Plan Review Details - Permit 02100481
Plan Review Stops For Permit 02100481
Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2003-11-04 Cont ID  
Sent By hpiskura Date 2003-11-04 Time 15:11 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2003-11-04 00:00:00REVISIONS DATED 10/14/03 A1, A3, A4.

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2003-09-05 Cont ID  
Sent By hpiskura Date 2003-09-05 Time 11:28 Rev Time 0.00
Received By hpiskura Date 2003-09-05 Time 11:28 Sent To  
Notes
2003-09-05 00:00:00REVISION DATED 8/7/03

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2003-05-30 Cont ID  
Sent By hpiskura Date 2003-05-30 Time 16:31 Rev Time 0.00
Received By hpiskura Date 2003-05-30 Time 16:31 Sent To  
Notes
2003-05-30 00:00:00REVISION DATED 5/8/03 A1 & A2

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2003-03-26 Cont ID  
Sent By hpiskura Date 2003-03-26 Time 08:55 Rev Time 0.00
Received By hpiskura Date 2003-03-26 Time 08:42 Sent To FIRE
Notes
2003-03-26 00:00:00THE PLANS SUBMITTED FOR REVISION ARE NOT
 SIGNED, SEALED AND DATED BY THE
 ARCHITECT.FBC 104.2.2.
  
 SHEET A2.THE DOORS ARE NOT PERMITTED
 TO SWING OVER THE PUBLIC RIGHT OF WAY.
 FBC 3203.
  
 THE FOAM TRIM DEPICTED ON SHEETA3 IS
 REQUIRED TO BE NON-COMBUSTIBLE ARE FIRE
 RETARDANT TREATED.SEE FBC F 102.2.7
 AS AMENDED BY THE CITY.
  
 PLEASE PAY THE ADDED PERMIT VALUATION
 FOR THE ADDITIONAL WORK SHOWN AS A
 RATED TENANT SEPARATION WALL AND TOILET
 ROOM.
  
 PLEASE CLEARLY INDICATE THE MOST RECENT
 REVISIONS IN ACCORDANCE WITH GOOD
 ARCHITECTURAL PRACTICE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-02-20 Cont ID  
Sent By sthyng Date 2003-03-24 Time 14:47 Rev Time 0.00
Received By hpiskura Date 2003-02-20 Time 15:18 Sent To  
Notes
2003-02-20 00:00:00REVISION DATED 2/13/03

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-02-12 Cont ID  
Sent By dpalmer Date 2003-02-18 Time 15:40 Rev Time 0.00
Received By hpiskura Date 2003-02-11 Time 15:49 Sent To FIRE
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-01-07 Cont ID  
Sent By sgraham Date 2003-02-05 Time 15:08 Rev Time 0.00
Received By hpiskura Date 2002-12-12 Time 16:36 Sent To  
Notes
2003-01-07 00:00:00PROVISO: FIRE RETARDANT TREATED PLYWOOD
 TO BE USED IN EXTERIOR PARAPET
 CONSTRUCTION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-10-29 Cont ID  
Sent By jwitmer Date 2002-10-29 Time 11:21 Rev Time 2.25
Received By jwitmer Date   Time   Sent To  
Notes
2002-10-29 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02100481
 ADD: 3300 S DIXIE HWY
 CONT: TROPICAL CONCRETE RESTORATION
 TEL: (561)848-4767
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 NOTE: FIRE DISTRICT, BLDG TO COMPLY WITH
 APPENDIX F.
  
 1) SHEET A-3,4 & 5, CROSS SECTION
 THROUGH FRONT WALL NEW DECORATIVE ELE-
 MENT, F 102.2.7 ARCHITECTURAL TRIM ON
 BUILDINGS LOCATED IN A FIRE DISTRICT
 SHALL BE CONSTRUCTED OFAPPROVED NONCOM-
 BUSTIBLE MATERIALS OR FIRE RETARDANT
 TREATED WOOD.
  
 2) CANVAS AWNINGS REQUIE A SEPERATE PER-
 MIT. F102.2.8(1) ANY TEXTILE COVERING
 FOR THE CANOPY SHALL BE FLAME RESISTANT
 AS DETERMINED IN ACCORDANCE WITH 3103.1
 3103.1 CERTIFICATION OF FLAME
 RESISTANCE, NFPA 701.
 3204.3 CLEARENCE, EVERY FIXED AWNING
 SHALL BE A LEAST 8"-0" IN THE CLEAR
 BETWEEN THE LOWEST FRAMING MEMBER AND A
 SIDEWALK BELOW.
  
 3)704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 4)705.7.1 JOINTS INSTALLED IN OR BE-
 TWEEN FIRE RESISTANT WALLS, FIRE RESIS-
 TANT FLOORS OR FLOOR/ CEILING ASSEMBLIES
 AND FIRE RESISTANT ROOFS OR ROOF/ CEIL-
 ING ASSEMBLIES SHALL BE PROTECTED BY AN
 APPROVED FIRE RESISTANT JOINT SYSTEM
 DESIGNED TO RESIST THE PASSAGE OF FIRE
 FOR A PERIOD NOT LESS THAN THE RE-
 QUIRED FIRE RESISTANCE RATING OF THE
 WALL, FLOOR OR FLOOR IN OR BETWEEN
 WHICH IT IS INSTALLED.
  
 5)705.1.2 PENETRATIONS SHALL BE PRO-
 TECTED BY AN APPROVED PENETRATION FIRE-
 STOP SYSTEM AS TESTED IN ACCORDANCE WITH
 ASTM E 814, WITH A MINIMUM POSITIVE
 PRESSURE DIFFERENTIAL OF 0.01 INCH OF
 WATER COLUMN AND AN F RATING OF NOT LESS
 THAN REQUIRED RATING OF THE WALL
 PENETRATED.
  
 6)1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
  
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST.
  
 7) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING REPORTS:
 A) WINDOWS
 B) MULLIONS
 C) DOORS
 D) STORM SHUTTERS
  
 8) PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
  
 9)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 10) 1606.4.4 ANCHOR METHODS. PROVIDE
 INFORMATION FOR INSTALLATION OF DOOR
 AND WINDOW BUCKS.
  
 11) 1707.4.4.1 ANCHOR REQUIREMENTS:
 WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR
 ED IN ACCORDANCE WITH THE PUBLISHED
 MANUFACTURER'S RECOMMENDATIONS TO
 ACHIEVE THEDESIGN PRESSURE SPECIFIED.
 SUBSTITUTE ANCHORING SYSTEM USED FOR
 THE SUBSTRATE NOT SPECIFIED BY THE
 FENESTRATION MANUFACTURER SHALL PROVIDE
 EQUAL OR GREATER ANCHORING AS DEMONSTRA-
 TED BY ACCEPTED ENGINEERING PRACTICES.
  
 12) 1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
 13) 1707.4.5.2 MULLIONS SHALL BE DESIGN-
 ED TO TRANSFER THE DESIGN PRESSURE LOADS
 APPLIED BY THE WINDOW OR DOOR ASSEMBLIES
 TO THE ROUGH OPENING SUBTRATE.
  
 14)1503.4 ROOF DRAINS UNLESS ROOFS ARE
 SLOPED TO DRAIN OVER THE ROOF EDGE, ROOF
 DRAINS SHALL BE INSTALLED AT THE LOWEST
 POINT OF THE ROOF. WHERE REQUIRED FOR
 ROOF DRAINAGE,SCUPPERS SHALL BE LOCATED
 AS DETERMINED BY THE ROOF SLOPE AND CON-
 TRIBUTING ROOF AREA.
  
 15)1503.4.2 OVERFLOW DRAINS SHALL BE
 THE SAME SIZE AS ROOF DRAINS, INSTALLED
 WITH THE INLET FLOW LINE LOCATED 2"
 ABOVE THE LOWEST POINT OF THE ROOF LINE.
 OVERFLOW SCUPPERS SHALL BE A MINIMUM OF
 4"IN HEIGTH AND SHALL BE PLACED IN WALLS
 OR PARARETS WITH THE INLET FLOW LINE
 NOT LESS THAN 2" ABOVE THE ROOF SURFACE.
  
 16) 1503.4.4 PROTECTION AGAINST DECAY &
 TERMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 17)1511.7 ROOF MOUNTED MECHANICAL UNIT
 S SHALL BE MOUNTED ON CURBS RAISED A
 MINIMUM OF 8 INCHES ABOVE THE ROOF SUR-
 FACE, OR WHERE ROOFING MATERIALS EXTEND
 BENEATH THE UNIT, ON RAISED EQUIPMENT
 SUPPORTS PROVIDING A MINIMUM CLEARENCE
 HEIGTH IN ACCORDANCE WITH TABLE 1511.7.
  
 18)PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2003-11-06 Cont ID  
Sent By dpalmer Date 2003-11-06 Time 14:32 Rev Time 0.50
Received By dpalmer Date 2003-11-06 Time 14:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2003-10-14 Cont ID  
Sent By csiegber Date 2003-11-05 Time 15:59 Rev Time 0.33
Received By dpalmer Date 2003-10-14 Time 17:38 Sent To  
Notes
2003-10-14 00:00:00*********** UNSAT **************
  
 1)NOTE: PLEASE SHOW ALL CIRCUITING ON
 PLANS AND CORRELATE WITH A SUBMITTED
 PANEL SCHEDULE. PLEASE SEE SOME CIRCUIT
 #S SEEM TO HAVE BEEN MISPRINTED.
 A'S-B'S.
 PLEASE ALSO SEE 700.12E FOR CIRCUITING
 OF EM/EXT LTS.SEE UNIT 2&4.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2003-09-10 Cont ID  
Sent By dpalmer Date 2003-09-10 Time 11:17 Rev Time 0.33
Received By dpalmer Date 2003-09-10 Time 11:17 Sent To  
Notes
2003-09-10 00:00:00************ UNSAT ****************
  
 1)NOTE; PLEASE SEE THAT HAND DRAWN
 CHANGES ARE NOTE PERMITTED ON PLANS THAT
 ARE SIGNED, DATED AND SEALED BY THE
 ARCH/ENGINEER OF RECORD. REQ'D UNDER
 FS 471/481.
 PLEASE HAVE ENGINEER OF RECORD MAKE ANY
 CHANGES.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-02-07 Cont ID  
Sent By dpalmer Date 2003-02-07 Time 16:53 Rev Time 0.50
Received By dpalmer Date 2003-02-07 Time 16:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2002-11-20 Cont ID  
Sent By dpalmer Date 2002-11-20 Time 06:49 Rev Time 1.00
Received By dpalmer Date 2002-11-20 Time 06:49 Sent To  
Notes
2002-11-20 00:00:00***************** UNSAT *************
  
 1)NOTE: PLEASE NOTE IN RESPONSE LETTER,
 NOTE#2 MENTIONS MAIN DISC`S HAVE BEEN
 REVISED. PLEASE NOTE THAT DISC`S ARE THE
 SAME AS BEFORE AND ALL LOAD CALCULATIONS
 HAVE BEEN REVISED. PLEASE NOTE LOAD
 HAVE NOW BEEN CUT IN HALF OF PREVIOUS
 LOADS.
 PLEASE SHOW LOAD CALCUALTIONS PER NEC
 220-3,220-10,220-11,220-13 AND CONTINU-
 -UOS LOADS PER 215-3,230-42.
  
 2)NOTE:PLEASE NOTE, A/C HEAT-STRIP ARE
 NOW SHOWN AT 7.5KW AND STILL SHOWN AS
 10KW ON MECH PLANS? PLEASE CORRELATE.
 PLEASE SEE MAX OCP FOR 7.5KW.
  
 3)NOTE: PLEASE NOTE, PANEL SCHEDULES
 ARE SHOWING THE REQ`D SIGN CIRCUIT PER
 600-5, BUT PLEASE SHOW LOCATION ON PLAN.
  
 4)NOTE: PLEASE NOTE, CIRCUITING IS NOW
 SHOWN, PLEASE SEE 700-12E FOR CIRCUITING
 OF EM LTS AND EX LTS.
  
 5)NOTE: PLEASE NOTE, PANEL SCHEDULE BAR
 SHOWS PANELS AS BEING MCB AND RISER SHOW
 S A TYPICAL AS MLO.? PLEASE CORRELATE.
  
 6)NOTE: PLEASE SEE 210-62 FOR LOCATION
 OF SHOW WINDOW RECEPT.
  
 7)NOTE: PLEASE CLARIFY CIRCUTIS 6&8 FOR
 PANEL "A", SHOWN AS GFI?
 PLEASE ALSO CLARIFY AND CORRELATE ALL
 CIRCUITING ON PLANS WITH PANEL SCHEDULE
 PLEASE SEE PANEL, CIRCUITS SHOWN BUT
 NOT ON PLANS.
 PLEASE CLARIFY LT CIRCUIT ON SIDE OF
 BLDG. EACH LT COMING FROM A DIFFERENT
 UNIT? THIS A JUST A NOTE,
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-11-20 Cont ID  
Sent By dpalmer Date 2002-10-15 Time 08:50 Rev Time 0.50
Received By dpalmer Date 2002-10-15 Time 08:50 Sent To  
Notes
2002-10-15 00:00:00*************** UNSAT ******************
  
 1)NOTE: PLEASENOTE, NO SERVICE
 CONDUCTORS FROM GUTTER TO METER, METER
 TO MAINS.215-5
  
 2)NOTE: PLEASE NOTE, ALL MAIN DISC`S ARE
 SHOWN AS 125A WITH LOADS EXCEEDING
 RATINGS OF MAINS? 134,133,149 ETC.
  
  
 3)NOTE: PLEASE NOTE, ALL CONTINUOUS
 LOADS ARE TO BE SHOWN AT 125%. 215-3,230
 -42.
  
 4)NOTE: PLEASE SHOW CIRCUIT #`S ON PLANS
 AND CORRELATE WITH SUBMITTED PANEL
 SCHEDULES.
  
 5)NOTE: PLEASE SEE FIRE REVIEW COMMENTS,
 SHOW EITHER NEW OR EXISTING EMERGENCY
 LTS/ EXIT LTS. 700-12
  
 6)NOTE: PLEASE SHOW LOCATIONS OF PANELS
 ON PLANS.
  
 PLEASE SUBMIT THE ABOVCE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUETIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 6 Status P Date 2003-10-30 Cont ID  
Sent By mcarsill Date 2003-10-30 Time 06:51 Rev Time 0.00
Received By mcarsill Date 2003-10-30 Time 06:51 Sent To  
Notes
2003-10-30 00:00:001) BUILDING ADDRESS REQUIRED.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2003-06-09 Cont ID  
Sent By nmccray Date 2003-06-09 Time 11:02 Rev Time 0.00
Received By nmccray Date 2003-06-09 Time 11:02 Sent To  
Notes
2003-06-09 00:00:00REVISION A-2 & A-3 SUBMITTED ON 5-16-03

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status F Date 2003-04-01 Cont ID  
Sent By nmccray Date 2003-04-01 Time 13:49 Rev Time 0.00
Received By nmccray Date 2003-04-01 Time 13:49 Sent To  
Notes
2003-04-01 00:00:001) PLEASE PROVIDE CLEAR DEFINE REVISION
 TO LIFE SAFETY PLAN FOR REVIEW.
  
 2) ALSO SEE BUILDING REVEIW COMMENTS.
  
 NATE MCCRAY, CAPTAIN
 659-8096, EXT 8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2003-02-13 Cont ID  
Sent By hpiskura Date 2003-03-26 Time 09:14 Rev Time 0.00
Received By nmccray Date 2003-02-13 Time 10:09 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-11-15 Cont ID  
Sent By mcarsill Date 2002-11-15 Time 13:57 Rev Time 0.00
Received By mcarsill Date 2002-11-15 Time 13:57 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-11-01 Cont ID  
Sent By mcarsill Date 2002-11-01 Time 17:32 Rev Time 0.00
Received By mcarsill Date 2002-11-01 Time 17:32 Sent To  
Notes
2002-11-01 00:00:001) BUILDING IS LOCATED IN THE CITY FIRE
 LIMITS. COMPLIANCE REQUIRED WITH
 APPENDIX F OF THE LOCAL AMENDMENTS TO
 THE FLORIDA BUILDING CODE.
  
 2) BUILDING ADDRESS REQUIRED.
  
 3) NO ILLUMINATED EXIT SIGNS OR
 ILLUMINATED EXIT SIGNS SHOWN ON PLANS.
  
 4) PLEASE CLEARLY DEMONSTRATE EXIT
 DISCHARGE REQUIREMENTS IN THE REAR
 OF THE BUILDING.
  
 5) PLEASE PROVIDE UL NUMBERS FOR RATED
 WALLS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2003-11-05 Cont ID  
Sent By csiegber Date 2003-11-05 Time 16:00 Rev Time 0.00
Received By csiegber Date 2003-11-05 Time 16:00 Sent To Z
Notes
2003-11-05 00:00:00TO Z/REV LANDSCAPING

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2003-11-05 Cont ID  
Sent By csiegber Date 2003-11-05 Time 15:59 Rev Time 0.00
Received By csiegber Date 2003-11-05 Time 15:59 Sent To E
Notes
2003-11-05 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2003-10-14 Cont ID  
Sent By csiegber Date 2003-10-14 Time 16:32 Rev Time 0.00
Received By csiegber Date 2003-10-14 Time 16:32 Sent To  
Notes
2003-10-14 00:00:00TO COMM BD#18

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2003-09-03 Cont ID  
Sent By csiegber Date 2003-09-03 Time 12:01 Rev Time 0.00
Received By csiegber Date 2003-09-03 Time 12:01 Sent To  
Notes
2003-09-03 00:00:00ON COMM BD #13

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2003-09-02 Cont ID  
Sent By csiegber Date 2003-09-02 Time 11:21 Rev Time 0.00
Received By csiegber Date 2003-09-02 Time 11:22 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2003-06-26 Cont ID  
Sent By shernand Date 2003-06-26 Time 08:34 Rev Time 0.00
Received By shernand Date 2003-06-26 Time 08:34 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2003-05-19 Cont ID  
Sent By shernand Date 2003-05-19 Time 09:23 Rev Time 0.00
Received By shernand Date 2003-05-19 Time 09:23 Sent To  
Notes
2003-05-19 00:00:00COMM BOARD #5

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-03-24 Cont ID  
Sent By sthyng Date 2003-03-24 Time 14:44 Rev Time 0.00
Received By sthyng Date 2003-03-24 Time 14:44 Sent To B
Notes
2003-03-24 00:00:00TO HP DESK

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-02-18 Cont ID  
Sent By dpalmer Date 2003-02-18 Time 15:40 Rev Time 0.00
Received By dpalmer Date 2003-02-18 Time 15:40 Sent To B
Notes
2003-02-18 00:00:00TO HHP"S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-02-06 Cont ID  
Sent By dpalmer Date 2003-02-06 Time 15:56 Rev Time 0.00
Received By dpalmer Date 2003-02-06 Time 15:56 Sent To  
Notes
2003-02-06 00:00:00TO COMM BOARD #56

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-01-30 Cont ID  
Sent By dpalmer Date 2003-01-30 Time 13:46 Rev Time 0.00
Received By dpalmer Date 2003-01-30 Time 13:46 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-08 Cont ID  
Sent By dpalmer Date 2003-01-08 Time 09:39 Rev Time 0.50
Received By dpalmer Date 2003-01-08 Time 09:39 Sent To  
Notes
2003-01-08 00:00:00PLANS BACK FROM ZONING 12/20, LEFT IN
 #35, CALLED FOR PICK UP.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-15 Cont ID  
Sent By dpalmer Date 2002-11-15 Time 12:05 Rev Time 0.00
Received By dpalmer Date 2002-11-15 Time 12:05 Sent To  
Notes
2002-11-15 00:00:00TO COMM BOARD #35

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-07-02 Cont ID  
Sent By csiegber Date 2003-09-02 Time 11:22 Rev Time 0.40
Received By pkrauss Date 2003-07-02 Time 07:20 Sent To  
Notes
2003-07-02 00:00:00REVISION SUBMITTED ARE SHOP DRAWINGS.
 ORIGINAL PLANS WHERE INADVERTENTLY
 STAMPED BY THE STRUCTURAL ENGINEER (NO
 TITLE BLOCK ON MECH PLAN) AS PER
 HAROLD MOSER SHOP DRAWINGS WILL BE
 ACCEPTABLE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-11-27 Cont ID  
Sent By shernand Date 2003-06-26 Time 08:34 Rev Time 0.40
Received By pkrauss Date 2002-11-27 Time 10:13 Sent To  
Notes
2002-11-27 00:00:00PROVISO:MECHANICAL PERMIT 02100483
  
 C.U. STANDS ON ROOF SHALL COMPLY WITH
 2001 FBC TABLE 1511.7.
  
 AS PER 2001 FBC(M) 306.5, EQUIPMENT
 LOCATED ON THE ROOF WITH THE HEIGHT
 EXCEEDING 16 FT SHALL HAVE A PERMANENT
 MEANS OF ACCESS.SUCH ACCESS SHALL NOT
 REQUIRE CLIMBING OVER OBSTRUCTIONS
 GREATER THAN 30".
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status I Date 2002-11-04 Cont ID  
Sent By pkrauss Date 2002-11-04 Time 08:25 Rev Time 0.35
Received By pkrauss Date 2002-11-04 Time 08:21 Sent To  
Notes
2002-11-04 00:00:00INSUFFICIENT INFORMATION -
  
 MECHANICAL PERMIT 02100483
 PLEASE PROVIDE DUCT LAYOUT FOR EACH
 SPACE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 5 Status N Date 2003-10-21 Cont ID  
Sent By kstevens Date 2003-10-21 Time 17:00 Rev Time 0.25
Received By kstevens Date 2003-10-21 Time 17:00 Sent To  
Notes
2003-10-21 00:00:00NO PLUMBING REVISION SHOWN

Review Stop P PLUMBING
Rev No 4 Status P Date 2003-10-02 Cont ID  
Sent By kstevens Date 2003-10-02 Time 15:30 Rev Time 0.50
Received By kstevens Date 2003-10-02 Time 15:30 Sent To  
Notes
2003-10-02 00:00:00AS BUILTS - OK

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-02-07 Cont ID  
Sent By kstevens Date 2003-02-07 Time 14:07 Rev Time 0.50
Received By kstevens Date 2003-02-07 Time 14:07 Sent To  
Notes
2003-02-07 00:00:00PASSED/PROVISO
  
 MANUFACTURE INFORMATION REQUIRED FOR
 FINAL INSPECTION - ARI-1010 COMPLIANCE
 REQUIRED

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-12-10 Cont ID  
Sent By kstevens Date 2002-12-10 Time 14:05 Rev Time 1.00
Received By kstevens Date 2002-12-10 Time 14:04 Sent To  
Notes
2002-12-10 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) SHT A-5 PLEASE SHOW A HORIZONTAL
 RISER DIAGRAM SHOWING ALL NEW BATHROOMS
 AND HOW THEY TIE INTO THE BLDG DRAIN.
 2) SHT A-5 PREVIOUS REVIEW REQUESTED A
 WATER RISER DIAGRAM. PLEASE SUBMIT RISER
 WITH WATER HAMMER ARRESTORS REQUIRED BY
 SECTION 604.9 NEAR FIXTURES NOT AT TOP
 OF DROP.
 3) SHOW LOCATION OF WATER FOUNTAINS ON
 FLOOR PLAN AND ON BOTH RISERS. ALSO SEE
 SECTION 410.1, IF WATER COOLERS ARE BE-
 ING USED THEY SHALL BE ARI-1010 COMPLI-
 ANT. SUBMIT MANUF. INFO.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-11-02 Cont ID  
Sent By kstevens Date 2002-11-02 Time 13:49 Rev Time 1.00
Received By kstevens Date 2002-11-02 Time 13:49 Sent To  
Notes
2002-11-02 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) MORE INFORMATION REQUIRED. ARE THE
 TOILET ROOMS EXISTING? IF NOT A SANITARY
 AND A WATER RISER DIAGRAM IS REQUIRED.
 2) TABLE 403.1 REQUIRES A DRINKING
 FOUNTAIN IN EACH SPACE. ALSO SEE SECTION
 410.1.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 2 Status P Date 2003-02-05 Cont ID  
Sent By csiegber Date 2003-11-05 Time 16:00 Rev Time 0.00
Received By sgraham Date   Time   Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-12-20 Cont ID  
Sent By dpalmer Date 2003-01-30 Time 13:46 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-12-20 00:00:00DENIED
 1. PROVIDE A SURVEY OF THE PROPERTY
 THAT IS LESS THAN A YEAR AGO(PER 9-30-02
 SITE PALN APPROVAL LTR
 2.A BULNESIA ARBOREA TREE IS REQUIRED
 IN THE LANDSCAPE AREA ADJACENT TO THE
 DISABLED SPACE
 3THE APPROVAL ELEVATIONS (PER 9-30-02
 SITE PLAN APPROVAL LTR) CONTAINS AWNINGS
 ABOVE THE FOUR ENTRANCES ON THE WEST
 THESE WERE REMOVED AS PART OF THE RESUBM
 ITTED PLANS DUE TO PLAN VIEW COMMENTS
 THE COMMENT REQUIRED THAT THE AWNINGS
 HAVE EIGHT FEET OF CLEARANCE AND BE
 SUBMITTED UNDER A SEPARATE PERMIT.
 ZONING WILL NOT APPROVE THIS PERMIT WITH
 OUT THE CONCURRENT SUBMISSION OF A
 PERMIT FOR THE AWNINGS, MEETING ALL
 APPLICABLE CODES. ZONING WILL NOT ISSUE
 1 C/O WITHOUT THE AWNING INSTALLED,
 MEETING ALL APPLICABLE CODES