| Plan Review Stops For Permit 02100713 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
P |
Date |
2004-03-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-03 |
Time |
07:41 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-03-03 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2004-03-03 00:00:00 | TRUSS DRAWINGS, SOUTHERN TRUSS, | | | PREPARED BY JOHN C. WEBER, PE 1/13 AND | | | 2/9/04 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
F |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-01 |
Time |
12:23 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-02-05 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2004-02-05 00:00:00 | ****CORRECTIONS***** | | | TRUSS DRAWINGS PREPARED BY | | | JOHN CLARK WEBER, PE 2/2/04 FOR | | | SOUTHERN TRUSS | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)SEE PREVIOUS LISTS AND FAC61G15 IN | | | REGARDS TO INFORMATION REQUIRED TO BE | | | ON ALL DOCUMENTS FILED FOR PUBLIC | | | RECORD AND PROPER SUBMITTAL OF TRUSS | | | ENGINEERING.THE HIGHLIGHTED ADDRESS | | | ON THE CALCULATIONS IS NOT THE | | | ADDRESS OF THE ENGINEER, AND THE | | | TRUSS COMPANY DOES NOT HAVE AN | | | ENGINEERING AUTHORIZATION NUMBER.THE | | | FBPE CONSIDERS THE FACT THAT THE TRUSS | | | DRAWINGS HAVE FAILED REVIEW THREE TIMES | | | AN "ISSUE OF CONCERN" AND HAVE REQUESTED | | | THAT A COMPLAINT BE FILED AGAINST THE | | | ENGINEER IF THE MATTER IS NOT RESOLVED | | | IN THE NEXT SUBMITTAL. | | | | | | IF YOU HAVE FURTHER INFORMATION IN | | | REGARDS TO WHY THE ENGINEER WOULD | | | CONSIDER THE TRUSS COMPANY NAME AND | | | ADDRESS HIS TITLE BLOCK, PLEASE | | | CONTACT ME. | | | | | | CC:DON NEELY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
P |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-02-05 |
Time |
07:58 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-02-05 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2004-02-05 00:00:00 | HAND/GUARDRAIL SHOPS & CALCS | | | PREPARED BY THOMAS KELAHER, PE 1/22/04 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
F |
Date |
2004-01-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-03 |
Time |
16:40 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-01-26 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2004-01-26 00:00:00 | *****CORRECTIONS***** | | | TRUSS DRAWINGS PREPARED BY SOUTHERN | | | TRUSS/JOHN C. WEBER, PE DATED 1/13/04 | | | | | | 1.) SEE PREVIOUS LIST, ATTACHED.THE | | | DRAWINGS ARE NOW SIGNED AND SEALED BUT | | | THERE IS NO TITLE BLOCK FOR THE | | | ENGINEER.SEE ATTACHED FAC61G15-31.003. | | | I HAVE HIGHLIGHTED THE PERTINENT | | | INFORMATION. | | | | | | 2.) THE LETTER IN REGARDS TO GABLE END | | | BRACING IS FOR THE PORTOFINO PROJECT. | | | THIS PROJECT IS CORNERSTONE/BEAR LAKES. | | | | | | 3.) SEE ATTACHED NOTICE IN REGARDS TO | | | FS553.80(2)(B). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-23 |
Time |
08:59 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-01-16 |
Time |
07:06 |
Sent To |
|
|
| Notes |
| 2004-01-16 00:00:00 | RESHORE PLAN, BLDG TYPE V (#5,8,9,12) | | | PREPARED BY CALVIN FOONG, PE DATED | | | 8/12/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
F |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-01-14 |
Time |
08:33 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-01-14 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2004-01-14 00:00:00 | *****CORRECTIONS***** | | | | | | HANDRAIL SHOP DRAWING & CALCULATIONS | | | PREPARED BY THOMAS KELAHER, PE 11/4/03 | | | | | | 1.)THE GUARDRAIL DESIGN DOES NOT | | | COMPLY WITH FBC1608.2.2. | | | | | | 2.)SHEET AR-SW-1, TYPICAL SECTION | | | THROUGH STAIR RAIL IS NOT LEGIBLE. | | | | | | 3.)STAIR RAIL IS TO COMPLY WITH FBC | | | 1015.3, EXCEPTION 1. | | | | | | CC:DON NEELY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2004-01-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-01-10 |
Time |
20:14 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-01-10 |
Time |
20:14 |
Sent To |
|
|
| Notes |
| 2004-01-10 00:00:00 | *****CORRECTIONS***** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEE ATTACHED FAC61G15-31.003, | | | DESIGN OF STRUCTURES UTILIZING | | | PREFABRICATED WOOD TRUSSES.THE | | | SEALED SHEETS SUBMITTED ARE NOT | | | SIGNED BY THE ENGINEER (IT IS A | | | PHOTOCOPY OF A SIGNATURE), AND THE | | | PAGES LACK A TITLE BLOCK. | | | | | | THIS SAME CORRECTION WAS ALREADY MADE | | | ON TRUSS DRAWINGS WHICH WERE SUBMITTED | | | ON ANOTHER BUILDING TYPE.THIS SAME | | | CORRECTION WILL APPLY TO ALL TRUSS | | | DRAWINGS SUBMITTED NOT IN ACCORDANCE | | | WITH FAC61G15-31.003. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2004-01-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-09 |
Time |
11:15 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-01-02 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2004-01-02 00:00:00 | REVISION - SHUTTER STORAGE UNDER STAIRS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2003-12-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2003-12-24 |
Time |
09:08 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2003-12-24 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2003-12-24 00:00:00 | FIRESTOP DETAIL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2003-12-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-19 |
Time |
14:36 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2003-12-17 |
Time |
17:43 |
Sent To |
|
|
| Notes |
| 2003-12-17 00:00:00 | *****CORRECTIONS***** | | | FIRESTOP DETAIL | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE DETAIL SUBMITTED IS TO BE | | | SIGNED AND SEALED BY THE DESIGNER OF | | | RECORD.INCLUDE A TITLE BLOCK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2003-12-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-16 |
Time |
12:35 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2003-12-15 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2003-12-15 00:00:00 | ****CORRECTIONS***** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)SEE ATTACHED FAC61G15-31.003 | | | (DESIGN OF STRUCTURES UTILIZING | | | PREFABRICATED WOOD TRUSSES) AND | | | FAC61G15-23.002 REGARDING SEALS.SOME | | | SHEETS DO NOT HAVE A TITLE BLOCK, SOME | | | ARE NOT SEALED, OTHERS ARE SEALED BUT | | | DO NOT HAVE A WET SIGNATURE (PHOTOCOPY | | | OF A SIGNATURE IS NOT ACCEPTABLE). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-05-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-10 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-05-13 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2003-05-13 00:00:00 | OK PER BILL STAPLES | | | | | | SEE CBAA MINUTES, APRIL 17, 2003 CASE | | | NO. 1230 AND JANUARY 8, 2003 CASE NO. | | | 1224. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-04-14 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-04-14 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-04-14 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2003-04-14 00:00:00 | THIRD PAID PLAN REVIEW NOT A PERMIT | | | APPLICATION. | | | | | | SAME COMMENTS AS #02100705 NO CHANGES | | | FROM 2/27/03. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-04-14 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-11-12 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-11-08 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2002-11-12 00:00:00 | PAID PLAN REVIEW ONLY, NOT A PERMIT | | | APPLICATION. | | | | | | THE MINIMUM CONSTRUCTION TYPE IS TYPE | | | VI, ONE HOUR PROTECTED. | | | | | | THE PERMIT PLANS MUST HAVE A FIRE | | | SPRINKLER SYSTEM AS REQUIRED BY FBC | | | 903.8 SHOWN ON THE PLANS. | | | | | | TWO INDEPENDENT EXITS ARE REQUIRED FROM | | | THE THIRD FLOOR AND THE STAIRS ARE | | | REQUIRED TO BE ENCLOSED IN FIRE RATED | | | CONSTRUCTION FBC 1006.1, OR COMPLY WITH | | | FBC 1006.2 FOR EXTERIOR STAIRS. | | | | | | SHEET A-T5.2 CALLS FOR ROOF COVERINGS | | | MEETING THE REQUIREMENTS OF FBC 3207. | | | THIS SHOULD BE REVISED TO FBC 1503. | | | PLEASE BE AWARE THAT CITING CODE | | | SECTIONS IS NOT AN ACCEPTIBLE | | | SUBSTITUTE FOR SPECIFIC DESIGN | | | INFORMATION.SEE FBC 104.2.1. | | | | | | SHEET AT 4.2 HAS NOTES FOR ROOF TILE | | | NAILINGS THAT ARE INCONSISTENT WITH THE | | | SEVERAL NOTICE OF ACCEPTANCE REPORTS. | | | | | | SHEET AT4.2 HAS SEVERAL DECLARATIONS FOR | | | THE ATTIC VENTILATION THAT WOULD | | | REQUIRE THE SCREEN VENTS TO HAVE OPEN | | | AREA ON THE ORDER OF 80% WHICH WOULD BE | | | AN UNUSUAL SCREEN. | | | | | | IF PRODUCT APPROVALS FOR THE DOORS, | | | WINDOWS AND ROOF COVERINGS ARE NOT | | | INCLUDED AT THE TIME OF PERMIT | | | APPLICATION, SEPARATE PLANS PERMITS AND | | | FEES WILL BE REQUIRED FOR THAT WORK. | | | | | | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY, THE PERMIT PLANS | | | STAMPED BY THAT OFFICE AND A COPY OF | | | THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. CALL 561-233-5025 FOR MORE | | | INFORMATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
N |
Date |
2003-10-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-06 |
Time |
09:02 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-10-06 |
Time |
09:01 |
Sent To |
B |
|
| Notes |
| 2003-10-06 00:00:00 | FIRE SUBMITTALS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2003-09-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:58 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-09-25 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-09-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-09-25 |
Time |
06:42 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-09-25 |
Time |
06:42 |
Sent To |
|
|
| Notes |
| 2003-09-25 00:00:00 | ROMEX LTR. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-04-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-16 |
Time |
12:33 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-04-11 |
Time |
04:12 |
Sent To |
|
|
| Notes |
| 2003-04-11 00:00:00 | ELECTRICAL PLANS STAMPED, READY TO BE | | | ISSUED. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT8372 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-02-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-20 |
Time |
20:16 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-02-20 |
Time |
20:16 |
Sent To |
|
|
| Notes |
| 2003-02-20 00:00:00 | *************** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE NOTES FROM FIRST | | | REVIEW. NOT ALL NOTES WERE ADDRESSED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESITONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-06 |
Time |
05:48 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2002-11-06 |
Time |
05:44 |
Sent To |
|
|
| Notes |
| 2002-11-06 00:00:00 | *********** UNSAT **************** | | | | | | | | | | | | | | | 1)NOTE: PLEASE NOTE ON PLANS, A DISC | | | MAY BE REQ`D FOR AHU/WATER HEATER UNLESS | | | LOCK OF DEVICE IS APPROVED BY THE CITY | | | OF WEST PALM BEACH. THERE ARE MANY "LOCK | | | OFF " DEVICES THAT ARE NOT ACCEPTABLE. | | | 90-4 | | | | | | 2)NOTE: PLEASE CALRIFY HOW 12KW AT 70% | | | IS = TO 5.6KW? | | | | | | 3)NOTE: PLEASE CLARIFY RECEPTS FOR A/C | | | COND UNITS.210-63 | | | | | | 4)NOTE: PLEASE LIST OR NOTE MAINS AT | | | METER LOCATION ON E-T5.3 | | | | | | 5)NOTE: PLEASE CLARIFY EQUIPMENT GROND- | | | -ING BETWEEN MAIN AND H PANEL. | | | 250-122 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRCIAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-04-15 |
Time |
08:19 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2003-04-15 |
Time |
08:19 |
Sent To |
|
|
| Notes |
| 2003-04-15 00:00:00 | PASSED: | | | 1. SEE PERMIT # 03040786 FOR UNDERGROUND | | | UTILITIES AND SITE WORK. | | | IF ANY QUESTION PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2003-02-18 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-02-18 |
Time |
10:32 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-02-18 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2003-02-18 00:00:00 | FAILED: | | | 1. PLEASE SEE THE PREVIOUS REVIEW | | | COMMENTS DATED 11-06-02. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2002-11-06 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-11-06 |
Time |
15:41 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2002-11-06 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2002-11-06 00:00:00 | FIALED : | | | 1. SEE REVIEW COMMENTS FOR PALN REVIEW # | | | 02100708. | | | IF ANY QUESTIONS PLEASE CONTACR 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2003-12-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-29 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-12-15 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2003-12-15 00:00:00 | SEE NOTES ON PERMIT 02100705 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-05-01 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-05-01 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-05-01 |
Time |
16:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-11-14 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-11-14 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-11-14 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2002-11-14 00:00:00 | 1) BUILDING ADDRESSES REQUIRED ON | | | BUILDINGS. | | | | | | 2) FIRE SPRINKLER DRAWINGS ARE REQUIRED | | | AT TIME OF PERMIT SUBMITTAL. ALL | | | BUILDINGS THREE STORIES OR GREATER ARE | | | REQUIRED TO BE FIRE SPRINKLER PROTECTED | | | PER FS 553.895(2) | | | | | | 3) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | | TO,DURING AND AFTER CONSTRUCTION. | | | | | | 4) WHAT PROVISIONS ARE TO BE MADE WITH | | | REGARDS TO FIRE AND PARAMEDICAL ACCESS | | | THRU THE SECURITY GATES. IF SECURITY | | | GATES ARE ELECTRIC, WHAT PROVISIONS | | | HAVE BEEN IN THE EVENT OF LOSS OF | | | POWER. | | | | | | 5) ALL OPENINGS IN WHICH FIRE RESCUE | | | VEHICLES ARE EXPECTED TO PASS SHALL BE | | | AT LEAST TWENTY FEET IN CLEAR WIDTH. | | | SEPARATE PERMIT REQUIRED. | | | | | | 6) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE ALARM SYSTEM INSTALLATION. | | | | | | 7) ELECTRIC POWERED SMOKE DETECTORS | | | SHALL NOT BE INSTALLED CLOSER THAN | | | THREE FEET FROM AIR CONDITIONER | | | DIFFUSERS. | | | | | | 8) PLEASE PROVIDE A LIFE SAFETY PLAN | | | WITH REGARDS TO EXITING FOR REVIEW. | | | | | | 9) NO EMERGENCY LIGHTING SHOWN OF SIDE | | | EXIT STAIRS. | | | | | | 10) ARE THERE ANY WINDOWS WITHIN 10 FEET | | | OF THE SINGLE EXIT STAIRS. | | | | | | 11) NO PROPANE GRILLS ARE ALLOWED ON | | | EXTERIOR PATIO'S. | | | | | | 12) PLEASE PROVIDE PRESCRIPTIVE CODE | | | REQUIREMENTS FOR ALL HANDRAILS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
30 |
Status |
N |
Date |
2004-03-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-05 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-01 |
Time |
12:23 |
Sent To |
|
|
| Notes |
| 2004-03-01 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
29 |
Status |
N |
Date |
2004-02-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-03 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-03 |
Time |
16:39 |
Sent To |
B |
|
| Notes |
| 2004-02-03 00:00:00 | TO SH DESK/TRUSS DRAWS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
28 |
Status |
N |
Date |
2004-02-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-03 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-03 |
Time |
16:37 |
Sent To |
B |
|
| Notes |
| 2004-02-03 00:00:00 | TO SH DESK/SHUTTERS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
27 |
Status |
N |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-29 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-29 |
Time |
10:23 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
26 |
Status |
N |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-29 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-29 |
Time |
10:10 |
Sent To |
B |
|
| Notes |
| 2004-01-29 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
25 |
Status |
N |
Date |
2004-01-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-23 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-23 |
Time |
08:54 |
Sent To |
B |
|
| Notes |
| 2004-01-23 00:00:00 | TO SH DESK/SUBMITTAL/TRUSS END DETAIL | | | 03042901/03042906/03042909/03012920 | | | | | | | | | | | | | | | | | | | | | | | | | | | TO SH DESK/SUBMITTALS/TRUSS END DETAIL | | | 03042901/03042906/03042909/03042920 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
24 |
Status |
N |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-09 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-09 |
Time |
11:15 |
Sent To |
B |
|
| Notes |
| 2004-01-09 00:00:00 | TO SH DESK/SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
23 |
Status |
N |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-09 |
Time |
31:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-09 |
Time |
11:14 |
Sent To |
B |
|
| Notes |
| 2004-01-09 00:00:00 | TO SH DESK/SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
22 |
Status |
N |
Date |
2004-01-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-07 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-07 |
Time |
14:38 |
Sent To |
B |
|
| Notes |
| 2004-01-07 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2003-12-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-19 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-19 |
Time |
14:43 |
Sent To |
M |
|
| Notes |
| 2003-12-19 00:00:00 | TO PK BOX/EXHAUST FAN DUCT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2003-12-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-19 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-19 |
Time |
14:39 |
Sent To |
M |
|
| Notes |
| 2003-12-19 00:00:00 | TO PK BOX/REFRIG LINE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2003-12-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-19 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-19 |
Time |
14:36 |
Sent To |
B |
|
| Notes |
| 2003-12-19 00:00:00 | TO SH DESK/FIRE STOP METHOD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2003-12-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-16 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-16 |
Time |
12:35 |
Sent To |
B |
|
| Notes |
| 2003-12-16 00:00:00 | TO SH DESK/SUBMITTAL/FIRE STOP METHOD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2003-12-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-10 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-10 |
Time |
16:34 |
Sent To |
B |
|
| Notes |
| 2003-12-10 00:00:00 | TO ST DESK/SUBMITTAL/HANDRAIL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2003-12-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-01 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-01 |
Time |
16:01 |
Sent To |
B |
|
| Notes |
| 2003-12-01 00:00:00 | TO ST DESK/SUBMITTAL TRUSS DRAWINGS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2003-11-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-17 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-11-17 |
Time |
10:19 |
Sent To |
M |
|
| Notes |
| 2003-11-25 00:00:00 | TO MECH IN BOX | | 2003-11-17 00:00:00 | TO HP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2003-11-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-06 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-06 |
Time |
10:13 |
Sent To |
B |
|
| Notes |
| 2003-11-06 00:00:00 | TO HP DESK/PROD APPR |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2003-11-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-04 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-04 |
Time |
16:08 |
Sent To |
P |
|
| Notes |
| 2003-11-04 00:00:00 | TO KS DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2003-10-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-17 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-17 |
Time |
16:44 |
Sent To |
M |
|
| Notes |
| 2003-10-17 00:00:00 | TO PK BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-14 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-14 |
Time |
14:39 |
Sent To |
B |
|
| Notes |
| 2003-10-14 00:00:00 | TO HP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2003-10-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-09 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-09 |
Time |
10:44 |
Sent To |
B |
|
| Notes |
| 2003-10-09 00:00:00 | TO HP DESK/SUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2003-10-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-03 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-03 |
Time |
10:15 |
Sent To |
B |
|
| Notes |
| 2003-10-03 00:00:00 | TO HP DESK/SUB PROD APPRVLS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-02 |
Time |
11:58 |
Sent To |
E |
|
| Notes |
| 2003-10-02 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-02 |
Time |
11:23 |
Sent To |
P |
|
| Notes |
| 2003-10-02 00:00:00 | TO KS BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-02 |
Time |
11:21 |
Sent To |
M |
|
| Notes |
| 2003-10-02 00:00:00 | TO PK BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-09-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-16 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-16 |
Time |
12:33 |
Sent To |
E |
|
| Notes |
| 2003-09-16 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-08-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-27 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-27 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2003-08-27 00:00:00 | ON COMM BD #1 - PLANS ON RACK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-05-01 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-01 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-01 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2003-05-01 00:00:00 | COMM BOARD #39.PLANS NEXT TO CONF ROOM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-04-03 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-03 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-03 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2003-04-03 00:00:00 | COMM BOARD #10, PLANS NEXT TO RACK, | | | COVER SHEET GIVEN TO SHIRLEY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-02-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-13 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-13 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2003-02-13 00:00:00 | TO COMM BOARD #49 | | | PLANS ON BOTTOM OF RACK BY CONFERENCE | | | ROOM. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-23 |
Time |
14:45 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2003-12-23 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2003-12-23 00:00:00 | SUBMITTAL DWG/REFRIGERANT SHAFT DETAIL |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2003-11-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-19 |
Time |
14:43 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2003-11-18 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2003-11-18 00:00:00 | PLEASE NOTE PLAN SHEET AC-DT2 IS DENIED. | | | PLAN OMITTED DETAIL OF SHAFT FOR THE | | | REFRIGERATION LINES.AS PER ASHRAE | | | 15-92 SECTION 11.12.3 REFRIGERANT PIPING | | | SHALL NOT BE INSTALLED VERTICALLY | | | THROUGH FLOORS FROM ONE STORY TO ANOTHER | | | EXCEPT AS FOLLOWS: | | | (B) IN APPROVED RIGID, TIGHT AND | | | CONTINUOUS FIRE-RESISTING PIPE DUCT OR | | | SHAFT. ON THE OUTER WALL OF THE BUIDLING | | | (NOT IN AIR SHAFT OR CLOSED COURT). THE | | | SHAFT SHALL BE VENTED TO THE OUTSIDE | | | OR TO THE SPACE SERVED BY THE SYSTEM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2003-10-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-21 |
Time |
11:53 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-10-21 |
Time |
11:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2003-10-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-17 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2003-10-06 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2003-10-06 00:00:00 | DENIED:TYPE V | | | PLAN SHEET AC-C1 INDICATES DRYER EXHAUST | | | DUCT 22" UP WHICH WOULD INDICATE A SUB- | | | DUCT METHOD.PLAN SHEET AC-D2 INDICATES | | | DUCT RUNNING THROUGH THE ROOF.PLEASE | | | CLARIFY WHICH METHOD WILL BE USED.SUB- | | | DUCT METHOD HAS ADDITIONAL REQUIREMENTS | | | THAT WILL NEED TO BE ADDRESSED. | | | | | | PLEASE NOTE, AS PER THE "FAIR HOUSING | | | ACT" ENVIRONMENTAL CONTROLS IN ADDITION | | | TO ELECTRICAL CONTROLS SHALL BE LOCATED | | | AT A HEIGHT ACCESSIBLE AS PER THE "FAIR | | | HOUSING ACT DESIGN MANUAL". | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2003-04-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:21 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2003-04-16 |
Time |
10:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
|
Date |
2003-04-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-04-03 |
Time |
10:20 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-04-03 00:00:00 | AS PER MTG 4-3-03, COMMENTS ADDRESSED - | | | PLANS NEED TO BE STAMPED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-02-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-18 |
Time |
16:28 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-02-18 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2003-02-18 00:00:00 | PROVISO:TYPE V | | | 1. PLAN SHEET AC-D1 GE WASHER/DRYER | | | MODEL SPECIFICATIONS, SPECS INDICATE | | | ELECTRIC & GAS DRYERS, SHOULD GAS DRYERS | | | BE INSTALLED CALCULATIONS FOR COMBUSTION | | | AIR WILL BE REQUIRED. | | | | | | 2. PLAN SHEET AC-D2 DETAIL FOR TOILET | | | EXHAUST,AS PER 2001 FBC (M) 607.4, | | | DUCTS EXTENDING THROUGH MORE THAN ONE | | | FLOOR SHALL BE PROTECTED BY A SHAFT | | | ENCLOSURE HAVING A FIRE RESISTANCE | | | RATING OF 1HR FOR BUILDINGS LESS THAN | | | 4 STORIES & 2HR FOR BUILDINGS GREATER | | | THAN 4 STORIES. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-11-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-11-05 |
Time |
09:34 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2002-11-05 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2002-11-05 00:00:00 | DENIED:TYPE V | | | | | | PLEASE CLARIFY THE FOLLOWING INFORMATION | | | | | | 1.NOTES CONCERNING THE DRYER & TOILET | | | EXHAUST ARE NOT CLEAR.PLAN SHEET | | | A-DT1 SHOWS A 1 HR SHAFT DETAIL FOR | | | THE TOILET & DRYER EXHAUST, PLAN | | | SHEET AC-D1 ON THE EXHAUST DUCT | | | DETAIL SHOWS ONLY A 1 HR FIRE RATED | | | CAULK SEALANT WITHOUT INDICATING THE | | | 1 HR SHAFT. | | | | | | PLEASE PROVIDE A RISER DETAIL | | | SHOWING WHERE THE SHAFT BEGINS & | | | ENDS.REFERENCE PLAN SHEET A-DT1, | | | (SHAFT DETAIL) ON THE MECHANICAL | | | PLAN. | | | | | | 2.PLAN SHEET AC-D1 - NOTE #2, STATES | | | DRYER EXHAUST DISCHARGE ON ROOF | | | SHALL BE SIMILAR TO TOILET EXHAUST | | | DISCHARGE BUT SHALL NOT BE SCREENED. | | | AS PER 2001 FBC(M) 504.4, SHALL | | | TERMINATE ON THE OUTSIDE OF THE | | | BUILDING & SHALL BE EQUIPPED WITH A | | | BACKDRAFT DAMPER. | | | | | | 3.PROVIDE OUTSIDE AIR CALCULATIONS IN | | | ACCORDANCE WITH 2001 FBC(M) 402.2 | | | FOR NATURAL VENTILATION OR TABLE | | | 403.3.PROVIDE CALCULATIONS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
P |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-06 |
Time |
18:45 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-01-06 |
Time |
18:45 |
Sent To |
|
|
| Notes |
| 2004-01-06 00:00:00 | REVISION OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
F |
Date |
2003-10-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-04 |
Time |
16:09 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-10-28 |
Time |
18:28 |
Sent To |
B |
|
| Notes |
| 2003-10-28 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SECTION 606.1(3) ON THE BASE OF EVERY | | | WATER RISER PIPE IN OCCUPANCIES OTHER | | | THAN MULTIPLE FAMILY RESIDENTIAL OCCUP- | | | ANCIES THAT ARE TWO STORES OR LESS IN | | | HEIGHT AND ONE AND TWO FAMILY RESIDENT- | | | IAL OCCUPANCIES, FULL-OPEN VALVES SHALL | | | BE INSTALLED. ACCESS SHALL BE PROVIDED | | | TO ALL REQUIRED FULL-OPEN VALVES. SECT- | | | ION 606.3 | | | | | | 2) THE #530C WATTS THERMAL EXPANSION | | | CONTROL VALVE IS NOT APPROVED FOR MULTI- | | | HEATER USE PER MANUFACTURE REPRESENTA- | | | TIVE. INDICATE HOW THERMAL EXPANSION | | | CONTROL WILL BE ACCOMPLISHED. 607.3.2 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2003-10-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-11 |
Time |
15:34 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-10-11 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2003-10-11 00:00:00 | SUBMITTAL OK - 3M FIRESTOP |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2003-09-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:23 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-09-29 |
Time |
18:13 |
Sent To |
|
|
| Notes |
| 2003-09-29 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHT P-T5.1 REVISION #3 NOT FOUND. | | | PLEASE CLAIRFY, | | | 2) SHT P-T5.2 REVISION #1 NOT FOUND. | | | PLEASE CLAIRFY. | | | 3) SHT P-T5.3 REVISION #1 NOT FOUND. | | | PLEASE CLAIRFY. | | | 4) SHT P-D1 THERMAL EXPANSION CONTROL. | | | SUBMIT MANUF. SPECIFICATION SHEETS ON | | | THERMAL EXPANSION VALVE TO SHOW CAPABIL- | | | ITY OF CONTROLLING EXPANSION FOR ALL 26 | | | UNITS. | | | 5) SHT P-D1 RELIEF VALVE DISCHARGE LINE | | | (P/T) AND EMERGENCY PAN DRAIN LINES | | | SHALL BE 2" UNDERGROUND PER SECTION | | | 710.3 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2003-08-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-06 |
Time |
17:32 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-08-06 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2003-08-06 00:00:00 | REVISION DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT P-T5.1 CLEANOUTS REQUIRED PER SEC | | | 708.3.2 & 708.3.3. ALSO SHOW ON RISER | | | DIAGRAM SHT P-T5.2. | | | 2) SHT P-T5.3 STILL HAS ORIGINAL BLDG. | | | DRAIN RISER DIAGRAM AND WATER RISER | | | DIAGRAMS. REVISION FOR THESE HAS BEEN | | | SUBMITTED ON SHT P-T5.2. THESE REVISIONS | | | SHOULD BE SUBMITTED ON THE ORIG. SHEETS | | | THAT THEY WERE ORIGINALLY APPROVED ON TO | | | AVOID CONFUSION. ALSO ROOF PLAN HAS BEEN | | | DELETED ON SHT P-T5.2. PLEASE CLAIRFY. | | | --- COMMENTS 3) THRU 6) --- SEE COMMENTS | | | ON PERMIT #02100705 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-04-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-14 |
Time |
08:27 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-04-14 |
Time |
08:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-03-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-05 |
Time |
14:02 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-03-05 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2003-03-05 00:00:00 | DENIED | | | | | | SEE COMMENTS FROM REVIEW FOR PERMIT NUM- | | | BER 02100705. (TYPE 1) | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-11-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-11-07 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-11-06 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2002-11-07 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FHA-AMEND 98 DESIGN MANUAL | | | | | | 1) SHTS A-U1 & A-U2, INDICATE ON PLANS | | | SPECIFICATION "A" OR "B" FOR BATHROOMS | | | PER REQUIREMENT 7B PAGE 7.35 DESIGN | | | MANUAL FHA-98 | | | 2) SHT ADT-II BACKING FOR W/C'S AND TUBS | | | TO BE ACCORDING TO REQUIREMENT 6 PAGE | | | 6.9 DESIGN MANUAL FHA-98. | | | 3) SHT ADT-II THE TOP OF LAV FIXTURE RIM | | | IS A MAXIMUM OF 2'10" ABOVE FINISHED | | | FLOOR. PLEASE INDICATED ON BATHROOM DE- | | | TAIL. | | | 4) SHT P-U2 DOMESTIC WATER RISER, LOCATE | | | WATER HAMMER ARRESTOR AT WASH MACHINE | | | NEAR FIXTURE NOT AT TOP OF DROP. | | | 5) SHT P-D1 PLUMBING GENERAL NOTES #6, | | | DIELECTRIC UNIONS NOT APPROVED FOR WATER | | | USAGE. PLEASE DELETE REFERENCE. | | | 6) SHT PD-1 WATER HEATER DETAIL, THE | | | RELIEF VALVE DISCHARGE PIPE SHALL NOT | | | HAVE ANY TRAPPED SECTIONS. SEC 504.7.1 | | | THERMAL EXPANSION CONTROL IS ALSO RE- | | | QUIRED. SECTION 607.3.2. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-30 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2003-04-30 |
Time |
08:20 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-04-30 00:00:00 | "MASTER" | | | REVIEW NOT REQUIRED |
|
|