Plan Review Details - Permit 02101889
Plan Review Stops For Permit 02101889
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-02-11 Cont ID  
Sent By btrobaug Date 2003-02-11 Time 17:11 Rev Time 0.50
Received By btrobaug Date 2003-02-11 Time 17:11 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-12-31 Cont ID  
Sent By btrobaug Date 2003-01-31 Time 17:32 Rev Time 0.50
Received By btrobaug Date 2002-12-30 Time 18:28 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-11-19 Cont ID  
Sent By hmoser Date 2002-11-14 Time 18:12 Rev Time 1.00
Received By btrobaug Date 2002-11-19 Time 07:02 Sent To R
Notes
2002-11-19 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE PROVIDE THE FOLLOWING
 INFORMATION,MAKE ANY NECESSARY CHANGES
 TO THE PLANS AND RESUBMIT FOR REVIEW.
  
 1} PLEASE LIST THE REQ'D BATH(S)
 CIRCUIT(S). PER 210-11-C-3
 MUST BE 20A AND #12AWG.,ON THE PANEL
 SCHEDULE.
  
 2} NOTE THE LAUNDRY CIRCUIT IS TO BE
 CALCULATED AT 1500 VA PER 220-16.
  
 3} PLEASE GIVE A PANEL SCHEDULE FOR
 PANEL"C",AND GIVE LOCATION OF SAME.
  
 4} THE SMOKE DETECTOR IN THE KITCHEN IS
 IN VIOLATION OF 8-1.4.2 NFPA-72.(A HEAT
 DETECTOR WOULD BE PERMISSIBLE).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-01-31 Cont ID  
Sent By btrobaug Date 2003-01-31 Time 17:32 Rev Time 0.00
Received By btrobaug Date 2003-01-31 Time 17:32 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2002-12-27 Cont ID  
Sent By dpalmer Date 2002-12-27 Time 14:34 Rev Time 0.00
Received By dpalmer Date 2002-12-27 Time 14:34 Sent To E
Notes
2002-12-27 00:00:00TO BILL T`S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-10-30 Cont ID  
Sent By btrobaug Date 2002-10-30 Time 17:25 Rev Time 0.00
Received By btrobaug Date 2002-10-30 Time 17:25 Sent To Z
Notes
2002-10-30 00:00:00TO Z IN BOX./WRT

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-02-18 Cont ID  
Sent By pkrauss Date 2003-02-18 Time 09:25 Rev Time 0.30
Received By pkrauss Date 2003-02-18 Time 09:11 Sent To R
Notes
2003-02-18 00:00:00MECH REV PERMIT 02101928

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-01-06 Cont ID  
Sent By btrobaug Date 2003-02-11 Time 17:13 Rev Time 0.40
Received By pkrauss Date 2003-01-06 Time 16:05 Sent To  
Notes
2003-01-06 00:00:00MECHANICAL PERMIT 02101928
 FAN SHUTDOWN REQUIRED AT FINAL
 INSPECTION.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-11-14 Cont ID  
Sent By btrobaug Date 2002-12-31 Time 09:27 Rev Time 0.33
Received By hmoser Date 2002-11-14 Time 18:11 Sent To R
Notes
2002-11-14 00:00:00PLAN DENIED
 1) NEED FRESHAIR CALCULATIONS
 2) MANUAL (J) NOT COMPLETE
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-11-04 Cont ID  
Sent By jleech Date 2002-11-04 Time 18:28 Rev Time 0.33
Received By jleech Date 2002-11-04 Time 18:28 Sent To  
Notes
2002-11-04 00:00:00PROVISO;
 REVISED RISER DIAGRAM REQUIRED. W/M AND
 L/T MUST TIE INTO THE HORIZONTAL BRANCH
 DRAIN BELOW THE BATHROOM GROUP. SEE FBC
 PLUMBING SEC 909.1.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-12-05 Cont ID  
Sent By pkrauss Date 2003-02-18 Time 09:26 Rev Time 2.50
Received By lhatten Date 2002-12-01 Time 17:35 Sent To  
Notes
2002-12-05 00:00:00REVIEW & PRINT CARDS 12/01/2002
 CALC. FEES & PRINT CARDS 12/05/2002

Review Stop Z ZONING
Rev No 1 Status P Date 2002-11-04 Cont ID  
Sent By btrobaug Date 2002-10-30 Time 17:26 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***