| Plan Review Stops For Permit 02100712 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2004-02-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-02-04 |
Time |
17:20 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-02-04 |
Time |
17:20 |
Sent To |
|
|
| Notes |
| 2004-02-04 00:00:00 | HAND/GUARDRAIL SHOPS & CALCULATIONS, | | | THOMAS KELAHER, PE 1/22/04 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2004-01-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-03 |
Time |
16:37 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-01-16 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2004-01-16 00:00:00 | RESHORE PLAN PREPARED BY CALVIN FOONG, | | | PE DATED 8/12/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2004-01-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-01-14 |
Time |
10:53 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-01-14 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2004-01-14 00:00:00 | ****CORRECTIONS**** | | | | | | HANDRAIL SHOP DRAWINGS & CALCULATIONS | | | PREPARED BY THOMAS KELAHER, PE 11/4/03 | | | | | | 1.)THE GUARDRAIL DESIGN DOES NOT | | | COMPLY WITH FBC16082.2.2. | | | | | | 2.)SHEET AR-SW-1, TYPICAL SECTION | | | THROUGH STAIR RAIL IS NOT LEGIBLE. | | | | | | 3.)STAIR RAIL IS TO COMPLY WITH FBC | | | 1015.3, EXCEPTION 1. | | | | | | CC:DON NEELY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2004-01-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-09 |
Time |
11:21 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-01-02 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2004-01-02 00:00:00 | REV, SHUTTER STORAGE UNDER STAIRS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2003-12-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2003-12-24 |
Time |
08:42 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2003-12-24 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2003-12-24 00:00:00 | FIRESTOP DETAIL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2003-12-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-19 |
Time |
14:35 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2003-12-17 |
Time |
17:41 |
Sent To |
|
|
| Notes |
| 2003-12-17 00:00:00 | ****CORRECTIONS***** | | | FIRESTOP DETAIL | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)THE DETAIL SUBMITTED IS TO BE | | | SIGNED AND SEALED BY THE DESIGNER OF | | | RECORD.INCLUDE A TITLE BLOCK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-05-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-16 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-05-13 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2003-05-13 00:00:00 | OK PER BILL STAPLES | | | | | | SEE CBAA MINUTES, APRIL 17, 2003 CASE | | | NO. 1230 AND JANUARY 8, 2003 CASE NO. | | | 1224. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-04-14 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-04-14 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-04-14 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2003-04-14 00:00:00 | THIRD PAID PLAN REVIEW, NOT A PERMIT | | | APPLICATION. | | | | | | SAME COMMENTS FROM #02100705 DATED | | | 2/27/03 STILL APPLY.A COPY IS | | | ATTACHED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-11-12 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-11-12 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-11-12 00:00:00 | SEE THE NOTES ON 02100713 AND THE OTHER | | | BUILDINGS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
N |
Date |
2003-10-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-06 |
Time |
08:58 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-10-06 |
Time |
08:58 |
Sent To |
B |
|
| Notes |
| 2003-10-06 00:00:00 | FIRE SUBMITTALS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2003-09-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
12:00 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-09-25 |
Time |
07:35 |
Sent To |
|
|
| Notes |
| 2003-09-25 00:00:00 | REV FOR LV LOCATIONS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-09-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-09-25 |
Time |
06:27 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-09-25 |
Time |
06:27 |
Sent To |
|
|
| Notes |
| 2003-09-25 00:00:00 | ROMEX LTR. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-04-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-16 |
Time |
12:33 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-04-11 |
Time |
04:27 |
Sent To |
|
|
| Notes |
| 2003-04-11 00:00:00 | ** ELECTRICAL PLAN STAMPED, READY TO BE | | | ISSUED. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-02-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-20 |
Time |
20:22 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-02-20 |
Time |
20:22 |
Sent To |
|
|
| Notes |
| 2003-02-20 00:00:00 | *************** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE NOTES FROM FIRST | | | REVIEW. NOT ALL NOTES WERE ADDRESSED. | | | | | | PLEASE REMOVE OLD/VOIDED SHEETS FOR | | | NEW SETS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REIVEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-06 |
Time |
06:13 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2002-11-06 |
Time |
06:13 |
Sent To |
|
|
| Notes |
| 2002-11-06 00:00:00 | ***************** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE MISSING HALLWAY | | | OUTLET E-U3. 210-52H | | | | | | 2)NOTE: PLEASE NOTE, A DISC MAY BE REQ`D | | | FOR AHU/WATER HEATERS.NOT ALL LOCK-OFF | | | DEVICES ARE APPROVED BY THE CITY OF | | | WEST PALM BEACH. AHJ. PLEASE NOTE. | | | | | | | | | 3)NOTE: PLEASE CLAROFY HOW 12KW FOR | | | RANGE AT 70% BECOMES 5.6KW? | | | | | | 4)NOTE: PLEASE CLARIFY RECEPT FOR A/C | | | COND UNITS. 210-63 | | | | | | 5)NOTE: PLEASE NOTE/SHOW HEIGHT REQ`- | | | -MENTS PER FHAR 24CFR 100.205 ON PLANS. | | | | | | 6)NOTE: PLEASE NOTE FEEDER SIZES NEED TO | | | BE SIZED PER 310-16/ 75 DEGREE COLUMN. | | | 110-14. | | | | | | 7)NOTE: PLEASE CLARIFY EQUIPMENT GROUND- | | | -ING BETWEEN MAIN AND H PANEL. | | | 250-122 | | | | | | 8)NOTE: PLEASE INDICATE MAINS ON METER | | | BANK ON E-T4.3 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-04-15 |
Time |
08:24 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2003-04-15 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2003-04-15 00:00:00 | PASSED : | | | 1. SEE PERMIT # 03040786 FOR UNDERGROUND | | | UTILITIES AND SITE WORK. | | | IF ANY QUESTION PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2003-02-18 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-02-18 |
Time |
10:28 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-02-18 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2003-02-18 00:00:00 | FAILED: | | | 1. PLEASE SEE THE PREVIOUS REVIEW | | | COMMENTS DATED 11-06-02. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2002-11-06 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-11-06 |
Time |
15:45 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2002-11-06 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2002-11-06 00:00:00 | FAILED : | | | 1. SEE REVIEW COMMENTS FOR PLAN REVIEW # | | | 02100708. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2003-12-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-29 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-12-15 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2003-12-15 00:00:00 | SEE NOTES ON PERMIT 02100705 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-05-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-05-01 |
Time |
16:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-11-14 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-11-14 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-11-14 |
Time |
17:17 |
Sent To |
|
|
| Notes |
| 2002-11-14 00:00:00 | 1) BUILDING ADDRESSES REQUIRED ON | | | BUILDING. | | | | | | 2) FIRE SPRINKLER DRAWINGS ARE REQUIRED | | | AT TIME OF PERMIT SUBMITTAL. ALL | | | BUILDINGS THREE STORIES OR GREATER ARE | | | REQUIRED TO BE PROTECTED PER | | | FS 553.895(2). | | | | | | 3) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | | TO,DURING AND AFTER CONSTRUCTION. | | | | | | 4) WHAT PROVISIONS ARE TO BE MADE WITH | | | WITH REGARDS TO FIRE AND PARAMEDICAL | | | ACCESS THRU THE SECURITY GATES. IF | | | SECURITY GATES ARE ELECTRIC, WHAT | | | PROVISIONS HAVE BEEN MADE IN THE EVENT | | | OF LOSS OF POWER. | | | | | | 5) ALL OPENINGS IN WHICH FIRE RESCUE | | | VEHICLES ARE EXPECTED TO PASS, SHALL | | | BE AT LEAST TWENTY FEET IN CLEAR WIDTH. | | | SEPARATE PERMIT REQUIRED. | | | | | | 6) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE ALARM SYSTEM INSTALLATIONS. | | | | | | 7) ELECTRIC POWERED SMOKE DETECTORS | | | SHALL NOT BE INSTALLED CLOSER THAN | | | THREE FEET FROM AIR CONDITIONER | | | DIFFUSERS. | | | | | | 8) PLEASE PROVIDE A LIFE SAFETY PLAN | | | WITH REGARDS TO EXITING FOR REVIEW. | | | | | | 9) NO EMERGENCY LIGHTING SHOWN OF | | | SIDE EXIT STAIRS. | | | | | | 10) ARE THERE ANY WINDOWS WITHIN 10 | | | FEET OF THE SINGLE EXIT STAIRS. | | | | | | 11) NO PROPANE GRILLS ARE ALLOWED | | | ON EXTERIOR PATIO'S. | | | | | | 12) PLEASE PROVIDE PRESCRIPTIVE CODE | | | REQUIREMENTS FOR ALL HANDRAILS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
26 |
Status |
N |
Date |
2004-02-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-03 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-03 |
Time |
16:37 |
Sent To |
B |
|
| Notes |
| 2004-02-03 00:00:00 | TO SH DESK/SHUTTERS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
25 |
Status |
N |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-29 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-29 |
Time |
10:23 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
24 |
Status |
N |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-29 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-29 |
Time |
10:10 |
Sent To |
B |
|
| Notes |
| 2004-01-29 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
23 |
Status |
N |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-09 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-09 |
Time |
11:20 |
Sent To |
B |
|
| Notes |
| 2004-01-09 00:00:00 | TO SH DESK/SUBMITTALS/RESHORE PLAN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
22 |
Status |
N |
Date |
2004-01-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-09 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-09 |
Time |
11:16 |
Sent To |
B |
|
| Notes |
| 2004-01-09 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2003-12-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-19 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-19 |
Time |
14:42 |
Sent To |
M |
|
| Notes |
| 2003-12-19 00:00:00 | TO PK BOX/EXHAUST FAN DUCT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2003-12-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-19 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-19 |
Time |
14:39 |
Sent To |
M |
|
| Notes |
| 2003-12-19 00:00:00 | TO PK BOX/REFRIG LINE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2003-12-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-19 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-19 |
Time |
14:35 |
Sent To |
B |
|
| Notes |
| 2003-12-19 00:00:00 | TO SH DESK/FIRE STOP METHOD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2003-12-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-16 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-16 |
Time |
12:34 |
Sent To |
B |
|
| Notes |
| 2003-12-16 00:00:00 | TO SH DESK/SUBMITTAL/FIRE STOP METHOD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2003-12-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-10 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-10 |
Time |
16:33 |
Sent To |
B |
|
| Notes |
| 2003-12-10 00:00:00 | TO ST DESK/SUBMITTAL/HANDRAIL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2003-11-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-17 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-11-17 |
Time |
10:20 |
Sent To |
M |
|
| Notes |
| 2003-11-25 00:00:00 | TO MECH IN BOX | | 2003-11-17 00:00:00 | TO HP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2003-11-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-17 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-17 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2003-11-17 00:00:00 | TO COMM BD#46/BLDG II,III,IV,V |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2003-11-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-06 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-06 |
Time |
10:13 |
Sent To |
B |
|
| Notes |
| 2003-11-06 00:00:00 | TO HP DESK/PROD APPR |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2003-10-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-17 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-17 |
Time |
16:33 |
Sent To |
M |
|
| Notes |
| 2003-10-17 00:00:00 | TO PK BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-14 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-14 |
Time |
14:40 |
Sent To |
B |
|
| Notes |
| 2003-10-14 00:00:00 | TO HP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2003-10-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-09 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-09 |
Time |
10:45 |
Sent To |
B |
|
| Notes |
| 2003-10-09 00:00:00 | TO HP DESK/SUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2003-10-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-03 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-03 |
Time |
10:14 |
Sent To |
B |
|
| Notes |
| 2003-10-03 00:00:00 | TO HP DESK/SUB PROD APPRVLS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-02 |
Time |
12:00 |
Sent To |
E |
|
| Notes |
| 2003-10-02 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-02 |
Time |
11:46 |
Sent To |
FIRE |
|
| Notes |
| 2003-10-02 00:00:00 | TO FIRE/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-02 |
Time |
11:26 |
Sent To |
P |
|
| Notes |
| 2003-10-02 00:00:00 | TO KS BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-02 |
Time |
11:20 |
Sent To |
M |
|
| Notes |
| 2003-10-02 00:00:00 | TO PK DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-09-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-16 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-16 |
Time |
12:33 |
Sent To |
E |
|
| Notes |
| 2003-09-16 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-08-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-27 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-27 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2003-08-27 00:00:00 | ON COMM BD #1 - PLANS ON RACK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-05-01 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-01 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-01 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2003-05-01 00:00:00 | COMM BOARD #39. PLANS NEXT TO CONF ROOM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-04-03 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-03 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-03 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2003-04-03 00:00:00 | COMM BOARD #10, PLANS NEXT TO RACK | | | COVER SHEET GIVEN TO SHIRLEY. | | | 1ST SET OF EACH BLDG PLANS ON TABLE, 2ND | | | & 3D SET BEHIND TABLE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-02-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-13 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-13 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2003-02-13 00:00:00 | #49 COMM BOARD | | | PLANS ON BOTTOM OF RACK BY CONFERENCE | | | ROOM. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-12-23 |
Time |
14:37 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2003-12-23 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2003-12-23 00:00:00 | SUBMITTAL DWG/REFRIGERANT SHAFT DETAIL |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2003-11-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-19 |
Time |
14:42 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2003-11-18 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2003-11-18 00:00:00 | PLEASE NOTE PLAN SHEET AC-DT2 IS DENIED. | | | PLAN OMITTED DETAIL OF SHAFT FOR THE | | | REFRIGERATION LINES.AS PER ASHRAE | | | 15-92 SECTION 11.12.3 REFRIGERANT PIPING | | | SHALL NOT BE INSTALLED VERTICALLY | | | THROUGH FLOORS FROM ONE STORY TO ANOTHER | | | EXCEPT AS FOLLOWS: | | | (B) IN APPROVED RIGID, TIGHT AND | | | CONTINUOUS FIRE-RESISTING PIPE DUCT OR | | | SHAFT. ON THE OTHER WALL OF THE BUILDING | | | (NOT IN AIR SHAFT OR CLOSED COURT).THE | | | SHAFT SHALL BE VENTED TO THE OUTSIDE OR | | | TO THE SPACE SERVED BY THE SYSTEM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2003-10-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-10-21 |
Time |
11:49 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-10-21 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2003-10-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-17 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2003-10-06 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2003-10-06 00:00:00 | DENIED:TYPE IV | | | PLAN SHEET AC-C1 INDICATES DRYER EXHAUST | | | DUCT 22" UP WHICH WOULD INDICATE A SUB- | | | DUCT METHOD.PLAN SHEET AC-D2 INDICATES | | | DUCT RUNNING THROUGH THE ROOF.PLEASE | | | CLARIGY WHICH METHOD WILL BE USED.SUB- | | | DUCT METHOD HAS ADDITIONAL REQUIREMENTS | | | THAT WILL NEED TO BE ADDRESSED. | | | | | | PLEASE NOTE AS PER THE "FAIR HOUSING | | | ACT" ENVIRONMENTAL CONTROLS IN ADDITION | | | TO ELECTRICAL CONTROLS SHALL BE LOCATED | | | AT A HEIGHT ACCESSIBLE AS PER THE "FAIR | | | HOUSING ACT DESIGN MANUAL". | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2003-04-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:20 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2003-04-16 |
Time |
09:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
|
Date |
2003-04-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-04-03 |
Time |
10:19 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-04-03 00:00:00 | AS PER MTG 4-3-03, COMMENTS ADDRESSED | | | PLANS NEED TO BE STAMPED |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-02-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-19 |
Time |
11:50 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-02-19 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2003-02-19 00:00:00 | PROVISO:TYPE IV | | | 1.PLAN SHEET AC-D1 GE WASHER/DRYER | | | MODEL SPECIFICATIONS, SPECS INDICATE | | | ELECTRIC & GAS DRYERS, SHOULD GAS DRYERS | | | BE INSTALLED CALCULATIONS FOR COMBUSTION | | | AIR WILL BE REQUIRED. | | | | | | 2.PLAN SHEET AC-D2 DETAIL FOR TOILET | | | EXHAUST, AS PER 2001 FBC(M) 607.4, | | | DUCTS EXTENDING THROUGH MORE THAN ONE | | | FLOOR SHALL BE PROTECTED BY A SHAFT | | | ENCLOSURE HAVING A FIRE RESISTANCE | | | RATING OF 1HR FOR BUILDINGS LESS THAN | | | 4 STORIES & 2HR FOR BUILDINGS GREATER | | | THAN 4 STORIES. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-11-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-11-05 |
Time |
10:13 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2002-11-05 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2002-11-05 00:00:00 | DENIED: TYPE IV | | | | | | PLEASE CLARIFY THE FOLLOWING INFORMATION | | | | | | 1.NOTES CONCERNING THE DRYER & TOILET | | | EXHASUT ARE NOT CLEAR.PLAN SHEET | | | AC-U3 NOTE INDICATES SHAFT TO START | | | AT THE 2ND FLOOR AT THE ELECTRICAL | | | CLOSET?DETAIL ON PLAN SHEET AC-D1 | | | INDICATES A 1 HR RATE CAULK.PLAN | | | SHEET A-DT1 SHOWS A 1 HR SHAFT | | | DETAIL FOR THE TOILET & DRYER | | | EXHAUST. | | | | | | PLEASE PROVIDE A RISER DETAIL | | | SHOWING WHERE THE SHAFT DEGINS & | | | ENDS.REFERENCE PLAN SHEET A-DT1, | | | (SHAFT DETAIL) ON THE MECHANICAL | | | PLAN. | | | | | | 2.PLAN SHEET AC-D1 - NOTE #2 STATES, | | | DRYER EXHAUST DISCHARGE ON ROOF | | | SHALL BE SIMILAR TO TOILET EXHAUST | | | DISCHARGE BUT SHALL NOT BE SCREENED. | | | AS PER 2001 FBC(M) 504.4, SHALL | | | TERMINATE OUTSIDE OF THE BUILDING | | | & SHALL BE EQUIPPED WITH A BACKDRAFT | | | DAMPER. | | | | | | 3.PROVIDE OUTSIDE AIR CALCULATIONS IN | | | ACCORDANCE WITH 2001 FBC(M) 402.2 | | | FOR NATURAL VENTILATION OR TABLE | | | 403.3.PROVIDE CALCULATIONS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
P |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-01-06 |
Time |
18:43 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-01-06 |
Time |
18:43 |
Sent To |
|
|
| Notes |
| 2004-01-06 00:00:00 | REVISION OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
N |
Date |
2003-10-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-28 |
Time |
18:19 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-10-28 |
Time |
18:19 |
Sent To |
B |
|
| Notes |
| 2003-10-28 00:00:00 | NO PLUMBING REVISION SUBMITTED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2003-10-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-10-11 |
Time |
15:33 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-10-11 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2003-10-11 00:00:00 | SUBMITTAL OK - 3M FIRESTOP |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2003-09-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:26 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-09-29 |
Time |
17:48 |
Sent To |
|
|
| Notes |
| 2003-09-29 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHT P-T4.1 REVISION #3 NOT FOUND. | | | PLEASE CLAIRFY. | | | 2) SHT P-T4.2 REVISIONS #1 & 2 NOT FOUND | | | PLEASE CLAIRFY. | | | 3) SHT P-T4.3 REVISION#3 NOT FOUND. | | | PLEASE CLAIRFY. | | | 4) SHT P-D1 THERMAL EXPANSION CONTROL. | | | SUBMIT MANUF. SPECIFICATION SHEETS ON | | | THERMAL EXPANSION VALVE TO SHOW CAPABIL- | | | ITY OF CONTROLLING EXPANSION FOR ALL 24 | | | UNITS. | | | 5) SHT P-D1 RELIEF VALVE DISCHARGE LINE | | | (P/T) AND EMERGENCY PAN DRAIN LINES | | | SHALL BE 2" UNDERGROUND PER SECTION | | | 710.3 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2003-08-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-06 |
Time |
17:25 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-08-06 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2003-08-06 00:00:00 | REVISION DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT P-T4.1 CLEANOUTS REQUIRED PER SEC | | | 708.3.2 & 708.3.3. ALSO SHOW ON RISER | | | DIAGRAM SHT P-T4.2. | | | 2) SHT P-T4.3 STILL HAS ORIGINAL BLDG. | | | DRAIN RISER DIAGRAM AND WATER RISER | | | DIAGRAMS. REVISION FOR THESE HAS BEEN | | | SUBMITTED ON SHT P-T4.2. THESE REVISIONS | | | SHOULD BE SUBMITTED ON THE ORIG. SHEETS | | | THAT THEY WERE ORIGINALLY APPROVED ON TO | | | AVOID CONFUSION. ALSO ROOF PLAN HAS BEEN | | | DELETED ON SHT P-T4.2. PLEASE CLAIRFY. | | | ---COMMENTS 3) THRU 6) --- SEE COMMENTS | | | ON PERMIT #02100705 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-04-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-14 |
Time |
08:12 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-04-14 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2003-04-14 00:00:00 | PASSED/PROVISO | | | | | | REVISION REQUIRED SHT P-T4.3 SHOWING | | | CLEANOUTS IN BLDG DRAIN IN BREEZEWAY |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-03-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-05 |
Time |
13:41 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-03-05 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2003-03-05 00:00:00 | DENIED | | | | | | SEE COMMENTS FROM REVIEW FOR PERMIT NUM- | | | BER 02100705. (TYPE 1) |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-11-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-11-06 |
Time |
16:47 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2002-11-06 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2002-11-06 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FHA-AMEND 98 DESIGN MANUAL | | | | | | 1) SHTS A-U2 & A-U3, INDICATE ON PLANS | | | SPECIFICATION "A" OR "B" FOR BATHROOMS | | | PER REQUIREMENT 7B PAGE 7.35 DESIGN | | | MANUAL FHA-98. | | | 2) SHT ADT-II BACKING FOR W/C'S AND TUBS | | | TO BE ACCORDING TO REQUIREMENT 6 PAGE | | | 6.9 DESIGN MANUAL FHA-98 | | | 3) SHT ADT-II THE TOP OF LAV FIXTURE RIM | | | IS A MAXIMUM OF 2'10" ABOVE FINISHED | | | FLOOR. PLEASE INDICATE ON BATHROOM DE- | | | TAIL. | | | 4) SHT P-U2 DOMESTIC WATER RISER, LOCATE | | | WATER HAMMER ARRESTORS AT WASH MACHINE | | | NEAR FIXTURE, NOT AT THE TOP OF THE | | | RISER AS SHOWN. | | | 5) SHT P-T4.1 BLDG DRAIN CLEAN OUTS MAX- | | | IMUM OF 100'. TWO WAY C/O REQUIRED IN | | | THE BREEZEWAYS SEC 708.3.1. ALSO SHOW | | | C/O'S ON SANITARY RISER DIAGRAM SHEET | | | P-T4.3 | | | 6) SHT P-D1 PLUMBING GENERAL NOTES #6, | | | DIELECTRIC UNIONS NOT APPROVED FOR WATER | | | USAGE. PLEASE DELETE REFERENCE. | | | 7) SHT P-D1 WATER HEATER DETAIL, THE | | | RELIEF VALVE DISCHARGE PIPE SHALL NOT | | | HAVE ANY TRAPPED SECTIONS. SEC 504.7.1. | | | THERMAL EXPANSION CONTROL IS ALSO RE- | | | QUIRED. SECTION 607.3.2. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-30 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2003-04-30 |
Time |
08:17 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-04-30 00:00:00 | "MASTER" | | | REVIEW NOT REQUIRED |
|
|