Plan Review Details - Permit 02100324
Plan Review Stops For Permit 02100324
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-08-07 Cont ID  
Sent By jwitmer Date 2003-08-07 Time 16:09 Rev Time 2.00
Received By jwitmer Date 2003-08-07 Time 16:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-07-14 Cont ID  
Sent By jwitmer Date 2003-07-14 Time 11:07 Rev Time 1.00
Received By jwitmer Date 2003-07-14 Time 11:07 Sent To  
Notes
2003-07-14 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02100324
 ADD: 5400 EAST AV
 CONT: CATALFUMO
 TEL: (561)307-4836
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 REVISION# 2
 ACTION: DENIED
  
 1) AWNING: W.P.B. ADMINISTRATIVE CODE
 104.1.1 SEPERATE PERMIT IS REQUIRED FOR
 AWNINGS.
  
 2) AWNING: 2003.7 TO BE DESIGNED BY A
 FL REGISTERED PROFESSIONAL ENGINEER.
  
 3) NEW DOOR AND WINDOW OPENINGS, MISSING
 PRODUCT INFORMATION:
 FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.
  
 4) NO INFORMATION ON THE NEW OPENINGS,
 PLANS DO NOT INDICATE FILLED CELL AT
 OPENINGS? 104.2.2.WHAT IS THE DROPPED
 HEADER OVER THE NEW OPENINGS MADE OF?
 HOW IS IT SUPPORTED?
  
 5) 1707.4.4.2 TAPERED BUCKS:
 SHALL EXTEND BEYOND THE INTERIOR FACE
 OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS SUPPORTED.
  
 6)THE VALUE OF THE PROJECT HAS INCREASED
 HOW MUCH? PERMIT VALUES SHOULD ALSO
 REFLECT THE INCREASE IN THE PROJECT.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-03-04 Cont ID  
Sent By jwitmer Date 2003-03-04 Time 10:38 Rev Time 0.75
Received By jwitmer Date 2003-03-04 Time 10:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-10-22 Cont ID  
Sent By jwitmer Date 2002-10-22 Time 15:50 Rev Time 3.00
Received By jwitmer Date 2002-10-22 Time 15:48 Sent To  
Notes
2002-10-22 00:00:00BUILDING PLAN REVIEW
 PERMIT: 02100324
 ADD: 5400 EAST AVENUE
 CONT: CATALFUMO
 TEL: (561)694-3000
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) 11.4.1.6 ACCESSIBLE BUILDINGS:
 ALTERATIONS,(B) IF EXISTING ELEMENTS,
 SPACES, OR COMMON AREAS ARE ALTERED,
 THEN EACHSUCH ALTERED ELEMENT, SPACE,FEA
 TURE OR AREA SHALL COMPLY WITH THE
 APPLICABLE PROVISIONS OF 11-4.1.1 TO
 11-4.1.3.
 11-4.1.3(11) TOILET FACILITIES,
 IF TOILET ROOMS ARE PROVIDED, THEN EACH
 PUBLIC AND COMMON USE TOLIET ROOM SHALL
 COMPLY WITH 11-4.22.
 11-4.22.2(1) ALL DOORS TO ACCESSIBLE
 TOILET ROOMS SHALL COMPLY WITH 11-4.13.
 DOORS SHALL NOT SWING INTO CLEAR FLOOR
 SPACE REQUIRED FOR ANY FIXTTURE.
 DOORS 9A, 35 & 36 ARE IN NON-COMPLI-
 ANCE.
  
 2) TOILET STALLS SEE FIGURE 30 "E".
  
 3)SEE 11-6(1) DETOXIFICATION FACILITIES,
 OR 11-9 ACCESSIBLE TRANSIENT LODGING
 (DORMITORIES).
  
 4) 11-9.1.3 SLEEPING ACCOMMANDATIONS FOR
 PERSONS WITH HEARING IMPAIRMENTS.
  
 5) 11-9.3 VISUAL ALARMS, NOTIFICATION
 DEVICES AND TELEPHONE.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-08-04 Cont ID  
Sent By dpalmer Date 2003-08-04 Time 16:16 Rev Time 0.50
Received By dpalmer Date 2003-08-04 Time 16:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-07-03 Cont ID  
Sent By dpalmer Date 2003-07-03 Time 11:29 Rev Time 0.33
Received By dpalmer Date 2003-07-03 Time 11:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-02-24 Cont ID  
Sent By dpalmer Date 2003-02-24 Time 06:14 Rev Time 0.15
Received By dpalmer Date 2003-02-24 Time 06:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-10-08 Cont ID  
Sent By dpalmer Date 2002-10-08 Time 18:49 Rev Time 0.50
Received By dpalmer Date 2002-10-08 Time 18:49 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2003-08-11 Cont ID  
Sent By nmccray Date 2003-08-11 Time 10:11 Rev Time 0.00
Received By nmccray Date 2003-08-11 Time 10:11 Sent To  
Notes
2003-08-11 00:00:00REVISION DATED 7-23-03 NAM

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2003-07-09 Cont ID  
Sent By nmccray Date 2003-07-09 Time 10:26 Rev Time 0.00
Received By nmccray Date 2003-07-09 Time 10:25 Sent To  
Notes
2003-07-09 00:00:00REVISION 06-23-03 NAM

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-03-04 Cont ID  
Sent By jwitmer Date 2003-03-04 Time 10:38 Rev Time 0.00
Received By jwitmer Date 2003-03-04 Time 10:38 Sent To  
Notes
2003-03-04 00:00:00OK PER MEC SUBMITTAL FORMJW

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-10-04 Cont ID  
Sent By mcarsill Date 2002-10-04 Time 15:10 Rev Time 0.00
Received By mcarsill Date 2002-10-04 Time 15:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-24 Cont ID  
Sent By alange Date 2003-07-24 Time 08:20 Rev Time 0.00
Received By alange Date 2003-07-24 Time 08:20 Sent To  
Notes
2003-07-24 00:00:00COMM IN BOX #49ALANGE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-23 Cont ID  
Sent By shernand Date 2003-06-23 Time 10:39 Rev Time 0.00
Received By shernand Date 2003-06-23 Time 10:39 Sent To  
Notes
2003-06-23 00:00:00COMM BOARD #8

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-11 Cont ID  
Sent By dpalmer Date 2003-02-11 Time 13:46 Rev Time 0.00
Received By dpalmer Date 2003-02-11 Time 13:46 Sent To  
Notes
2003-02-11 00:00:00TO COMM BOARD #20

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2003-07-28 Cont ID  
Sent By pkrauss Date 2003-07-28 Time 15:38 Rev Time 0.15
Received By pkrauss Date 2003-07-28 Time 15:35 Sent To  
Notes
2003-07-28 00:00:00NO MECHANICAL PLANS SUBMITTED FOR
 REVISION

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-02-20 Cont ID  
Sent By pkrauss Date 2003-02-20 Time 08:29 Rev Time 0.40
Received By pkrauss Date 2003-02-20 Time 08:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-10-29 Cont ID  
Sent By pkrauss Date 2002-10-29 Time 09:48 Rev Time 0.45
Received By pkrauss Date 2002-10-29 Time 09:31 Sent To  
Notes
2002-10-29 00:00:00PROVISO:
  
 FIRE DAMPERS SHALL COMPLY WITH THE
 REQUIREMENTS OF UL 555.PROVIDE
 MANUFACUTURER SUBMITTAL AND
 INSTALLATION INSTRUCTIONS ON THE
 JOBSITE AT THE TIME OF INSPECTION.
 2001 FBC(M) 607.1.1 & 607.6.
  
 NO COMBUSTIBLES ABOVE THE CEILING IN THE
 RETURN AIR PLENUM.2001 FBC(M)
 602.1.1.
  
 PLANS DO NOT INDICATE DUCT SMOKE
 DETECTORS.AS PER 2001 FBC(M) 606.2.1,
 SMOKE DETECTORS SHALL BE INSTALLED IN
 SUPPLY AIR SYSTEMS WITH A DESIGN
 CAPACITY GREATER THAN 2,000 CFM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 4 Status P Date 2003-08-11 Cont ID  
Sent By kstevens Date 2003-08-11 Time 18:06 Rev Time 1.00
Received By kstevens Date 2003-08-11 Time 18:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2003-07-05 Cont ID  
Sent By kstevens Date 2003-07-05 Time 12:22 Rev Time 0.50
Received By kstevens Date 2003-07-05 Time 12:22 Sent To  
Notes
2003-07-05 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) SHT A-1 SINK IN CONFERENCE ROOM SHALL
 COMPLY WITH 11-4.24 AND ALL SUBSECTIONS
 2) SHT A-2 MANUF. INFORMATION REQUIRED
 FOR EFFLUENT PUMP. MUST SHOW LISTING.
 SECTION 303.4
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-03-04 Cont ID  
Sent By kstevens Date 2003-03-04 Time 11:20 Rev Time 1.00
Received By kstevens Date 2003-03-04 Time 11:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-10-28 Cont ID  
Sent By kstevens Date 2002-10-28 Time 13:38 Rev Time 2.00
Received By kstevens Date 2002-10-28 Time 13:38 Sent To  
Notes
2002-10-28 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) SHT A-1 NEW RESTROOM,(W-108A), ADJAC-
 ENT TO COFFEE ROOM SHALL COMPLY WITH SEC
 11-4.22 PER 11-4.1.3(11). MINIMUM WIDTH
 REQUIRED IS 5'3", AND 5'0" IS SHOWN.
 2) SHT A-1 WOMENS, (W-114), HDCP STALL
 MINIMUM WIDTH IS 5'3" AND 5'0" IS SHOWN.
 3) SHT A-1 DOORS SHALL NOT OPEN INTO THE
 CLEAR FLOOR SPACE OR UNOBSTRUCTED 5'
 TURNING RADIUS IN ROOMS W-125 & W-126.
 4) SHT A-2 PLUMBING NOTES, AIR CHAMBERS
 ARE NOT APPROVED. PLEASE DELETE REFEREN-
 CE. WATER HAMMER ARRESTORS ONLY REQUIRED
 BY SEC. 604.9 SHALL BE INSTALLED.
 5) SHT A-2 SANITARY RISER DIAGRAM, FLOOR
 DRAINS IN MEN'S AND WOMEN'S SHOWER AREA
 ARE NOT VENTED. FLOOR DRAIN SHOWN IN
 MEN'S REST ROOM W-126 IS NOT SHOWN ON
 THE RISER DIAGRAM.
 6) WATER RISER DIAGRAM IS REQUIRED. IF
 WATER HAMMER ARRESTORS ARE SHOWN, THEY
 SHALL BE LOCATED NEAR THE FIXTURES IN AN
 "EFFECTIVE RANGE" NOT OVERHEAD IN CEIL-
 ING.
 7) SHT A-4 COFFEE ROOM SINK SHALL COMPLY
 WITH 11-4.24 AND ALL SUBSECTIONS. PLEASE
 SHOW ON DETAIL.
 8) TABLE 403.1 REQUIRES DRINKING FOUNT-
 AINS AND A SERVICE SINK. PLEASE INDICATE
 IF THESE FIXTURES ARE PROVIDED.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2003-07-08 Cont ID  
Sent By mmclean Date 2003-07-08 Time 10:13 Rev Time 1.00
Received By mmclean Date   Time   Sent To  
Notes
2003-07-08 00:00:007/8/03 PASS ZONIG REVIEW PER ANGELLA
 VANN MM