| Plan Review Stops For Permit 02101307 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
11 |
Status |
P |
Date |
2006-03-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-03-03 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2006-03-03 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
10 |
Status |
F |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-07 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-07 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2006-02-07 00:00:00 | ******* UNSAT ****** | | | | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW WHICH NEED TO BE ADDRESSED. | | | | | | | | | 1)NOTE: PLEASE SEE NOTE # 4 FROM | | | PREVIOUS REVIEW. PLEASE INDICATE THE KW | | | RATINGS FOR POOL HEATERS. | | | PLEASE BE SURE ALL CONTINUOUS LOADS ARE | | | FIGURED AT 125%, POOL PUMP(S), POOL | | | HEATER(S). | | | PLEASE SEE LOAD SHOWN ON POOL PANEL IS | | | ALREADY SHOWN AT 96A'S WHICH IS OF | | | CONCERN WITH THE ADDED LOADS FROM | | | ORIGINAL PLANS. | | | | | | | | | 2)NOTE: PLEASE INDICATE ALL THE KW | | | RATINGS FOR A/C EITH CU'S OR AHU'S | | | WHICHEVER LOAD IS GREATER. | | | THE LOADS SHOWN ON THE PANEL SCHEDULE(S) | | | MENTIONS THE LOADS ALREADY @65%, HOWEVER | | | EACH AHU SEEMS TO BE ABOUT 5KW OR SO, | | | WHICH @65% WOULD NOT BE THE LOADS SHOWN. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE ALL SUB PANELS ARE | | | NOW INDICATED AS "GARAGE PANELS"? | | | PLEASE CORRELATE THE IDENTIFICATION WITH | | | RISER. | | | | | | 4)NOTE: PLEASE SEE RISER NOW SHOWS A | | | DISCONNECTING MEANS AHEAD OF THE GARAGE | | | PANEL "E', YET PLANS DO NOT SHOW THIS | | | DISCONNECT. PLEASE ALSO SEE RISER WHICH | | | SHOWS A MCB IN PANEL AT GARAGE? | | | PLEASE CORRLELATE. | | | PLEASE SEE THE EQUIPMENT GROUNDING | | | CONDUCTOR FROM PANEL "C" IN MAIN HOUSE | | | IS NOW MISSING TO THE GARAGE PANEL "E". | | | PLEASE SEE 250.32. | | | AN EQUIPMENT GROUNDING CONDUCTOR IS | | | REQUIRED; THE ONLY EXCEPTION IS IF THERE | | | ARE COMPLETELY NO OTHER METAL PARTS | | | CONNECTED BETWEEN BLDGS. THIS WOULD BE , | | | WATER PIPES, CATV, PHONE ETC. | | | THE CHANCES OF THERE BEING NO METALS | | | PATHS OR FUTURE PHONE ETCIS VERY | | | UNLIKELY. | | | PLEASE INCLUDE THE EQUIPMENT GROUND AS | | | SHOWN ON PREVIOUS PLANS. | | | | | | 5)NOTE: PLEASE SEE LOAD CALCUALTIONS | | | PROVIDE DO NOT PROVIDE ENOUGH | | | INFORMATION FOR REVIEW OF MINS' | | | REQUIRED. PLEASE EITHER SHOW A BREAK | | | DOWN OR INDICATE THE VA/KW ON PANEL | | | SCHEDULES. ( SMALL APPL, LAUNDRY/WASHER, | | | DRYER ETC ETC. | | | 220,215.5 | | | | | | NEW NOTE: | | | | | | 6)NOTE: PLEASE SEE GARAGE SHOWS A 220V | | | RECEPT, HOWEVER THIS IS NOT ON PANEL | | | SCHEDULE FOR GARAGE. | | | 215.5 | | | | | | ** PLEASE KNOW, THIS OFFICE IS UNABLE TO | | | VERIFY CORRECT OCP AND AWG FOR SOME | | | CIRCUITS AS LOADS ARE NOT SHOWN OR GIVEN | | | IN BREAKDOWN OF PANELS AND LOAD | | | CALCULATIONS. | | | PLEASE ALSO SEE DE-RATING OF SUB PANELS | | | MAY NOT BE DONE FOR ALL MOTOR/HEAT LOADS | | | . | | | | | | | | | PELASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
F |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-20 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-20 |
Time |
07:11 |
Sent To |
PC |
|
| Notes |
| 2006-01-20 00:00:00 | ************ UNSAT ************ | | | | | | | | | 1)NOTE: PLEASE CORRELATE ALL CIRCUITING | | | ON PLANS WITH PANEL SCHEDULES. | | | PLEASE SEE LTS ON SMALL APPL, LTS ON | | | DRYER, BATHS, KIT, APPLIANCES, ETC ETC. | | | PLEASE SEE THERE ARE FAR TOO MANY TO | | | WRITE UP OR REDLINE. PLEASE SEE MANY OF | | | THESE WERE REDLINED, HOWEVER BY NO MEANS | | | ALL. | | | | | | 2)NOTE: PLEASE SEE SMOKE DETECTORS'S | | | SHOWN ON THREE OR MORE CIRCUITS. PLEASE | | | SEE NFPA-72 8-1 WHICH REQUIRES SD'S TO | | | BE WIRED "IN-LINE". IF WIRED IN-LINE, | | | THEN THESE CAN NOT BE ON MORE THAN ONE | | | CIRCUIT. ALSO SHOWN ON MULTIPLE PANELS. | | | | | | 3)NOTE: PLEASE SEE 210.52D,210.11C3, | | | WHICH REQUIRES ALL BATH(S) CIRCUIT(S) | | | RECEPTS TO BE ON A MIN OF 20A AND #`12. | | | PLEASE SEE CIRCUITING AS MANY ARE SHOWN | | | ON OTHER CIRCUITS WHICH ARE 15A AND #14 | | | AWG. | | | | | | 4)NOTE: PLEASE CORRELATE ALL POOL | | | EQUIPMENT ON PLANS WITH PANEL SCHEDULES | | | AND LOAD CALCUALTIONS. PLEASE SEE | | | CIRCUITING ON PLANS IS ALSO SHOWN AS | | | COND UNITS.?? | | | PLEASE SEE PLANS SHOW TWO ELEC POOL | | | HEATERS, HOWVER PANEL SCHEDULE SHOWS | | | ONE?? | | | PLEASE ALSO SEE ALL CONTINUOUS LOADS | | | SUCH AS POOL HEATER AND POOL PUMP SHALL | | | BE SHOWN AT 125%. 215.3,230.42, | | | PLEASE SEE MIN OCP SHALL BE SIZED AT | | | 125% PER 680.9. PLEASE PROVIDE KW | | | RATINGS FOR POOL HEATERS. | | | | | | 5)NOTE: PLEASE SEE PLANS, CLEARENCES FOR | | | CU DISCONNNECTS DO NOT MEET 110.26. | | | PLEASE ALSO SEE ANY AHU'S WHICH APPEAR | | | TO SHOW SHELVING DIRECTLY INFRONT OF | | | THESE DISCONNECTS AND UNITS. | | | | | | 6)NOTE: PLEASE SEE CORRELATE PANEL | | | SCHEDULES AND RISER DIAGRAM. PLEASE SEE | | | ALL PANELS INDICATE MAINS (A | | | GARAGE PANEL REQUIRED) HOWEVER PANELS | | | FOR POOL PANEL AND PANEL C SHOWS MLO ON | | | SCHEDULE AND SHOWS MAIN DISCONNECT ON | | | RISER?? PLEASE CORRELATE. | | | 215.5 | | | | | | 7)NOTE: PLEASE SEE PLANS SHOWS POOL | | | PANEL AND A PANEL "D"?? | | | PLEASE CORRELATE.215.5 | | | | | | 8)NOTE: PLEASE SEE CIRCUITS SHOWN ON | | | PLANS AS GEN LTS, PELASE SEE CIRCUITING | | | SHALL BE SPECIFIC TO AREA/ROOMS. | | | 215.5, 408.4 | | | | | | 9)NOTE: PLEASE SEE KITCHEN AREA WHERE | | | APPEARS TO BE A MISSING COUNTERSPACE GFI | | | RECEPT. 210.52C1 | | | SEE CIRCUITING, REDLINED. | | | | | | 10)NOTE: PLEASE SEE ALL RECEPTS SERVING | | | KITCHEN/KITCHEN AREA COUNTERSPACE ARE TO | | | BE GFI/GFI PROTECTED. | | | | | | 11)NOTE: PLEASE INDICATE THE KW RATINGS | | | FOR AHU'S AND HEAT BEING USED FOR LOAD | | | CALCS. | | | 215.5. | | | | | | 12)NOTE: PLEASE SEE PANEL "B" WHICH | | | INDICATES A SEPARATE OVEN AND A SEPRATE | | | RANGE, HOWEVER LOAD CALCS SEEMT O ONLY | | | SHOW 8KW FOR BOTH UNITS?? | | | PLEASE VERIFY AND ADJUST AS CIRCUITS | | | SEEM TO BE FOR MORE THAN 8KW FOR BOTH. | | | 215.5, 220 | | | | | | 13)NOTE: PLEASE SEE AN EQUIPMENT | | | GROUNDING CONDUCTOR IS STILL BEING SHOWN | | | FROM METER TO THE FIRST MEANS OF | | | DICCONNECT. PLEASE SEE 250.6, 250.24 THE | | | "EQUIPMENT GROUNDING CONDUCTOR" IS ONLY | | | INSTALLED "AFTER" THE FIRST MEANS OF | | | DISCONNECT. | | | | | | PLEASE BE SURE TO CORRELATE ALL | | | CIRCUITING ON PLANS WITH PANEL | | | SCHEDULES. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW AND STAMPING. IF THERE ARE ANY | | | QUESTIONS, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2005-10-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-10-13 |
Time |
11:11 |
Rev Time |
0.40 |
| Received By |
dpalmer |
Date |
2005-10-13 |
Time |
11:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2005-09-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-30 |
Time |
15:34 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-09-30 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2005-09-30 00:00:00 | ****** UNSAT ****** | | | | | | | | | 1)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | WITH PANEL SCHEDULES. | | | PLEASE SEE PANEL "A" IS SHOWN FEEDING | | | BOTH SUB PANELS, HOWEVER RISER INDICATES | | | ONE SUB PANEL FROM "A" AND ONE FROM | | | "B"?? | | | | | | | | | 2)NOTE: PLEASE SEE TWO NEW MAIN | | | DISCONNECTS ADDED TO RISER. | | | PLEASE SUBMIT AIC RATINGS FOR NEW MAINS | | | PER 110.9, 215.5 | | | PLEASE NOW SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTORS FROM MAINS TO | | | PANELS "A" AND "B". | | | 250.110, 250.24, 250.122 | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-14 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-09-14 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2005-09-14 00:00:00 | ****** UNSAT ******** | | | | | | 1)NOTE: PLEASE SEE PANEL SCHEDULES NOW | | | SUBMITTED ONLY INDICATE THE ITEM AND | | | CIRCUIT NUMBER. | | | PLEASE SEE MISSING OVERCURRENT | | | PROTECTIVE DEVICE FOR EACH. | | | SUB-PANELS ETC. | | | PLEASE SEE MISSING CONDUCTOR SIZES FOR | | | EACH. | | | PLEASE SEE THE PANEL SCHEDULES AS SHOWN | | | ON PLANS, WOULD IN-FACT BE WHAT MAY BE | | | INSIDE THE PANEL AT JOB-SITE. | | | | | | 2)NOTE: PLEASE SEE THAT LOAD | | | CALCULATIONS ARE NOW MISSING FROM EACH | | | OF THE PANEL SCHEDULES AND ONLY THE LOAD | | | IS SHOWN FOR THE SERVICE. | | | CAN NOTVERIFY CONDUCTORSIZES ETC. | | | 220., 215.5, | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2003-10-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-07 |
Time |
15:00 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-10-20 |
Time |
06:26 |
Sent To |
P |
|
| Notes |
| 2003-10-20 00:00:00 | *************** UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE THAT ONE SET OF PLANS | | | HAVE COME FOR A RE-STAMP, YET PLANS | | | HAS CHANGES ON PLANS, THEREFORE MAKING' | | | THESE "REVISIONS". | | | PLEASE SEE THAT ONLY ONE SET WAS SUB- | | | -MITTED FOR STAMPING AND TWO SETS REQ'D | | | DUE TO REVISIONS. | | | | | | 2)NOTE: PLEASE ALSO SEE PLANS NEED TO BE | | | SIGNED, DATED AND SEALED BY THE ARCH OF | | | RECORD. FAC 61G1-16.004, FS 481.221. | | | | | | 3)NOTE: PLEASE SEE RISER, LAST REV | | | CONTAINED CONDUCTOR SIZE FROM GUTTTER | | | TO DISC FOR ELEVATOR. PLEASE SEE THIS IS | | | NOW MISSING.? PLEASE CORRECT.SEE 240.21 | | | FOR TAPPED CONDUCTORS. | | | 4)NOTE: PLEASE CLARIFY GFI RECEPT REQ'D | | | FOR A/C COND UNITS. 210.63 | | | | | | 5)NOTE: PLEASE SEE PLANS, HIGHLIGHTED | | | FOR RECEPTS MISSING PER 210.52. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. REVISIONS FEES ARE NOW DUE FOR | | | ELECTRICAL PLANS. PLEASE ALSO SEE NOTES | | | FROM OTHER REVIEWERS AND FEE THAT MAY | | | BE DUE FOR OTHER TRADES ALSO. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-09-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-16 |
Time |
09:42 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-09-26 |
Time |
10:53 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-07-31 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-24 |
Time |
15:22 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-07-31 |
Time |
11:34 |
Sent To |
P |
|
| Notes |
| 2003-07-31 00:00:00 | *************** UNSAT **************** | | | | | | 1)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | AND PANELS. RISER SHOWS PANELS AS MCB | | | AND PANEL SHOWN AS MLO? | | | | | | 2)NOTE: PLEASE ALSO SEE LOAD CALCULATION | | | -S, PLEASE RECONFIGURE AND CLARIFY | | | SUB PANEL AND TOTAL LOAD ON SERVICE. | | | 500MCM ID GOOD FOR 380A'S PER 310-16. | | | PLEASE SEE THAT 310-15 B6 MAY BE USED | | | BUT STOPS AT 400MCM FOR A 400A SERVICE. | | | 460A SERV SHOWN. | | | PLEASE ALSO CLARIFY WHERE SUB PANEL, | | | PANEL SCHEDULE IS? | | | | | | 3)NOTE: PLEASE SUBMIT REVISED PLANS, IN | | | ORDER TO VERIFY SERVICE AND LOCATIONS | | | OF PANELS. | | | | | | 4)NOTE: PLEASE SHOW ALL REVISIONS WITH | | | CLOUDS AND TRIANGLES. | | | | | | 5)NOTE: PLEASE SEE MISSING CONDUCTOR | | | SIZES ON RISER FOR SUB PANEL FROM GUTTER | | | PER 240-21 . | | | | | | 6)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTORS FOR ELEV MOTOR, | | | 250-110/250-122 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-01-21 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-30 |
Time |
16:25 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-01-21 |
Time |
08:38 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-16 |
Time |
18:00 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2002-11-05 |
Time |
12:20 |
Sent To |
B |
|
| Notes |
| 2002-11-05 00:00:00 | ************** UNSAT ************** | | | | | | 1)NOTE: PLEASE CORRELATE AHU`S ON MECH | | | PLANS W/ UNITS SHOWN ON ELECTRICAL | | | PLANS. PLEASE NOTE CIRCUITING NEED TO | | | CORRELATE WITH SUBMITTED PANEL SCHEDULES | | | PLEASE NOTE FOUR AHU`S ARE SHOWN ON | | | PLANS AND ONLY THREE CU`S ? | | | PLEASE CLARIFY | | | | | | 2)NOTE: PLEASE NOTE DISCONNECT FOR | | | ELEVATOR EQUIPMENT MUST BE SERVICE | | | ENTRANCE RATED AND SUBMIT AIC RATING FOR | | | DISC. 215-5,110-9 | | | | | | 3)NOTE: PLEASE CLARIFY SIZE OF COLD | | | WATER PIPE ON RISER DIAGRAM 3/9"? | | | | | | 4)NOTE: PLEASE SHOW ROOM DESIGNATION ON | | | PLANS. | | | | | | 5)NOTE: PLEASE NOTE CLEARENCE FOR CU | | | DISC`S PER 110-26 | | | | | | 6)NOTE: PLEASE NOTE PANELS ARE SHOWN | | | W/OUT MCB`S? 225-31/240/ RISER SHOWS | | | 2P/200`S | | | 7)NOTE: PLEASE NOTE LOAD CALCULATIONS | | | DO NOT INCLUDE SAUNA EQUIPMENT/LOADS? | | | PLEASE CORRELATE. | | | | | | 8)NOTE: PLEASE NOTE , PANEL SCHEDULE | | | ONLY SHOWS ONE WATER HEATER? PLEASE | | | CLARFIY, SECOND WATER HEATER AT 1500W? | | | | | | 9)NOTE:PLEASECLARIFY LOADS SHOWN FOR | | | A/C CU`S. | | | | | | PLEASE SUBMIT THE ABOVE INFORMAITON FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-06 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-06 |
Time |
16:28 |
Sent To |
E |
|
| Notes |
| 2006-02-06 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2006-01-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-19 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-19 |
Time |
14:49 |
Sent To |
E |
|
| Notes |
| 2006-01-19 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2005-10-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-12 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-12 |
Time |
13:49 |
Sent To |
E |
|
| Notes |
| 2005-10-12 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-29 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-29 |
Time |
15:02 |
Sent To |
E |
|
| Notes |
| 2005-09-29 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2005-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-12 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-12 |
Time |
13:57 |
Sent To |
B |
|
| Notes |
| 2005-09-12 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2004-12-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-06 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-06 |
Time |
16:18 |
Sent To |
M |
|
| Notes |
| 2004-12-06 00:00:00 | SENT TO "M/AC" BOX./REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2004-11-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-08 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-08 |
Time |
14:49 |
Sent To |
B |
|
| Notes |
| 2004-11-08 00:00:00 | TO RM DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2004-10-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-07 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-07 |
Time |
15:00 |
Sent To |
E |
|
| Notes |
| 2004-10-07 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-08-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-24 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-24 |
Time |
15:38 |
Sent To |
B |
|
| Notes |
| 2004-08-24 00:00:00 | TO RM DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2003-10-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-16 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-16 |
Time |
09:41 |
Sent To |
E |
|
| Notes |
| 2003-10-16 00:00:00 | TO DP DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-09-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-24 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-24 |
Time |
15:22 |
Sent To |
E |
|
| Notes |
| 2003-09-24 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-07-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-30 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-30 |
Time |
16:25 |
Sent To |
E |
|
| Notes |
| 2003-07-30 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-07-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-07-30 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-25 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2003-07-25 00:00:00 | TO ROB M DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-03-13 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-13 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-13 |
Time |
10:30 |
Sent To |
B |
|
| Notes |
| 2003-03-13 00:00:00 | SENT TO RM DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-03-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-06 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-03-06 |
Time |
11:02 |
Sent To |
M |
|
| Notes |
| 2003-03-06 00:00:00 | TO MECH INBOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-01-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-16 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-16 |
Time |
18:00 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-01-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-06 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-01-06 |
Time |
17:35 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2004-12-16 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2004-12-16 00:00:00 | CALLED MECHANICAL CONTRACTOR - | | | MECHANICAL REVISION CANNOT BE APPROVED | | | UNIL THE ARCHITECT REVISES HIS DESIGN. | | | ARCHITECT INDICATES RADIATION DAMPERS. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2004-10-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-28 |
Time |
06:45 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-10-27 |
Time |
16:28 |
Sent To |
R |
|
| Notes |
| 2004-10-28 00:00:00 | PROVISO: | | | AS PER 1ST REVIEW - | | | 1.PLAN SHEET M.3 FLEXIBLE DUCT | | | CONNECTION DETAIL, THIS DETIAL DOES NOT | | | INDICATE OR REFERENCE THE REQUIREMENT | | | FOR A FIRE DAMPER THAT IS DETAILED ON | | | PLAN SHEET A.5. | | | | | | 2.PLAN STILL DOES NOT INDICATE TOILET | | | EXHAUST TERMINATIONS AS SCREENED.THIS | | | IS REQUIRED ON EXHAUST WITH THE | | | EXCEPTION BEING FOR THE DRYER AND HOOD | | | EXHAUST.2001 FBC(M) 401.6, 504.4 & | | | 505.1. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2003-10-30 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2004-10-23 |
Time |
14:50 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-10-30 |
Time |
14:39 |
Sent To |
R |
|
| Notes |
| 2003-10-30 00:00:00 | ONLY ONE SET OF PLANS SUBMITTED.THIS | | | SUBMITTAL IS A REVISION, PLEASE PROVIDE | | | ADDITIONAL COPY FOR OUR RECORDS.AS PER | | | 2001 FBC 104.2.1. | | | | | | PLANS ARE NOT SIGNED, SEALED OR DATED | | | AS REQUIRED BY F.S. 481.221.PLANS | | | OTHERWISE ARE CODE COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2003-08-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-25 |
Time |
06:13 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-08-09 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2003-08-09 00:00:00 | 3ED FLOOR REVISION ONLEY.NO MECHANICAL | | | CHANGE ON REVISED PLAN. | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2003-03-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-04 |
Time |
12:46 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-03-10 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2003-03-10 00:00:00 | PROVISO: | | | | | | RADIATION DAMPERS REQUIRED, SEE PLAN | | | SHEET A.5 FOR DETAIL. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2003-03-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-03-06 |
Time |
12:33 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-03-06 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2003-03-06 00:00:00 | DENIED: | | | | | | PLEASE NOTE, ONE SET OF PLANS WERE | | | INADVERTENTLY STAMPED.DENIED COMMENTS | | | WERE ATTACHED TO THE RESUB APPLICATION. | | | | | | PLEASE ADDRESS THE FOLLOWING: | | | PLAN SHEET A.1 NOTE INDICATES ONE HOUR | | | PROTECTION W/UL DESIGN L521 THROUGHOUT. | | | | | | THE MECHANICAL PLANS DO NOT REFLECT THIS | | | TYPE OF CONSTRUCTION.PLEASE PROVIDE | | | INFORMATION ON THE PROTECTION FOR THE | | | HVAC SYSTEMS.ITEMS #4 & 5 IN THE UL | | | L521 LISTING, INDICATE UL CLASS 0 OR 1 | | | FOR THE DROPS. | | | | | | PLEASE REFLECT THE ASSEMBLY ON THE | | | MECHANICAL PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-01-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-06 |
Time |
11:03 |
Rev Time |
1.45 |
| Received By |
pkrauss |
Date |
2003-01-21 |
Time |
09:39 |
Sent To |
R |
|
| Notes |
| 2003-01-21 00:00:00 | PLAN SHEET A.1 NOTE INDICATES ONE HOUR | | | PROTECTION W/UL DESIGN L 521 THROUGHOUT. | | | | | | THE MECHANICAL PLANS DO NOT REFLECT THIS | | | TYPE OF CONSTRUCTION.PLEASE PROVIDE | | | INFORMATION ON THE PROTECTION FOR THE | | | HVAC SYSTEMS. ITEMS #4 & 5 IN THE UL L | | | 521 INDICATE UL CLASS 0 OR 1 FOR THE | | | DUCTWORK & CEILING DAMPERS REQUIRED FOR | | | THE DROPS. | | | | | | PLEASE CLARIFY THE ASSEMBLY ON THE | | | MECHANICAL PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-11-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-11-03 |
Time |
10:21 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2002-11-03 |
Time |
10:21 |
Sent To |
E |
|
| Notes |
| 2002-11-03 00:00:00 | PASS/PROVISO | | | 1) NEED MODEL NUMBERS OF ALL THREE | | | EVAPORATOR COILS FOR FINAL | | | PLAN REVIEW BY HAROLD MOSER | | | (561)659-8096 EXT.8390 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-10-23 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2004-10-23 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2004-10-23 |
Time |
14:49 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2003-10-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-25 |
Time |
05:53 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2003-10-25 |
Time |
05:53 |
Sent To |
M |
|
| Notes |
| 2003-10-25 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | | | | 1) ONE SET OF PLANS SUBMITTED FOR RE- | | | STAMP, BUT NUMERIOUS CHANGES ARE NOTED. | | | REVISIONS REQUIRE 2 SETS OF SIGNED AND | | | SEALED PLANSSECTION 104.2.1 | | | FAC 61G1-16.004 - FS 481.221. | | | | | | 2) IT APPEARS THAT A PLUMBING REVISION | | | WAS APPROVED ON 8-4-3 BUT THAT REVISION | | | WAS PICKED UP ON 8-14-3 BECAUSE OTHER | | | TRADES DENIED THEIR PART OF THE REVISION | | | REVISION WAS NEVER RETURNED WITH THE | | | REVISION SUBMITTED 9-24-3 SO NO COPY OF | | | THE PLUMBING REVISION IS ON FILE WITH | | | THE CITY OF WPB. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-20 |
Time |
06:28 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-08-04 |
Time |
12:46 |
Sent To |
M |
|
| Notes |
| 2003-08-04 00:00:00 | REVISION OKCHANGED LOCATION OF TUB | | | CHANGED SAUNA TO SHOWER - CHANGED LOCAT- | | | ION OF LAV - THIRD FLOOR |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-10-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-31 |
Time |
11:57 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2002-10-31 |
Time |
17:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
8 |
Status |
N |
Date |
2004-11-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-28 |
Time |
07:04 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
2003-11-05 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2003-11-05 00:00:00 | RESTAMP DENIED | | | | | | 1) PLANS ARE REQUIRED TO BE SIGNED, | | | SEALED AND DATED BY THE ARCHITECT. | | | | | | 2) SHEET A3 DOES NOT SPECIFY THE CORRECT | | | UL NUMBER FOR THE ONE HOUR STEEL COLUMN | | | ASSEMBLY. | | | | | | 3) TWO OF THE DETAILS ON S5 ARE NUMBERED | | | INCORRECTLY. | | | | | | IN ORDER TO RESTAMP PLANS THEY MUST | | | MATCH THE APPROVED PLANS ON FILE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
7 |
Status |
P |
Date |
2003-11-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2003-11-05 |
Time |
14:14 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2003-11-05 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2003-11-05 00:00:00 | REVISIONS TO SHEETS A1 THROUGH A6 AND | | | S1 THROUGH S5 ARE OK. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
6 |
Status |
F |
Date |
2003-10-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-30 |
Time |
14:54 |
Rev Time |
2.50 |
| Received By |
rmcdouga |
Date |
2003-10-01 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2003-10-01 00:00:00 | REVISION DENIED | | | | | | 1) ON SHEET S3 DETAILS 1 AND 2 HAVE BEEN | | | ADDED, BUT ARE NOT CLOUDED. THE TYPICAL | | | CONNECTOR DETAIL HAS BEEN REMOVED. | | | | | | 2) ON S5 THE ADDED DETAILS AND ELEVATION | | | CHANGE ARE NOT CLOUDED. DETAIL TAGS FOR | | | 1 AND 2 ON S5 ARE USED TWICE. PLEASE | | | CORRECT TO AVOID CONFUSION. | | | | | | 3) THE LOCATIONS FOR BALCONY SECTIONS 1 | | | AND 2 ON S3 ARE NOT INDICATED ON THE | | | FLOOR PLANS. THEY ARE NOT CLOUDED. | | | | | | 4) A REVISED SHEET S2 FOR THE ROOF AND | | | 3RD FLOOR PLAN WAS NOT SUBMITTED. | | | | | | 5) A REVISED SHEET A5 WITH THE NEW | | | ELEVATIONS SHOULD BE SUBMITTED. | | | | | | 6) REVISED SHEET A3 SPECIFIES UL DESIGN | | | X637 FOR THE STEEL COLUMNS. THIS DESIGN | | | IS FOR ROUND PIPE COLUMNS. THE PLANS | | | SPECIFY TUBE COLUMNS. PLEASE SPECIFY AN | | | APPROPRIATE UL SYSTEM TO ACHIEVE THE ONE | | | HOUR FIRE RATING. | | | | | | 7) SUBMIT PRODUCT APPROVALS FOR THE | | | ROOFING MATERIALS. ROOFING WAS NOT PART | | | OF THE ORIGINAL PERMIT, BUT WAS ADDED | | | WHEN CONTRACTOR WAS CHANGED. | | | | | | 8) THE REVISED ENERGY CALCULATIONS ARE | | | REQUIRED TO BE SIGNED AND DATED BY THE | | | OWNER OR HIS AGENT. | | | | | | IF YOU HAVE QUESTIONS, PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
5 |
Status |
F |
Date |
2003-07-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2003-07-28 |
Time |
13:55 |
Rev Time |
4.00 |
| Received By |
rmcdouga |
Date |
2003-07-28 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2003-07-28 00:00:00 | REVISION DENIED BY BUILDING | | | | | | 1) SHEET A2 SPECIFIES 10-3/4" STAIR | | | TREADS AND SECTION A ON A6 SPECIFIES | | | 10-1/2" TREADS. PLEASE CORRECT. MUST | | | COMPLY WITH FBC 1007.3(1), THE SUM OF | | | TWO RISERS AND A TREAD EXCLUSIVE OF THE | | | NOSING SHALL BE NOT LESS THAN 24" NOR | | | MORE THAN 25". | | | | | | 2) SUBMIT REVISED ENERGY CALCULATIONS | | | WHICH INCLUDE THE ADDITIONAL AREA AND | | | GLAZED AREA. | | | | | | 3) SHEET A3 APPEARS TO HAVE A TYPO AT | | | THE DUMD WAITER. THE PLAN HAS DUMP WATER | | | PLEASE CORRECT. | | | | | | 4) THE OPENINGS IN THE NORTH WALL OF THE | | | STAIRWELL THAT IS 17'-3" FROM THE | | | PROPERTY LINE EXCEEDS 40% OF WALL AREA | | | ALLOWED AS OPENINGS BY TABLE 600. PLEASE | | | CORRECT. | | | | | | 5) SPECIFY THE HEIGHT, ATTACHMENTS, AND | | | COMPLIANCE WITH FBC 2405.5 FOR THE GLASS | | | GUARDRAIL AT THE THIRD FLOOR BALCONY ON | | | THE WEST ELEVATION. SUBMIT CALCULATIONS | | | AND SHOP DRAWINGS AT THIS TIME OR APPLY | | | UNDER SEPARATE PERMIT. | | | | | | 6) THE EXTERIOR DOOR TO THE PANTRY DOES | | | NOT HAVE AN ID TAG ON SHEET A2. | | | | | | 7) THE NEW EXTERIOR DOOR TO THE PANTRY | | | IS NOT CLOUDED ON S1. | | | | | | 8) THE INTERNAL PRESSURE COEFFICIENT IS | | | NOT INDICATED AS + OR - ON S3. PLEASE | | | CORRECT. | | | | | | 9)CORRECT THE FONT ON TYPICAL SC1 DETAIL | | | ON S4, IT IS DIFFICULT TO READ. | | | | | | 10) THE ROOF ELEVATIONS ON A5 AND S5 DO | | | NOT CORRESPOND. PLEASE CORRECT. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2003-03-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2003-03-14 |
Time |
10:38 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2003-03-14 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2003-03-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2003-03-10 |
Time |
08:47 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
2003-03-10 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2003-03-10 00:00:00 | BUILDING DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) SPECIFY THE LOCATIONS AND MATERIALS | | | USED FOR DRAFTSTOPPING THE FLOOR/CEILING | | | ASSEMBLIES PER FBC 2305.2.2. SINGLE | | | FAMILY DWELLINGS. IN FLOOR/CEILING | | | ASSEMBLIES SEPARATING USEABLE SPACES | | | INTO TWO OR MORE APPROXIMATE AREAS WITH | | | NO GREATER THAN 500 SQ FT. DRAFTSTOPPING | | | SHALL BE PROVIDED PARALLEL TO THE MAIN | | | FRAMING MEMBERS. | | | | | | 3) THE NEW SHEETS OF DRAWINGS DO NOT | | | HAVE THE EMBOSSED SEAL OF THE DESIGNER | | | OF RECORD. | | | | | | 4) THE TABLE OF DESIGN PRESSURES ON A6 | | | DOES NOT CORRESPOND WITH THE REST OF THE | | | PLANS FOR OPENING MARKS, PRESSURES, ETC. | | | NOTE: THE CITY OF WPB IS LOCATED IN A | | | 140 MPH WIND ZONE. | | | | | | 5)PROVIDE (2) CURRENT AND COMPLETE | | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | | APPROVALS FOR FIXED GLASS WINDOWS LARGER | | | THAN 50 SQ FT. THIS IS THE MAXIMUM SIZE | | | COVERED BY THE PRODUCT APPROVAL THAT WAS | | | SUBMITTED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2003-01-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-01-30 |
Time |
08:05 |
Rev Time |
5.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-01-29 00:00:00 | BUILDING DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3)FL. BLD CODE 1606.1.7 THE FOLLOWING | | | INFORMATION RELATED TO WIND SHALL BE | | | SHOWN ON THE CONSTRUCTION DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | THIS INFORMATION IS REQUIRED TO BE ON | | | THE SIGNED AND SEALED CONSTRUTION | | | DRAWINGS. A PAPER STAPLED TO THE | | | DRAWINGS IS NOT ACCEPTABLE. | | | | | | 4) SPECIFY THE LOCATIONS AND MATERIALS | | | USED FOR DRAFTSTOPPING THE FLOOR/CEILING | | | ASSEMBLIES PER FBC 2305.2.2. | | | | | | 5) THE STRUCTURE IS LOCATED IN AN "A5" | | | FLOOD ZONE, AN ELEVATION CERTIFICATE | | | WILL BE REQUIRED. INDICATE THE PROPOSED | | | GROUND FLOOR FINISH ELEVATION BASED ON | | | N.G.V.D., NOT MEAN SEA LEVEL. NOTE: THE | | | CITY CODE REQUIRES THE LOWEST FLOOR TO | | | BE A MINIMUM OF SIX INCHES ABOVE BASE | | | FLOOD ELEVATION. | | | | | | 6) FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | PROVIDE A SOIL TEST REPORT FROM A | | | SOIL ENGINEER. PROVIDE SUBSURFACE SOIL | | | INVESTIGATION COMPLETE WITH SOIL BORINGS | | | AND RECOMMENDATIONS. | | | | | | 7) STAIRS DO NOT COMPLY WITH FBC 1007.3 | | | SEE STAIR SECTION A ON A6, WHICH THE | | | SUM OF TWO RISERS AND A TREAD (EXCLUSIVE | | | OF THE NOSING) IS 23.75". INDICATE THE | | | DIMENSIONS OF THE HANDRAIL ON THE PLANS. | | | SEE FBC 1007.5.3. | | | | | | 8) CANOPY WILL REQUIRE A SEPARATE PERMIT | | | AS INDICATED ON THE PLANS. | | | | | | 9) BALCONY GUARDRAILS WILL REQUIRE A | | | SEPERATE PERMIT AS INDICATED ON THE | | | PLANS. | | | | | | 10) INDICATE ON THE PLANS THAT THE WIRE | | | MESH IN THE SLAB WILL BE SUPPORTED BY | | | APPROVED MATERIALS OR SUPPORTS AT | | | SPACINGS NOT TO EXCEED THREE FEET. SEE | | | FBC 1909.3. | | | | | | 11) SPECIFY THE CONNECTORS AND UPLIFTS | | | FOR THE GIRDER TRUSSES INDICATED ON THE | | | ROOF PLAN. | | | | | | 12) SPECIFY HOW THE REQUIRED ONE HOUR | | | FIRE PROTECTION WILL BE PROVIDED FOR THE | | | STEEL COLUMNS. | | | | | | 13) SHEET S2 SHOWS A 4" COLUMN ON THE | | | THIRD FLOOR BETWEEN TWO SLIDING GLASS | | | DOORS WITH A WOOD GIRDER TRUSS ABOVE AND | | | BELOW. PROVIDE DETAILS INDICATING THE | | | ATTACHMENT AT THE BASE AND CAP, COLUMN | | | TYPE, FIRE PROTECTION, ETC. | | | | | | 14) PROVIDE A COVER SHEET FOR THE SHEAR | | | WALL CALCULATIONS. PROVIDE THE TITLE | | | BLOCK FOR THE ENGINEER (AND PHONE #), | | | THE DESIGN CRITERIA THE CALCULATIONS ARE | | | BASED ON, THE ADDRESS OF THE JOB, THE | | | CONCLUSIONS THAT WERE REACHED. | | | | | | 15) PROVIDE (2) CURRENT AND COMPLETE | | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | | APPROVALS FOR: | | | - SLIDING GLASS DOORS WIDER THAN 8 FEET | | | - SINGLE HUNG WINDOWS | | | - FIXED GLASS WINDOWS WHICH INCLUDE | | | RECTANGULAR SHAPES UP TO 58 SQ.FT. | | | | | | 16) THE NOTE ON A6 STATES THAT | | | HURRICANE SHUTTERS ARE REQUIRED, HOWEVER | | | NO STORM PANEL INFORMATION WAS SUBMITTED | | | THE PRODUCT APPROVALS SUBMITTED ARE FOR | | | IMPACT RESISTANT OR NON-IMPACT RESISTANT | | | GLASS. PLEASE CLARIFY. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2002-11-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-01-21 |
Time |
09:59 |
Rev Time |
6.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-11-26 00:00:00 | BUILDING DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3)FL. BLD CODE 1606.1.7 THE FOLLOWING | | | INFORMATION RELATED TO WIND SHALL BE | | | SHOWN ON THE CONSTRUCTION DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | | | | 4) THREE STORY R-3 TYPE V STRUCTURE IS | | | REQUIRED TO BE FIRE SPRINKLED OR BE ONE | | | HOUR FIRE PROTECTED. SEE FBC TABLES 500 | | | AND 600. | | | | | | 5) SPECIFY LOCATIONS AND MATERIALS USED | | | FOR DRAFTSTOPPING AT THE FLOOR/CEILING | | | ASSEMBLIES. SEE FBC 2305.2.2 | | | | | | 6) SPECIFY FIREBLOCKING AS REQUIRED IN | | | CONCEALED SPACES. SEE FBC 705.3.1 AND | | | 2305.1. | | | | | | 7) REVISE NOTES ON SHEET A1 UNDER | | | SECURITY & FORCED ENTRY PREVATION THAT | | | REFERENCE THE SFBC. THE CURRENT CODE IS | | | THE FLORIDA BUILDING CODE. | | | | | | 8) THE STRUCTURE IS LOCATED IN AN "A5" | | | FLOOD ZONE AN ELEVATION CERTIFICATE WILL | | | BE REQUIRED. INDICATE THE PROPOSED | | | FINISHED FLOOR ELEVATION. THE MINIMUM | | | ELEVATION IS 7.5 FEET. | | | | | | 9) FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | PROVIDE SOIL TEST REOPRT FROM SOILS | | | ENGINEER. SOIL MUST HAVE A BEARING | | | CAPACITY OF 3000 PSF PER PLANS. | | | | | | 10)FL BLD CODE 2405.2 HAZARDOUS LOCATION | | | SAFETY GLASS IS REQUIRED WITHIN THREE | | | FEET HORIZONTALLY OF A TUB OR SHOWER. | | | | | | 11) PROVIDE AT LEAST ONE BATHROOM ON THE | | | GROUND FLOOR WITH A DOOR THAT HAS A 29" | | | CLEAR OPENING. SEE FBC 11-11. MUST BE | | | FULL BATH, UNLESS ONLY A HALF BATH IS | | | PROVIDE AT GRADE LEVEL. | | | | | | 12) PROVIDE DETAILS OF STAIRS. SHOW | | | COMPLIANCE WITH FBC 1007.3 EXCEPTION (1) | | | WHICH REQUIRES THE SUM OF 2 RISERS AND A | | | TREAD (EXCLUSIVE OF THE NOSING) TO BE | | | NOT LESS THAN 24" NOR MORE THAN 25". | | | SPECIFY HANDRAILS AS REQUIRED BY FBC | | | 1007.5 AND INDICATE HANDRAIL DIMENSIONS | | | THAT COMPLY WITH 1007.5.3. | | | | | | 13)1007.8.1 WINDERS SHALL HAVE A | | | MINIMUM TREAD DEPTH OF 6" AT THE NARROW- | | | EST EDGE & SHALL HAVE A MINIMUM TREAD | | | DEPTH OF 11" AT A POINT 12" FROM THE | | | NARROW EDGE. WINDERS SHALL BE PERMITTED | | | TO BE USED AS A COMPONENT IN MEANS OF | | | EGRESS WITHIN A DWELLING UNIT. | | | | | | 14) FBC 2305.1.4 REQUIRES FIREBLOCKING | | | AT CONCEALED SPACES BETWEEN STAIR | | | STRINGERS AT THE TOP AND BOTTOM OF RUNS. | | | INDICATE THE LOCATIONS AND MATERIALS TO | | | BE USED. | | | | | | 15) ON SHEET A2 THE STAIR INFORMATION | | | GIVEN FOR THE GROUND FLOOR AND SECOND | | | FLOOR APPEARS TO BE REVERSED. PLEASE | | | CORRECT. | | | | | | 16) PROVIDE STRUCTURAL DETAILS FOR THE | | | ALUMINUM CANOPY OR APPLY UNDER SEPARATE | | | PERMIT. INDICATE DIMENSIONS, ATTACHMENT | | | DETAILS, FASTENERS, ENGINEERING, | | | WINDLOADS, ETC. | | | | | | 17)2001 FL BLD CODE, 1005.4: | | | PROVIDE EMERGENCY EGRESS WINDOWS IN | | | SLEEPING ROOMS WITH A MINIMUM NET CLEAR | | | OPENING HEIGHT OF 24" AND NET CLEAR | | | OPENING WIDTH OF 20" AND A NET CLEAR | | | OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR | | | OPENINGS ARE PERMITTED TO HAVE A NET | | | CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGHT | | | SHALL NOT BE MORE THAN 44 " ABOVE THE | | | FINISH FLOOR. WINDOWS IN BEDROOM 1 DOES | | | NOT COMPLY WITH NET CLEAR OPENING HEIGHT | | | | | | 18) PROVIDE MANUFACTURER'S SPECS. AND | | | LISTING INFORMATION FOR THE PRE-FAB FIRE | | | PLACE. | | | | | | 19) PROVIDE STRUCTURAL DETAILS AND | | | ENGINEERING FOR THE GLASS AND ALUMINUM | | | BALCONY GUARDRAILS. INDICATE ATTACHMENTS | | | AT WALLS AND FLOOR, FASTENERS, ETC. | | | | | | 20) GLASS USED FOR GUARDRAILS SHALL | | | COMPLY WITH FBC 2405.5. | | | | | | 21) GUTTERS AND LEADERS SHALL BE SIZED | | | AND DISCHARGED IN ACCORDANCE WITH FBC | | | PLUMBING CODE PER 1503.4.3. | | | | | | 22) 1503.4.4 PROTECTION AGAINST DECAY & | | | TERMITES. CONDENSATE LINES & ROOF DOWN | | | SPOUTS SHALL DISCHARGE AT LEAST 1 FT. | | | AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EX- | | | TENSIONS, OR SPLASH BLOCKS. | | | | | | 23) SPECIFY TERMITE PROTECTION PER FBC | | | 1816.1. | | | | | | 24) FL BLDG 1909.3 (EXEPTION# 2) | | | CONCRETE SLABS ON GRADE CONTAINING 6X6/ | | | W1.4XW1.4 WELDED WIRE REINFORCEMENT | | | FABRIC LOCATED IN THE MIDDLE TO THE | | | UPPER 1/3RD OF THE SLAB SHALL BE SUP- | | | PORTED BY APPROVED MATERIALS OR SUPPORTS | | | AT SPACING NOT TO EXCEED 3 FT OR IN | | | ACCORDANCE WITH MANUFACTURER'S SPEC. | | | SPECIFY ON PLANS. | | | | | | 25) 1707.4.4.2 WHERE BUCK THICKNESS IS | | | LESS THAN 1-1/2" WINDOW AND DOOR SHALL | | | BE ANCHORED THROUGH THE BUCK DIRECTLY TO | | | THE SUBSTRATE. REVISE BUCK DETAILS. | | | | | | 26) PROVIDE HURRICANE ANCHOR SCHEDULE & | | | INDICATE THE LOADS TO BE RESISTED. | | | | | | 27) INDICATE CONNECTIONS FOR WOOD | | | GIRDERS AT WALLS, COLUMNS, ETC. | | | | | | 28) PROVIDE STRUCTURAL DETAIL FOR | | | PARAPET WALLS. | | | | | | 29) PROVIDE STRUCTURAL DETAILS FOR THE | | | CONCRETE BALCONIES. INDICATE SIZES, | | | SPACING OF STEEL REINFORCEMENT, ETC. | | | | | | 30) THE FOOTING AND COLUMN SCHEDULES DO | | | NOT CORRESPOND WITH THE I.D. TAGS GIVEN | | | ON THE PLANS. | | | | | | 31) PROVIDE DETAILS OF THE STEEL COLUMNS | | | INDICATE ATTACHMENTS AT TOP AND BOTTOM | | | OF COLUMNS, FASTNERS ETC. | | | | | | 32) SPECIFY THE TIE BEAMS SIZE, STEEL | | | REINFORCEMENT, ETC. AT EACH FLOOR. | | | | | | 34) PROVIDE A DETAIL INDICATING THE | | | FRAMING THAT WILL BE USED TO SUPPORT THE | | | FLOOR AND CARRY THE CEILING AT THE WALLS | | | THAT PARALLEL THE FLOOR/CEILING JOISTS. | | | | | | 35) SPECIFY THE EMBEDDMENT DEPTH OF THE | | | WEDGE ANCHORS AT THE 2X8 LEDGER AT THE | | | WALL SECTION ON A5. | | | | | | 36) REVISE GENERAL NOTE A ON 5.3 TO | | | REFERENCE THE FBC. | | | | | | 37) SHEET A3 SHOWS A WOOD DECK OVER A | | | CONCRETE SLAB AND S2 SHOWS WOOD TRUSSES | | | IN THE SAME AREA. PLEASE CLARIFY. | | | INDICATE HOW THIS AREA WILL BE MADE | | | WATER TIGHT, HOW DECK WILL BE FASTENED | | | TO CONCRETE, ETC. | | | | | | 38) THE SQUARE FEET OF CONDITION AREA | | | IS DIFFERENT FROM THE A/C AREA LISTED ON | | | THE PLANS. PLEASE CLARIFY. | | | | | | 39) SPECIFY THE AMOUNT OF ROOF SLOPE ON | | | THE PLANS. SEE FBC 1508.3.1 FOR REQUIRED | | | MINIMUM FOR BUILT UP ROOFING. | | | | | | 40)REVIEW THE EAST WALL OF THE STRUCTURE | | | FOR SHEAR WALL REQUIREMENTS AND PROVIDE | | | CALCULATIONS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
REV |
REVISIONS |
| Rev No |
2 |
Status |
P |
Date |
2004-11-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-11-10 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-11-10 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2004-11-10 00:00:00 | REVISIONS TO SHEETS A2 AND A3 ARE OK |
|
|
| Review Stop |
REV |
REVISIONS |
| Rev No |
1 |
Status |
F |
Date |
2004-11-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-11-01 |
Time |
07:34 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
2004-11-01 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2004-11-01 00:00:00 | DENIED | | | | | | 1) SHEETS A2 AND A3 OF THE REVISED | | | PLANS | | | HAVE CHANGES THAT ARE NOT CLOUDED OR | | | NUMBERED. | | | | | | 2) ON A2 THE MASTER BATH TUB SHAPE IS | | | CHANGED AND ADDITIONAL LAVATORY IS | | | SHOWN. | | | | | | 3) ON A3 THE THIRD FLOOR LAUNDRY HAS | | | BEEN CHANGED TO A HALF BATH. THE NOTE | | | FOR W/D STACK IS STILL ON THE PLAN. | | | | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2003-10-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2003-10-01 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-10-01 00:00:00 | REVISION OK PER M.MCLEAN ON 10-1-03 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2003-07-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-07-30 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-01-30 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-01-30 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2002-11-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-06 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2002-11-26 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2002-10-21 00:00:00 | 1.SUBMIT A CLEAR SITE PLAN SHOWING | | | THE CONSTRUCTION BEING BUILT NOW. | | | 2.SUBMIT A STRUCTURE SHEET SHOWING | | | THE HEIGHT AT 30' INSTEAD OF 32' | | | 3.NO GRAVEL DRIVEWAY IS ALLOWED IN | | | THE PRESENT ZONING CODE | | | 4.THE FRONT YARD MUST MAINTAIN 1000 | | | SQ.FT OR 75% LANDSCAPED |
|
|