Plan Review Details - Permit 02100091
Plan Review Stops For Permit 02100091
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-11-13 Cont ID  
Sent By btrobaug Date 2002-10-31 Time 10:35 Rev Time 0.00
Received By rbrown Date 2002-11-13 Time 14:08 Sent To FIRE
Notes
2002-11-13 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 --BEFORE PERMIT--
 A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 --BEFORE PERMIT--
 THE PROPOSED WORK WILL INCREASE FLOOR
 AREA. IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 --PROVISO--
 FBC 3401.7.1.3DUE TO THE INCREASED FLR
 AREA, THE RELOCATED STORE FRONT SHALL
 CONFORM TO CURRENT CODE REQUIREMENTS.
 FBC 1012.1THE PLANS DO NOT STATE THE
 DOOR HARDWARE TYPE OR THE OCCUPANCY OF
 THE SPACE.THEREFOR, THE DOORS ARE
 ASSUMED TO BE EGRESS DOORS AND SHALL
 ONLY BE PERMITTED TO HAVE LOCKS/LATCHES
 WHICH ARE OPENABLE, USING ONE HAND,
 WITHOUT THE USE OF A KEY, TOOL OR
 SPECIAL KNOWLEDGE.
  
 --PROVISO--
 THE HEAD FASTENING ARRANGEMENT FOR THE
 METAL FLANGE STUD SHALL BE EQUIVALENT TO
 OR BETTER THAN THE EXISTING FASTENING
 ARRANGEMENT AT THE CURRENT LOCATION.
 ALTERNATIVELY, STATE THE WIND PRESSURES
 ON THE PLANS FOR VERIFICATION OF THE
 PROPOSED FASTENINGS.

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2002-10-16 Cont ID  
Sent By dpalmer Date 2002-10-16 Time 09:24 Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
2002-10-15 00:00:00ELECTRICAL PERMIT # VOIDED.
 NO ELECTRICAL WORK REQUIRING PERMIT AT
 THIS TIME.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-10-03 Cont ID  
Sent By dpalmer Date 2002-10-03 Time 14:38 Rev Time 0.25
Received By dpalmer Date 2002-10-03 Time 14:38 Sent To  
Notes
2002-10-03 00:00:00************** UNSAT ****************
  
 1)NOTE: PLEASE NOTE AN ELECTRICAL
 PERMIT IS BEING APPLIED FOR AND
 NO ELECTRICAL PLANS/DRAWINGS WERE
 SUBMITTED FOR REVIEW.;
 PLEASE SUBMIT
  
 2 )NOTE: PLEASE NOTE THAT ALL PLANS
 THAT ARE SIGNED AND SEALED BY ARCH/ OR
 ENGINEER ARE REQ`D PER 61G15-23.002 FOR
 ENGINEER AND 61G1-16.004 FOR ARCH.
 SHALL HAVE A TITLE BLOCK.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-11-14 Cont ID  
Sent By rbrown Date 2002-11-13 Time 15:59 Rev Time 0.00
Received By mcarsill Date 2002-11-14 Time 17:37 Sent To  
Notes
2002-11-14 00:00:001) SINCE LIMITED INFORMATION WAS
 PROVIDED WITH THE PLANS, THE RELOCATED
 DOORS MUST BE PRESUMED THAT THEY ARE
 EXIT DOORS AND SHALL MANDATE THAT
 IF THE DOORS ARE USED FOR EXITING
 PURPOSES, THEY MUST MEET ALL THE
 REQUIREMENTS OF NFPA 101, THE LIFE
 SAFETY CODE, 2000 EDITION, CHAPTER 7.
 THE INSTALLATION MUST BE SUBJECT TO
 FIELD INSPECTION AND SHOULD ANY
 DEFICIENCIES BE DISCOVERED THEY ARE
 TO BE CORRECTED WITH REGARDS TO EXITING.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-10-29 Cont ID  
Sent By btrobaug Date 2002-10-31 Time 10:35 Rev Time 0.00
Received By btrobaug Date 2002-10-29 Time 12:52 Sent To B
Notes
2002-10-29 00:00:00TO BUILDING MISC. BOX./WRT.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-11-13 Cont ID  
Sent By rbrown Date 2002-11-13 Time 15:44 Rev Time 0.00
Received By rbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2002-11-13 Cont ID  
Sent By rbrown Date 2002-11-13 Time 15:44 Rev Time 0.00
Received By rbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2002-10-24 Cont ID  
Sent By sgraham Date 2002-10-24 Time 15:07 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-10-17 Cont ID  
Sent By sgraham Date 2002-10-17 Time 13:42 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-10-17 00:00:00NEED SITE PLAN TO SHOW LOCATION