Plan Review Details - Permit 02100091
| Plan Review Stops For Permit 02100091 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-11-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-31 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2002-11-13 |
Time |
14:08 |
Sent To |
FIRE |
|
| Notes |
| 2002-11-13 00:00:00 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | --BEFORE PERMIT-- | | | A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | --BEFORE PERMIT-- | | | THE PROPOSED WORK WILL INCREASE FLOOR | | | AREA. IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | --PROVISO-- | | | FBC 3401.7.1.3DUE TO THE INCREASED FLR | | | AREA, THE RELOCATED STORE FRONT SHALL | | | CONFORM TO CURRENT CODE REQUIREMENTS. | | | FBC 1012.1THE PLANS DO NOT STATE THE | | | DOOR HARDWARE TYPE OR THE OCCUPANCY OF | | | THE SPACE.THEREFOR, THE DOORS ARE | | | ASSUMED TO BE EGRESS DOORS AND SHALL | | | ONLY BE PERMITTED TO HAVE LOCKS/LATCHES | | | WHICH ARE OPENABLE, USING ONE HAND, | | | WITHOUT THE USE OF A KEY, TOOL OR | | | SPECIAL KNOWLEDGE. | | | | | | --PROVISO-- | | | THE HEAD FASTENING ARRANGEMENT FOR THE | | | METAL FLANGE STUD SHALL BE EQUIVALENT TO | | | OR BETTER THAN THE EXISTING FASTENING | | | ARRANGEMENT AT THE CURRENT LOCATION. | | | ALTERNATIVELY, STATE THE WIND PRESSURES | | | ON THE PLANS FOR VERIFICATION OF THE | | | PROPOSED FASTENINGS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2002-10-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-10-16 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-10-15 00:00:00 | ELECTRICAL PERMIT # VOIDED. | | | NO ELECTRICAL WORK REQUIRING PERMIT AT | | | THIS TIME. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-10-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-10-03 |
Time |
14:38 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2002-10-03 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2002-10-03 00:00:00 | ************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE AN ELECTRICAL | | | PERMIT IS BEING APPLIED FOR AND | | | NO ELECTRICAL PLANS/DRAWINGS WERE | | | SUBMITTED FOR REVIEW.; | | | PLEASE SUBMIT | | | | | | 2 )NOTE: PLEASE NOTE THAT ALL PLANS | | | THAT ARE SIGNED AND SEALED BY ARCH/ OR | | | ENGINEER ARE REQ`D PER 61G15-23.002 FOR | | | ENGINEER AND 61G1-16.004 FOR ARCH. | | | SHALL HAVE A TITLE BLOCK. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2002-11-14 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2002-11-13 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-11-14 |
Time |
17:37 |
Sent To |
|
|
| Notes |
| 2002-11-14 00:00:00 | 1) SINCE LIMITED INFORMATION WAS | | | PROVIDED WITH THE PLANS, THE RELOCATED | | | DOORS MUST BE PRESUMED THAT THEY ARE | | | EXIT DOORS AND SHALL MANDATE THAT | | | IF THE DOORS ARE USED FOR EXITING | | | PURPOSES, THEY MUST MEET ALL THE | | | REQUIREMENTS OF NFPA 101, THE LIFE | | | SAFETY CODE, 2000 EDITION, CHAPTER 7. | | | THE INSTALLATION MUST BE SUBJECT TO | | | FIELD INSPECTION AND SHOULD ANY | | | DEFICIENCIES BE DISCOVERED THEY ARE | | | TO BE CORRECTED WITH REGARDS TO EXITING. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-10-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-31 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-10-29 |
Time |
12:52 |
Sent To |
B |
|
| Notes |
| 2002-10-29 00:00:00 | TO BUILDING MISC. BOX./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2002-11-13 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2002-11-13 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-13 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2002-11-13 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2002-10-24 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-10-24 |
Time |
15:07 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2002-10-17 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-10-17 |
Time |
13:42 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-10-17 00:00:00 | NEED SITE PLAN TO SHOW LOCATION |
|
|
|