Plan Review Details - Permit 02101434
Plan Review Stops For Permit 02101434
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-01-31 Cont ID  
Sent By rmcdouga Date 2003-01-31 Time 14:49 Rev Time 3.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-01-31 00:00:00BUILDING PROVISO
  
 1) SUBMIT THE CORRECT DRAWINGS FOR THE
 DOOR PRODUCT APPROVAL THAT WAS SUBMITTED
 FOR REVIEW PRIOR TO INSTALLING THE DOORS
  
 2) NO EGRESS OPENING FROM SLEEPING ROOMS
 ARE TO BE WITHIN ENCLOSED AREA.
  
 3) ENERGY CALCULATIONS WILL BE REQUIRED
 TO BE SUBMITTED WITH APPLICATION FOR
 MECHANICAL PERMIT IF ROOM IS TO BE
 MECHANICALLY HEATED OR COOLED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-12-02 Cont ID  
Sent By btrobaug Date 2003-01-17 Time 17:33 Rev Time 3.00
Received By btrobaug Date   Time   Sent To  
Notes
2002-11-27 00:00:00BUILDING DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) THE DRAWINGS ARE REQUIRED TO BEAR THE
 NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN PER CITY OF
 WPB AMENDMENTS SECTION 104.2.1.
  
 3) PROVIDE ENERGY CALCULATION FORMS PER
 FBC CHAPTER 13.
  
 4) SPECIFY THE CEILING INSULATION ON THE
 PLANS.
  
 5) STUCCO ON METAL LATH OVER SOLID BASE
 IS REQUIRED TO BE 7/8" THICK PER ASTM C
 926. REVISE PLAN.
  
 6) A MOISTURE BARRIER OF 15# FELT IS
 REQUIRED BETWEEN LATH AND WOOD SHEATHING
 PER FBC 2303.3. INDICATE ON PLANS.
  
 7) INDICATE ON THE PLANS HOW THE NEW
 WALLS WILL BE ATTACHED AT THE TOP TO THE
 EXISTING BEAM.
  
 8) INDICATE ATTIC VENTILATION ON THE
 PER FBC 2309.7.
  
 9) ENCLOSING CARPORT CAN NOT BLOCK
 EGRESS WINDOWS FROM EXISTING BEDROOMS.
  
 10) THE FINISH FLOOR ELEVATION AT
 HABITABLE AREAS SHALL BE A MINIMUM OF
 4" ABOVE FINISH GRADE PER CITY AMENDMENT
 1807.1.7.
  
 11) CLEARANCE BETWEEN WOOD SHEATHING,
 FRAMING,ETC. AND EARTH ON THE EXTERIOR
 OF A BUILDING OR THE EXTERIOR WALL
 COVERING AND FINAL EARTH GRADE SHALL NOT
 BE LESS THAN 6". INDICATE ON THE PLANS.
  
 12) THE ANCHOR BOLT SPACING IS REQUIRED
 TO BE SPACED 25" O.C. WITHIN 8' OF
 CORNERS PER WFC MANUAL.
  
 13) ANCHOR BOLTS ARE REQUIRED TO HAVE
 3" SQUARE WASHERS.
  
 14) PROVIDE (2) COPIES OF ALL PRODUCT
 APPROVALS.
  
 15)PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS.
  
 16) IF THE NEW WINDOW IS ACTUALLY TWO
 WINDOWS MULLED TOGETHER, THEN SUBMIT
 PRODUCT APPROVALS FOR MULLIONS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-12-02 Cont ID  
Sent By btrobaug Date 2002-12-02 Time 08:50 Rev Time 0.25
Received By btrobaug Date 2002-12-02 Time 08:48 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-17 Cont ID  
Sent By btrobaug Date 2003-01-17 Time 17:33 Rev Time 0.00
Received By btrobaug Date 2003-01-17 Time 17:33 Sent To B
Notes
2003-01-17 00:00:00MISC./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-14 Cont ID  
Sent By btrobaug Date 2002-11-14 Time 16:59 Rev Time 0.00
Received By btrobaug Date 2002-11-14 Time 16:58 Sent To B
Notes
2002-11-14 00:00:00TO B MISC./WRT.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-11-13 Cont ID  
Sent By sgraham Date 2002-11-13 Time 16:34 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***