| Plan Review Stops For Permit 02100790 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-12-16 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-12-16 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-12-16 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-10-31 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-10-31 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-10-30 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2002-10-31 00:00:00 | PROVIDE A DESCRIPTION OF THE | | | PROCESSES AND / OR THE NATURE AND | | | CHARACTERISTICS OF THE COMMODITIES TO | | | BE STORED ON THE PREMISES.SEE FBC 104. | | | 2 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-12-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-05 |
Time |
06:54 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2002-12-05 |
Time |
06:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-10-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-10-15 |
Time |
15:33 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2002-10-15 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2002-12-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-12-05 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-12-05 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2002-11-01 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-11-01 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-11-01 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2002-11-01 00:00:00 | 1) PROVIDE ILLUMINATED EXIT SIGN NEAR | | | DOOR FROM ROOM 008 AND THE WAREHOUSE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-12-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-04 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-18 |
Time |
17:34 |
Sent To |
|
|
| Notes |
| 2002-12-04 00:00:00 | COMM BOARD # 49./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-12-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-12-05 |
Time |
10:54 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2002-12-05 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2002-12-05 00:00:00 | MECHANICAL PERMIT 02100792 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
I |
Date |
2002-11-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-11-05 |
Time |
08:57 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-11-05 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2002-11-05 00:00:00 | HVAC PLANS ARE CODE COMPLIANT.PLEASE | | | PROVIDE INFORMATION AS TO WHAT WILL BE | | | STORED IN THE WAREHOUSE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-01-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-13 |
Time |
18:40 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-01-13 |
Time |
18:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2002-12-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-12-13 |
Time |
12:55 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2002-12-13 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2002-12-13 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) PREVIOUS COMMENT REPLY ACKNOWLEDGED, | | | BUT PER TABLE 403.1 EITHER A DRINKING | | | FOUNTAIN OR A WATER COOLER IS REQUIRED. | | | "WHERE WATER IS SERVED IN RESTAURANTS OR | | | WHERE BOTTLED WATER COOLERS ARE PROVIDED | | | IN OTHER OCCUPANCIES, DRINKING FOUNTAINS | | | SHALL NOT BE REQUIRED. SEC. 410.1 | | | MANUF. INFORMATION REQUIRED - WATER | | | COOLER SHALL BE ARI-1010 COMPLIANT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-11-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-11-02 |
Time |
17:34 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2002-11-02 |
Time |
17:34 |
Sent To |
|
|
| Notes |
| 2002-11-02 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) TABLE 403.1 REQUIRED A DRINKING FOUN- | | | TAIN FOR MINIMUM FACILITIES. ALSO SEE | | | SECTION 410.1 - ARI-1010 COMPLIANCE IF | | | WATER COOLER IS USED. | | | 2) SHT P-2 PLUMBING SPECIFICATIONS #7, | | | AIR CHAMBERS ARE NOT APPROVED. SEE SECT. | | | 604.9. IF WATER HAMMER ARRESTORS ARE | | | USED, LOCATE NEAR FIXTURE PER PDI-WH 201 | | | NOT AT TOP OF DROP IN CEILING. | | | 3) PLEASE INDICATE MATERIAL BEING WARE- | | | HOUSED. REVIEW COMMENTS MAY BE ADDED | | | ACCORDING TO INFORMATION RECIEVED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|