Plan Review Details - Permit 02100090
Plan Review Stops For Permit 02100090
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-11-13 Cont ID  
Sent By dpalmer Date 2003-02-27 Time 10:26 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-11-13 00:00:00BUILDING PROVISO
  
 1)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR DOUBLE OUTSWING FRONT
 DOOR.
  
 2) THE CITY BUILDING INSPECTORS MAY
 REQUEST ADDITIONAL INFORMATION OR
 ENGINEERING AS THE WORK PROGRESSES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-11-01 Cont ID  
Sent By btrobaug Date 2002-11-12 Time 17:08 Rev Time 3.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-11-01 00:00:00BUILDING DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
 SPECIFY THE DESIGN CRITERIA ON THE PLANS
 FOR THE STRUCTURAL REPAIRS. REPAIRS
 SHALL COMPLY WITH THE 2001 FLORIDA
 BUILDING CODE. SEE FBC 3401.7.2.4 AND
 3401.7.2.5.
  
 3) REVISE WINDOW AND DOOR BUCK DETAILS
 TO COMPLY WITH FBC SEC.1707.4.4.2. BUCKS
 1-1/2" OR GREATER IN THICKNESS SHALL
 EXTEND BEYOND THE INTERIOR FACE OF
 WIDOW AND DOOR FRAMES.
  
 4) CLARIFY THE "C" TRUSS CONNECTOR
 SPECIFIED ON A2. IS THIS A "USP", USC
 UPLIFT STRAP CONNECTOR? DID YOU INTEND
 TO SPECIFY (8) 16D NAILS, RATHER THAN
 81- 16D NAILS.
  
 5) THE SITE SPECIFIC PRODUCT APPROVALS
 SUBMITTED ARE NOT ACCEPTABLE. THEY DO
 NOT REFERENCE THE 2001 FBC, THEY ARE NOT
 SIGNED, SEALED AND DATED BY THE ENGINEER
 FOR THE PRODUCT AND THEY MUST BE SIGNED,
 SEALED AND DATED BY THE DESIGNER OF
 RECORD OF THE STRUCTURE. TWO (2) FORMS
 ARE REQUIRED FOR EACH PRODUCT.
  
 6) ONLY ONE COPY OF THE PRODUCT APPROVAL
 FOR THE SINGLE HUNG DUAL ACTION WINDOW
 WAS SUBMITTED, TWO (2) COPIES ARE
 REQUIRED.
  
 7) THE PRODUCT APPROVALS SUBMITTED FOR
 THE SLIDING GLASS DOORS DO NOT APPLY TO
 TWO PANEL DOORS. MOST OF THE INFORMATION
 ON THE DRAWINGS IS ILLEGIBLE. PLEASE
 SUBMIT (2) CLEAR COPIES OF THE
 APPROPRIATE PRODUCT APPROVALS.
  
 8)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR STRUCTURAL WINDOW MULLIONS
  
 9) IMPACT PROTECTION IS REQUIRED FOR ALL
 GLAZED EXTERIOR OPENINGS THAT ARE BEING
 REPLACED PER FBC 1606.1.4.
 PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS.
  
 10) THE CITY BUILDING INSPECTOR MAY
 REQUEST ADDITIONAL INFORMATION OR
 ENGINEERING AS THE WORK PROGRESSES.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-03-06 Cont ID  
Sent By btrobaug Date 2003-03-06 Time 11:04 Rev Time 0.50
Received By btrobaug Date 2003-03-06 Time 10:46 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-02-14 Cont ID  
Sent By btrobaug Date 2003-02-14 Time 16:08 Rev Time 0.50
Received By btrobaug Date 2003-02-14 Time 15:49 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-10-04 Cont ID  
Sent By btrobaug Date 2003-02-12 Time 15:24 Rev Time 1.00
Received By btrobaug Date 2002-10-04 Time 06:41 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-02-27 Cont ID  
Sent By dpalmer Date 2003-02-27 Time 10:26 Rev Time 0.00
Received By dpalmer Date 2003-02-27 Time 10:25 Sent To B
Notes
2003-02-27 00:00:00TO ROBERT MCD'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-02-12 Cont ID  
Sent By btrobaug Date 2003-02-12 Time 15:24 Rev Time 0.00
Received By btrobaug Date 2003-02-11 Time 15:24 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2002-12-11 Cont ID  
Sent By btrobaug Date 2002-12-11 Time 18:39 Rev Time 0.00
Received By btrobaug Date 2002-12-11 Time 18:39 Sent To B
Notes
2002-12-11 00:00:00TO ROB M./WRT.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-11-12 Cont ID  
Sent By btrobaug Date 2002-11-12 Time 17:08 Rev Time 0.00
Received By btrobaug Date 2002-11-12 Time 17:08 Sent To B
Notes
2002-11-12 00:00:00TO ROB M./WRT

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-10-09 Cont ID  
Sent By btrobaug Date 2002-10-04 Time 09:59 Rev Time 0.40
Received By pkrauss Date 2002-10-09 Time 15:02 Sent To P
Notes
2002-10-09 00:00:00PROVISO:MECHANICAL PERMIT 02100416
  
 PLEASE NOTE - FIRE DAMPERS ARE NOT
 REQUIRED IN SINGLE FAMILY DWELLING.
  
 SMOKE DETECTORS SHALL BE INSTALLED
 SUPPLY SYSTEMS WITH A DESIGN CAPACITY
 GREATER THAN 2,000 CFM, IN THE SUPPLY
 AIR DUCT. 2001 FBC(M) 606.2.1OR
 UPON ACTIVATION, THE SMOKE DETECTORS
 SHALL SHUTDOWN THE AIR DISTRIBUTION
 SYSTEM. 2001 FBC(M) 606.4
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-10-10 Cont ID  
Sent By btrobaug Date 2003-03-06 Time 11:04 Rev Time 0.00
Received By kstevens Date 2002-10-10 Time 17:40 Sent To  
Notes
2002-10-10 00:00:00SEPARATE PERMIT REQUIRED FOR GAS

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2003-02-28 Cont ID  
Sent By rmcdouga Date 2003-02-28 Time 11:57 Rev Time 1.00
Received By rmcdouga Date 2003-02-28 Time 11:57 Sent To P
Notes
2003-02-28 00:00:00REVISION OK 2-28-03

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2003-02-18 Cont ID  
Sent By rmcdouga Date 2003-02-18 Time 14:40 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-02-18 00:00:00REVISION DENIED
  
 1) PLEASE CLOUD AND NUMBER REVISIONS.
  
 2) THE NEW WINDOW IN THE BATHROOM IS
 REQUIRED TO BE TEMPERED GLASS PER FBC
 2405.2.1.
  
 3) THE HORIZONTAL SLIDING WINDOW AT THE
 KITCHEN SINK IS INDICATED AS A S.G.DOOR
 ON A1. PLEASE CORRECT.
  
 4) THE PRODUCT APPROVAL SUBMITTED FOR
 THE FRONT DOOR IS FOR A SINGLE OUTSWING
 DOOR. THE PLANS INDICATE THE FRONT DOOR
 TO BE DOUBLE OUTSWING DOORS. PLEASE
 SUBMIT THE APPROPRIATE APPROVALS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2002-12-13 Cont ID  
Sent By rmcdouga Date 2002-12-13 Time 10:05 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-12-13 00:00:00TRUSSES DENIED
  
 1) THE TRUSS DRAWINGS ARE DESIGNED FOR
 A 110 MPH WINDLOAD THE CITY OF WPB IS
 LOCATED IN A 140 MPH WIND ZONE. SEE FBC
 1606 AND ASCE 7-98.
  
 2) THE DESIGNER OF RECORD FOR THE
 STRUCTURE IS REQUIRED TO REVIEW AND
 APPROVE THE TRUSS DRAWINGS AND LAYOUT.
  
 3) THE TRUSS ENGINEER'S WET SIGNATURE IS
 REQUIRED ON ALL DOCUMENTS SUBMITTED FOR
 PUBLIC RECORD. SEE 61G15-23.002 FAC.
 A SIGNATURE STAMP IS NOT ACCEPTABLE.
  
 4) THE TRUSS PACKAGES FOR ONE AND TWO
 FAMILY DWELLINGS ARE NOT REQUIRED TO BE
 SUBMITTED FOR PLAN REVIEW. THEY ARE
 REQUIRED TO BE GIVEN TO THE BUILDING
 INSPECTOR TO REVIEW AT TIME OF TRUSS
 INSPECTION AND HE WILL BRING IN THE
 SIGNED AND SEALED DRAWINGS TO BE FILED
 WITH THE APPROVED PLANS FOR PUBLIC
 RECORD.

Review Stop Z ZONING
Rev No 1 Status N Date 2002-11-01 Cont ID  
Sent By rmcdouga Date 2002-11-01 Time 14:13 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***