Plan Review Details - Permit 02100473
| Plan Review Stops For Permit 02100473 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-10-29 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-10-29 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-10-29 |
Time |
11:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-10-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-10-10 |
Time |
08:36 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2002-10-10 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2002-10-10 00:00:00 | ************* UNSAT *************** | | | | | | 1)NOTE: PLEASE NOTE PLANS/480V ARE REQ`D | | | TO BE DONE BY AN ENGINEER FBC 104.4.1.3, | | | FS 553-79-6, 471.003. | | | | | | | | | 2)NOTE: PLEASE NOTE PLANS ARE SHOWING | | | A COMPLETE NEW SERVICE. PLEASE CLARIFY | | | LOCATION AND OR IF EXISTING SERVICE IS | | | BEING REMOVED? | | | | | | 3)NOTE: PLEASE NOTE VOLTAGE ON TRANS- | | | -FORMER SHOWN AT 408V? | | | | | | 4)NOTE: PLEASE NOTE MISSING EQUIPMENT | | | GROUNDING CONDUCTORS. TABLE 250-122 | | | | | | 5)NOTE:PLEASE SHOW GROUNDING FOR TRANS- | | | -FORMERS PER 250-50 | | | | | | 6)NOTE: PLEASE NOTE ALL CIRCUITING NEEDS | | | TO BE ON PLANS AND CORRELATE W/ PANEL | | | SCHEDULES. | | | | | | 7)NOTE: PLEASE NOTE MISSING DETAIL FOR | | | GROUNDING ELECTRODE SYSTEM. | | | | | | 8)NOTE: PLEASE SEE FIRE REVIEW COMMENTS, | | | PLEASE NOTE 700-12 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-10-08 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-10-08 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-10-08 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2002-10-08 00:00:00 | 1) ALL WORK TO COMPLY WITH LIFE SAFETY | | | CODE, NFPA 101 2000 EDITION. | | | | | | 2) PLEASE INDICATE THE LOCATION OF EXIT | | | SIGNS AND EMERGENCY LIGHTING. | | | | | | 3) BUILDING FIRE PROTECTION EQUIPMENT TO | | | REMAIN OPERABLE DURING DEMOLITION AND | | | CONSTRUCTION. | | | | | | 4) DEMOLITION DEBRIS TO REMOVED DAILY. | | | | | | 5) PLEASE INDICATE THE TYPE OF INTERIOR | | | FINISH. | | | | | | | | | MIKE WENNERGREN, ACTING CAPTAIN | | | 659-8096, EXT. 8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-10-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-10-29 |
Time |
11:22 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2002-10-29 |
Time |
10:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-10-28 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2002-10-28 |
Time |
09:57 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-10-28 00:00:00 | PLUMBING PLAN REVIEW, FBC 2001, DENIED. | | | (1) SHT 3 & 5 | | | SHOW H/C DETAILS WITH ELIVATIONS AND | | | DIMENSIONS OF BREAK ROOM SINK, WATER | | | COOLER, DRESSING ROOM WITH BENCH AND | | | CLEAR FLOOR SPACE, SEC 104.3 | | | (2) SHT P-1 | | | PROVIDE A ISOMETRIC DRAWING OF WATER | | | PIPING, LIST TYPE OF MATERIAL, LOCATION | | | AND TYPE OF WATER HAMMER ARRESTOR IF | | | USED. SEC 104.3 | | | END OF COMMENTSPAUL SCHMITZ | | | QUESTIONS561-659-8096X8233 |
|
|
|