|
 |
 |
 |
 |
 |
Plan Review Details - Permit 02100647
| Plan Review Stops For Permit 02100647 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-01-17 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2003-01-17 |
Time |
14:56 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-11-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-25 |
Time |
12:40 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2002-11-25 |
Time |
12:06 |
Sent To |
R |
|
| Notes |
| 2002-11-25 00:00:00 | | | | TO LOU HATTEN./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-10-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-18 |
Time |
16:44 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2002-10-18 |
Time |
15:53 |
Sent To |
B |
|
| Notes |
| 2002-10-18 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | | | | PLEASE PROVIDE THE FOLLOWING | | | INFORMATION,MAKE NECESSARY CHANGES ON | | | THE PLANS AND RESUBMIT FOR REVIEW. | | | | | | 1} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 2} PLEASE NOTE FRONT AND REAR | | | RECEPTS REQ`D PER 210-52E | | | | | | 3} PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE OR NOTE ON PLANS FOR BRANCH | | | CIRCUIT PROTECTION. PER 210-12 | | | | | | 4} PLEASE SHOW ALL OUTLET SPACING | | | TO MEET 2`,6`,12` RULE PER 210-52. | | | | | | 5} THE HALL SMOKE DETECTOR BETWEEN BED | | | ROOMS 2 & 3 MUST COMPLY WITH ARTICLE | | | 8-1.4.2 NFPA-72 (3' FROM KITCHEN DOOR | | | ETC.). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL; | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/659-8096 EXT. 8392 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-12 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-12 |
Time |
15:54 |
Sent To |
P |
|
| Notes |
| 2002-11-12 00:00:00 | TO "P" RES RACK./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-10-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-10-11 |
Time |
08:16 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2002-10-11 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2002-10-11 00:00:00 | PROVISO:MECHANICAL PERMIT 02100651 | | | | | | BALANCED RETURN AIR - 2001 FBC(M) 601.4 | | | RETURN AIR SHALL BE EQUAL TO SUPPLY | | | AIR BY MEANS OF AIR TRANSFER OR A RETURN | | | AIR (JUMPER).BEDROOMS SHALL HAVE R/A. | | | | | | CONDENSATE SHALL DISCHARGE A MINIMUM OF | | | 12" AWAY FROM THE BUILDING STRUCTURE AS | | | PER 2001 FBC 1503.4.4. | | | | | | BATHROOMS SHALL HAVE MECHANICAL EXHAUST | | | AS PER 2001 FBC(M) 402.3.1. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-10-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-12 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-10-11 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2002-12-02 |
|
|
Cont ID |
|
| Sent By |
lhatten |
Date |
2002-12-02 |
Time |
07:55 |
Rev Time |
1.00 |
| Received By |
lhatten |
Date |
2002-11-30 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2002-12-02 00:00:00 | SUBMITTED NEW PRODUCT APPR. & SPECIFIED | | | COLUMNS ECT. 11/30/2002 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2002-10-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-25 |
Time |
12:40 |
Rev Time |
2.00 |
| Received By |
lhatten |
Date |
2002-10-17 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2002-10-18 00:00:00 | 1) ALUMINUM FIXED WINDOW - PRODUCT | | | APPROVALS EXPIRED -- NEED NEW SETS (2) | | | | | | 2) FRONT ELEVATIONS - BOTH WINDOW & DOOR | | | NEED PRESSURES ( +,- ) | | | | | | 3) CLARIFY FRONT COLUMNS ROUND OR SQUARE | | | | | | 4) CLARIFY CONCRETE PADS AS TO SIZES IN | | | FRONT FOUNDATION PLAN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-10-10 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-10-10 |
Time |
16:39 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |