Plan Review Details - Permit 02101626
Plan Review Stops For Permit 02101626
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-02-11 Cont ID  
Sent By hpiskura Date 2003-02-11 Time 09:42 Rev Time 0.00
Received By hpiskura Date 2003-02-11 Time 09:41 Sent To  
Notes
2003-02-11 00:00:00REVISION A3+ DATED 1/27/03

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-12-19 Cont ID  
Sent By sgraham Date 2003-02-07 Time 16:16 Rev Time 0.50
Received By dpalmer Date   Time   Sent To  
Notes
2002-12-19 00:00:00PAID IMPACT FEES PER HAROLD PISKURA`S
 PROVISO. HAS PRODUCT APPROVALS FOR
 WINDOWS, DOORS, MULLIONS AND SLIDING
 DOORS.
 OK, PER HHP.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-12-19 Cont ID  
Sent By pkrauss Date 2002-11-20 Time 14:56 Rev Time 0.50
Received By dpalmer Date 2002-11-26 Time 15:24 Sent To E
Notes
2002-11-26 00:00:00PROVISO: IMPACT FEES MUST BE PAID TO
 THE COUNTY.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-12-19 Cont ID  
Sent By dpalmer Date 2002-12-19 Time 06:30 Rev Time 0.50
Received By dpalmer Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-12-11 Cont ID  
Sent By dpalmer Date 2002-12-11 Time 09:46 Rev Time 0.50
Received By dpalmer Date 2002-12-11 Time 09:46 Sent To  
Notes
2002-12-11 00:00:00**NOTE **
  
 EQUIPMENT GROUND BETWEEN MAIN DISC AND
 PANEL MISSING/ RELINED AND NOTED ON
 PLAN. 250-122.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-11-27 Cont ID  
Sent By hpiskura Date 2002-11-26 Time 15:56 Rev Time 1.00
Received By dpalmer Date 2002-11-27 Time 09:47 Sent To  
Notes
2002-11-27 00:00:00***************** UNSAT *************
  
 1)NOTE: PLEASE SUBMIT AIC RATING FOR
 NEW MAIN AND PANEL. ALL MUST BE RATED
 FOR THE AVAILABLE FAULT CURRENT.
  
 2)NOTE: PLEASE LIST THE REQ`D BATH
 CIRCUIT(S) PER 210-52D AND 210-11-C-3
  
 3)NOTE: PLEASE NOTE AHU/HEAT LOAD WAS
 DEDUCTED IN THE REST OF THE LOAD
 CALCS AND NEEDS TO BE FIGURED FROM
 GENERAL LIGHTING AND RECEPT LOADS.
 220 NEC
  
 4)NOTE: PLEASE NOTE, MISSING EQUIPMENT
 GROUNDING CONDUCTOR BETWEEN MAIN AND
 PANEL. 250-24 AND SIZE PER 250-122
  
 5)NOTE: PLEASE NOTE, MISSING RECEPT
 FOR KITCHEN COUNTER PENINSULAR.210-52C-3
 GFI PER 210-8-A-6
  
 6)NOTE: PLEASE LIST THE REQ`D ARC FAULT
 PROTECTED CIRCUITS PER 210-12 FOR NEW
 BEDROOMS.
  
 7)NOTE: PLEASE NOTE SD NEEDS TO BE A MIN
 OF 3' FROM BATH DOOR. NFPA-72 8-1.4.1.6
  
 8)NOTE: PLEASE NOTE MISSING RECPET, 2'
 OF WALL NEW BEDROOM. 210-52
  
  
 JUST A NOTE, IF THERE ARE GOING TO BE
 NEW LOW VOLTAGE, (PHONE,CATV,SOUND)
 PLEASE SHOW ON PLANS IN ORDER TO BE
 PERMITTED UNDER THE WORK.IF NOT A
 SEPARATE PERMIT WILL BE REQ`D AND SEPAR-
 ATE LAYOUT SUBMITTED.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-29 Cont ID  
Sent By dpalmer Date 2003-01-29 Time 16:03 Rev Time 0.00
Received By dpalmer Date 2003-01-29 Time 16:03 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-18 Cont ID  
Sent By btrobaug Date 2002-11-18 Time 17:48 Rev Time 0.00
Received By btrobaug Date 2002-10-24 Time 17:47 Sent To P
Notes
2002-11-18 00:00:00TO P IN BOX./WRT.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-11-20 Cont ID  
Sent By kstevens Date 2002-11-18 Time 18:30 Rev Time 0.35
Received By pkrauss Date 2002-11-20 Time 14:49 Sent To B
Notes
2002-11-20 00:00:00PROVISO:
  
 PLEASE NOTE AHU IN GARAGE SHALL BE
 PROTECTED FROM DAMAGE AS PER 2001
 FBC(M) 303.4.
  
 SMOKE DETECTORS SHALL BE INSTALLED
 SUPPLY SYSTEMS WITH A DESIGN CAPACITY
 GREATER THAN 2,000 CFM, IN THE SUPPLY
 AIR DUCT. 2001 FBC(M) 606.2.1OR
 UPON ACTIVATION, THE SMOKE DETECTORS
 SHALL SHUTDOWN THE AIR DISTRIBUTION
 SYSTEM. 2001 FBC(M) 606.4
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-11-18 Cont ID  
Sent By btrobaug Date 2002-11-18 Time 17:48 Rev Time 0.25
Received By kstevens Date 2002-11-18 Time 18:30 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2003-02-07 Cont ID  
Sent By sgraham Date 2003-02-07 Time 16:15 Rev Time 0.00
Received By sgraham Date   Time   Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-11-18 Cont ID  
Sent By dpalmer Date 2003-01-29 Time 16:03 Rev Time 0.25
Received By sgraham Date   Time   Sent To B
Notes
***NONE***