Plan Review Details - Permit 02101678
Plan Review Stops For Permit 02101678
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-02-03 Cont ID  
Sent By jwitmer Date 2003-01-31 Time 10:22 Rev Time 2.75
Received By jwitmer Date 2003-01-31 Time 09:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-11-26 Cont ID  
Sent By btrobaug Date 2003-01-29 Time 11:54 Rev Time 2.25
Received By jwitmer Date 2002-11-26 Time 17:08 Sent To  
Notes
2002-11-26 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02101678
 ADD: 207 NOTTINGHAM BLVD
 CONT: KENNITH SALUUCI INC
 TEL: (561)763-3280
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) ENERGY SHEET INDICATES INSULATION FOR
 BLOCK WALLS NOT THE R-11 FOR 2X6 FRAME
  
 3) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
  
 4) PLOT PLAN 2 COPIES REQUIRED.
  
 5)1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
  
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST.
 FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING REPORTS:
 A) SLIDING GLASS DOOR.
 B) IN SWING DOOR
 C) 2868 1 LITE OUTSWING DOOR
 D) STORM SHUTTERS
 PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
 FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 6) SHEET 7 STRUCTURAL NOTES: CORRECT
 WIND VELOCITY OF 110 TO 140 3 SECOND
 GUST
  
 7) 1707.3.1 JOIST HANGERS, FRAMING
 ANCHORS & SIMILAR DEVICES SHALL BE TEST-
 ED IN ACCORDANCE W/ ASTM D 1761 & BE
 LABELED AND LISTED FOR THEIR LOAD CARRY-
 ING CAPACITY.TYPICAL PORCH SECTION THIS
 REQUIRES THE TESTING OF TOP/ BPTTOM
 POST ATTACHMENTS.
  
 8) PROVIDE ADDITIONAL INFO, PROVIDE
 THE CALCS FOR THE MOMENT OF OVERTURNING
 FOR THE WALL SECTION THAT THE 3/16"
 TAPCONS ARE TO WITHSTAND.
  
 9) SHEET 7 SEC# 1 MISSING VERTICAL STEEL
 FOR STEM WALL?
  
 10) SHEET 5 & 6 DETAIL # 1 INDICATES THE
 USE OF HUGHES FASTENERS, OUT OF BUS-
 INESS FOR 2 YEARS.
  
 11) 2303.3 MISSING 15 LB FELT OR KRAFT
 WATERPROOF BUILDING PAPER TO PROTECT THE
 STRUCTURAL FRAMING & INTERIOR WALL
 COVERING.
  
 12) 1606.4.4 ANCHOR METHODS. PROVIDE
 INFORMATION FOR INSTALLATION OF DOOR
 AND WINDOW BUCKS.
  
 13) 1707.4.4.1 ANCHOR REQUIREMENTS:
 WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR
 ED IN ACCORDANCE WITH THE PUBLISHED
 MANUFACTURER'S RECOMMENDATIONS TO
 ACHIEVE THEDESIGN PRESSURE SPECIFIED.
 SUBSTITUTE ANCHORING SYSTEM USED FOR
 THE SUBSTRATE NOT SPECIFIED BY THE
 FENESTRATION MANUFACTURER SHALL PROVIDE
 EQUAL OR GREATER ANCHORING AS DEMONSTRA-
 TED BY ACCEPTED ENGINEERING PRACTICES.
  
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-01-29 Cont ID  
Sent By btrobaug Date 2003-01-29 Time 11:53 Rev Time 0.75
Received By btrobaug Date 2003-01-24 Time 16:10 Sent To B
Notes
2003-01-29 00:00:00TO JIM./WRT

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-11-21 Cont ID  
Sent By btrobaug Date 2003-01-16 Time 16:47 Rev Time 1.00
Received By btrobaug Date 2002-11-21 Time 06:45 Sent To B
Notes
2002-11-21 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE PROVIDE THE FOLLOWING
 INFORMATION AND RESUBMIT FOR REVIEW.
  
 1} THE PANEL SCHEDULE AND LOAD
 CALCULATION ON THE PLAN IS NOT
 CLEAR.PLEASE PROVIDE A PANEL SCHEDULE
 FOR ALL PANELS,WITH LOAD CALCULATIONS
 FOR SAME.
  
 2} INDICATE THE SIZE OF THE EXISTING
 SERVICE,AND THE SIZE OF THE PANEL(S)
 BEING ADDED,ALSO THE LOCATION.
  
 3} NOTE THE SMALL APPLIANCE CIRCUITS PER
 220-16@ 1500 VA.THERE ARE 3 LISTED @
 3000 VA.
  
 4} PLEASE LIST THE REQ'D BATH(S)
 CIRCUIT(S). PER 210-11-C-3
 MUST BE 20A AND #12AWG.
  
 5} PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CIRCUITS ON PANEL
 SCHEDULE PER 210-12.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT.8392

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-16 Cont ID  
Sent By btrobaug Date 2003-01-16 Time 16:47 Rev Time 0.00
Received By btrobaug Date 2003-01-16 Time 16:47 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-21 Cont ID  
Sent By btrobaug Date 2002-11-07 Time 18:42 Rev Time 0.00
Received By btrobaug Date 2002-11-07 Time 18:42 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-11-20 Cont ID  
Sent By kstevens Date 2002-11-18 Time 17:52 Rev Time 0.25
Received By pkrauss Date 2002-11-20 Time 16:35 Sent To E
Notes
2002-11-20 00:00:00NO MECHANICAL PLANS SUBMITTED FOR REVIEW
 ONLY 1 SET OF ENERGY & MANUAL J CALCS.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-11-18 Cont ID  
Sent By kstevens Date 2002-11-18 Time 17:51 Rev Time 0.25
Received By kstevens Date 2002-11-18 Time 17:22 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-11-07 Cont ID  
Sent By btrobaug Date 2002-11-21 Time 06:58 Rev Time 0.25
Received By sgraham Date   Time   Sent To B
Notes
***NONE***