Plan Review Details - Permit 02100711
Plan Review Stops For Permit 02100711
Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2004-01-16 Cont ID  
Sent By csiegber Date 2004-02-03 Time 16:36 Rev Time 0.50
Received By shill Date 2004-01-16 Time 09:52 Sent To  
Notes
2004-01-16 00:00:00RESHORE PLAN PREPARED BY CALVIN FOONG,
 PE DATED 8/12/03

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2004-01-02 Cont ID  
Sent By csiegber Date 2004-01-09 Time 11:27 Rev Time 0.50
Received By shill Date 2004-01-02 Time 15:57 Sent To  
Notes
2004-01-02 00:00:00REVISION, SHUTTER STORAGE UNDER STAIRS

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2003-12-23 Cont ID  
Sent By shill Date 2003-12-23 Time 17:37 Rev Time 0.50
Received By shill Date 2003-12-23 Time 17:37 Sent To  
Notes
2003-12-23 00:00:00FIRESTOP DETAIL

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2003-12-17 Cont ID  
Sent By csiegber Date 2003-12-19 Time 14:38 Rev Time 0.50
Received By shill Date 2003-12-17 Time 17:38 Sent To  
Notes
2003-12-17 00:00:00****CORRECTIONS****
 FIRESTOP DETAIL
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
  
 1.)THE DETAIL SUBMITTED IS TO BE
 SIGNED AND SEALED BY THE DESIGNER OF
 RECORD.INCLUDE A TITLE BLOCK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-12-15 Cont ID  
Sent By csiegber Date 2003-12-16 Time 12:34 Rev Time 1.00
Received By shill Date 2003-12-15 Time 10:55 Sent To  
Notes
2003-12-15 00:00:00SHOP DRAWINGS, RAILINGS
 **PROVISO**SUBMIT 3 SETS FOR EACH
 BUILDING TYPE

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-05-13 Cont ID  
Sent By csiegber Date 2003-12-10 Time 16:32 Rev Time 0.00
Received By sthyng Date 2003-05-13 Time 13:44 Sent To  
Notes
2003-05-13 00:00:00OK PER BILL STAPLES
  
 SEE CBAA MINUTES, APRIL 17, 2003 CASE
 NO. 1230 AND JANUARY 8, 2003 CASE NO.
 1224.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-04-14 Cont ID  
Sent By hpiskura Date 2003-04-14 Time 12:56 Rev Time 0.00
Received By hpiskura Date 2003-04-14 Time 12:45 Sent To  
Notes
2003-04-14 00:00:00THIRD PAID PLAN REVIEW, NOT A PERMIT
 APPLICATION.
  
 SAME COMMENTS AS 2/27/03 ON #0211705
 STILL APPLY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-11-12 Cont ID  
Sent By hpiskura Date 2002-11-12 Time 11:00 Rev Time 0.00
Received By hpiskura Date   Time   Sent To Z
Notes
2002-11-12 00:00:00SEE 02100713 AND THE OTHER BUILDINGS

Review Stop E ELECTRICAL
Rev No 6 Status N Date 2003-10-06 Cont ID  
Sent By dpalmer Date 2003-10-06 Time 09:00 Rev Time 0.25
Received By dpalmer Date 2003-10-06 Time 09:00 Sent To B
Notes
2003-10-06 00:00:00FIRE SUBMITTALS

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2003-09-25 Cont ID  
Sent By csiegber Date 2003-10-02 Time 11:59 Rev Time 0.33
Received By dpalmer Date 2003-09-25 Time 17:49 Sent To  
Notes
2003-09-25 00:00:00REV FOR L . V.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-09-24 Cont ID  
Sent By dpalmer Date 2003-09-24 Time 19:54 Rev Time 0.25
Received By dpalmer Date 2003-09-24 Time 19:54 Sent To  
Notes
2003-09-24 00:00:00ROMEX LTR.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-04-11 Cont ID  
Sent By csiegber Date 2003-09-16 Time 12:32 Rev Time 0.33
Received By dpalmer Date 2003-04-11 Time 04:39 Sent To  
Notes
2003-04-11 00:00:00***ELECTRICAL PLAN STAMPED, READY TO BE
 ISSUED.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-02-21 Cont ID  
Sent By dpalmer Date 2003-02-21 Time 05:18 Rev Time 0.25
Received By dpalmer Date 2003-02-21 Time 05:18 Sent To  
Notes
2003-02-21 00:00:00*************** UNSAT *****************
  
 1)NOTE: PLEASE SEE NOTES FROM FIRST
 REVIEW. PLEASE SEE THAT NOT ALL NOTES
 WERE ADDRESSED.
  
 PLEASE REMOVE ALL OLD/VOIDED SHEETS FOR
 NEW CLEAN SETS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-11-06 Cont ID  
Sent By dpalmer Date 2002-11-06 Time 11:31 Rev Time 1.00
Received By dpalmer Date 2002-11-06 Time 11:21 Sent To  
Notes
2002-11-06 00:00:00************** UNSAT *****************
  
  
  
  
  
 1)NOTE: PLEASE SHOW HEIGHT REQ`MENTS
 FOR FHAR 24CFR 100.205
  
 2)NOTE: PLEASE NOTE< AHU/WATER HEATER
 MAY REQUIRE DISC`S. NOT ALL "LOCK OFF"
 DEVICES ARE APPROVED BY THE CITY OF
 WEST PALM BEACH/AHJ.PLEASE NOTE THAT
 ANY "LOCK OFF " DEVICE MUST BE APPROVED
 BY THE CHIEF ELECTRICAL INSPECTOR.
  
 3)NOTE: PLEASE NOTE RANGE SHOWN AT 12KW
 AND THEN AT 70% AS 5.6KW? PLEASE CLARIFY
  
 4)NOTE; PLEASE 210-52H FOR HALLWAY
 OUTLETS.
  
 5)NOTE: PLEASE NOTE MISSING EQUIPMENT
 GROUNDING CONDUCTOR FOR "HOUSE" PANEL.
 MAIN TO PANEL.
  
 6)NOTE: PLEASE SHOW/NOTE MAINS FOR
 UNIT ON RISER/METER DIAGRAM.
  
 7)NOTE: PLEASE NOTE MISSING RECEPT FOR
 A/C COND UNITS. 210-63
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2003-04-15 Cont ID  
Sent By mamini Date 2003-04-15 Time 08:33 Rev Time 0.50
Received By mamini Date 2003-04-15 Time 08:33 Sent To  
Notes
2003-04-15 00:00:00PASSED:
 1. SEE PERMIT # 03040786 FOR UNDERGROUND
 UTILITIES AND SITE WORK.
 IF ANY QUESTION PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2003-02-18 Cont ID  
Sent By mamini Date 2003-02-18 Time 10:25 Rev Time 1.00
Received By mamini Date 2003-02-18 Time 10:24 Sent To  
Notes
2003-02-18 00:00:00FAILED:
 1. PLEASE SEE THE PREVIOUS REVIEW
 COMMENTS DATED 10-15-02.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2002-10-15 Cont ID  
Sent By mamini Date 2002-10-15 Time 14:46 Rev Time 1.00
Received By mamini Date 2002-10-15 Time 14:46 Sent To  
Notes
2002-10-15 00:00:00FAILED :
 1. PLEASE SUBMIT CIVIL/SITE PLANS FOR
 OUR REVIEW AND APPROVAL.PLANS SHOULD
 INCLUDE STORM WATER, PERVIOUS AND
 IMPERVIOUS CALCULATIONS FOR THIS PHASE.
 ALSO INCLUDE A COPY OF NORTHERN AND
 SFWMD PERMITS.
 2. PLESAE NOTE THAT A SEPARATE PERMIT
 APPLICATION AND FEES FOR CIVIL/SITE WORK
 AT THE TIME OF ACTUAL PERMITTING WILL BE
 REQUIRED.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2003-12-15 Cont ID  
Sent By csiegber Date 2004-01-29 Time 10:22 Rev Time 0.00
Received By nmccray Date 2003-12-15 Time 12:04 Sent To  
Notes
2003-12-15 00:00:00SEE NOTES ON PERMIT 02100705

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-05-01 Cont ID  
Sent By csiegber Date 2003-10-02 Time 11:47 Rev Time 0.00
Received By nmccray Date 2003-05-01 Time 16:43 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-11-08 Cont ID  
Sent By mcarsill Date 2002-11-08 Time 20:13 Rev Time 0.00
Received By mcarsill Date 2002-11-08 Time 20:13 Sent To  
Notes
2002-11-08 00:00:001) BUILDING ADDRESSES REQUIRED ON
 BUILDING.
  
 2) FIRE SPRINKLER DRAWINGS ARE REQUIRED
 AT TIME OF PERMIT SUBMITTAL. ALL
 BUILDINGS THREE STORIES OR GREATER
 ARE REQUIRED TO BE FIRE SPRINKLER
 PROTECTED PER FS 553.895(2)
  
 3) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO,DURING AND AFTER CONSTRUCTION.
  
 4) WHAT PROVISIONS ARE TO BE MADE WITH
 REGARDS TO FIRE AND PARAMEDICAL ACCESS
 THRU THE SECURITY GATES. IF SECURITY
 GATES ARE ELECTRIC, WHAT PROVISIONS
 HAVE BEEN MADE IN EVENT OF LOSS OF
 POWER.
  
 5) ALL OPENINGSIN WHICH FIRE RESCUE
 VEHICLES ARE EXPECTED TO PASS, SHALL
 BE AT LEAST TWENTY FEET IN CLEAR WIDTH.
  
 6) ELECTRIC POWERED SMOKE DETECTORS
 SHALL NOT BE INSTALLED CLOSER THAN
 THREE FEET FROM AIR CONDITIONER
 DIFFUSERS.
  
 7) SEPARATE PLANS AND PERMITS REQUIRED
 FOR FIRE ALARM SYSTEM INSTALLATIONS.
  
 8) PLEASE PROVIDE A LIFE SAFETY PLAN
 WITH REGARDS TO EXITING FOR REVIEW.
  
 9) NO EMERGENCY LIGHTING SHOWN OF SIDE
 EXIT STAIRS.
  
 10) ARE THERE ANY WINDOWS WITHIN 10
 FEET OF THE SINGLE EXIT STAIRS.
  
 11) NO PROPANE GRILLS ARE ALLOWED ON
 EXTERIOR PATIO'S.
  
 12) PLEASE PROVIDE PRESCRIPTIVE CODE
 REQUIREMENTS FOR ALL HANDRAILS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 24 Status N Date 2004-02-03 Cont ID  
Sent By csiegber Date 2004-02-03 Time 16:36 Rev Time 0.00
Received By csiegber Date 2004-02-03 Time 16:36 Sent To B
Notes
2004-02-03 00:00:00TO SH DESK/SHUTTERS

Review Stop I INCOMING/PROCESSING
Rev No 23 Status N Date 2004-01-29 Cont ID  
Sent By csiegber Date 2004-01-29 Time 10:22 Rev Time 0.00
Received By csiegber Date 2004-01-29 Time 10:22 Sent To FIRE
Notes
2004-01-29 00:00:00RESUB

Review Stop I INCOMING/PROCESSING
Rev No 22 Status N Date 2004-01-09 Cont ID  
Sent By csiegber Date 2004-01-09 Time 11:27 Rev Time 0.00
Received By csiegber Date 2004-01-09 Time 11:27 Sent To B
Notes
2004-01-09 00:00:00TO SH DESK/RESHORE PLAN

Review Stop I INCOMING/PROCESSING
Rev No 21 Status N Date 2003-12-19 Cont ID  
Sent By csiegber Date 2003-12-19 Time 14:42 Rev Time 0.00
Received By csiegber Date 2003-12-19 Time 14:42 Sent To M
Notes
2003-12-19 00:00:00TO PK BOX/EXHAUST FAN DUCT

Review Stop I INCOMING/PROCESSING
Rev No 20 Status N Date 2003-12-19 Cont ID  
Sent By csiegber Date 2003-12-19 Time 14:38 Rev Time 0.00
Received By csiegber Date 2003-12-19 Time 14:38 Sent To M
Notes
2003-12-19 00:00:00TO PK BOX/REFRIG LINE

Review Stop I INCOMING/PROCESSING
Rev No 19 Status N Date 2003-12-19 Cont ID  
Sent By csiegber Date 2003-12-19 Time 14:35 Rev Time 0.00
Received By csiegber Date 2003-12-19 Time 14:35 Sent To B
Notes
2003-12-19 00:00:00TO SH DESK/FIRE STOP METHOD

Review Stop I INCOMING/PROCESSING
Rev No 18 Status N Date 2003-12-16 Cont ID  
Sent By csiegber Date 2003-12-16 Time 12:34 Rev Time 0.00
Received By csiegber Date 2003-12-16 Time 12:34 Sent To B
Notes
2003-12-16 00:00:00TO SH DESK/SUBMITTAL/FIRE STOP METHOD

Review Stop I INCOMING/PROCESSING
Rev No 17 Status N Date 2003-12-10 Cont ID  
Sent By csiegber Date 2003-12-10 Time 16:32 Rev Time 0.00
Received By csiegber Date 2003-12-10 Time 16:32 Sent To B
Notes
2003-12-10 00:00:00TO ST DESK/SUBMITTAL/HANDRAIL

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2003-11-25 Cont ID  
Sent By csiegber Date 2003-11-17 Time 10:20 Rev Time 0.00
Received By sthyng Date 2003-11-17 Time 10:20 Sent To M
Notes
2003-11-25 00:00:00TO MECH IN BOX
2003-11-17 00:00:00TO HP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2003-11-06 Cont ID  
Sent By csiegber Date 2003-11-06 Time 10:12 Rev Time 0.00
Received By csiegber Date 2003-11-06 Time 10:12 Sent To B
Notes
2003-11-06 00:00:00TO HP DESK/PROD APPR

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2003-11-04 Cont ID  
Sent By csiegber Date 2003-11-04 Time 16:14 Rev Time 0.00
Received By csiegber Date 2003-11-04 Time 16:14 Sent To P
Notes
2003-11-04 00:00:00TO KS DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2003-10-17 Cont ID  
Sent By csiegber Date 2003-10-17 Time 16:42 Rev Time 0.00
Received By csiegber Date 2003-10-17 Time 16:42 Sent To P
Notes
2003-10-17 00:00:00TO KS BOX

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2003-10-14 Cont ID  
Sent By csiegber Date 2003-10-14 Time 14:42 Rev Time 0.00
Received By csiegber Date 2003-10-14 Time 14:41 Sent To B
Notes
2003-10-14 00:00:00TO HP DESK

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2003-10-09 Cont ID  
Sent By csiegber Date 2003-10-09 Time 10:47 Rev Time 0.00
Received By csiegber Date 2003-10-09 Time 10:47 Sent To B
Notes
2003-10-09 00:00:00TO HP DESK

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2003-10-03 Cont ID  
Sent By csiegber Date 2003-10-03 Time 10:12 Rev Time 0.00
Received By csiegber Date 2003-10-03 Time 10:12 Sent To B
Notes
2003-10-03 00:00:00TO HP DESK/SUB PROD APPRVLS

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2003-10-02 Cont ID  
Sent By csiegber Date 2003-10-02 Time 11:59 Rev Time 0.00
Received By csiegber Date 2003-10-02 Time 11:59 Sent To E
Notes
2003-10-02 00:00:00TO DP DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2003-10-02 Cont ID  
Sent By csiegber Date 2003-10-02 Time 11:47 Rev Time 0.00
Received By csiegber Date 2003-10-02 Time 11:47 Sent To FIRE
Notes
2003-10-02 00:00:00TO FIRE/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2003-10-02 Cont ID  
Sent By csiegber Date 2003-10-02 Time 11:27 Rev Time 0.00
Received By csiegber Date 2003-10-02 Time 11:27 Sent To P
Notes
2003-10-02 00:00:00TO KS BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-10-02 Cont ID  
Sent By csiegber Date 2003-10-02 Time 11:19 Rev Time 0.00
Received By csiegber Date 2003-10-02 Time 11:19 Sent To M
Notes
2003-10-02 00:00:00TO PK DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-09-16 Cont ID  
Sent By csiegber Date 2003-09-16 Time 12:32 Rev Time 0.00
Received By csiegber Date 2003-09-16 Time 12:32 Sent To E
Notes
2003-09-16 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-08-27 Cont ID  
Sent By csiegber Date 2003-08-27 Time 13:47 Rev Time 0.00
Received By csiegber Date 2003-08-27 Time 13:47 Sent To  
Notes
2003-08-27 00:00:00ON COMM BD#1 - PLANS ON RACK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-05-01 Cont ID  
Sent By shernand Date 2003-05-01 Time 12:59 Rev Time 0.00
Received By shernand Date 2003-05-01 Time 12:59 Sent To  
Notes
2003-05-01 00:00:00COMM BOARD #39. PLANS NEXT TO CONF ROOM

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-03 Cont ID  
Sent By shernand Date 2003-04-03 Time 13:47 Rev Time 0.00
Received By shernand Date 2003-04-03 Time 13:47 Sent To  
Notes
2003-04-03 00:00:00COMM BOARD #10, PLANS NEXT TO RACK
 COVER SHEET GIVEN TO SHIRLEY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-13 Cont ID  
Sent By dpalmer Date 2003-02-13 Time 15:07 Rev Time 0.00
Received By dpalmer Date 2003-02-13 Time 15:06 Sent To  
Notes
2003-02-13 00:00:00TO COMM BOARD #49
 PLANS ON BOTTOM OF RACK BY CONFERENCE
 ROOM.

Review Stop M MECHANICAL (A/C)
Rev No 8 Status P Date 2003-12-23 Cont ID  
Sent By pkrauss Date 2003-12-23 Time 14:19 Rev Time 0.30
Received By pkrauss Date 2003-12-23 Time 14:19 Sent To  
Notes
2003-12-23 00:00:00SUBMITTAL DWG/REFRIGERANT SHAFT DETAIL

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2003-11-18 Cont ID  
Sent By csiegber Date 2003-12-19 Time 14:42 Rev Time 0.40
Received By pkrauss Date 2003-11-18 Time 10:14 Sent To  
Notes
2003-11-18 00:00:00PLEASE NOTE PLAN SHEET AC-DT2 IS DENIED
 PLAN OMITTED DETAIL OF SHAFT FOR THE
 REFRIGERATION LINES.AS PER ASHRAE
 15-92 SECTION 11.12.3 REFRIGERANT PIPING
 SHALL NOT BE INSTALLED VERTICALLY
 THROUGH FLOORS FROM ONE STORY TO ANOTHER
 EXCEPT AS FOLLOWS:
 (B) IN APPROVED RIGID, TIGHT AND
 CONTINUOUS FIRE-RESISTING PIPE DUCT OR
 SHAFT. ON THE OUTER WALL OF THE BUILDING
 (NOT IN AIR SHAFT OR CLOSED COURT).THE
 SHAFT SHALL BE VENTED TO THE OUTSIDE
 OR TO THE SPACE SERVED BY THE SYSTEM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
 2)NOTE: PLEASE SEE BLDG PLAN REVIEW
 NOTES. PLEASE CORRELATE PLANS/PAPERWORK
 FOR COTTAGES.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2003-10-31 Cont ID  
Sent By pkrauss Date 2003-10-31 Time 07:08 Rev Time 0.40
Received By pkrauss Date 2003-10-31 Time 06:51 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2003-10-06 Cont ID  
Sent By kstevens Date 2003-10-28 Time 18:00 Rev Time 0.00
Received By pkrauss Date 2003-10-06 Time 08:11 Sent To  
Notes
2003-10-06 00:00:00DENIED:TYPE III
 PLAN SHEET AC-C1 INDICATES DRYER EXHAUST
 DUCT 22" UP WHICH WOULD INDICATE A SUB-
 DUCT METHOD.PLAN SHEET AC-D2 INDICATES
 DUCT RUNNING THROUGH THE ROOF.PLEASE
 CLARIFY WHICH METHOD WILL BE USED.SUB-
 DUCT METHOD HAS ADDITIONAL REQUIREMENTS
 THAT WILL NEED TO BE ADDRESSED.
  
 PLEASE NOTE, AS PER THE "FAIR HOUSING
 ACT" ENVIRONMENTAL CONTROLS IN ADDITION
 TO ELECTRICAL CONTROLS SHALL BE LOCATED
 AT A HEIGHT ACCESSIBLE AS PER THE "FAIR
 HOUSING ACT DESIGN MANUAL".
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2003-04-16 Cont ID  
Sent By csiegber Date 2003-10-02 Time 11:20 Rev Time 0.20
Received By pkrauss Date 2003-04-16 Time 09:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status   Date 2003-04-03 Cont ID  
Sent By pkrauss Date 2003-04-03 Time 10:17 Rev Time 0.20
Received By pkrauss Date   Time   Sent To  
Notes
2003-04-03 00:00:00AS PER MTG 4-3-03, COMMENTS ADDRESSED -
 PLANS NEED STAMPING

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-03-05 Cont ID  
Sent By pkrauss Date 2003-03-05 Time 12:20 Rev Time 0.00
Received By pkrauss Date 2003-03-05 Time 12:20 Sent To  
Notes
2003-03-05 00:00:00PROVISO:TYPE III
 1.PLAN SHEET AC-D1 GE WASHER/DRYER
 MODEL SPECIFICATIONS, SPECS INDICATE
 ELECTRIC & GAS DRYERS, SHOULD GAS DRYERS
 BE INSTALLED CALCULATIONS FOR COMBUSTION
 AIR WILL BE REQUIRED.
  
 2.PLAN SHEET AC-D2 DETAIL FOR TOILET
 EXHAUST, AS PER 2001 FBC(M) 607.4,
 DUCTS EXTENDING THROUGH MORE THAN ONE
 FLOOR SHALL BE PROTECTED BY A SHAFT
 ENCLOSURE HAVING A FIRE RESISTANCE
 RATING OF 1HR FOR BUILDINGS LESS THAN
 4 STORIES & 2HR FOR BUILDINGS GREATER
 THAN 4 STORIES.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-11-05 Cont ID  
Sent By pkrauss Date 2002-11-05 Time 10:33 Rev Time 0.00
Received By pkrauss Date 2002-11-05 Time 09:27 Sent To  
Notes
2002-11-05 00:00:00DENIED:TYPE III
  
 PLEASE CLARIFY THE FOLLOWING INFORMATION
  
 1.NOTES CONCERNING THE DRYER & TOILET
 EXHAUST ARE NOT CLEAR.PLAN SHEET
 AC-U3 NOTE INDICATES SHAFT TO START
 AT THE 2ND FLOOR AT THE ELECTRICAL
 CLOSET?DETIAL ON PLAN SHEET AC-D1
 INDICATES A 1 HR CAULK. PLAN
 SHEET A-DT1 SHOWS A 1 HR SHAFT
 DETAIL FOR THE TOILET & DRYER
 EXHAUST.
  
 PLEASE PROVIDE A RISER DETAIL
 SHOWING WHERE THE SHAFT BEGINS &
 ENDS.REFERENCE PLAN SHEET A-DT1,
 (SHAFT DETAIL) ON THE MECHANICAL
 PLAN.
  
 2.PLAN SHEET AC-D1 - NOTE #2 STATES,
 DRYER EXHASUT DISCHARGE ON ROOF
 SHALL BE SIMILAR TO TOILET EXHAUST
 DISCHARGE BUT SHALL NOT BE SCREENED.
 AS PER 2001 FBC(M) 504.4, SHALL
 TERMINATE ON THE OUTSIDE OF THE
 BUILDING & SHALL BE EQUIPPED WITH A
 BACKDRAFT DAMPER.
  
 3.PROVIDE OUTSIDE AIR CALCULATIONS IN
 ACCORDANCE WITH 2001 FBC(M) 402.2
 FOR NATURAL VENTILATION OR TABLE
 403.3.PROVIDE CALCULATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 8 Status P Date 2004-01-06 Cont ID  
Sent By kstevens Date 2004-01-06 Time 18:37 Rev Time 0.50
Received By kstevens Date 2004-01-06 Time 18:37 Sent To  
Notes
2004-01-06 00:00:00REVISION OK

Review Stop P PLUMBING
Rev No 7 Status F Date 2003-10-28 Cont ID  
Sent By csiegber Date 2003-11-04 Time 16:14 Rev Time 0.50
Received By kstevens Date 2003-10-28 Time 17:47 Sent To M
Notes
2003-10-28 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
 FBC-2001 PLUMBING
  
 1) SECTION 606.1(3) ON THE BASE OF EVERY
 WATER RISER PIPE IN OCCUPANCIES OTHER
 THAN MULTIPLE FAMILY RESIDENTIAL OCCUP-
 ANCIES THAT ARE TWO STORES OR LESS IN
 HEIGHT AND ONE AND TWO FAMILY RESIDENT-
 IAL OCCUPANCIES, FULL-OPEN VALVES SHALL
 BE INSTALLED. ACCESS SHALL BE PROVIDED
 TO ALL REQUIRED FULL-OPEN VALVES. SECT-
 ION 606.3
  
 2) THE #530C WATTS THERMAL EXPANSION
 CONTROL VALVE IS NOT APPROVED FOR MULTI-
 HEATER USE PER MANUFACTURE REPRESENTA-
 TIVE. INDICATE HOW THERMAL EXPANSION
 CONTROL WILL BE ACCOMPLISHED. 607.3.2
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 6 Status P Date 2003-10-11 Cont ID  
Sent By csiegber Date 2003-10-17 Time 16:42 Rev Time 0.25
Received By kstevens Date 2003-10-11 Time 15:31 Sent To  
Notes
2003-10-11 00:00:00SUBMITTAL OK - 3M FIRESTOP

Review Stop P PLUMBING
Rev No 5 Status F Date 2003-09-29 Cont ID  
Sent By csiegber Date 2003-10-02 Time 11:27 Rev Time 0.50
Received By kstevens Date 2003-09-29 Time 17:22 Sent To  
Notes
2003-09-29 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT P-T3/1 REVISION #3 NOT FOUND.
 PLEASE CLAIRFY.
 2) SHT P-T3.2 REVISION #1 NOT FOUND.
 PLEASE CLAIRFY.
 3) SHT P-T3.3 REVISION #1 NOT FOUND.
 PLEASE CLAIRFY.
 4) SHT P-D1 THERMAL EXPANSION CONTROL,
 SUBMIT MANUF. SPECIFICATION SHEETS ON
 THERMAL EXPANSION VALVE TO SHOW CAPABIL-
 ITY OF CONTROLLING EXPANSION FOR ALL 24
 UNITS.
 5) SHT P-D1 RELIEF VALVE DISCHARGE LINE
 (P/T) AND EMERGENCY PAN DRAIN LINES
 SHALL BE 2" UNDERGROUND PER SECTION
 710.3
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 4 Status F Date 2003-08-06 Cont ID  
Sent By kstevens Date 2003-08-06 Time 17:06 Rev Time 0.50
Received By kstevens Date 2003-08-06 Time 17:06 Sent To  
Notes
2003-08-06 00:00:00REVISION DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT P-T3.1 CLEANOUTS REQUIRED PER SEC
 708.3.2 & 708.3.3. ALSO SHOW ON RISER
 DIAGRAM SHT P-T3.2
 2) SHT P-T3.3 STILL HAS ORIGINAL BLDG.
 DRAIN RISER DIAGRAM AND WATER RISER
 DIAGRAMS. REVISION FOR THESE HAS BEEN
 SUBMITTED ON SHT P-T3.2. THESE REVISIONS
 SHOULD BE SUBMITTED ON THE ORIG. SHEETS
 THAT THEY WERE ORIGINALLY APPROVED ON TO
 AVOID CONFUSION. ALSO ROOF PLAN HAS BEEN
 DELETED ON SHT P-T3.2. PLEASE CLAIRFY
 --- COMMENTS 3) THRU 6) --- SEE COMMENTS
 ON PERMIT #02100705
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-04-18 Cont ID  
Sent By kstevens Date 2003-04-18 Time 10:37 Rev Time 0.33
Received By kstevens Date 2003-04-18 Time 10:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-03-05 Cont ID  
Sent By kstevens Date 2003-03-05 Time 13:31 Rev Time 0.25
Received By kstevens Date 2003-03-05 Time 13:29 Sent To  
Notes
2003-03-05 00:00:00DENIED
  
 SEE COMMENTS FR0M REVIEW FOR PERMIT NUM-
 BER 02100705 (TYPE 1)

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-11-02 Cont ID  
Sent By kstevens Date 2002-11-02 Time 17:11 Rev Time 0.50
Received By kstevens Date 2002-11-02 Time 17:11 Sent To  
Notes
2002-11-02 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FHA-AMEND 98 DESIGN MANUAL
  
 1) SHTS A-U2 & A-U3, INDICATE ON PLANS
 SPECIFICATION "A" OR "B" FOR BATHROOMS
 PER REQUIREMENT 7B PAGE 7.35 DESIGN
 MANUAL FHA-98
 2) SHT ADT-II BACKING FOR W/C'S AND TUBS
 TO BE ACCORDING TO REQUIREMENT 6 PAGE
 6.9 DESIGN MANUAL FHA-98
 3) SHT ADT-II THE TOP OF LAV FIXTURE RIM
 IS A MAXIMUM OF 2'10" ABOVE FINISHED
 FLOOR. PLEASE INDICATE ON BATHROOM DE-
 TAIL.
 4) SHT P-U2 DOMESTIC WATER RISER, LOCATE
 WATER HAMMER ARRESTORS AT WASH MACHINE
 NEAR FIXTURE, NOT AT THE TOP OF THE DROP
 5) SHT P-T1.1 BLDG. DRAIN CLEAN OUTS
 MAXIMUM OF 100'. TWO WAY C/O REQUIRED IN
 BOTH BREEZE WAYS, 708.3.1. ALSO SHOW C/O
 ON SANITARY RISER DIAGRAM SHT P-T1.3
 6) SHT P-D1 PLUMBING GENERAL NOTES #6,
 DIELECTRIC UNIONS NOT APPROVED FOR WATER
 USAGE. PLEASE DELETE REFERENCE.
 7) SHT P-D1 WATER HEATER DETAIL, THE
 RELIEF VALVE DISCHARGE PIPE SHALL NOT
 HAVE ANY TRAPPED SECTIONS. SEC 504.7.1
 THERMAL EXPANSION CONTROL IS ALSO RE-
 QUIRED. SECTION 607.3.2
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status N Date 2003-04-30 Cont ID  
Sent By hpiskura Date 2002-11-12 Time 11:21 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2003-04-30 00:00:00"MASTER"