001 SEC 424.2.6.6 ENTRAPMENT
 PROTECTION FOR SUCTION INLETS. (DETAIL)
 4) FBC-2001424.2.6.6.3 (1,2,3) ENTRAP-
 MENT AVOIDANCE. (DETAIL)
 5) FBC-2001424.2.6.6.4 MINIMUM OF TWO
 SUCTION INLETS SHALL BE PROVIDED FOR EA
 PUMP. SEPARATED BY A MINIMUM OF 3 FEET
 OR LOCATED ON TWO DIFFERENT PLANES.
 (DETAIL)
 6) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 7) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 8) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 9) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 10) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
 11) FBC-2001 424.2.14.4 CONNECTIONS, ALL
 WATER HEATING EQUIPMENT SHALL BE INSTAL-
 LED WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER. (ADD TO NOTES)
 12) FBC02001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 2 Status P Date 2002-12-17 Cont ID  
Sent By sgraham Date 2002-12-17 Time 10:49 Rev Time 0.25
Received By sgraham Date   Time   Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-12-12 Cont ID  
Sent By btrobaug Date 2002-12-04 Time 15:28 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-11-13 00:00:00NEED SURVEY