| Plan Review Stops For Permit 02101626 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-02-11 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-02-11 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-02-11 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2003-02-11 00:00:00 | REVISION A3+ DATED 1/27/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-12-19 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-02-07 |
Time |
16:16 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-12-19 00:00:00 | PAID IMPACT FEES PER HAROLD PISKURA`S | | | PROVISO. HAS PRODUCT APPROVALS FOR | | | WINDOWS, DOORS, MULLIONS AND SLIDING | | | DOORS. | | | OK, PER HHP. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-12-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-11-20 |
Time |
14:56 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2002-11-26 |
Time |
15:24 |
Sent To |
E |
|
| Notes |
| 2002-11-26 00:00:00 | PROVISO: IMPACT FEES MUST BE PAID TO | | | THE COUNTY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-12-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-19 |
Time |
06:30 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-12-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-11 |
Time |
09:46 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2002-12-11 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2002-12-11 00:00:00 | **NOTE ** | | | | | | EQUIPMENT GROUND BETWEEN MAIN DISC AND | | | PANEL MISSING/ RELINED AND NOTED ON | | | PLAN. 250-122. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-27 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-11-26 |
Time |
15:56 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2002-11-27 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2002-11-27 00:00:00 | ***************** UNSAT ************* | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATING FOR | | | NEW MAIN AND PANEL. ALL MUST BE RATED | | | FOR THE AVAILABLE FAULT CURRENT. | | | | | | 2)NOTE: PLEASE LIST THE REQ`D BATH | | | CIRCUIT(S) PER 210-52D AND 210-11-C-3 | | | | | | 3)NOTE: PLEASE NOTE AHU/HEAT LOAD WAS | | | DEDUCTED IN THE REST OF THE LOAD | | | CALCS AND NEEDS TO BE FIGURED FROM | | | GENERAL LIGHTING AND RECEPT LOADS. | | | 220 NEC | | | | | | 4)NOTE: PLEASE NOTE, MISSING EQUIPMENT | | | GROUNDING CONDUCTOR BETWEEN MAIN AND | | | PANEL. 250-24 AND SIZE PER 250-122 | | | | | | 5)NOTE: PLEASE NOTE, MISSING RECEPT | | | FOR KITCHEN COUNTER PENINSULAR.210-52C-3 | | | GFI PER 210-8-A-6 | | | | | | 6)NOTE: PLEASE LIST THE REQ`D ARC FAULT | | | PROTECTED CIRCUITS PER 210-12 FOR NEW | | | BEDROOMS. | | | | | | 7)NOTE: PLEASE NOTE SD NEEDS TO BE A MIN | | | OF 3' FROM BATH DOOR. NFPA-72 8-1.4.1.6 | | | | | | 8)NOTE: PLEASE NOTE MISSING RECPET, 2' | | | OF WALL NEW BEDROOM. 210-52 | | | | | | | | | JUST A NOTE, IF THERE ARE GOING TO BE | | | NEW LOW VOLTAGE, (PHONE,CATV,SOUND) | | | PLEASE SHOW ON PLANS IN ORDER TO BE | | | PERMITTED UNDER THE WORK.IF NOT A | | | SEPARATE PERMIT WILL BE REQ`D AND SEPAR- | | | ATE LAYOUT SUBMITTED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-01-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-29 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-01-29 |
Time |
16:03 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-18 |
Time |
17:48 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-10-24 |
Time |
17:47 |
Sent To |
P |
|
| Notes |
| 2002-11-18 00:00:00 | TO P IN BOX./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-11-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-11-18 |
Time |
18:30 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-11-20 |
Time |
14:49 |
Sent To |
B |
|
| Notes |
| 2002-11-20 00:00:00 | PROVISO: | | | | | | PLEASE NOTE AHU IN GARAGE SHALL BE | | | PROTECTED FROM DAMAGE AS PER 2001 | | | FBC(M) 303.4. | | | | | | SMOKE DETECTORS SHALL BE INSTALLED | | | SUPPLY SYSTEMS WITH A DESIGN CAPACITY | | | GREATER THAN 2,000 CFM, IN THE SUPPLY | | | AIR DUCT. 2001 FBC(M) 606.2.1OR | | | UPON ACTIVATION, THE SMOKE DETECTORS | | | SHALL SHUTDOWN THE AIR DISTRIBUTION | | | SYSTEM. 2001 FBC(M) 606.4 | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-11-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-18 |
Time |
17:48 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2002-11-18 |
Time |
18:30 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-02-07 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-02-07 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-11-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-29 |
Time |
16:03 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
|
|