| Plan Review Stops For Permit 02101739 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2003-11-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-12 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-11-07 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2003-11-07 00:00:00 | SHEET R1 REDLINED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2003-10-29 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-10-29 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-10-29 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2003-10-29 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 9/29/03: | | | | | | 2) IMPACT FEES. THE PLANS SHALL BE TAKEN | | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | | STAMPED AT THAT OFFICE AND A COPY OF THE | | | PAID RECEIPT SUBMITTED TO THE CITY OF | | | WEST PALM BEACH DEPT OF CONSTRUCTION | | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | | | 10) FBC TABLE 1606.2ASHEET R1, TRUSS | | | CONNECTORS/ANCHORS. | | | F) ANCHOR MARK A3 (ALSO APPLIES TO | | | ANCHOR MARKS A1 AND A2 BUT THEY ARE NOT | | | CRITICAL).ACCCORDING TOTHE USP | | | CATALOGUE THE TAPL16 SHALL HAVE | | | (6)10D X 1-1/2" NAILS TO THE SEAT PLATE | | | AND (13)10D NAILS TO THE TRUSS IN ORDER | | | TO GENERATE IT'S MAX. ALLOWABLE | | | CAPACITIES OF UPLIFT = 1350 LBS, LATERAL | | | F1 = 595 LBS AND F2 = 880 LBS.THE | | | SUBMITTED ANCHOR SCHEDULE CLAIMS AN | | | UPLIFT CAPACITY OF 1360 LBS AND LATERAL | | | LOADS OF 1105 LBS WITH ONLY (14)10D | | | NAILS INTO THE TRUSS. AMEND THE SCHEDULE | | | (AMEND ALSO FOR ANCHOR MARKS A4, A5 & A6 | | | SEE COMMENT BELOW). | | | G) ANCHOR MARK A4, A5 AND A6.THE USP | | | TAPL16 IS ALSO SPECIFIED, FOR THESE | | | CONNECTORS, BUT USED IN COMBINATION WITH | | | TA16 ANCHORS.AMEND THE SCHEDULE (SEE | | | THE ABOVE COMMENT).ALSO THE USP | | | CATALOGUE DOES NOT HAVE A CAPACITY TABLE | | | FOR THESE ANCHORS COMBINED.JUSTIFY THE | | | STATED CAPACITIES OR SPECIFIY | | | ALTERNATIVE ANCHORS. | | | | | | 32) THIS COMMMENT HAS NOT BEEN ADDRESSED | | | FBC 1606.1.7THE PLANS STILL DO NOT | | | STATE THE DESIGN WIND PRESSURE ON THE | | | ROOF COVERING (COMPONENTS AND CLADDING) | | | FOR SELECTION OF A APPROPRIATE ROOF | | | COVERING SYSTEM.ANNOTATE THE PLANS. | | | | | | 34) NOTICE OF COMMENCEMENT.SEE THE | | | COMMENT ON PREVIOUS REVIEW. | | | | | | 35) HISTORIC.SEE THE COMMENT ON | | | PREVIOUS REVIEW. | | | | | | 36) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2003-09-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-29 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-09-29 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2003-09-29 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | NO BUILDING PLAN REVIEW CARRIED OUT AT | | | REV. #5. | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 8/12/03: | | | | | | 2) IMPACT FEES. THE PLANS SHALL BE TAKEN | | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | | STAMPED AT THAT OFFICE AND A COPY OF THE | | | PAID RECEIPT SUBMITTED TO THE CITY OF | | | WEST PALM BEACH DEPT OF CONSTRUCTION | | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | | | 10) FBC TABLE 1606.2ASHEET R1, TRUSS | | | CONNECTORS/ANCHORS: | | | A) "MSTA 60 HURRICANE CLIPS".MSTA 60 | | | AND MSTA TAPL 16 ARE NOT VALID USP | | | REFERENCES.ASSUMING THE INTENDED | | | ANCHOR IS USP TAPL 16, THE SPECIFIED | | | FASTENERS DO NOT CORRELATE WITH THE USP | | | CATALOGUE AND HAVE INSUFFICIENT CAPACITY | | | FOR THE UPLIFT AT THE LOCATION CALLED UP | | | ON THE PLAN (DERIVED FROM | | | FBC TABLE 1606.2A, ASSUMING 10 PSF DL | | | FOR WIND ANALYSIS). ALSO, AMEND THE ROOF | | | PLAN TO STATE THE CALCULATED UPLIFT FOR | | | EACH TRUSS.DELETE OR CORRECT THE | | | REFERENCE TO DADE COUNTY APPROVAL NO. | | | 92-0604.03 | | | B) "USP TRUSS ANCHOR".TAPL 16 & TA 16 | | | DATA IN THE 2003 USP CATALOGUE DOES NOT | | | CORRELATE WITH THE 1735 LB UPLIFT OR THE | | | FASTENERS STATED ON THE PLANS.AMEND | | | THE PLAN TO STATE ONE TYPE OF ANCHOR AND | | | STATE THE CORRECT FASTENERS AND UPLIFT | | | CAPACITY. | | | C) "USP ANCHOR DETAIL". THE PLAN REFERS | | | TO BOTH USP TAPL 16 AND (2) USP TA 16. | | | NEITHER ONE, WHEN CHECKED IN THE USP | | | CATALOGUE, CORRELATES WITH THE UPLIFT | | | (5386 LBS) AND THE FASTENERS STATED ON | | | THE PLANS.AMEND THE PLANS TO STATE THE | | | CORECT REFERENCES, FASTENERS & UPLIFT | | | CAPACITY.ALSO, THE DETAIL STILL REFERS | | | TO HUGHES SHA-8 STRAP.AMEND THE DETAIL | | | D) "USP ANCHOR DETAIL". THE PLAN REFERS | | | TO BOTH USP TAPL 16 AND USP TA 16.THE | | | SPECIFIED FASTENERS DO NOT CORRESPOND TO | | | THE FASTENERS IN THE USP CATALOGUE. | | | AMEND THE PLAN. | | | E) "USP USC GIRDER TRUSS ANCHOR". | | | AMEND THE PLAN TO SHOW WHICH USC ANCHOR | | | IS TO BE USED AND TO SHOW THE | | | APPROPRIATE FASTENERS. | | | | | | 12) FBC 11-4.8.2ANNOTATE EACH OF THE | | | NEW RAMPS ON THE PLANS TO VERIFY THAT | | | THE SLOPE WILL NOT EXCEED 1 IN 12. | | | | | | 26) FBC 13-103.0THE SUBMITTED ENERGY | | | CODE COMPLIANCE FORM SHALL HAVE THE | | | PROJECT ZIP, OWNER'S NAME AND PERMIT | | | NUMBER (02101739) ADDED SHEET 1.ALSO, | | | SHEET 2 MUST BE DATED BY THE PREPARER, | | | SIGNED AND DATED BY THE BUILDING OWNER/ | | | OWNER'S AGENT, AND CERTIFIED FOR CODE | | | COMPLIANCE BY THE DESIGN PROFESSIONALS | | | RESPONSIBLE FOR THE ARCHITECTURAL, | | | MECHANICAL, PLUMBING, ELECTRICAL AND | | | LIGHTING SYSTEMS. | | | | | | 32) THIS COMMENT HAS NOT BEEN ADDRESSED | | | FBC 1606.1.7THE PLANS DO NOT STATE THE | | | DESIGN WIND PRESSURE ON THE ROOF FOR | | | SELECTION OF AN APPROPRIATE ROOF SYSTEM. | | | ANNOTATE THE PLANS. | | | | | | 34)713.13(2) FL. STATUTES.THE | | | DESCRIBED WORKS DID NOT COMMENCE WITHIN | | | 90 DAYS OF RECORDING THE NOTICE OF | | | COMMENCEMENT SO THE NOTICE IS VOID AND | | | OF NO FURTHER EFFECT.IT SHALL BE RE- | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED. | | | | | | 35) THE PLANS SHALL BE RE-ROUTED TO | | | HISTORIC PRESERVATION DIVISION BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 36) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2003-08-12 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-08-12 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-08-12 |
Time |
17:58 |
Sent To |
|
|
| Notes |
| 2003-08-12 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 5/2/03: | | | | | | 2) IMPACT FEES. THE PLANS SHALL BE TAKEN | | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | | STAMPED AT THAT OFFICE AND A COPY OF THE | | | PAID RECEIPT SUBMITTED TO THE CITY OF | | | WEST PALM BEACH DEPT OF CONSTRUCTION | | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | | | 3) 61G15-23.002(2)FL. ADMIN. CODE | | | THE ENGINEERS LICENSE NUMBER SHALL BE | | | PRINTED ON EACH SHEET. | | | | | | 7) FBC 3401.7.1ADDITIONS TO EXISTING | | | BUILDINGS.AS THE AREA OF THE ADDITION | | | EXCEEDS 25% OF THE AREA OF THE EXISTING | | | BUILDING, THE EXISTING BUILDING AND THE | | | ADDITION SHALL BE MADE TO COMPLY WITH | | | ALL, EXCEPT STRUCTURAL, REQUIREMENTS OF | | | THE CODE FOR A BUILDING OF AREA EQUAL TO | | | THE COMBINED AREA.THIS REQUIREMENT | | | GIVES RISE TO COMMENTS 26 TO 31 BELOW. | | | | | | 10) SHEET R1, TRUSS CONNECTORS/ANCHORS. | | | THE STATED ANCHORS 'HCLH/HCRH', SHA-6' | | | AND 'HD 2X' ARE ALL HUGHES REFERENCES. | | | HUGHES ARE NO LONGER SUPPLIERS OF | | | ANCHORS.SPECIFY ALTERNATIVE ANCHORS. | | | ALSO, THE SPECIFIED UPLIFT AND FASTENERS | | | FOR THE 'HETA20' TRUSS ANCHOR DO NOT | | | CORRELATE TO THE UPLIFT AND FASTENERS IN | | | THE 2003 SIMPSON CATALOGUE.AMEND SHEET | | | R1.FINALLY, THE ROOF PLAN SHALL BE | | | AMENDED TO SHOW WHAT TYPE OF ANCHOR IS | | | TO BE USED IN EACH LOCATION. | | | | | | 12) FBC 11-4.1.2(1)EXTERIOR RAMPS TO | | | THE NEW HALL AND THE NEW PATIO HALL. | | | THIS COMMENT HAS NOT BEEN ADDRESSED. | | | AMEND THE PLANS TO SHOW THE SURFACE | | | MATERIAL (PAVERS, CONCRETE, ASPHALT, | | | GRASS, GRAVEL?) LEADING TO THE BASE OF | | | THE RAMPS AND TO SHOW CLEAR, LEVEL | | | ACCESS TO THE RAMPS FROM THE ACCESSIBLE | | | PARKING AND SIDEWALK. | | | | | | 14) PRODUCT APPROVAL DOCUMENTS: | | | -DRAWING SHEET #2 OF THE STEEL STORM | | | PANEL SHUTTER PRODUCT APPROVAL IS | | | MISSING.ALSO, DRAWING SHEET #1 IS A | | | POOR COPY AND IS NOT LEGIBLE.SUBMIT | | | LEGIBLE COPPIES OF DRAWING SHEETS 1 & 2 | | | SEE NOTE** BELOW. | | | -THE ALUMINUM SINGLE HUNG WINDOW | | | PRODUCT APPROVAL NOA# 02-0612.04 IS FOR | | | A SINGLE UNIT APPLICATION ONLY.SUBMIT | | | A PRODUCT APPROVAL FOR AN APPROPRIATE | | | STRUCTURAL MULLION FOR WINDOW TYPE B | | | (KITCHEN WINDOW).SEE NOTE** BELOW. | | | -THE 'GLADIATOR' O/S GLAZED STEEL | | | DOOR PRODUCT APPROVAL NOA# 99-1007.01 IS | | | MISSING SHEET 6 OF 7.SEE NOTE** BELOW. | | | -THE MODIFIED BITUMEN ROOF SYSTEM | | | PRODUCT APPROVAL NOA# 00-0331.08 SHALL | | | BE MARKED TO SHOW WHICH SYSTEM TYPE IS | | | TO BE USED. | | | **COPIES OF MIAMI-DADE PRODUCT APPROVALS | | | CAN BE PRINTED FROM THEIR WEBSITE, | | | WWW.MIAMIDADE.GOV/BUILDINGCODE/PC-SEARCH | | | _APP.ASP | | | | | | 26) FBC 13-103.1.1.1SUBMIT AN ENERGY | | | CODE COMPLIANCE FORM FOR THE WHOLE | | | BUILDING (SEE COMMENT 7 ABOVE).THE | | | FORM MUST BE SIGNED BY THE PREPARER, | | | BUILDING OWNER AND THE DESIGN | | | PROFESSIONALS RESPONSIBLE FOR THE | | | ARCHITECTURAL, MECHANICAL, PLUMBING, | | | ELECTRICAL AND LIGHTING SYSTEMS. | | | | | | 27) FBC 1007.3ANNOTATE THE PLANS TO | | | SHOW THAT THE EXISTING STAIR TREADS ARE | | | MIN. 11" AND RISERS ARE MAX. 7". | | | | | | 28) FBC 1007.4THE STAIR SHALL HAVE A | | | FULL LANDING BETWEEN THE TOP RISER AND | | | THE DOOR.THE DOOR AND ASSOCIATED WALL | | | SHALL BE REPOSITIONED.AMEND THE PLANS | | | TO SHOW THE PROPOSAL FOR COMPLIANCE. | | | | | | 29) 1007.5THE EXISTING STAIR HANDRAIL | | | SHALL BE MADE TO COMPLY WITH ALL OF THE | | | REQUIREMENTS OF FBC 1007.5, INCLUDING: | | | -HANDRAIL HEIGHT SHALL BE BETWEEN | | | 34" (36" TO ALSO COMPLY WITH FBC 1026.5) | | | AND 38" ABOVE THE LEADING EDGE OF THE | | | TREAD. | | | -HANDRAILS ARE REQUIRED ON BOTH | | | SIDES OF THE STAIR. | | | -HANDRAIL CROSS-SECTIONAL SHAPE AND | | | SIZE SHALL COMPLY. | | | -THE HANDRAILS SHALL EXTEND AT LEAST | | | 12" HORIZONTALLY BEYOND THE TOP RISER OF | | | THE FLIGHT AND SHALL CONTINUE TO SLOPE | | | PAST THE BOTTOM RISER FOR A DISTANCE | | | EQUAL TO ONE TREAD. | | | -THE HANDRAIL/GUARDING AND | | | ATTACHMENTS SHALL MEET THE STRENGTH | | | REQUIREMENTS OF FBC 1608.2.1.1 TO | | | FBC 1608.2.2.4 | | | | | | 30) FBC 1015.3THE EXISTING STAIR | | | GUARDING SHALL REJECT THE PASSAGE OF A | | | 4" SPHERE.ANNOTATE THE PLANS TO | | | DEMONSTRATE COMPLIANCE. | | | | | | 31) FBC 2405.2 THE GLAZING IN THE SHOWER | | | ENCLOSURES AND WINDOWS IN BATH# 4 & 6 | | | (IF THE BOTTOM EDGE OF THE GLASS IS NOT | | | GREATER THAN 60" ABOVE THE STANDING | | | SURFACE) IS IN A HAZARDOUS LOCATION AND | | | REQUIRED TO BE SAFETY GLASS SATISFYING | | | THE REQUIREMENTS OF THE CONSUMER PRODUCT | | | SAFETY COMMISSION 16, CODE OF FEDERAL | | | REGULATIONS, PART 1201 (CPSC 16-CFR, | | | PART 1201).AMEND THE PLANS TO | | | DEMONSTRATE COMPLIANCE. | | | | | | 32) FBC 1606.1.7THE PLANS DO NOT STATE | | | THE DESIGN WIND PRESSURE ON THE ROOF FOR | | | SELECTION OF AN APPROPRIATE ROOF SYSTEM. | | | ANNOTATE THE PLANS. | | | | | | 33) FBC 3502 THE NOTES ADDED TO SHEET A3 | | | SHALL BE AMENDED AS FOLLOWS: | | | -MASONRY WALL NOTE D REFERS TO | | | ASTM C 90-75 FOR CONCRETE BLOCKS.THE | | | STANDARD REFERENCED IN THE CODE IS | | | ASTM C 90-90 | | | -DESIGN DATA NOTE A REFERS TO | | | ACI 318-77 FOR STRUCTURAL CONCRETE.THE | | | STANDARD REFERENCED IN THE CODE IS | | | ACI 318-99 | | | -DESIGN DATA NOTE F REFERS TO | | | ASTM A 185-73 FOR WELDED WIRE FABRIC. | | | THE STANDARD REFERENCED IN THE CODE IS | | | ASTM A 185-92 | | | -PRE-ENGINEERED WOOD TRUSSES NOTE B | | | REFERS TO PALM BEACH COUNTY. THIS SHOULD | | | BE CITY OF WEST PALM BEACH. | | | -WOOD FRAMING NOTE D REFERS TO | | | STANDARD BUILDING CODE.THIS SHOULD BE | | | FLORIDA BUILDING CODE | | | | | | 34) 713.13(2) FL. STATUTES.THE | | | DESCRIBED WORKS DID NOT COMMENCE WITHIN | | | 90 DAYS OF RECORDING THE NOTICE OF | | | COMMENCEMENT SO THE NOTICE IS VOID AND | | | OF NO FURTHER EFFECT.IT SHALL BE RE- | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED. | | | | | | 35)HISTORIC PRESERVATION DIVISION | | | STAMPED THE PLANS AS 'APPROVED' ON | | | 10/28/02.THE PLANS HAVE BEEN THROUGH | | | A NUMBER OF REVISIONS SINCE THEN.WHEN | | | THE REVISED PLANS HAVE BEEN PASSED BY | | | THE CONSTRUCTION SERVICES DEPARTMENT | | | THEY SHOULD BE TAKEN, TOGETHER WITH THE | | | STAMPED 'OLD' PLANS, FOR REVIEW AND | | | RE-STAMPING BY HISTORIC PRESERVATION | | | DIVISION. | | | | | | 36) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-05-02 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-05-02 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2003-05-02 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 2/19/03: | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) 61G15-23.002(2)FL. ADMIN. CODE. | | | THIS COMMENT HAS NOT BEEN PROPERLY | | | ADDRESSED.THE ENGINEER'S NAME AND | | | ADDRESS HAVE BEEN 'TAPED' ON THE PLAN | | | SHEETS.THIS IS NOT APPROPRIATE FOR | | | PERMITTING AND RECORD RETENTION PURPOSES | | | (FBC* 104.2.1.3).PRINT THE DETAILS ON | | | THE PLANS.PLANS SIGNED AND SEALED BY A | | | PROFESSIONAL ENGINEER SHALL INCLUDE THE | | | NAME AND ADDRESS OF THE ENGINEER AS WELL | | | AS THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER FOR THE ENGINEERING | | | BUSINESS, IF APPROPRIATE. | | | | | | 4) FBC 434.2ASSISTED LIVING FACILITY. | | | THE PLANS NOW CONFIRM THE APPROPRIATE | | | OCCUPANCY AND THE BUILDING COMES UNDER | | | THE ABOVE SPECIAL OCCUPANCY DEFINITION. | | | SEE COMMENTS 22, 23 AND 24, BELOW FOR | | | ADDITIONAL REQUIREMENTS FOR THIS USAGE. | | | | | | 7) FBC 3401.7.1ADDITIONS TO EXISTING | | | BUILDINGS.THIS COMMENT HAS NOT BEEN | | | ADDRESSED.FROM THE EXISTING AND NEW | | | FLOOR AREAS GIVEN ON SHEET A2, THE AREA | | | OF THE ADDITION EXCEEDS 25% OF THE AREA | | | OF THE EXISTING BUILDING.IF THE | | | EXISTING BUILDING AND THE ADDITION ARE | | | NOT SEPARATED BY A 4-HOUR FIRE WALL, | | | BOTH THE EXISTING BUILDING AND THE | | | ADDITION SHALL BE MADE TO COMPLY WITH | | | ALL THE REQUIREMENTS OF THE CODE FOR A | | | BUILDING OF AREA EQUAL TO THE COMBINED | | | AREA OF THE ADDITION AND THE EXISTING | | | BUILDING.SUBMIT FURTHER PLANS, | | | INCLUDING THE EXISTING BUILDING, TO | | | DEMONSTRATE COMPLIANCE. | | | | | | 9) SHEET A3, GENERAL STRUCTURAL NOTES. | | | THIS COMMENT HAS NOT BEEN PROPERLY | | | ADDRESSED.CORRECT NOTE 1 TO READ | | | "....AS AMENDED BY THE CITY OF WEST PALM | | | BEACH" | | | | | | 10) SHEET A3, TRUSS CONNECTOR/ANCHOR | | | SCHEDULE AND NOTES.ANCHOR A-3 IS | | | SPECIFIED WITH 7-16D NAILS AND A MAXIMUM | | | UPLIFT OF 1060 LBS.THIS DOES NOT | | | REFLECT THE USP CATALOGUE REQUIREMEMENT | | | FOR 13-10D NAILS TO THE TRUSS PLUS | | | 6-10D X 1-1/2 NAILS TO THE SEAT PLATE. | | | ALSO, ANCHOR B-5 IS SPECIFIED AS RTF OR | | | RTP (NOT LEGIBLE). THIS IS AN INCOMPLETE | | | OR INCORRECT USP REFERENCE.RE-SPECIFY | | | AS NECESSARY AND PROVIDE A LEGIBLE | | | SCHEDULE. | | | | | | 12) FBC 11-4.1.2(1)EXTERIOR RAMPS TO | | | THE NEW HALL AND THE NEW PATIO HALL. | | | THIS COMMENT HAS NOT BEEN ADDRESSED. | | | AMEND THE PLANS TO SHOW THE SURFACE | | | MATERIAL (PAVERS, CONCRETE, ASPHALT, | | | GRASS, GRAVEL?) LEADING TO THE BASE OF | | | THE RAMPS AND TO SHOW CLEAR, LEVEL | | | ACCESS TO THE RAMPS FROM THE ACCESSIBLE | | | PARKING AND SIDEWALK. | | | | | | 14) PRODUCT APPROVAL DOCUMENTS.THIS | | | COMMENT HAS NOT BEEN PROPERLY ADDRESSED. | | | PRODUCT APPROVALS HAVE BEEN SUBMITTED AS | | | LOOSE SHEETS IN NON-NUMERICAL ORDER. | | | ALSO, THE DOOR PRODUCT APPROVAL IS | | | EXPIRED.PROVIDE TWO COPIES OF VALID | | | (NON-EXPIRED) PRODUCT APPROVALS.THE | | | SHEETS IN EACH PRODUCT APPROVAL SHALL | | | BE COLLATED AND STAPLED, AND THE | | | RELEVANT PRODUCTS/COMPONENTS SHALL BE | | | CIRCLED OR OTHERWISE HIGHLIGHTED. | | | | | | THE FOLLOWING ARE NEW COMMENTS ARISING | | | FROM REVIEW OF THE REVISED PLANS: | | | | | | 22) FBC 434.4.3.1A MINIMUM OF 35 SQFT | | | OF LIVING AND DINING SPACE SHALL BE | | | PROVIDED FOR EACH RESIDENT, LIVE-IN | | | STAFF MEMBER AND LIVE-IN FAMILY MEMBER. | | | AMEND THE PLANS TO CLEARLY SHOW HOW THIS | | | REQUIREMENT IS TO BE MET. | | | | | | 23) FBC 434.4.3.2A ROOM, SEPARATE FROM | | | RESIDENT'S BEDROOMS, SHALL BE PROVIDED | | | FOR LEISURE TIME ACTIVITIES.AMEND THE | | | PLANS TO CLEARLY SHOW HOW THIS | | | REQUIREMENT IS TO BE MET. | | | | | | 24) FBC 434.4.3.3THE DINING AREA SHALL | | | BE FURNISHED TO ACCOMMODATE COMMUNAL | | | DINING.AMEND THE PLANS TO CLEARLY | | | SHOW HOW THIS REQUIREMENT IS TO BE MET. | | | | | | 25) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-02-19 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-04-29 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-02-19 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2003-02-19 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | ***NOTE:*** | | | A NUMBER OF THE COMMENTS FROM THE | | | PREVIOUS REVIEW HAVE NOT BEEN ADDRESSED. | | | CHAPTER 553.80(2)(B) FLORIDA STATUTES | | | STATES THAT A LOCAL GOVERNMENT SHALL | | | IMPOSE A FEE OF FOUR TIMES THE FEE FOR | | | PLAN REVIEW, IF PLANS ARE REJECTED THREE | | | OR MORE TIMES FOR REPEATED FAILURE TO | | | CORRECT A CODE VIOLATION. | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 12/4/02: | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) 61G15-23.002(2)FL. ADMIN. CODE. | | | THIS COMMENT HAS NOT BEEN ADDRESSED. | | | PLANS SIGNED AND SEALED BY A | | | PROFESSIONAL ENGINEER SHALL INCLUDE THE | | | NAME AND ADDRESS OF THE ENGINEER AS WELL | | | AS THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER FOR THE ENGINEERING | | | BUSINESS, IF APPROPRIATE. | | | | | | 4) FBC 311.2THE STATED R2 OCCUPANCY | | | IS INCORRECT.PLANNING AND ZONING HAVE | | | ADVISED THAT THEIR APPROVAL WAS BASED | | | ON GROUP HOME OCCUPANCY WHICH WOULD BE | | | R4 RESIDENTIAL.ALSO, THE CURRENT | | | OCCUPATIONAL LICENSE (SUMMARY SHEET | | | ATTACHED) IS FOR ADULT CONGREGATE LIVING | | | FACILITY (ACLF) WHICH IS A GROUP HOME | | | AND SO R4 RESIDENTIAL OCCUPANCY.AMEND | | | THE PLANS ACCORDINGLY. | | | | | | 6) FBC 11-4.1.5ACCESSIBLE TOILETS AND | | | BEDROOMS.THE EXTENT OF REQUIRED | | | PROVISIONS WILL BE DEPENDENT UPON THE | | | RESPONSE TO COMMENT 4 ABOVE. | | | | | | 7) FBC 3401.7.1ADDITIONS TO EXISTING | | | BUILDINGS.FROM THE EXISTING AND NEW | | | FLOOR AREAS NOW GIVEN ON SHEET A2, THE | | | AREA OF THE ADDITION EXCEEDS 25% OF THE | | | AREA OF THE EXISTING BUILDING.IF THE | | | EXISTING BUILDING AND THE ADDITION ARE | | | NOT SEPARATED BY A 4-HOUR FIRE WALL BOTH | | | THE EXISTING BUILDING AND THE ADDITION | | | SHALL BE MADE TO COMPLY WITH ALL | | | REQUIREMENTS OF THE CODE FOR A BUILDING | | | OF AREA EQUAL TO THE COMBINED AREA OF | | | THE ADDITION AND THE EXISTING BUILDING. | | | SUBMIT FURTHER PLANS, INCLUDING THE | | | EXISTING BUILDING, TO DEMONSTRATE | | | COMPLIANCE. | | | | | | 8) SHEET A3, GENERAL NOTES. THIS COMMENT | | | HAS NOT BEEN PROPERLY ADDRESSED.ON THE | | | PREVIOUSLY SUBMITTED PLAN SET, THE FIRST | | | LINE OF THE FIRST NOTE HAD BEEN | | | CORRECTED, BY HAND, TO READ FLORIDA | | | BUILDING CODE INSTEAD OF STANDARD | | | BUILDING CODE.THIS CORRECTION HAS NOT | | | BEEN CARRIED OUT ON THE REVISED PLANS. | | | THE SIXTH NOTE STILL REFERS TO STANDARD | | | BUILDING CODE. AMEND ALL SUCH REFERENCES | | | TO FLORIDA BUILDING CODE 2001. | | | | | | 9) SHEET A3, GENERAL STRUCTURAL NOTES. | | | THIS COMMENT HAS NOT BEEN ADDRESSED. | | | AMEND NOTE 1 TO REFERENCE FLORIDA | | | BUILDING CODE AND THE CITY OF WEST PALM | | | BEACH INSTEAD OF STANDARD BUILDING CODE | | | AND PALM BEACH COUNTY. | | | | | | 10) SHEET A3, TRUSS CONNECTOR/ANCHOR | | | SCHEDULE AND NOTES. THIS COMMENT HAS NOT | | | BEEN PROPERLY ADDRESSED. THE SCHEDULE IS | | | NOW LEGIBLE BUT REFERS TO 'SEMCO' WHO NO | | | LONGER SUPPLY TRUSS CONNECTORS/ANCHORS. | | | SPECIFY CURRENT ANCHORS.THE SCHEDULE | | | NOTES STILL REFER TO ASCE 7-88 AND A | | | BASIC WIND SPEED OF 110 MPH.AMEND THIS | | | TO ASCE 7-98 AND 140 MPH.REVIEW THE | | | SUBMITTED PLAN SETS AND AMEND ALL OTHER | | | REFERENCES THAT INCORRECTLY CALL UP | | | SOUTHERN BUILDING CODE, STANDARD | | | BUILDING CODE, 110 MPH WIND SPEED AND | | | ASCE 7-88, INCLUDING THE OCCURANCE IN | | | THE LOAD SCHEDULE ON SHEET A3 WHICH | | | STILL HAS NOT BEEN CORRECTED.THE ONLY | | | CORRECTION THAT HAS BEEN MADE IS THE | | | BASIC WIND SPEED ON THE LOAD SCHEDULE. | | | | | | 12) FBC 11-4.1.2(1)EXTERIOR RAMPS TO | | | THE NEW HALL AND THE NEW PATIO HALL. | | | THE PLANS HAVE BEEN REVISED TO EXTEND | | | THESE RAMPS TO ACHIEVE COMPLIANT | | | GRADIENTS.AS A RESULT OF THE EXTENSION | | | THE SIDEWALKS LEADING TO THE BASE OF THE | | | RAMPS WILL REQUIRE ADJUSTMENT TO ALLOW | | | UNRESTRICTED WHEELCHAIR ACCESS TO EACH | | | RAMP. | | | | | | 14) SHUTTER PRODUCT APPROVAL DOCUMENTS. | | | THE DRAWING SUBMITTED WITH EASTERN METAL | | | SUPPLY INC. SBCCI TESTING & EVALUATION | | | REPORT NO. 2211 ARE NOT THE SAME SHEETS | | | REFERENCED IN 6.1 SUBSTANTIATING DATA ON | | | PAGE 7 OF 8. SUBMIT DRAWING SHEETS WHICH | | | CORRESPOND TO THE TEST REPORT. | | | | | | THE FOLLOWING ARE NEW COMMENTS ARISING | | | FROM REVIEW OF THE REVISED PLANS: | | | | | | 17) FBC* 104.2.1.3TWO VERSIONS OF | | | SHEET A1 WERE SUBMITTED WITH DIFFERENT | | | INFORMATION ON EACH.RE-NUMBER THE | | | MOST RECENT (WITH THE LANDSCAPING) TO | | | DIFFERENTIATE IT FROM THE VERSION | | | PREVIOUSLY SUBMITTED. | | | | | | 18) FBC* 104.2.1.3 SHEET A2 AND SHEET A7 | | | (DOOR SCHEDULE) HAVE PENCIL NOTES ADDED. | | | THE USE OF PENCIL IS NOT APPROPRIATE ON | | | PLANS FOR PERMITTING PURPOSES.AMEND | | | THE PLANS IN INK. | | | | | | 19) SHEET D1, CONCRETE BEAM SCHEDULE. | | | THE PREVIOUSLY SUBMITTED PLAN SET | | | INCLUDED HANDWRITTEN NOTES FOR BEAM TYPE | | | RB-3. THESE NOTES HAVE BEEN OMITTED FROM | | | THE REVISED PLAN SET. | | | | | | 20) SHEET S1, FOUNDATION PLAN.THE | | | PREVIOUSLY SUBMITTED PLAN SET INCLUDED | | | HANDWRITTEN NOTES SPECIFYING VERTICAL | | | REBAR DOWELS ON EACH SIDE OF THE DOOR | | | AND WINDOW OPENINGS.THESE NOTES HAVE | | | BEEN OMITTED FROM THE REVISED PLAN SET. | | | | | | 21) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-12-05 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2002-12-04 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2002-12-04 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2002-12-04 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) 61G15-23.002(2) FL. ADMIN. CODE. | | | PLANS SIGNED AND SEALED BY A | | | PROFESSIONAL ENGINEER SHALL INCLUDE THE | | | NAME AND ADDRESS OF THE ENGINEER AS WELL | | | AS THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER FOR THE ENGINEERING | | | BUSINESS, IF APPROPRIATE. | | | | | | 4) FBC 309, 420, 434.IS THE OCCUPANCY | | | GROUP I (UNRESTRAINED) INSTITUTIONAL, | | | R4 ASSISTED LIVING FACILITY OR NURSING | | | HOME?THE PLANS AND/OR APPLICATION FORM | | | SHALL STATE WHICH OCCUPANCY CATEGORY THE | | | FACILITY WILL BE USED FOR.UNTIL THIS | | | INFORMATION IS PROVIDED, A FULL PLAN | | | REVIEW CANNOT BE COMPLETED. | | | | | | 5) FBC* 104.2.1.3SHEETS A1, A2, A3 AND | | | A6 HAVE TEXT WHICH CANNOT BE READ DUE TO | | | POOR CONTRAST/COPY QUALITY.SUBMIT | | | LEGIBLE COPIES.A FULL PLAN REVIEW HAS | | | NOT BEEN COMPLETED. | | | | | | 6) FBC 11-4.1.5ACCESSIBLE TOILETS AND | | | BEDROOMS.THE EXTENT OF REQUIRED | | | PROVISIONS WILL BE DEPENDENT UPON THE | | | RESPONSE TO COMMENT 4 ABOVE. | | | | | | 7) FBC 104.2.1.2THE PLANS SHALL STATE | | | THE FLOOR AREA AND, IF DIFFERENT, THE | | | 'AREA UNDER ROOF' FOR THE EXISTING AND | | | THE NEW CONSTRUCTION. | | | | | | 8) SHEET A3, GENERAL NOTES.THE FIRST | | | NOTE REFERS TO THE CODE "..AS AMENDED BY | | | PALM BEACH COUNTY".THIS SHOULD READ | | | "..AS AMENDED BY THE CITY OF WEST PALM | | | BEACH".THE FIFTH NOTE REFERS TO THE | | | STANDARD BUILDING CODE AND PALM BEACH | | | COUNTY AGAIN.ALL SUCH REFERENCES SHALL | | | BE AMENDED. | | | | | | 9) SHEET A3, GENERAL STRUCTURAL NOTES. | | | NOTE 1 SHALL BE AMENDED TO REFERENCE | | | FLORIDA BUILDING CODE AND THE CITY OF | | | WEST PALM BEACH INSTEAD OF STANDARD | | | BUILDING CODE AND PALM BEACH COUNTY. | | | | | | 10) SHEET A3, TRUSS CONNECTOR/ANCHOR | | | SCHEDULE NOTES.THE NOTES ARE NOT FULLY | | | LEGIBLE BUT APPEAR TO MAKE REFERENCE TO | | | ASCE 7-88 AND A WIND SPEED OF 110 MPH. | | | THIS SHALL BE AMENDED TO ASCE 7-98 AND | | | 140 MPH.AMEND ALL OTHER REFERENCES TO | | | SOUTHERN BUILDING CODE, STANDARD | | | BUILDING CODE, 110 MPH WIND SPEED AND | | | ASCE 7-88, INCLUDING THE TWO OCCURANCES | | | IN THE LOAD SCHEDULE ON SHEET A3. | | | | | | 11) FBC 2405.2THE FOLLOWING GLAZING IS | | | IN A 'HAZARDOUS LOCATION' AND IS | | | REQUIRED TO BE SAFETY GLASS SATISFYING | | | THE REQUIREMENTS OF THE CONSUMER PRODUCT | | | SAFETY COMMISSION 16, CODE OF FEDERAL | | | REGULATIONS, PART 1201 (CPSC 16-CFR, | | | PART 1201): | | | - SHOWER WINDOWS (SCHEDULE MARK C) | | | - ANY GLAZING IN THE SHOWER DOORS | | | SUBMIT DETAILS TO DEMONSTRATE COMPLIANCE | | | | | | 12) FBC 1013.3 & FBC 11-4.8.2EXTERIOR | | | RAMPS TO THE NEW HALL AND THE NEW PATIO | | | HALL.SHEETS A2 AND S1 SHOW FIVE RISERS | | | WHICH IMPLIES A LEVEL CHANGE OF 34.75". | | | THE PROPOSED RAMP WOULD HAVE A SLOPE | | | GREATER THAN 1 IN 12.AMEND THE RAMP TO | | | COMPLY. | | | | | | 13) FBC 104.2.1.2EXTERIOR STAIR AT | | | NORTH ELEVATION.IS THIS STAIR NEW | | | CONSTRUCTION?SHEET A6 SHOWS IT AS PART | | | OF THE EXISTING BUILDING, AND IT IS NOT | | | SHOWN ON SHEET A1 AS PART OF THE NEW | | | CONSTRUCTION.IS THERE A RAMP | | | ASSOCIATED WITH THIS STAIR, NO DETAILS | | | HAVE BEEN PROVIDED?AMEND THE PLANS TO | | | CLARIFY THE PROPOSALS FOR THIS AREA. | | | | | | 14) THE SUBMITTED SHUTTER PRODUCT | | | APPROVAL NOA# 99-0318.03 EXPIRED PRIOR | | | TO THE DATE OF PERMIT APPLICATION. | | | SUBMIT AN NEW PRODUCT APPROVAL. | | | | | | 15) NORTH ELEVATION WINDOW (SCHEDULE | | | MARK B).THE SUBMITTED SINGLE HUNG | | | WINDOW PRODUCT APPROVAL NOA# 01-0226.04 | | | IS APPLICABLE TO SINGLE UNIT | | | APPLICATIONS ONLY (SEE LIMITATIONS ON | | | SPECIFIC CONDITIONS SHEET).SUBMIT A | | | NEW WINDOW PRODUCT APPROVAL OR AN | | | APPROPRIATE MULLION PRODUCT APPROVAL. | | | | | | 16) IF NEW PLAN SHEETS ARE REQUIRED, IN | | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHALL BE INCLUDED WITH THE | | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2005-09-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-09-26 |
Time |
15:41 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-09-26 |
Time |
15:41 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2003-10-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-20 |
Time |
10:37 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-10-20 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2003-09-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-09-22 |
Time |
19:38 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-09-22 |
Time |
19:38 |
Sent To |
|
|
| Notes |
| 2003-09-24 00:00:00 | A 4X FEE THAT WAS ADDED HAS BEEN DELETE | | | -ED BY KIM MCVEY PER MIKE SIZEMORE. | | | UNDER CITY CODE AND FS THIS SHALL NOT | | | BE DONE. FEES ARE DUE AND MUST BE PAID. | | | ELECTRICAL SHALL REMAIN INJ -F- STATUS | | | UNITL THAT TIME. 553.80(2)(B), | | | CITY ADMINISTRATIVE CODE 104.6.2 | | 2003-09-22 00:00:00 | ** REDLINED OCP FOR DRYER TO BE 30A FOR | | | 5KW.** |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2003-08-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-08-19 |
Time |
15:32 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2003-08-19 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2003-08-19 00:00:00 | ************ UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE NOTES FROM LAST | | | REVIEW PERTAINING TO PANEL SCHEDULE AND | | | CORRELATION OF LOADS/AWG'S AND OCP. | | | PLEASE SEE GEN LT ETC 20OCP ON #14, | | | DRYER SHOWN AS 120V | | | PLEASE SEE OVEN MICR AT 12KW W/ 40A OCP | | | | | | 2)NOTE: PLEASE SEE PREVIOUS NOTES | | | THAT LIST BATHS TO BE DEDICATED AS | | | 20A AND #12 AWG. 210-11C-3/ 210-52D | | | | | | 3)NOTE: PLEASE SEE MISSING INFORMATION | | | REQ'D ON TITLE BLOCK FOR ENGINEER OF | | | RECORD UNDER FAC/FS 61G15-23.002/ 471 | | | | | | PLEASE SEE LETTER ATTACHED ONCE AGAIN | | | FOR FS 553.80(2)(B) WITH RESPECT TO | | | DESIGN PROFESSIONAL. PLEASE NOTE, A | | | 4X FEE FOR PLAN WILL BE ACCESSED FOR THE | | | PLAN REVIEW PORTION IF COMMENTS ARE NOT | | | ADDRESSED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | PLEASE SEE GROUNDING ELECTRODE CONDUCTOR | | | IT WAS GIVEN IN NOTES AT LAST MEETING | | | THIS NEEDS TO BE SIZED PER 250-66 | | | THIS HAS NOT BEEN CHANGED TO DATE, STILL | | | SHOWS #4 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-04-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-11 |
Time |
02:25 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-04-11 |
Time |
02:25 |
Sent To |
|
|
| Notes |
| 2003-04-11 00:00:00 | *********** UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE RISER DIAGRAM, | | | SHOWS #1`S AND #3 FOR 200A DISC AND | | | PANEL? PLEASE SIZE PER 310-16 | | | | | | 2)NOTE: PLEASE SEE CIRCUITS ON PANEL | | | SCHEDULE/LOAD CALCS. SMALL APPL AND | | | GEN LT SHOWN AT 240V? PLEASE ALSO SEE | | | CIRCUITS #`S SHOWN FOR SM APPL ,, SHOWS | | | TWO CIRCUITS AND SHOWS LOAD FOR THREE | | | CIRCUITS?PLEASE CLARIFY | | | | | | 3)NOTE: PLEASE SEE PLANS,ALMOST ALL | | | RECEPTS AND LTS ARE SHOWN ON TWO CIRCUIT | | | -S 21&28. PLEASE SEE 210-52D/210-11C3 | | | BATHS MAY NOT BE ON WITH OTHER CIRCUITS, | | | PLEASE ALSO CLARIFY, SOME CIRCUITS ARE | | | SHOWN GOING OVER TO EXISTING BLDG CROSS- | | | ING OVER TO AREA WITH SEPARATE SERVICE? | | | 210-25 PLEASE ADJUST CIRCUITS. | | | | | | 4)NOTE: PLEASE SEE 250-122 FOR SIZING | | | OF EQUIPMENT GROUNDING CONDUCTOR FROM | | | NEW MAIN TO PANEL. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-02-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-24 |
Time |
05:52 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-02-24 |
Time |
05:52 |
Sent To |
|
|
| Notes |
| 2003-02-24 00:00:00 | ************** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE NOTES FROM FIRST | | | REVIEW. NONE WERE ADDRESSED. | | | | | | 2)NOTE: PLEASE SEE ATTACHED LETTER PER | | | FS 553.80(2)(B) FOR NEXT PLAN REVIEW. | | | | | | PLEASE SUBMIT COMPLETED PLANS FOR REVIEW | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-05 |
Time |
07:33 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2002-11-05 |
Time |
07:33 |
Sent To |
|
|
| Notes |
| 2002-11-05 00:00:00 | *************** UNSAT ************** | | | | | | 1)NOTE: PLEASE NOTE PLANS SIGNED AND | | | SEALED BY AN ENGINEER MUST CONTAIN | | | A TITLE BLOCK W/ INFORMATION SET FORTH | | | IN FAC. 61G15-23.002 | | | | | | 2)NOTE: PLEASE SHOE ALL CIRCITING ON | | | PLANS AND CORRELATE WITH PANEL SCHEDULE- | | | (S). | | | | | | 3)NOTE: PLEASE NOTE, SD`S REQ`D INSIDE | | | AND OUTSIDE ALL SLEEPING ROOMS AND A | | | MIN OF 3' AWAY FORM BATHROOMS. | | | NFPA-72 8-1.4.1.6 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE NAY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
P |
Date |
2003-11-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-11-06 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-11-06 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2003-11-06 00:00:00 | APPROVED PROVISO: | | | | | | 1) KITCHEN DOOR SHALL NOT SWING INTO | | | HALLWAY. DOOR SWING IS TO BE REVERSED | | | AND SHALL OPEN INWARD NOT OUTWARD AS | | | DISPLAYED IN SOME SHEETS. | | | | | | 2) STILL HAVE NOT RECEIVED PROPOSED | | | EVACUATION CAPABILITY FOR THE NEW | | | RESIDENTS. | | | | | | 3) SMOKE DETECTORS ARE REQUIRED IN | | | LIVING ROOMS, DENS, DAY ROOMS, ETC. | | | | | | 4) EVERY BATHROOM DOOR SHALL BE ABLE | | | TO BE UNLOCKED FROM THE OUTSIDE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
F |
Date |
2003-10-09 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-10-09 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-10-09 |
Time |
17:50 |
Sent To |
|
|
| Notes |
| 2003-10-14 00:00:00 | 1) DOOR FROM KITCHEN BLOCKS EXIT | | | HALLWAY BY MORE THAN 50 PERCENT. THIS | | | PROBLEM HAS BEEN PREVOUSLY DISCUSSED | | | WITH THE CONTRACTOR AND SHOULD HAVE | | | BEEN REVISED ON THE PLANS. | | | | | | 2) NO EVACUATION CAPABILITY OF THE | | | NEW PROPOSED RESIDENTS HAS BEEN | | | PROVIDED. THIS INFORMATION HAD BEEN | | | REQUESTED ON THE 4TH PLAN REVIEW. | | | | | | 3) COULD NOT LOCATE INFORMATION WITH | | | REGARDS TO SELF-CLOSING DEVICES. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2003-08-27 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-08-27 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-08-27 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2003-08-27 00:00:00 | 1) SEPARATE PLANS AND PERMITS | | | REQUIRED FIRE ALARM SYSTEM REMODEL. | | | | | | 2) SEPARATE PLANS AND PEMRITS REQUIRE | | | FOR FIRE SPRINKLER REMODEL. | | | | | | 3) ALL NEW SMOKE DETECTORS THAT ARE | | | INSTALLED SHALL BE POWERED BY THE | | | HOUSE ELECTRICAL SERVICE. THESE SMOKE | | | DETECTORS SHALL BE INSTALLED IN | | | ACCORDANCE WITH MANUFACTURER'S | | | REQUIREMENTS. | | | | | | 4) ALL NEW STAIRS AND RAMPS SHALL HAVE | | | HANDRAILS ON BOTH SIDES. ALL NEW | | | STAIRS SHALL BE AT LEAST 44" WIDE. | | | | | | 5) DOORS # 5 AND # 6 ARE NOT NOTED | | | ON THE DOOR SCHEDULE. ALSO NO | | | INFORMATION PROVIDED WITH REGARDS | | | TO SELF-COSING DEVICES INSTALLED | | | ON THE SLEEPING ROOM DOORS. | | | | | | 6) ARE ANY FIRE SPRINKLERS PLANNED TO | | | PROTECT THE WOOD TRUSSES. | | | | | | 7) NO INFORMATION PROVIDED FOR INTERIOR | | | FINISH CLASSIFICATION FOR WALLS AND | | | CEILINGS. | | | | | | 8) IN SOME AREAS OF THE PLANS 5/8" | | | DRYWALL IS NOTED. 5/8" TYPE X DRYWALL | | | IS REQUIRED. | | | | | | 9) DOESN'T THE KITCHEN DOOR BLOCK THE | | | EGRESS HALLWAY BY MORE THEN 50 %. | | | | | | 10) PLEASE INDICATE THE EVACUATION | | | CAPABILITY OF THE NEW PROPOSED | | | RESIDENTS. WILL THEY BE SLOW, PROMPT | | | OR IMPRACTICAL. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2003-04-29 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-04-29 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-04-29 |
Time |
14:54 |
Sent To |
B |
|
| Notes |
| 2003-04-29 00:00:00 | DENIED: | | | | | | NOTES AND COMMENTS FROM 1ST & 2ND PLAN | | | REVIEW HAVE NOT BEEN ADDRESSED. | | | (SEE ATTACHED) | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE FEEL | | | FREE TO CONTACT MIKE CARSILLO OR NATE | | | MCCRAY AT 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2003-03-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-03-05 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-03-05 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2003-03-05 00:00:00 | 1) DRAWINGS DO NOT PROVIDE THE REQUIRED | | | INFORMATION TO PERFORM A PROPER PLAN | | | REVIEW. | | | | | | 2) PLANS DO NOT INDICATE ALL EXISTING | | | FIRE AND LIFE SAFETY EQUIPMENT. | | | | | | 3) PLANS ARE DIFFICULT TO READ IN | | | SOME LOCALES. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-11-22 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-11-22 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-11-22 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2002-11-22 00:00:00 | 1) PLANS ARE DIFFICULT TO READ. | | | | | | 2) PLEASE CLEARLY IDENTIFY ALL LIFE | | | SAFETY DEVICES AND OR SYSTEMS. THE | | | ELECTRICAL LEGEND INDICATES A LEGEND | | | FOR SMOKE DETECTORS BUT NONE COULD | | | BE LOCATED. PLEASE SHOWN THESE ON | | | THE PLANS. | | | | | | 3) PLANS NEED TO CLEARLY IDENTIFY | | | THE NEW WORK THAT IS PLANNED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2003-10-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-16 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-17 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2003-10-16 00:00:00 | TO COMM BD#23 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-14 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-14 |
Time |
12:39 |
Sent To |
B |
|
| Notes |
| 2003-10-14 00:00:00 | TO RB DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-09-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-17 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-17 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2003-09-17 00:00:00 | ON COMM BD#63 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-04 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-04 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2003-08-04 00:00:00 | TO COMM BD #43 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-04-01 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-04-01 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-04-01 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2003-04-01 00:00:00 | COMM BOARD #60 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-02-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-02-06 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-02-04 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2003-02-06 00:00:00 | COM BOARD #54./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2002-11-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-04 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-04 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2002-11-04 00:00:00 | TO COMM BOARD #22./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-10-28 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-10-31 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2005-01-27 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-27 |
Time |
10:37 |
Rev Time |
1.50 |
| Received By |
prafter |
Date |
2005-01-27 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2005-01-27 00:00:00 | ORGINAL PLANS ARE KENNETH KRUGER PE. | | | SIGNED SEALED PLANS.561/434/4061. | | | AS BULT PLANS TO BE SAME ENG. | | | PAT RAFTER 561/805/6725 OR 805/6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2003-09-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-09-30 |
Time |
12:49 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-09-30 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2003-09-30 00:00:00 | PROVISO: | | | FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | | SHALL HAVE NOTIFICATION TO ALARM/STROBE | | | AS PER NFPA 90A 4-4.4.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2003-08-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-08-20 |
Time |
11:27 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-08-20 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2003-08-20 00:00:00 | PLEASE PROVIDE INFORMATION ON THE | | | SEPARATION BETWEEN THE BEDROOM AREAS. | | | PLANS INDICATE THE WALLS HAVING A 1 HR | | | FIRE RESISTANCE RATING.PLEASE PROVIDE | | | FIRE DAMPERS AS PER 2001 FBC(M) 607.1.2 | | | OR SHOW COMPLIANCE WITH 607.1.3 #3 ITEMS | | | 1 THROUGH 4. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2003-04-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-04-14 |
Time |
14:29 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-04-14 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2003-04-14 00:00:00 | DENIED: | | | | | | COMMENTS NOT ADDRESSED FROM 1ST & 2ND | | | PLAN REVIEW (SEE ATTACHED). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-02-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-18 |
Time |
14:27 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2003-02-18 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2003-02-18 00:00:00 | DENIED: | | | | | | 1.PLAN SHEET A(B)3 DETAIL 9, INDICATES | | | TENANT SEPARATION.CLARIFY FIRE | | | RESISTANCE RATING FOR THIS PARTITION. | | | SHOULD RATING BE 1 HR OR GREATER, FIRE | | | DAMPERS ARE REQUIRED AT EACH PENETRATION | | | AS PER 2001 FBC(M) 607.2.1. | | | | | | 2.AS PER 2001 FBC CHAPTER 13 SECTION | | | 407.1.ABCD.2.2.2 ZONES, HEATING AND | | | COOLING TO EACH ZONE SHALL BE CONTROLLED | | | BY INDIVIDUAL THERMOSTATIC CONTROLS | | | RESPONDING TO TEMPERATURE WITHIN THE | | | ZONE.A DWELLING UNIT IS CONSIDERED A | | | ZONE. | | | | | | 3.PROVIDE INFORMATION ON THE KITCHEN. | | | INDICATE ANY NEW EQUIPMENT.SEPARATE | | | PLANS & PERMIT REQUIRED FOR HOOD & FIRE | | | SUPRESSION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-11-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-11-19 |
Time |
17:55 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2002-11-26 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2002-11-26 00:00:00 | DENIED: | | | | | | PLANS ARE NOT CLEAR & HARD TO READ. | | | | | | AS PER 2001 FBC(M) 601.4, BALANCED AIR | | | RETURN REQUIRED.PROVIDE RETURN AIR | | | FROM ALL BEDROOM AREAS. | | | | | | INDICATE OCCUPANCY TYPE. | | | | | | PLAN SHEET A-2 INDICATES 2001 FBC & | | | 1997 ELEC, ENERGY, & ACCESSSIBILITY | | | CODES.PLEASE REFERENCE APPLICABLE | | | CODES. | | | | | | INDICATE ANY OF THEEXISTING WALLS | | | ARE FIRE RATED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2003-10-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-08 |
Time |
13:05 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-10-08 |
Time |
13:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2003-08-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-19 |
Time |
13:02 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-08-19 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2003-08-19 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLORIDA STATUTES | | | | | | 1) 61G15023.002(2) SEE ATTACHED SHEET. | | | ENGINEERS SHALL HAVE THEIR LICENSE NUM- | | | BER ON EACH SHEET. (IN TITLE BLOCK) | | | 2) ONLY THE FIXTURES WITHIN THE BATH- | | | ROOM GROUPS SHALL CONNECT TO THE WET- | | | VENTED HORIZONTAL BRANCH DRAIN. ANY | | | ADDITIONAL FIXTURES SHALL DISCHARGE | | | DOWNSTREAM OF THE WET VENT. SEC 909.1 | | | SEE ATTACHED SHEET FOR RISER DIAGRAM | | | THAT MEETS CODE REQUIREMENTS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2003-04-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-18 |
Time |
10:55 |
Rev Time |
1.75 |
| Received By |
kstevens |
Date |
2003-04-18 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2003-04-18 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FHA-98 AMEND. DESIGN MANUAL | | | | | | 1) FROM PREVIOUS REVIEWS. SHT A5 PLEASE | | | SUBMIT CALCULATIONS FOR PRIMARY AND | | | SECONDARY ROOF DRAINS FOR BOTH THE OLD | | | AND NEW ROOFS. (NEW PARAPET HEIGHT | | | EFFECTS BOTH ROOFS.) SHOW SQUARE FOOTAGE | | | FOR ALL ROOFS, INCLUDING 1/2 AREA OF ALL | | | VERTICAL WALLS AND ANY AREA OF ROOFS | | | THAT DRAIN ONTO THE ROOFS FROM ABOVE. | | | SEE SECTIONS 1106 & 1107. | | | 2) NOW THAT USAGE AND OCCUPANCY IS CLEAR | | | THE FAIR HOUSING ACT SHALL BE ENFORCED. | | | PLEASE SHOW COMPLIANCE WITH REQUIREMENTS | | | 1 THRU 7. SPECIFY "A" OR "B" TYPE BATH- | | | ROOMS. SHOW ALL BACKING PER REQUIREMENT | | | #6. SHOW ALL CLEAR FLOOR SPACE ON FLOOR | | | PLAN. SHOW ALL PROPER DIMENSIONS FOR | | | FIXTURES INCLUDING HEIGHT, CENTER OF | | | FIXTURE TO WALL ECT. | | | 4) WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-02-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-02-07 |
Time |
17:26 |
Rev Time |
1.75 |
| Received By |
kstevens |
Date |
2003-02-07 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2003-02-07 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) FROM PREVIOUS REVIEW: SHT A5 PLEASE | | | SUBMIT CALCULATIONS FOR PRIMARY AND | | | SECONDARY ROOF DRAINS FOR BOTH THE OLD | | | AND THE NEW ROOFS. (NEW PARPET HEIGHT | | | EFFECTS BOTH ROOFS). SHOW SQUARE FOOTAGE | | | FOR ALL ROOFS INCLUDING 1/2 AREA OF ALL | | | VERITCAL WALLS AND ANY AREA OF ROOFS | | | THAT DRAIN ONTO THE FOOFS FROM ABOVE. | | | SEE SECTIONS 1106 & 1107. | | | 2) WILL THIS BE AN ASSISTED LIVING | | | RESIDENCE? | | | 3) ALL BATHROOMS SHALL COMPLY WITH | | | CHAPTER 11 OF THE FBC-2001. | | | 4) WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDEN- | | | TIFYING THE SHEET OR SPECIFICATION PAGE | | | WHERE THE CHANGES CAN BE FOUND, WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-11-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-11-19 |
Time |
17:37 |
Rev Time |
3.00 |
| Received By |
kstevens |
Date |
2002-11-19 |
Time |
17:37 |
Sent To |
M |
|
| Notes |
| 2002-11-19 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 34 | | | FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) PLANS DO NOT HAVE SUFFICENT CLAIRITY | | | AND DETAIL TO INDICATE THE NATURE AND | | | CHARACTER OF THE WORK BEING DONE. PLANS | | | ARE SMUGED AND HARD TO READ. PLEASE SUB- | | | MIT PLANS THAT ARE CLEAR AND READABLE. | | | SEC 104.2.1 | | | 2) SHT A2 APPLICABLE CODES ARE FBC-2001 | | | NOT AS STATED ON PLANS. | | | 3) SHT A5 PLEASE SUBMIT CALCULATIONS FOR | | | PRIMARY AND SECONDARY DRAINS FOR BOTH | | | THE OLD AND NEW ROOFS. (NEW PARAPET | | | HEIGHT EFFECTS BOTH ROOFS). SHOW SQUARE | | | FOOTAGE FOR ALL ROOFS INCLUDING 1/2 AREA | | | OF ALL VERTICAL ROOFS AND ANY AREA OF | | | ROOFS THAT DRAIN ONTO ROOFS FROM ABOVE. | | | SECTION 1106 & 1107 | | | 4) PLEASE INDICATE THE NUMBER OF OCCU- | | | PANTS TO BE HOUSED AT THE FACILITY AND | | | SUBMIT CALCULATIONS FOR PLUMBING FACIL- | | | ITIES REQUIRED. SECTION 434.4.5.1. | | | 5) PLEASE SUBMIT AN EXISTING FLOOR PLAN | | | TO DETERMINE EXISTING FACILITIES. | | | 6) SHT EP1 PLUMBING NOTES #7, AIR CHAMB- | | | ERS ARE NOT APPROVED. DELETE REFERENCE. | | | 7) PLEASE SUBMIT DETAILS FOR BATHROOMS | | | PER SECTION 434.4.5.3. SHOW ALL GRAB | | | BARS REQUIRED FOR SHOWERS OR TUBS AND | | | FOR WATER CLOSETS. | | | 8) SECTION 434.4.3.1 REQUIRES A MINIMUM | | | LIVING & DINING SPACE OF 35 SQ FT PER | | | RESIDENT, LIVE IN STAFF, & LIVE IN FAM- | | | ILY MENBERS. PLEASE INDICATE ON PLANS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-10-31 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-10-31 |
Time |
08:26 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|