Plan Review Details - Permit 02100667
Plan Review Stops For Permit 02100667
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-11-01 Cont ID  
Sent By dpalmer Date 2002-11-01 Time 06:25 Rev Time 0.50
Received By dpalmer Date 2002-11-01 Time 06:25 Sent To B
Notes
2002-11-01 00:00:00*** NOTES REDLINED FOR GROUNDING
 ELECTRODE SYSTEM MISSING FOOTER STEEL
 AND COLD WATER. 250-50

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-03-01 Cont ID  
Sent By csiegber Date 2004-03-01 Time 15:37 Rev Time 0.00
Received By csiegber Date 2004-03-01 Time 15:37 Sent To P
Notes
2004-03-01 00:00:00TO KS DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-05-20 Cont ID  
Sent By shernand Date 2003-05-20 Time 16:44 Rev Time 0.00
Received By shernand Date 2003-05-20 Time 16:44 Sent To M
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-10-28 Cont ID  
Sent By shernand Date 2003-05-20 Time 16:44 Rev Time 0.50
Received By hmoser Date 2002-10-28 Time 19:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-03-12 Cont ID  
Sent By kstevens Date 2004-03-12 Time 07:30 Rev Time 0.50
Received By kstevens Date 2004-03-12 Time 07:30 Sent To  
Notes
2004-03-12 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-10-26 Cont ID  
Sent By csiegber Date 2004-03-01 Time 15:37 Rev Time 0.33
Received By jleech Date 2002-10-26 Time 11:12 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2003-01-28 Cont ID  
Sent By hpiskura Date 2003-01-28 Time 13:16 Rev Time 0.00
Received By hpiskura Date 2003-01-28 Time 12:39 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-11-18 Cont ID  
Sent By hpiskura Date 2002-11-18 Time 15:55 Rev Time 0.00
Received By hpiskura Date 2002-11-15 Time 09:56 Sent To  
Notes
2002-11-18 00:00:00THE CONCRETE DESIGN STANDARDS CITED ON
 SHEET A1 ARE OUTDATED AND/OR WRONG
 APPLICATION.SEE FBC 1900 AND FBC 3500
  
 STEEL AND MASONRY, SAME.SEE FBC 2100
 AND FBC 3500.ALSO, PLEASE PROVIDE THE
 DESIGN INFORMATION FOR THE REINFORCED
 MASONRY, IE; F'M, POUR HEIGHTS, GROUT
 SPECIFICATION, TESTS REQUIRED, IF ANY.
  
 THE 16" X 16" MASONRY COLUMN AT THE
 PATIO DEPICTED ON SHEET A2 DOES NOT
 SPECIFY ANY STEEL.PLEASE REVISE AS
 NECESSARY.
  
 FOUNDATION NOTE #5 ON SHEET A2 RE:
 FOOTING DESIGNED IN ACCORDANCE WITH FBC
 2402.2, IS NOT A VALID CODE SECTION.
 MORE IMPORTANTLY, FBC 104.2.1 DOES NOT
 ALLOW CITING OF CODE SECTIONS AS A
 SUBSTITUTE FOR SPECIFIC DESIGN
 INFORMATION.
  
 SHEET A3 SHOW THE DESIGN CRITERIA FOR
 THE DELEGATED DESIGN RESPONSIBILITY FOR
 THE SOFFIT BEAM ON THE PATIO.
  
 SHOW THE WIND DESIGN INFORMATION ON THE
 PLANS IN ACCORDANCE WITH FBC 1606.1.7.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-10-18 Cont ID  
Sent By sgraham Date 2002-10-18 Time 08:42 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***