| Plan Review Stops For Permit 02100324 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-08-07 |
Time |
16:09 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2003-08-07 |
Time |
16:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-07-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-07-14 |
Time |
11:07 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2003-07-14 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2003-07-14 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 02100324 | | | ADD: 5400 EAST AV | | | CONT: CATALFUMO | | | TEL: (561)307-4836 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | REVISION# 2 | | | ACTION: DENIED | | | | | | 1) AWNING: W.P.B. ADMINISTRATIVE CODE | | | 104.1.1 SEPERATE PERMIT IS REQUIRED FOR | | | AWNINGS. | | | | | | 2) AWNING: 2003.7 TO BE DESIGNED BY A | | | FL REGISTERED PROFESSIONAL ENGINEER. | | | | | | 3) NEW DOOR AND WINDOW OPENINGS, MISSING | | | PRODUCT INFORMATION: | | | FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORT, SBCCI OR DADE COUNTY | | | REPORT ARE ACCEPTED. | | | | | | 4) NO INFORMATION ON THE NEW OPENINGS, | | | PLANS DO NOT INDICATE FILLED CELL AT | | | OPENINGS? 104.2.2.WHAT IS THE DROPPED | | | HEADER OVER THE NEW OPENINGS MADE OF? | | | HOW IS IT SUPPORTED? | | | | | | 5) 1707.4.4.2 TAPERED BUCKS: | | | SHALL EXTEND BEYOND THE INTERIOR FACE | | | OF THE WINDOW OR DOOR FRAME SUCH THAT | | | FULL SUPPORT OF THE FRAME IS SUPPORTED. | | | | | | 6)THE VALUE OF THE PROJECT HAS INCREASED | | | HOW MUCH? PERMIT VALUES SHOULD ALSO | | | REFLECT THE INCREASE IN THE PROJECT. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-03-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-03-04 |
Time |
10:38 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2003-03-04 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-10-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-10-22 |
Time |
15:50 |
Rev Time |
3.00 |
| Received By |
jwitmer |
Date |
2002-10-22 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2002-10-22 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 02100324 | | | ADD: 5400 EAST AVENUE | | | CONT: CATALFUMO | | | TEL: (561)694-3000 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1) 11.4.1.6 ACCESSIBLE BUILDINGS: | | | ALTERATIONS,(B) IF EXISTING ELEMENTS, | | | SPACES, OR COMMON AREAS ARE ALTERED, | | | THEN EACHSUCH ALTERED ELEMENT, SPACE,FEA | | | TURE OR AREA SHALL COMPLY WITH THE | | | APPLICABLE PROVISIONS OF 11-4.1.1 TO | | | 11-4.1.3. | | | 11-4.1.3(11) TOILET FACILITIES, | | | IF TOILET ROOMS ARE PROVIDED, THEN EACH | | | PUBLIC AND COMMON USE TOLIET ROOM SHALL | | | COMPLY WITH 11-4.22. | | | 11-4.22.2(1) ALL DOORS TO ACCESSIBLE | | | TOILET ROOMS SHALL COMPLY WITH 11-4.13. | | | DOORS SHALL NOT SWING INTO CLEAR FLOOR | | | SPACE REQUIRED FOR ANY FIXTTURE. | | | DOORS 9A, 35 & 36 ARE IN NON-COMPLI- | | | ANCE. | | | | | | 2) TOILET STALLS SEE FIGURE 30 "E". | | | | | | 3)SEE 11-6(1) DETOXIFICATION FACILITIES, | | | OR 11-9 ACCESSIBLE TRANSIENT LODGING | | | (DORMITORIES). | | | | | | 4) 11-9.1.3 SLEEPING ACCOMMANDATIONS FOR | | | PERSONS WITH HEARING IMPAIRMENTS. | | | | | | 5) 11-9.3 VISUAL ALARMS, NOTIFICATION | | | DEVICES AND TELEPHONE. | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDEN- | | | TIFYING THE SHEET OR SPECIFICATION PAGE | | | WHERE THE CHANGES CAN BE FOUND, WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | JIM WITMER | | | PLAN REVIEW | | | TEL: (561)659-8096 EX.8412 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-08-04 |
Time |
16:16 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-08-04 |
Time |
16:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-07-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-03 |
Time |
11:29 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-07-03 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-02-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-24 |
Time |
06:14 |
Rev Time |
0.15 |
| Received By |
dpalmer |
Date |
2003-02-24 |
Time |
06:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-10-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-10-08 |
Time |
18:49 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2002-10-08 |
Time |
18:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2003-08-11 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-08-11 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-08-11 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2003-08-11 00:00:00 | REVISION DATED 7-23-03 NAM |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-07-09 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-07-09 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2003-07-09 00:00:00 | REVISION 06-23-03 NAM |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-03-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-03-04 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2003-03-04 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2003-03-04 00:00:00 | OK PER MEC SUBMITTAL FORMJW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2002-10-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-10-04 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-10-04 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-07-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-24 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-24 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2003-07-24 00:00:00 | COMM IN BOX #49ALANGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-23 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-23 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-23 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2003-06-23 00:00:00 | COMM BOARD #8 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-02-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-11 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-11 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2003-02-11 00:00:00 | TO COMM BOARD #20 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2003-07-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-07-28 |
Time |
15:38 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2003-07-28 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2003-07-28 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR | | | REVISION |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-02-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-20 |
Time |
08:29 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-02-20 |
Time |
08:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-10-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-10-29 |
Time |
09:48 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2002-10-29 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2002-10-29 00:00:00 | PROVISO: | | | | | | FIRE DAMPERS SHALL COMPLY WITH THE | | | REQUIREMENTS OF UL 555.PROVIDE | | | MANUFACUTURER SUBMITTAL AND | | | INSTALLATION INSTRUCTIONS ON THE | | | JOBSITE AT THE TIME OF INSPECTION. | | | 2001 FBC(M) 607.1.1 & 607.6. | | | | | | NO COMBUSTIBLES ABOVE THE CEILING IN THE | | | RETURN AIR PLENUM.2001 FBC(M) | | | 602.1.1. | | | | | | PLANS DO NOT INDICATE DUCT SMOKE | | | DETECTORS.AS PER 2001 FBC(M) 606.2.1, | | | SMOKE DETECTORS SHALL BE INSTALLED IN | | | SUPPLY AIR SYSTEMS WITH A DESIGN | | | CAPACITY GREATER THAN 2,000 CFM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2003-08-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-08-11 |
Time |
18:06 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-08-11 |
Time |
18:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2003-07-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-05 |
Time |
12:22 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-07-05 |
Time |
12:22 |
Sent To |
|
|
| Notes |
| 2003-07-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A-1 SINK IN CONFERENCE ROOM SHALL | | | COMPLY WITH 11-4.24 AND ALL SUBSECTIONS | | | 2) SHT A-2 MANUF. INFORMATION REQUIRED | | | FOR EFFLUENT PUMP. MUST SHOW LISTING. | | | SECTION 303.4 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-03-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-04 |
Time |
11:20 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-03-04 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-10-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-10-28 |
Time |
13:38 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2002-10-28 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2002-10-28 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) SHT A-1 NEW RESTROOM,(W-108A), ADJAC- | | | ENT TO COFFEE ROOM SHALL COMPLY WITH SEC | | | 11-4.22 PER 11-4.1.3(11). MINIMUM WIDTH | | | REQUIRED IS 5'3", AND 5'0" IS SHOWN. | | | 2) SHT A-1 WOMENS, (W-114), HDCP STALL | | | MINIMUM WIDTH IS 5'3" AND 5'0" IS SHOWN. | | | 3) SHT A-1 DOORS SHALL NOT OPEN INTO THE | | | CLEAR FLOOR SPACE OR UNOBSTRUCTED 5' | | | TURNING RADIUS IN ROOMS W-125 & W-126. | | | 4) SHT A-2 PLUMBING NOTES, AIR CHAMBERS | | | ARE NOT APPROVED. PLEASE DELETE REFEREN- | | | CE. WATER HAMMER ARRESTORS ONLY REQUIRED | | | BY SEC. 604.9 SHALL BE INSTALLED. | | | 5) SHT A-2 SANITARY RISER DIAGRAM, FLOOR | | | DRAINS IN MEN'S AND WOMEN'S SHOWER AREA | | | ARE NOT VENTED. FLOOR DRAIN SHOWN IN | | | MEN'S REST ROOM W-126 IS NOT SHOWN ON | | | THE RISER DIAGRAM. | | | 6) WATER RISER DIAGRAM IS REQUIRED. IF | | | WATER HAMMER ARRESTORS ARE SHOWN, THEY | | | SHALL BE LOCATED NEAR THE FIXTURES IN AN | | | "EFFECTIVE RANGE" NOT OVERHEAD IN CEIL- | | | ING. | | | 7) SHT A-4 COFFEE ROOM SINK SHALL COMPLY | | | WITH 11-4.24 AND ALL SUBSECTIONS. PLEASE | | | SHOW ON DETAIL. | | | 8) TABLE 403.1 REQUIRES DRINKING FOUNT- | | | AINS AND A SERVICE SINK. PLEASE INDICATE | | | IF THESE FIXTURES ARE PROVIDED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-07-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-07-08 |
Time |
10:13 |
Rev Time |
1.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-07-08 00:00:00 | 7/8/03 PASS ZONIG REVIEW PER ANGELLA | | | VANN MM |
|
|