| Plan Review Stops For Permit 02101889 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-02-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-02-11 |
Time |
17:11 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-02-11 |
Time |
17:11 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-12-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-31 |
Time |
17:32 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2002-12-30 |
Time |
18:28 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-11-14 |
Time |
18:12 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2002-11-19 |
Time |
07:02 |
Sent To |
R |
|
| Notes |
| 2002-11-19 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE PROVIDE THE FOLLOWING | | | INFORMATION,MAKE ANY NECESSARY CHANGES | | | TO THE PLANS AND RESUBMIT FOR REVIEW. | | | | | | 1} PLEASE LIST THE REQ'D BATH(S) | | | CIRCUIT(S). PER 210-11-C-3 | | | MUST BE 20A AND #12AWG.,ON THE PANEL | | | SCHEDULE. | | | | | | 2} NOTE THE LAUNDRY CIRCUIT IS TO BE | | | CALCULATED AT 1500 VA PER 220-16. | | | | | | 3} PLEASE GIVE A PANEL SCHEDULE FOR | | | PANEL"C",AND GIVE LOCATION OF SAME. | | | | | | 4} THE SMOKE DETECTOR IN THE KITCHEN IS | | | IN VIOLATION OF 8-1.4.2 NFPA-72.(A HEAT | | | DETECTOR WOULD BE PERMISSIBLE). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/659-8096 EXT. 8392 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-01-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-31 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-31 |
Time |
17:32 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2002-12-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-27 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-12-27 |
Time |
14:34 |
Sent To |
E |
|
| Notes |
| 2002-12-27 00:00:00 | TO BILL T`S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-10-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-30 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-10-30 |
Time |
17:25 |
Sent To |
Z |
|
| Notes |
| 2002-10-30 00:00:00 | TO Z IN BOX./WRT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-02-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-18 |
Time |
09:25 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2003-02-18 |
Time |
09:11 |
Sent To |
R |
|
| Notes |
| 2003-02-18 00:00:00 | MECH REV PERMIT 02101928 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-01-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-02-11 |
Time |
17:13 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-01-06 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2003-01-06 00:00:00 | MECHANICAL PERMIT 02101928 | | | FAN SHUTDOWN REQUIRED AT FINAL | | | INSPECTION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-11-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-31 |
Time |
09:27 |
Rev Time |
0.33 |
| Received By |
hmoser |
Date |
2002-11-14 |
Time |
18:11 |
Sent To |
R |
|
| Notes |
| 2002-11-14 00:00:00 | PLAN DENIED | | | 1) NEED FRESHAIR CALCULATIONS | | | 2) MANUAL (J) NOT COMPLETE | | | PLAN REVIEW BY HAROLD MOSER | | | (561)659-8096 EXT.8390 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-11-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-11-04 |
Time |
18:28 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2002-11-04 |
Time |
18:28 |
Sent To |
|
|
| Notes |
| 2002-11-04 00:00:00 | PROVISO; | | | REVISED RISER DIAGRAM REQUIRED. W/M AND | | | L/T MUST TIE INTO THE HORIZONTAL BRANCH | | | DRAIN BELOW THE BATHROOM GROUP. SEE FBC | | | PLUMBING SEC 909.1. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2002-12-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-18 |
Time |
09:26 |
Rev Time |
2.50 |
| Received By |
lhatten |
Date |
2002-12-01 |
Time |
17:35 |
Sent To |
|
|
| Notes |
| 2002-12-05 00:00:00 | REVIEW & PRINT CARDS 12/01/2002 | | | CALC. FEES & PRINT CARDS 12/05/2002 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-11-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-30 |
Time |
17:26 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|