Plan Review Details - Permit 02100056
| Plan Review Stops For Permit 02100056 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-11-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-18 |
Time |
11:19 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
R |
|
| Notes |
| 2002-11-18 00:00:00 | TO HAROLD P./WRT |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-11-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-15 |
Time |
16:37 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2002-10-23 |
Time |
06:26 |
Sent To |
R |
|
| Notes |
| 2002-10-23 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE PROVIDE THE FOLLOWING | | | INFORMATION,MAKE ANY NECESSARY CHANGES | | | ON THE PLANS AND RESUBMIT FOR REVIEW. | | | | | | 1} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 2} PLEASE LIST THE LAUNDRY CIRCUIT @ | | | 1500 VA PER 220-16.REVISE CALCS. | | | | | | 3} PLEASE INCLUDE ALL A/C UNITS IN LOAD | | | CALCS. | | | | | | 4} PLEASE LIST THE REQ'D BATH(S) | | | CIRCUIT(S). PER 210-11-C-3 | | | MUST BE 20A AND #12AWG. | | | | | | 5} PLEASE CHECK ELECTRICAL NOTE #18 | | | REGARDING 210-12,FOR ACCURACY. | | | | | | 6} PLEASE NOTE THAT A SMOKE DETECTOR IS | | | REQUIRED OUTSIDE THE MASTER SUITE PER | | | 8-1.4.1.6.2 NFPA-72. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL; | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/659-8096 EXT. 8392 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-11-15 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-11-15 |
Time |
16:37 |
Sent To |
E |
|
| Notes |
| 2002-11-15 00:00:00 | TO WRT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2002-10-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-10-21 |
Time |
17:54 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2002-10-21 |
Time |
17:54 |
Sent To |
|
|
| Notes |
| 2002-10-21 00:00:00 | NO A/C PLAN. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-06-19 |
Time |
16:55 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2003-06-19 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2003-06-19 00:00:00 | REVISED RISER DIAGRAM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-10-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-10-21 |
Time |
17:55 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2002-10-21 |
Time |
17:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2002-11-19 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-11-19 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-11-18 |
Time |
16:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2002-11-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-18 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-11-06 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2002-11-07 00:00:00 | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED IMPACT FEES MUST BE PAID TO THE | | | COUN TY, THE PERMIT PLANS STAMPED BY | | | THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION.CALL 561-233-5025 FOR | | | MORE INFORMATION. | | | | | | THE ENERGY CODE FORMS ARE REQUIRED TO BE | | | SIGNED BY THE OWNER OR HIS AGENT. SEE | | | FBC 13-600.3ABC2 | | | | | | MIAMI-DADE NOA #01-1031.06 HAS ILLEGIBLE | | | DRAWINGS AND THE COMPONENTS ARE NOT | | | SELECTED. | | | | | | THE NORANDEX PRODUCT CERTIFICATION HAS | | | ILLEGIBLE PAGES AND THE COMPONENTS, | | | (INCLUDING ANCHOR METHODS), ARE NOT | | | SELECTED | | | | | | NOA #00-1106.03 DOES NOT HAVE THE | | | COMPONENTS AND INSTALLATION METHOD | | | SELECTED. | | | | | | THE WAYNE DALTON DOORS ARE NOT A | | | RECOGNIZED TESTING AGENCY. | | | | | | THE SBCCI REPORT #2036 FOR THE SHUTTERS | | | DOES NOT HAVE THE COMPONENTS AND | | | FASTENERS SELECTED.NOTE, READ THE | | | LIMITATIONS AND COMPARE THE MATERIALS | | | TO THOSE SPECIFIED ON THE PLANS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-10-07 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-10-07 |
Time |
09:09 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|